1.The magnetic compression technique in the treatment of severe mid-ureteral stricture
Fanchao WEI ; Zhaoxiang WANG ; Shichao HAN ; Zhiwen DONG ; Yuxin FU ; Ruochen QI ; Guohui WANG ; Xiaoyan ZHANG ; Tong XU ; Jingliang ZHANG ; Weijun QIN ; Lijun YANG ; Shuaijun MA
Journal of Modern Urology 2026;31(2):182-186
Objective To explore the feasibility of magnetic compression technique (MCR) in the treatment of severe single mid-ureteral stricture in a rabbit model. Methods After 10 female New Zealand rabbits were selected, the distal end of the right ureter was ligated with silk thread. Two weeks after the operation, when the right ureter was dilated, the mid-ureter was ligated again with silk thread to create a severe single mid-ureteral stricture animal model. Longitudinal incisions were made at the upper and lower ends of the ligation site, and cylindrical NdFeB magnets with central holes (sub-magnets and main magnets) were placed to anastomose and recanalize the mid-ureteral stricture. The magnets were adjusted to the appropriate position to automatically align and attract each other. The longitudinal incision sites of the ureter were sutured with 6-0 Prolene thread, and the abdominal cavity was closed layer by layer. The operation time was recorded. X-ray films were taken every two days to confirm the position of the magnets and record the time of magnet detachment. Three weeks after the operation, the anastomotic specimens were obtained, and the formation of the anastomosis was evaluated with gross observation and histological staining. Results Two weeks after ligation, all experimental rabbits showed obvious dilation of the right ureter. The mid-ureteral ligation and placement of the male and female magnets were successfully completed in all 10 experimental rabbits, with an operation time of (24.00±5.15)minutes. The male and female magnets attracted each other well. X-ray examination showed that the magnets detached and entered the distal ureter (14.0±1.9) days after magnetic compression. The recanalization of the severe single mid-ureteral stricture was successfully achieved. The gross specimens and histological examination of the anastomosis showed that the anastomosis remained patent and the mucosal healing was good. All experimental rabbits survived well after the operation without serious complications. Conclusion MCT provides a new idea and novel method for the treatment of mid-ureteral stricture. This study confirmed the feasibility of this technique in treating severe single mid-ureteral stricture in a rabbit model. The operation is relatively simple and has potential for clinical application.
2.Report of 4 cases of IgG4-related urinary diseases and literature review
Fanchao WEI ; Zhaoxiang WANG ; Mengwei XU ; Ruochen QI ; Guohui WANG ; Xiaoyan ZHANG ; Tong XU ; Jingliang ZHANG ; Shuaijun MA ; Weijun QIN ; Lijun YANG ; Shichao HAN
Journal of Modern Urology 2025;30(1):59-63
[Objective] To explore the clinical features of IgG4-related urinary diseases so as to provide reference for the diagnosis and treatment of such diseases. [Methods] The clinical data of 4 cases of IgG4-related urinary system diseases diagnosed and treated in Xijing Hospital of Air Force Medical University during Aug.2019 and Dec.2023 were retrospectively collected.Here, we report on the diagnosis and treatment of these patients, analysing their symptoms, serology, imaging and pathology as well as their treatment and outcomes. [Results] The patients included 2 male and 2 female.The lesions were involved with the retroperitoneum and urinary system.Three patients had symptoms of lumbar pain.The imaging manifestations were complex, including retroperitoneal mass involving urinary system organs in 2 cases, tabdense shadow of the right kidney in 1 case, and simple cystic mass of kidney in 1 case.Serum IgG4 value was not detected before surgery.All patients underwent radical surgical treatment.Postoperative pathology showed fibrous tissue hyperplasia with a large number of plasma cells, lymphocytes, a few neutrophil infiltrates, and lymphoid follicles and obliterated vasculitis in some specimens.The number of IgG4+ plasma cells was more than 10 in all tissues under high power microscope.After surgery, 3 patients had symptoms improved, and serum IgG4 value was within the normal range; 1 patient (patem 3) had elevated IgG4 value during follow-up, received subsequent hormone therapy, and the serum IgG 4 level remained stable. [Conclusion] The symptoms of IgG4-related diseases involving the urinary system are non-specific, and the imaging findings are various, easily confused with other diseases.Early detection of serum IgG4 and biopsy pathology can help clinicians make correct diagnosis in the early stage.
3.Construction and application assessment of a dispatching system based on UWB positioning technique for emergency equipment
Xiaoling XI ; Jingliang WANG ; Yao XU ; Ling WENG
China Medical Equipment 2025;22(7):92-98
Objective:To construct a dispatching system based on ultra wide band(UWB)positioning technique,so as to enhance dynamic management capabilities for equipment and clinical response efficiency.Methods:The dispatching system based on UWB positioning technique for emergency equipment included internet of things(IoTs)perception layer of network,network layer,data service layer,and business application layer of intelligently medical equipment,which integrated the positioning technique with UWB centimeter level and the deep Q-network(DQN)algorithm,and it can realize real-time localization and intelligent dispatching decisions for equipment.The used thirty-five emergency equipment in the intensive care unit(ICU)ward of Eastern Branch of Ningbo Medical Center Li Huili Hospital from January 2023 to December 2024 were selected.Based on different management modes,25 equipment using conventional manual dispatching during January and June 2023 were divided into control group,while 25 equipment using the UWB dispatching technique-based dispatching system during July and December 2023(included 15 equipment of the original control group and 10 new equipment at later stage)were used as observation group.The dispatching efficiency,utilization rate,positioning precision,and maintenance efficiency of equipment between two groups were compared.Results:The dispatching time for equipment in the observation group was(7.2±0.8)min,which significantly shorter than(12.2±1.5)min in the control group,and the difference was significant(t=18.34,P<0.05).The distance of movement,and response time for fault in the observation group were significantly lower than those in the control group,and the utilization rate of equipment was significantly higher than that in the control group,and the differences were significant(t=15.67,14.28,6.92,P<0.05).The repair rate for fault in the observation group was significantly higher than that in the control group,and the difference was significant(x2=7.80,P<0.05).The positioning error of the system is(35±10)cm.Conclusion:The UWB-based dispatching system can significantly optimize the dispatching process for resource of emergency equipment,which can improve utilization and management efficiency for equipment.It can provide reliably technical support for rapid response in clinical emergency.
4.Plasma exchange and intravenous immunoglobulin prolonged the survival of a porcine kidney xenograft in a sensitized, brain-dead human recipient.
Shuaijun MA ; Ruochen QI ; Shichao HAN ; Zhengxuan LI ; Xiaoyan ZHANG ; Guohui WANG ; Kepu LIU ; Tong XU ; Yang ZHANG ; Donghui HAN ; Jingliang ZHANG ; Di WEI ; Xiaozheng FAN ; Dengke PAN ; Yanyan JIA ; Jing LI ; Zhe WANG ; Xuan ZHANG ; Zhaoxu YANG ; Kaishan TAO ; Xiaojian YANG ; Kefeng DOU ; Weijun QIN
Chinese Medical Journal 2025;138(18):2293-2307
BACKGROUND:
The primary limitation to kidney transplantation is organ shortage. Recent progress in gene editing and immunosuppressive regimens has made xenotransplantation with porcine organs a possibility. However, evidence in pig-to-human xenotransplantation remains scarce, and antibody-mediated rejection (AMR) is a major obstacle to clinical applications of xenotransplantation.
METHODS:
We conducted a kidney xenotransplantation in a brain-dead human recipient using a porcine kidney with five gene edits (5GE) on March 25, 2024 at Xijing Hospital, China. Clinical-grade immunosuppressive regimens were employed, and the observation period lasted 22 days. We collected and analyzed the xenograft function, ultrasound findings, sequential protocol biopsies, and immune surveillance of the recipient during the observation.
RESULTS:
The combination of 5GE in the porcine kidney and clinical-grade immunosuppressive regimens prevented hyperacute rejection. The xenograft kidney underwent delayed graft function in the first week, but urine output increased later and the single xenograft kidney maintained electrolyte and pH homeostasis from postoperative day (POD) 12 to 19. We observed AMR at 24 h post-transplantation, due to the presence of pre-existing anti-porcine antibodies and cytotoxicity before transplantation; this AMR persisted throughout the observation period. Plasma exchange and intravenous immunoglobulin treatment mitigated the AMR. We observed activation of latent porcine cytomegalovirus toward the end of the study, which might have contributed to coagulation disorder in the recipient.
CONCLUSIONS
5GE and clinical-grade immunosuppressive regimens were sufficient to prevent hyperacute rejection during pig-to-human kidney xenotransplantation. Pre-existing anti-porcine antibodies predisposed the xenograft to AMR. Plasma exchange and intravenous immunoglobulin were safe and effective in the treatment of AMR after kidney xenotransplantation.
Transplantation, Heterologous/methods*
;
Kidney Transplantation/methods*
;
Heterografts/pathology*
;
Immunoglobulins, Intravenous/administration & dosage*
;
Graft Survival/immunology*
;
Humans
;
Animals
;
Sus scrofa
;
Graft Rejection/prevention & control*
;
Kidney/pathology*
;
Gene Editing
;
Species Specificity
;
Immunosuppression Therapy/methods*
;
Plasma Exchange
;
Brain Death
;
Biopsy
;
Male
;
Aged
5.Construction and application assessment of a dispatching system based on UWB positioning technique for emergency equipment
Xiaoling XI ; Jingliang WANG ; Yao XU ; Ling WENG
China Medical Equipment 2025;22(7):92-98
Objective:To construct a dispatching system based on ultra wide band(UWB)positioning technique,so as to enhance dynamic management capabilities for equipment and clinical response efficiency.Methods:The dispatching system based on UWB positioning technique for emergency equipment included internet of things(IoTs)perception layer of network,network layer,data service layer,and business application layer of intelligently medical equipment,which integrated the positioning technique with UWB centimeter level and the deep Q-network(DQN)algorithm,and it can realize real-time localization and intelligent dispatching decisions for equipment.The used thirty-five emergency equipment in the intensive care unit(ICU)ward of Eastern Branch of Ningbo Medical Center Li Huili Hospital from January 2023 to December 2024 were selected.Based on different management modes,25 equipment using conventional manual dispatching during January and June 2023 were divided into control group,while 25 equipment using the UWB dispatching technique-based dispatching system during July and December 2023(included 15 equipment of the original control group and 10 new equipment at later stage)were used as observation group.The dispatching efficiency,utilization rate,positioning precision,and maintenance efficiency of equipment between two groups were compared.Results:The dispatching time for equipment in the observation group was(7.2±0.8)min,which significantly shorter than(12.2±1.5)min in the control group,and the difference was significant(t=18.34,P<0.05).The distance of movement,and response time for fault in the observation group were significantly lower than those in the control group,and the utilization rate of equipment was significantly higher than that in the control group,and the differences were significant(t=15.67,14.28,6.92,P<0.05).The repair rate for fault in the observation group was significantly higher than that in the control group,and the difference was significant(x2=7.80,P<0.05).The positioning error of the system is(35±10)cm.Conclusion:The UWB-based dispatching system can significantly optimize the dispatching process for resource of emergency equipment,which can improve utilization and management efficiency for equipment.It can provide reliably technical support for rapid response in clinical emergency.
6.Analysis of the interactive effects between smoking addiction and overweight on brain gray matter volume
Mengzhe ZHANG ; Xiaoyu NIU ; Jinghan DANG ; Jieping SUN ; Weijian WANG ; Jingliang CHENG ; Yong ZHANG
Chinese Journal of Psychiatry 2024;57(7):433-439
Objective:To investigate the correlation between brain gray matter volume (GMV) and interactive effects of smoking addiction and overweight.Methods:We retrospectively analyzed the clinical data and resting-state functional magnetic resonance imaging data of 99 subjects recruited from January 2019 to December 2021 through online platforms such as WeChat, including the following four groups: overweight smoking addiction group ( n=24), normal-weight smoking addiction group ( n=28), overweight non-smoking group ( n=19), and normal-weight non-smoking group ( n=28). All subjects underwent 3.0T MRI. We used voxel-based morphometry (VBM) to compare gray matter volume (GMV) among the four groups. A two-way analysis of variance was conducted with age, years of education, and head motion as covariates to explore the interaction effects between smoking addiction and weight status on GMV, the main effect of smoking addiction and main effect of overweight, which were then correlated with clinical data. Results:Significant interactive effects of smoking addiction and overweight were observed in the left dorsolateral prefrontal cortex (DLPFC) (GRF corrected, voxel-level P<0.001, cluster-level P<0.05). Correlation analysis showed a quadratic effect between body mass index and left DLPFC GMV (β=-3.846, t=-2.134, P=0.036). Additionally, the main effect of smoking addiction was primarily manifested in the bilateral orbitofrontal cortex (OFC)(GRF corrected, P voxel<0.001, P cluster<0.05). Left OFC GMV was negatively associated with the FTND (Fagerstrom Test of Nicotine Dependence) scores ( r=-0.391, P=0.006). And right OFC GMV was negatively correlated with the smoking index ( r=-0.335, P=0.019). No statistically significant main effect of overweight was found at the aforementioned threshold. Conclusion:Smoking addiction and overweight have antagonistic effects on left DLPFC GMV.
7.The dynamic patterns of intrinsic neural activity in individuals with internet gaming disorder: a resting state functional magnetic resonance imaging study
Xiaoyu NIU ; Xinyu GAO ; Mengzhe ZHANG ; Jinghan DANG ; Jieping SUN ; Weijian WANG ; Yong ZHANG ; Jingliang CHENG
Chinese Journal of Psychiatry 2024;57(2):87-93
Objective:This study aims to investigate the dynamic patterns of intrinsic neural activity and their relationships with Internet Addiction Test (IAT) scores in individuals with internet gaming disorder (IGD).Methods:Resting state functional magnetic resonance imaging (fMRI) scanning was performed on 33 individuals with IGD (IGD group) who were admitted to the psychiatric department of First Affiliated Hospital of Zhengzhou University and 40 healthy volunteers (control group) recruited through the online platform. The dynamic regional homogeneity (dReHo) values were calculated. The two-sample t test was used to analyze the differences of dReHo values between two groups (Gaussian random field corrected, voxel level P<0.001, cluster level P<0.05). Spearman correlation analyses were used to analyze the correlations between IAT scores and dReHo values of brain regions with statistically significant differences between IGD group and control group. Results:Compared with the control group, the IGD group showed increased dReHo values in the right thalamus, right caudate nucleus, left putamen, bilateral medial superior frontal gyrus, bilateral supplementary motor area, and bilateral superior frontal gyrus ( t=3.84-4.94, Gaussian random field corrected, voxel level P<0.001, cluster level P<0.05). The dReHo value in the right medial superior frontal gyrus was positively correlated with IAT scores ( r=0.395, P=0.023) in IGD group. Conclusion:Individuals with IGD exhibited a wide range of abnormal dynamic patterns of intrinsic neural activity in pivotal regions associated with reward processing and cognitive control functions (the fronto-striato-thalamic circuit), providing new insights into the underlying neural mechanisms of IGD.
8.Resting-state functional magnetic resonance imaging study on the interaction effects between smoking addiction and weight status on brain activity
Mengzhe ZHANG ; Xiaoyu NIU ; Jinghan DANG ; Jieping SUN ; Weijian WANG ; Jingliang CHENG ; Yong ZHANG
Chinese Journal of Behavioral Medicine and Brain Science 2024;33(3):240-245
Objective:To explore the interaction effects on brain activity between the smoking addiction and weight status by resting-state functional magnetic resonance imaging.Methods:Retrospective analysis of clinical data and resting-state functional magnetic resonance imaging data were analyzed from 99 recruited subjects from January 2019 to December 2021. All participants were divided into four groups: overweight smokers ( n=24), normal-weight smokers ( n=28), overweight non-smokers ( n=19), and normal weight non-smokers ( n=28). Calculate regional homogeneity (ReHo) to reflect the internal brain activity of the subjects. Two-way ANOVA was used to detect the interaction effects between smoking addiction and overweight on ReHo by SPM12 software, correcting for age, years of education and head motion. Results:The interaction effect between smoking addiction and overweight on ReHo was significant in right superior frontal gyrus(x, y, z=15, 9, 60)(GRF corrected, Pvoxel<0.005, Pcluster<0.05). The ReHo value in the right superior frontal gyrus of overweight smokers was significantly higher than that of normal weight smokers ( t=3.768, P<0.001, Bonferroni corrected). The ReHo values in the right superior frontal gyrus of overweight non-smokers were significantly lower than those of normal weight non-smokers ( t=-3.242, P=0.002, Bonferroni corrected). The ReHo values in the right superior frontal gyurs of normal-weight smokers were significantly lower than those of normal weight non-smokers( t=-3.540, P=0.001, Bonferroni corrected). The ReHo values in the right superior frontal gyrus of overweight smokers were significantly higher than those of overweight non-smokers ( t=3.392, P=0.002, Bonferroni corrected). Correlation analyses showed that the strengthen ReHo value in right superior frontal gyrus was positively associated with pack-year in smoking addicts( r=0.387, P=0.007, Bonferroni corrected). Conclusion:Smoking addiction and overweight have an antagonistic effect on brain activity in the right superior frontal gyrus, which may provide potential therapeutic targets for individuals with comorbidity of smoking addiction and overweight.
9.Value of synthetic MRI in the differential diagnosis of parotid gland tumors
Zanxia ZHANG ; Shujian LI ; Yong ZHANG ; Weijian WANG ; Manli SONG ; Wenhao WANG ; Baohong WEN ; Jingliang CHENG
Journal of Practical Radiology 2024;40(3):361-364
Objective To investigate the application value of quantitative relaxation parameters based on synthetic MRI technology in the differential diagnosis of parotid gland tumors.Methods Conventional MRI and synthetic MRI data of 59 patients with patho-logically confirmed parotid gland tumors were analyzed retrospectively.T1,T2,and proton density(PD)values of the tumor were extracted from T1,T2 and PD mapping.The differences in quantitative relaxation parameters of pleomorphic adenomas,Warthin tumors,and malignant tumors were further compared.Diagnostic performance of each quantitative relaxation parameter was assessed and com-pared via receiver operating characteristic(ROC)curve and DeLong test.Results T2 value was significantly higher in pleomorphic adenomas than that in malignant tumors(P<0.05).The T1,T2,and PD values of pleomorphic adenomas and malignant tumors were significantly higher than those of Warthin tumors(P<0.05).The area under the curve(AUC)of the T2 value in differentia-ting pleomorphic adenomas from malignant tumors was 0.794.The AUC for T1 value(0.939)in differentiating Warthin tumors from malignant tumors was significantly higher than that of T2(0.873,P=0.341)and PD(0.927,P=0.891)values,without sta-tistically significant difference.The AUC for T2 value(0.968)in differentiating pleomorphic adenomas from Warthin tumors was significantly higher than that of T1(0.931,P=0.360)and PD(0.876,P=0.120)values,without statistically significant difference.Conclusion Quantitative relaxation parameters based on synthetic MRI technology may contribute to differentiating pleomorphic adenomas,Warthin tumors,and malignant tumors of the parotid gland.
10.Comparison of the efficacy of amide proton transfer-weighted imaging and time-dependent diffusion MRI for the diagnosis of malignant breast lesions
Xiaoyan WANG ; Yan ZHANG ; Jingliang CHENG ; Liangjie LIN ; Zhigang WU ; Ying HU ; Yong ZHANG ; Anfei WANG ; Ying LI ; Ruhua WANG ; Kun ZHANG ; Wenhua ZHANG ; Baojing WANG
Chinese Journal of Radiology 2024;58(6):611-619
Objective:To compare the efficacy of amide proton transfer-weighted (APTw) imaging with time-dependent diffusion MRI (td-dMRI) in the diagnosis of malignant breast lesions.Methods:This study was a cross-sectional study. The clinical, pathological and imaging data of patients with breast lesions admitted to the First Affiliated Hospital of Zhengzhou University from March to August 2023 were prospectively analyzed. All patients firstly underwent T 2WI, diffusion-weighted imaging, followed by dynamic contrast-enhanced MRI (DCE-MRI), and finally APTw imaging and td-dMRI were performed for breast lesions using DCE-MRI as reference. Reconstructed images from APTw imaging measured lesions with a frequency shift of 3.5 ppm asymmetric magnetic susceptibility MTR asym(+3.5 ppm). The apparent diffusion coefficient (ADC) values at different oscillating frequency gradients (ADC PGSE, ADC 17 Hz, ADC 33 Hz values) were measured using reconstructed td-dMRI images. Independent sample t-test was used to compare APTw imaging, td-dMRI parameter differences between benign and malignant breast tumors, breast malignant tumors with different molecular types [estrogen receptor (ER) negative and positive, progesterone receptor (PR) negative and positive, human epidermal growth factor receptor (HER-2) negative and positive, proliferation index (Ki-67) low and high expression] and different histological grades (grade Ⅱ and Ⅲ). Receiver operating characteristic curve and area under the curve (AUC) were used to evaluate the efficacy of APTw imaging and td-dMRI parameters in differentiating benign and malignant breast tumors, molecular classification and histological grading of malignant breast lesions. Results:There were 171 lesions in 171 patients, including 103 malignant lesions and 68 benign lesions. Histological grades were grade Ⅱ in 51 cases and grade Ⅲ in 38 cases of 89 cases of invasive carcinoma. Totally 98 cases of malignant lesions were included in molecular typing analysis, 36 cases were ER negative and 62 cases were ER positive. PR was negative in 51 cases and positive in 47 cases. There were 33 negative HER-2 patients, 65 positive HER-2 patients. There were 50 cases of low Ki-67 expression and 48 cases of high Ki-67 expression. The MTR asym(+3.5 ppm) value of malignant breast lesions was higher than that of benign lesions ( t=5.76, P<0.001), and the ADC PGSE, ADC 17 Hz and ADC 33 Hz values were lower than those of benign breast lesions ( t was 4.84, 4.62, 4.01, respectively, all P<0.001). MTR asym(+3.5 ppm) had the highest AUC value (0.83) and the highest specificity (90.38%), and ADC PGSE had the highest sensitivity (85.86%). There were no significant differences in MTR asym(+3.5 ppm), ADC PGSE, ADC 17 Hz and ADC 33 Hz between grade Ⅱ and grade Ⅲ histological grades of malignant breast lesions (all P>0.05). The ADC PGSE value of ER negative was higher than that of ER positive ( t=2.34, P=0.018), and the AUC for distinguishing ER positive from negative was 0.64. The ADC PGSE and ADC 17 Hz values of PR negative were higher than those of PR positive ( t=2.87, 2.81, P=0.004, 0.006, respectively), and their AUCs for identifying PR positive versus negative breast malignant lesions were 0.68 and 0.67, respectively. The ADC 33 Hz value of negative HER-2 was lower than that of positive HER-2 ( t=3.00, P=0.003), and the AUC for distinguishing positive and negative HER-2 was 0.67. There were no significant differences in other parameters among different subtypes of breast malignant lesions (all P>0.05). Conclusion:Compared with td-dMRI, APTw imaging is more effective in differentiating benign and malignant lesions of breast tumors, and ADC values at different gradient oscillation frequencies obtained by td-dMRI show better diagnostic efficacy in differentiating different molecular types of breast malignant lesions.

Result Analysis
Print
Save
E-mail