1.C-arm CT stent precision technology in intracranial arterial stent implantation
Ji YIN ; Li ZHU ; Xiaolin HOU ; Lingling ZHANG ; Jingke YU
Chinese Journal of Medical Imaging Technology 2025;41(2):331-335
Objective To observe the value of C-arm CT stent precision technology in intracranial arterial stent implantation.Methods Data of 38 patients with symptomatic intracranial atherosclerotic stenosis who underwent intracranial arterial stent implantation were retrospectively analyzed.Stent displayed in 2D-digital subtraction angiography(DSA)during and immediately after implantation were observed,and superselective C-arm CT scanning of target artery and stent precision reconstruction were performed.Subjective scoring of display stent structure in 2D-DSA and stent precision reconstruction images were comparatively analyzed,and the clarity rate of displaying stent and detection rate of related complications were compared.Results Totally 45 stents were implanted in 38 patients.In 2D-DSA,the subjective score was 0 of 1,1 of 20 and 2 of 24 stents,respectively.Stent precision reconstruction image showed that subjective score was 0 of 1 stent and was 3 of 44 stents.The clarity rate of displaying stent in stent precision reconstruction image was 97.78%(44/45),much higher than that of 2D-DSA image(0[0/45],P<0.001).Among 44 stents displayed in 2D-DSA,poor stent opening and abnormal perforator vessel was observed in each 1 stent,and no clear abnormality was found in the rest stents.Among 44 stents revealed in stent precision reconstruction images,poor stent opening,thromboses in stent and stent mesh protruding into vascular lumen were found each in 2 stents,while perforator vessel spasm and localized stenosis after stent implantation were noticed in 3 stents.Arterial dissection occurred in 8 stents during balloon dilation,after timely implantation of a new stent,stent precision reconstruction images showed the dissection rupture was completely covered.The complications of stent precision reconstruction was higher than that of 2D-DSA(38.64%[17/44]vs.4.55%[2/44].P=0.002).Conclusion C-arm CT stent precision technique had obvious advantages for intracranial artery stent implantation.
2.C-arm CT stent precision technology in intracranial arterial stent implantation
Ji YIN ; Li ZHU ; Xiaolin HOU ; Lingling ZHANG ; Jingke YU
Chinese Journal of Medical Imaging Technology 2025;41(2):331-335
Objective To observe the value of C-arm CT stent precision technology in intracranial arterial stent implantation.Methods Data of 38 patients with symptomatic intracranial atherosclerotic stenosis who underwent intracranial arterial stent implantation were retrospectively analyzed.Stent displayed in 2D-digital subtraction angiography(DSA)during and immediately after implantation were observed,and superselective C-arm CT scanning of target artery and stent precision reconstruction were performed.Subjective scoring of display stent structure in 2D-DSA and stent precision reconstruction images were comparatively analyzed,and the clarity rate of displaying stent and detection rate of related complications were compared.Results Totally 45 stents were implanted in 38 patients.In 2D-DSA,the subjective score was 0 of 1,1 of 20 and 2 of 24 stents,respectively.Stent precision reconstruction image showed that subjective score was 0 of 1 stent and was 3 of 44 stents.The clarity rate of displaying stent in stent precision reconstruction image was 97.78%(44/45),much higher than that of 2D-DSA image(0[0/45],P<0.001).Among 44 stents displayed in 2D-DSA,poor stent opening and abnormal perforator vessel was observed in each 1 stent,and no clear abnormality was found in the rest stents.Among 44 stents revealed in stent precision reconstruction images,poor stent opening,thromboses in stent and stent mesh protruding into vascular lumen were found each in 2 stents,while perforator vessel spasm and localized stenosis after stent implantation were noticed in 3 stents.Arterial dissection occurred in 8 stents during balloon dilation,after timely implantation of a new stent,stent precision reconstruction images showed the dissection rupture was completely covered.The complications of stent precision reconstruction was higher than that of 2D-DSA(38.64%[17/44]vs.4.55%[2/44].P=0.002).Conclusion C-arm CT stent precision technique had obvious advantages for intracranial artery stent implantation.
3.Relationship of Subchondral Plate-Rod Structure and Cartilage Degeneration with Lower Limb Alignment
Xuequan HAN ; Kai XIE ; Xu JIANG ; Zihao HE ; Jingke DU ; Haishan WU ; Zhifeng YU ; Mengning YAN
Journal of Medical Biomechanics 2020;35(3):E364-E371
Objective To study the relationship of the tibial plateau subchondral trabecular bone (STB) microstructure and the cartilage degeneration with the lower limb alignment based on individual trabecula segmentation (ITS) and histology analysis in knee osteoarthritis (OA). Methods Hip-knee-ankle (HKA) angles were measured on the full-length lower extremity films of patients before total knee arthroplasty (TKA). The tibial plateau excised from the TKA were collected for micro-CT scanning and ITS analysis. The cartilage degeneration was evaluated by histology. The relationship between the HKA angle and the changes in microstructural parameters of STB and cartilage degeneration were analyzed. ResultsThe plate, rod and axial bone trabecular volume fraction (BV/TV, pBV/TV, pBV/TV), ratio of trabecular plate versus rod (P/R), plate trabecular number density (pTb.N), plate trabecular thickness (pTb.Th), trabecular plate surface area (pTb.S), trabecular rod length (rTb.L), and plate-plate and plate-rod junction density (P-P Junc.D, P-R Junc.D) of the subchondral bone of the tibial plateau were significantly related to the cartilage degeneration OARSI score and the HKA angle. The greater the deviation of the lower limb alignment, the greater the number of subchondral trabeculae, the thicker the trabeculae, the greater the bone mass, the stronger the connectivity, especially the plate trabeculae on the affected side of tibial plateau, and the higher the OARSI score of cartilage degeneration. Conclusions Abnormal lower limb alignment may cause abnormal microstructure of the plate and rod STB of the tibial plateau by changing the stress distribution of the knee, especially the significant increase and thickening of the plate trabecular and axial trabecular bone, which may be an important risk factor that further aggravates the degeneration of articular cartilage and the progress of OA. Therefore, lower limb alignment correction with surgical intervention and improving STB with bone metabolism agents may efficiently contribute to preventing cartilage damage and mitigate OA progression.
4.Effects of Senescence on Mechanical Response of Osteocyte
Journal of Medical Biomechanics 2019;34(3):E333-E338
Bone is a dynamic organ, and the morphology, structure and function of bone can vary with the size, direction and form of mechanical stimulation. Appropriate mechanical stimulation is the key to maintain the dynamic balance of bone formation and bone resorption. However, with aging, the senescence of bone tissues causes a series of changes, including bone microenvironment, osteocyte morphology, signaling pathways in the osteocyte, etc., which weakens its mechanical response ability and then leads to osteoporosis and other diseases. Therefore, it is of great significance to study how aging affects the mechanical response of osteocyte. This review mainly discusses the influence of aging on mechanical response of the osteocyte.
5.Effect of Light Emitting Diode Red Light Irradiation on Hyperlipidemia Rats
Jianli LU ; Cuixia LIU ; Yu YIN ; Jingke AN ; Zishan JIA
Chinese Journal of Rehabilitation Theory and Practice 2013;19(9):824-827
Objective To observe the effect of light emitting diode (LED) red light irradiation on serum lipid in experimental hyperlipidemia rats. Methods 36 healthy male Sprague-Dawley rats were randomly divided into normal control group (n=12) and hyperlipidemic model group (n=24). The normal group was fed with normal diet while the hyperlipidemic model group with fat-rich forage for 6 weeks. The hyperlipidemic model group rats were randomly divided into the hyperlipidemic control group (n=12) and LED treatment group (n=12), and the latter accepted LED red light irradiation for 28 d. The levels of serum lipid including total cholesterol (TC), triglyceride (TG), low-density lipoprotein (LDL-C), high-density lipoprotein (HDL-C), and the activities of lipoproteinesterase (LPL) and hepatic lipase (HL) were detected with biochemical assay. The expression of 3-hydroxy-3-methylglutaryl coenzyme A reducase (HMG-CR) of hepatic tissue were measured with immunohistochemical staining. Results Compared with the hyperlipidemic control group, the levels of serum TC, TG and LDL-C decreased while the serum HDL-C increased significantly in the LED treatment group (P<0.01) after treated with LED. The levels of LPL and HL in serum increased (P<0.01) while the activity of HMG-CR decreased (P<0.05). Conclusion LED red light irradiation might play a regulating effect on serum lipid by enhancing the activities of LPL and HL and inhibiting the expression of HMG-CR to interfere the metabolism of TC, TG, LDL-C and HDL-C.
6.Angiogenesis promoting effect of Morinda officinalis oligosaccharides on chicken embryo chorioallantoic membrane.
Jingke YANG ; Guoqing FENG ; Shuang YU ; Peng QIAO
China Journal of Chinese Materia Medica 2010;35(3):360-363
OBJECTIVETo study the angiogenesis promoting effect of Morinda officinalis oligosaccharides(MOO) on chick embryo chorioallantoic membrane (CAM).
METHODRats blood serum containing low, medium and high doses of MOO was prepared using Chinese herbs serum pharmacology method. 60 chick embryoes were randomly divided into low, medium and high doses of MOO groups, as well as NS group, blank serum group and bFGF group. Each group included 10 embryoes. CAM model was prepared after 7 days incubation. Then NS, blank serum, bFGF (2500 U x mL(-1)), three doses of serum containing MOO were added respectively onto the carriers on the CAM. CAM sample was prepared after 3 days incubation. The state of angiogenesis was observed and the number of new blood vessels was counted.
RESULTCompared with blank serum and NS group, a more specific CAM angiogenesis appearance could be observed in each MOO group and bFGF group. Compared with blank serum group, the number of new blood vessels in each MOO group increased significantly (P < 0.05). But the drug had a lower efficacy than bFGF (P < 0.05). Compared with low dose group, the number of new blood vessels increased significantly in medium and high doses groups (P < 0.05). But there was no significant difference between the latter two groups. The number of new blood vessels showed no significant difference between NS group and blank serum group.
CONCLUSIONMOO can obviously promote angiogenesis of CAM.
Animals ; Chick Embryo ; blood supply ; drug effects ; Chickens ; Chorioallantoic Membrane ; blood supply ; drug effects ; Drugs, Chinese Herbal ; pharmacology ; Female ; Male ; Morinda ; chemistry ; Neovascularization, Physiologic ; drug effects ; Oligosaccharides ; pharmacology
7.The angiogenic promoting effect of Morinda officinalis How oligosaccharides in the ischemic myocardium of rats after acute myocardial infarction
Jingke YANG ; Guoqing FENG ; Shuang YU ; Xiangjie HU
Chinese Pharmacological Bulletin 2010;26(3):367-371
Aim To investigate the angiogenic promoting effect of Morinda officinalis How oligosaccharides(MOO) in the ischemic myocardium of rats after acute myocardial infarction(AMI).Methods 40 male Wistar rats were established into AMI model successfully and were randomly divided into 5 groups equally, i. e. the low, medium and high doses of MOO groups, the Shexiangbaoxin group and the model group. They were treated with different doses of the water fraction of the ethanolic extract of Radix morinda officinalis (0.7, 1.4, 2.8 mg·kg~(-1) ·d~(-1)), suspension liquid of Shexiangbaoxin Pill(30 mg·kg~(-1) ·d~(-1)) and distilled water with the same volume respectively.Besides, a sham operated group with 10 rats was set up for control. All rats were sacrificed after 6-week-treatment.The Ⅷ coagulation factor, vascular endothelial growth factor(VEGF) and basic fibroblast growth factor(bFGF) protein in ischemic myocardium of rats in each group were detected by immunohistochemistry assay.The microvessel density(MVD) was calculated. Gray values of protein expression of VEGF and bFGF in ischemic myocardium were calculated and analyzed by image analysis system.Results The MVD, the gray values of VGF and bFGF were higher in the medium and high doses of MOO groups than those in the model group(P <0.05), but still lower than those in the Shexiangbaoxin group(P <0.05). The MVD and the gray values of VEGF among 3 doses of MOO groups showed significant differences (P <0.05).Significant differences of gray value of bFGF were observed between small and middle doses of MOO groups, also between small and large doses of groups(P <0.05).Conclusion MOO can obviously promote angiogenesis in the ischemic myocardium of the rats after AMI.And up-regulating expressions of VEGF and bFGF protein in the ischemic myocardium may act as one of its angiogenic promoting mechanisms.


Result Analysis
Print
Save
E-mail