1.Application of Auto-prescription combined with low-dose contrast and iterative reconstruction algorithm in the CT angiography of thoracodorsal artery
Jian HE ; Yijun LIU ; Wei WEI ; Mengting HU ; Jingyi ZHANG ; Qiye CHENG ; Deshuo DONG ; Zhiming MA ; Changyu DU
Journal of Practical Radiology 2025;41(5):861-865
Objective To explore the application value of Auto-prescription combined with low-dose contrast and adaptive statisti-cal iterative reconstruction-Veo(ASIR-V)algorithm in the computed tomography angiography(CTA)of thoracodorsal artery(TDA).Methods A total of 100 patients who underwent TDA CTA examination were prospectively selected.A tube voltage of 120 kVp and contrast agent of 1.5 mL/kg were used for group A(50 cases),and images were reconstructed with 40% post-set ASIR-V.The Auto-prescription for tube voltage and contrast agent of 1.2 mL/kg were used for group B(50 cases),while images were reconstruc-ted with 40%,60%,and 80% post-set ASIR-V,labeled as subgroups B1 to B3.The objective and subjective evaluation results of the images were compared between and within groups.Results Group A had an effective dose(ED)of 2.98(2.65,4.03)mSv,while group B had an ED of 1.92(1.44,3.33)mSv.The iodine intake in group B was lower than that in group A,and the CT value of the axillary artery in group B was significantly higher than that in group A(P<0.001).With the increased of ASIR-V level in group B,the signal-to-noise ratio(SNR)and contrast-to-noise ratio(CNR)of the images gradually increased(P<0.05).In terms of subjec-tive scores on axial images,both subgroups B2 and B3 were superior to group A(P<0.001);with the increased of ASIR-V level in group B,subjective scores of axial images increased first and then decreased,among which subjective score of subgroup B2 was the highest and the differences were statistically significant(P<0.001).In terms of subjective scores on three-dimensional image quality,subgroups B1 to B3 were superior to group A(P<0.001).Conclusion The use of Auto-prescription combined with low-dose con-trast and 60% ASIR-V can significantly optimize the display of TDA,and reduce the radiation dose and contrast agent dose to a certain extent.
2.Application value of auto-prescription technique combined with iterative reconstruction algorithm in low-dose CT pulmonary angiography
Changyu DU ; Yijun LIU ; Wei WEI ; Mengting HU ; Jingyi ZHANG ; Qiye CHENG ; Jian HE ; Anliang CHEN
Chinese Journal of Radiological Medicine and Protection 2025;45(7):685-691
Objective:To explore the application value of the double-low technique of auto-prescription technique combined with iterative reconstruction algorithm in CT pulmonary angiography (CTPA).Methods:A total of 86 patients who were clinically suspected of having pulmonary embolism and underwent CTPA examination in the First Affiliated Hospital of Dalian Medical University were prospectively collected and randomly assigned to a control group ( n = 45) and an observation group ( n = 41) according to the random number table method. In the control group, a tube voltage of 120 kVp was used with a standard iodine contrast agent dose of 60 ml, and images were reconstructed using the 40% adaptive statistical iterative reconstruction algorithm (ASIR-V). In the observation group, the tube voltage was set by auto-prescription technique, and 0.4 ml/kg of personalized low iodine contrast agent was used. Images were reconstructed with 40%, 60%, and 80% ASIR-V, respectively, and designated as observation 1, observation 2, and observation 3 respectively. The volume CT dose index (CTDI vol), dose-length product (DLP), and effective dose ( E) were recorded and compared among the four groups. The CT values and standard deviation (SD) of the main pulmonary artery, left and right pulmonary arteries, as well as the left and right pulmonary lobe arteries were measured, and the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of these arteries were calculated. Additionally, the SD value at the contrast medium concentration in the superior vena cava was measured, and the artifact index (AI) was subsequently calculated. Two observers independently assessed the visibility of the pulmonary arteries, image noise, and sclerosis artifacts in the superior vena cava using a blinded method. Results:The E in the observation group was 3.28 (2.08, 3.93) mSv, which was significantly lower than that in the control group [5.03 (4.86, 5.20)] mSv, and the difference was statistically significant ( Z = 174.00, P < 0.05). The contrast agent dosage in the observation group was 28 (25, 30) ml, which was lower than that in the control group (60 ml), and the difference was statistically significant ( Z = 0, P < 0.05). The CT values for the main pulmonary artery and the left and right pulmonary lobe arteries in the observation group were higher than those in the control group, and the differences were all statistically significant ( t = -3.65 to -3.89, P < 0.05). The SNR and CNR of the observation groups 2 and 3 were greater than those of the control group ( t = -9.20 to -2.98, P < 0.05). The consistency of subjective evaluations between the two observers was good ( Kappa = 0.729 - 0.879, P < 0.05). There was no statistically significant difference in the subjective score of pulmonary artery visibility between the control and observation group ( P > 0.05). The subjective scores for image noise in observation group 2 and group 3 were higher than those in the control group ( U =598.50, 654.00, P < 0.05). The presence of artifacts due to sclerosis in the superior vena cava was significantly lower in the observation group compared to the control group ( χ2 = 46.09, P < 0.001). Conclusions:The combination of auto-prescription technique with ASIR-V reconstruction algorithm and low contrast agent imaging protocol can reduce the radiation dose and contrast agent dose without compromising image quality, and enable personalized double low CTPA imaging.
3.Deep learning image reconstruction algorithm combined with a large reconstruction matrix for low-dose CT screening of lung nodules
Changyu DU ; Wei WEI ; Mengting HU ; Jingyi ZHANG ; Qiye CHENG ; Jian HE ; Anliang CHEN ; Yijun LIU
Journal of Practical Radiology 2025;41(11):1886-1890
Objective To explore the application value of deep learning image reconstruction(DLIR)algorithm combined with a large reconstruction matrix in lung nodules screening using low-dose computed tomography(LDCT)of the chest.Methods Patients who underwent LDCT scans were prospectively enrolled.The control group(group A)used the iterative reconstruction(IR)algorithm(Karl)with a reconstruction level of Karl 5,reconstructed images of 512×512(group A1)matrix,and 1 024 × 1 024(group A2)matrix.The experimental group employed DLIR combined with 512×512(group B)matrix and 1 024 × 1 024(group C)matrix for image reconstruction at levels 1-5,which were recorded as groups B1-5 and groups C1-5.The CT values and standard deviation(SD)values of the lung parenchyma and tracheal air were measured,and the signal-to-noise ratio(SNR)was calculated.The overall lung image quality was scored on a Likert 5-point scale,and the subgroup with the best lung image quality was selected.The lung nodule detec-tion rate and clarity were compared with group A1.Results Under the same reconstruction matrix,the CT values of the tracheal air and lung parenchyma in the experimental group showed no significant difference compared to the control group,while the SD values were lower and SNR were higher(P<0.05).Within groups B and C,as the DLIR level increased,the SD values of the tracheal air and lung paren-chyma gradually decreased,and SNR gradually improved(P<0.05).Subjective scores for the image quality in groups B and C initially increased and then decreased,with group B3 and group C4 showed the best image quality.No difference was observed in objective eval-uation between the two groups,but the subjective image quality score of group C4 was superior to group B3(P<0.05).Subjective eval-uation of lung nodule display in group C4 was better than in group A1(P<0.05).Conclusion DLIR algorithm combined with a large reconstruction matrix is feasible for lung nodules screening in chest LDCT,reducing image noise while improving lung nodules clarity,demonstrating significant clinical value.
4.Optimization of a genetically encoded fluorescent sensor for the detection of 5-HT
Mufan XU ; Kun ZHANG ; Jingyi WANG ; Xinke GAO ; Aobing CHENG ; Peng ZHANG
Journal of Shanghai Jiaotong University(Medical Science) 2025;45(5):529-539
Objective·To optimize iSeroSnFR,a genetically encoded 5-hydroxytryptamine(5-HT)fluorescent sensor based on bacterial periplasmic binding proteins(PBPs),to enhance its performance for both in vivo and in vitro 5-HT detection.Methods·iSeroSnFR1.2 was engineered by replacing the circularly permuted superfolder green fluorescence protein(cpsfGFP)sequence in iSeroSnFR1.0 with that from the acetylcholine sensor iAChSnFR using Gibson assembly.The fluorescence response and kinetic properties of iSeroSnFR1.0 and iSeroSnFR1.2 were compared by overexpressing the sensors in HEK293 cells and puffing with exogenous 5-HT.Additionally,to mimic physiological conditions,cultured mouse cortical neurons infected with Sindbis virus carrying each sensor were electrically stimulated to induce endogenous 5-HT release and further evaluate sensor performance.Results·iSeroSnFR1.2 showed significantly improved performance over iSeroSnFR1.0.In HEK293 cells,it exhibited a 1.5-fold increase in fluorescence response(ΔF/F0)to exogenous 5-HT,along with faster kinetics(rise time:36.3 ms vs 44.9 ms;decay time:1 003.6 ms vs 1 730.4 ms).In cortical neurons,it demonstrated a 2.7-fold increase in response to endogenously released 5-HT,with rise and decay times reduced by 44.0%and 26.7%,respectively.Notably,iSeroSnFR1.2 showed increased basal fluorescence,enabling better imaging in high-background environments.Conclusion·The optimized iSeroSnFR1.2 sensor offers a markedly improved fluorescent response and temporal resolution for 5-HT detection,providing an advanced tool for studying 5-HT dynamics in neuroscience and psychiatric research.
5.Percutaneous coronary intervention vs . medical therapy in patients on dialysis with coronary artery disease in China.
Enmin XIE ; Yaxin WU ; Zixiang YE ; Yong HE ; Hesong ZENG ; Jianfang LUO ; Mulei CHEN ; Wenyue PANG ; Yanmin XU ; Chuanyu GAO ; Xiaogang GUO ; Lin CAI ; Qingwei JI ; Yining YANG ; Di WU ; Yiqiang YUAN ; Jing WAN ; Yuliang MA ; Jun ZHANG ; Zhimin DU ; Qing YANG ; Jinsong CHENG ; Chunhua DING ; Xiang MA ; Chunlin YIN ; Zeyuan FAN ; Qiang TANG ; Yue LI ; Lihua SUN ; Chengzhi LU ; Jufang CHI ; Zhuhua YAO ; Yanxiang GAO ; Changan YU ; Jingyi REN ; Jingang ZHENG
Chinese Medical Journal 2025;138(3):301-310
BACKGROUND:
The available evidence regarding the benefits of percutaneous coronary intervention (PCI) on patients receiving dialysis with coronary artery disease (CAD) is limited and inconsistent. This study aimed to evaluate the association between PCI and clinical outcomes as compared with medical therapy alone in patients undergoing dialysis with CAD in China.
METHODS:
This multicenter, retrospective study was conducted in 30 tertiary medical centers across 12 provinces in China from January 2015 to June 2021 to include patients on dialysis with CAD. The primary outcome was major adverse cardiovascular events (MACE), defined as a composite of cardiovascular death, non-fatal myocardial infarction, and non-fatal stroke. Secondary outcomes included all-cause death, the individual components of MACE, and Bleeding Academic Research Consortium criteria types 2, 3, or 5 bleeding. Multivariable Cox proportional hazard models were used to assess the association between PCI and outcomes. Inverse probability of treatment weighting (IPTW) and propensity score matching (PSM) were performed to account for potential between-group differences.
RESULTS:
Of the 1146 patients on dialysis with significant CAD, 821 (71.6%) underwent PCI. After a median follow-up of 23.0 months, PCI was associated with a 43.0% significantly lower risk for MACE (33.9% [ n = 278] vs . 43.7% [ n = 142]; adjusted hazards ratio 0.57, 95% confidence interval 0.45-0.71), along with a slightly increased risk for bleeding outcomes that did not reach statistical significance (11.1% vs . 8.3%; adjusted hazards ratio 1.31, 95% confidence interval, 0.82-2.11). Furthermore, PCI was associated with a significant reduction in all-cause and cardiovascular mortalities. Subgroup analysis did not modify the association of PCI with patient outcomes. These primary findings were consistent across IPTW, PSM, and competing risk analyses.
CONCLUSION
This study indicated that PCI in patients on dialysis with CAD was significantly associated with lower MACE and mortality when comparing with those with medical therapy alone, albeit with a slightly increased risk for bleeding events that did not reach statistical significance.
Humans
;
Percutaneous Coronary Intervention/methods*
;
Male
;
Female
;
Coronary Artery Disease/drug therapy*
;
Retrospective Studies
;
Renal Dialysis/methods*
;
Middle Aged
;
Aged
;
China
;
Proportional Hazards Models
;
Treatment Outcome
6.Analysis of the Construction Cases and Optimization Pathways for Compact Urban Medical Groups
Xuewei CHENG ; Yong LIU ; Kunshu WANG ; Jingyi LIU ; Yu WANG ; Liming BIAN
Chinese Hospital Management 2025;45(12):94-97
Promoting the construction of compact urban medical group has become an important part of building a high-quality,efficient,equitable,and accessible integrated integrated medical service system.Based on the policy orientation of the state to promote the construction of compact urban medical groups,it selects typical practical cases from Minhang(Shanghai),Luohu(Shenzhen),Hefei,and Qiqihar.lt analyzes their current explorations in organizational models and operational mechanisms,summarizes the main challenges they face,and accordingly proposes targeted optimization pathways,aiming to provide a reference for optimizing integrated medical service systems and forming establishing a orderly medical seeking system.
7.Pristimerin induces Noxa-dependent apoptosis by activating the FoxO3a pathway in esophageal squamous cell carcinoma.
Mengyuan FENG ; Anjie ZHANG ; Jingyi WU ; Xinran CHENG ; Qingyu YANG ; Yunlai GONG ; Xiaohui HU ; Wentao JI ; Xianjun YU ; Qun ZHAO
Chinese Journal of Natural Medicines (English Ed.) 2025;23(5):585-592
Pristimerin, which is one of the compounds present in Celastraceae and Hippocrateaceae, has antitumor effects. However, its mechanism of action in esophageal squamous cell carcinoma (ESCC) remains unclear. This study aims to investigate the efficacy and mechanism of pristimerin on ESCC in vitro and in vivo. The inhibitory effect of pristimerin on cell growth was assessed using trypan blue exclusion and colony formation assays. Cell apoptosis was evaluated by flow cytometry. Gene and protein expressions were analyzed through quantitative reverse transcription-polymerase chain reaction (qRT-PCR), Western blotting, and immunohistochemistry. RNA sequencing (RNA-Seq) was employed to identify significantly differentially expressed genes (DEGs). Cell transfection and RNA interference assays were utilized to examine the role of key proteins in pristimerin?s effect. Xenograft models were established to evaluate the antitumor efficiency of pristimerin in vivo. Pristimerin inhibited cell growth and induced apoptosis in ESCC cells. Upregulation of Noxa was crucial for pristimerin-induced apoptosis. Pristimerin activated the Forkhead box O3a (FoxO3a) signaling pathway and triggered FoxO3a recruitment to the Noxa promoter, leading to Noxa transcription. Blocking FoxO3a reversed pristimerin-induced Noxa upregulation and cell apoptosis. Pristimerin treatment suppressed xenograft tumors in nude mice, but these effects were largely negated in Noxa-KO tumors. Furthermore, the chemosensitization effects of pristimerin in vitro and in vivo were mediated by Noxa. This study demonstrates that pristimerin exerts an antitumor effect on ESCC by inducing AKT/FoxO3a-mediated Noxa upregulation. These findings suggest that pristimerin may serve as a potent anticancer agent for ESCC treatment.
Forkhead Box Protein O3/genetics*
;
Humans
;
Apoptosis/drug effects*
;
Esophageal Squamous Cell Carcinoma/physiopathology*
;
Esophageal Neoplasms/physiopathology*
;
Pentacyclic Triterpenes
;
Animals
;
Cell Line, Tumor
;
Proto-Oncogene Proteins c-bcl-2/genetics*
;
Mice
;
Signal Transduction/drug effects*
;
Mice, Nude
;
Cell Proliferation/drug effects*
;
Triterpenes/pharmacology*
;
Xenograft Model Antitumor Assays
;
Mice, Inbred BALB C
;
Male
;
Gene Expression Regulation, Neoplastic/drug effects*
8.Safety of a novel domestic direct visualization system of peroral cholangiopancreatoscopy for biliary tract exploration
Jingyi LIU ; Zhipeng QI ; Jiawei ZHANG ; Dongli HE ; Zhanghan CHEN ; Yirong CHENG ; Jieling JIANG ; Yan TANG ; Jiachen JING ; Yunshi ZHONG ; Pinxiang LU
Chinese Journal of Digestive Endoscopy 2025;42(1):28-33
Objective:To assess the safety of a novel domestically developed direct visualization system of peroral cholangiopancreatoscopy for the exploration of biliary tract.Methods:Clinical data from 384 patients with biliary tract diseases who underwent endoscopic retrograde cholangiopancreatography (ERCP) at the Endoscopy Center of Shanghai Xuhui District Central Hospital from November 2017 to December 2022 were retrospectively analyzed. Patients were categorized into 2 groups based on the type of cholangioscope: the novel cholangiopancreatoscopy system group ( n=159) and the SpyGlass group ( n=225). In the novel cholangiopancreatoscopy system group, the new direct visualization system of China-made peroral cholangiopancreatoscopy was used for bile duct exploration, while the SpyGlass group utilized the SpyGlass system for bile duct inspection. Propensity score matching (PSM) was used as a nearest-neighbor method with a caliper of 0.01 to minimize confounding factors, resulting in a balanced sample of 122 patients in each group after matching. The primary outcome was the incidence of short-term complications, with secondary outcomes including technical success rates and post-treatment outcomes. Results:After PSM, there were no significant differences in baseline characteristics between the two groups ( P>0.05). Regarding short-term postoperative complications, pancreatitis occurred in 1.6% (2/122) of patients in the novel cholangiopancreatoscopy system group and 7.4% (9/122) in the SpyGlass group. The new system significantly reduced the incidence of post-procedure pancreatitis ( χ2=4.665, P=0.031). The cholecystitis was absent in the novel cholangiopancreatoscopy system group, while it occurred in 0.8% (1/122) cases in the SpyGlass group, with no significant difference between the two groups after the procedure ( P=1.000). Regarding technical success rate, the novel system group achieved a rate of 99.2% (121/122), while the SpyGlass group achieved 97.5% (119/122) ( P=0.622). A slightly higher success rate was observed in the novel system group.There were 81 cases of postoperative biliary drainage in the novel cholangiopancreatoscopy system group and 74 cases in the SpyGlass group. Conclusion:The novel direct visualization system of peroral cholangiopancreatoscopy is safer than SpyGlass in the exploration of biliary system diseases. Endoscopists are encouraged to choose the appropriate cholangioscopy system based on individual patient characteristics for the direct visualization, diagnosis, and treatment of biliary diseases.
9.Clinical utility of a robotic intelligent endoscope transportation system in the digestive endoscopy center
Jianrong BAI ; Jun CHENG ; Xin WANG ; Lina CAO ; Jingyi LI ; Dongdong SUN ; Juan WANG ; Xiaoli JIA ; Tao CONG ; Rui JI ; Xiuli ZUO
Chinese Journal of Digestive Endoscopy 2025;42(8):628-633
Objective:To evaluate the clinical utility of an intelligent endoscope transportation system in the digestive endoscopy center.Methods:A parallel-group controlled trial was conducted at Digestive Endoscopy Center of Qilu Hospital of Shandong University from June 1st to December 31st 2024, comparing robotic intelligent endoscope transport (experimental group) versus manual transport (control group). Performance metrics, including response time, transportation speed, labor efficiency, contamination prevention, closed-loop traceability, and nursing staff satisfaction, were statistically analyzed. Full-time equivalent (FTE) was introduced to quantify the operational efficiency of the experimental group.Results:The study included a total of 60 206 instances of intelligent endoscope transportation and 60 485 instances of manual transportation data. The robotic group demonstrated significantly shorter response times versus manual group for initial dispatch (51.08±14.97 seconds VS 54.44±13.61 seconds, t=35.8, P<0.001) and recovery response time (32.52±11.26 seconds VS 40.20±11.40 seconds, t=103.93, P<0.001). During the 148 days operational period, the success rate was 99.83% (60 104/60 206) and the failure rate was 0.17% (102/60 206) for robotic transports. Primary failure causes were wireless disconnection, pathfinding errors, and mechanical faults, averaging 1.05 malfunctions/month with no adverse events. The success and failure rate was 99.26% (60 043/60 485) and 0.74% (442/60 485) respectively for manual transports. Staff satisfaction was significantly higher for robotic transport in endoscopic transportation (4.65±0.55 scores VS 3.97±0.98 scores, t=96.5, P<0.001) and delivery process (4.71±0.59 scores VS 3.90±1.04 scores, t=210.3, P<0.001). and workload intensity was significantly lower (4.06±0.77 scores VS 4.48±0.63 scores, t=59.9, P=0.025). The system reduced labor requirements by 3.68 FTE, yielding annual savings of ¥657 000. Conclusion:The robotic intelligent endoscope transport system improves work efficiency, reduces nursing labor costs and physical workload, enhances job experience and satisfaction, and enables full-process smart traceability, providing a validated solution for endoscopy center logistics.
10.Application value of auto-prescription technique combined with iterative reconstruction algorithm in low-dose CT pulmonary angiography
Changyu DU ; Yijun LIU ; Wei WEI ; Mengting HU ; Jingyi ZHANG ; Qiye CHENG ; Jian HE ; Anliang CHEN
Chinese Journal of Radiological Medicine and Protection 2025;45(7):685-691
Objective:To explore the application value of the double-low technique of auto-prescription technique combined with iterative reconstruction algorithm in CT pulmonary angiography (CTPA).Methods:A total of 86 patients who were clinically suspected of having pulmonary embolism and underwent CTPA examination in the First Affiliated Hospital of Dalian Medical University were prospectively collected and randomly assigned to a control group ( n = 45) and an observation group ( n = 41) according to the random number table method. In the control group, a tube voltage of 120 kVp was used with a standard iodine contrast agent dose of 60 ml, and images were reconstructed using the 40% adaptive statistical iterative reconstruction algorithm (ASIR-V). In the observation group, the tube voltage was set by auto-prescription technique, and 0.4 ml/kg of personalized low iodine contrast agent was used. Images were reconstructed with 40%, 60%, and 80% ASIR-V, respectively, and designated as observation 1, observation 2, and observation 3 respectively. The volume CT dose index (CTDI vol), dose-length product (DLP), and effective dose ( E) were recorded and compared among the four groups. The CT values and standard deviation (SD) of the main pulmonary artery, left and right pulmonary arteries, as well as the left and right pulmonary lobe arteries were measured, and the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of these arteries were calculated. Additionally, the SD value at the contrast medium concentration in the superior vena cava was measured, and the artifact index (AI) was subsequently calculated. Two observers independently assessed the visibility of the pulmonary arteries, image noise, and sclerosis artifacts in the superior vena cava using a blinded method. Results:The E in the observation group was 3.28 (2.08, 3.93) mSv, which was significantly lower than that in the control group [5.03 (4.86, 5.20)] mSv, and the difference was statistically significant ( Z = 174.00, P < 0.05). The contrast agent dosage in the observation group was 28 (25, 30) ml, which was lower than that in the control group (60 ml), and the difference was statistically significant ( Z = 0, P < 0.05). The CT values for the main pulmonary artery and the left and right pulmonary lobe arteries in the observation group were higher than those in the control group, and the differences were all statistically significant ( t = -3.65 to -3.89, P < 0.05). The SNR and CNR of the observation groups 2 and 3 were greater than those of the control group ( t = -9.20 to -2.98, P < 0.05). The consistency of subjective evaluations between the two observers was good ( Kappa = 0.729 - 0.879, P < 0.05). There was no statistically significant difference in the subjective score of pulmonary artery visibility between the control and observation group ( P > 0.05). The subjective scores for image noise in observation group 2 and group 3 were higher than those in the control group ( U =598.50, 654.00, P < 0.05). The presence of artifacts due to sclerosis in the superior vena cava was significantly lower in the observation group compared to the control group ( χ2 = 46.09, P < 0.001). Conclusions:The combination of auto-prescription technique with ASIR-V reconstruction algorithm and low contrast agent imaging protocol can reduce the radiation dose and contrast agent dose without compromising image quality, and enable personalized double low CTPA imaging.