1.Analysis on Quality Standard of Sennae Folium(Cassia angustifolia) Dispensing Granules Based on Standard Decoctions
Jinxin LI ; Xue DONG ; Shuai DUAN ; Guiyun CAO ; Jinghua ZHANG ; Yongfu LUAN ; Yongqiang LIN ; Xiaodi DONG ; Zhaoqing MENG
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(9):192-200
ObjectiveTo establish the quality standards for Sennae Folium(Cassia angustifolia) dispensing granules based on standard decoctions. MethodsHigh performance liquid chromatography(HPLC) specific chromatograms were established for 15 batches of Sennae Folium(C. angustifolia) standard decoctions and 10 of Sennae Folium(C. angustifolia) dispensing granules from different manufacturers, and the similarity evaluation, hierarchical cluster analysis(HCA) and principal component analysis(PCA) were performed. Linear calibration with two reference substances(LCTRS) and quantitative analysis of multi-components by single-marker(QAMS) were established for the common peaks in the specific chromatograms to determine the contents of main components in the decoction pieces, standard decoctions and dispensing granules, and to calculate their transfer rates from decoction pieces to standard decoctions and dispensing granules. ResultsThe similarities of specific chromatograms of 15 batches of Sennae Folium(C. angustifolia) standard decoctions and 10 batches of Sennae Folium(C. angustifolia) dispensing granules were all greater than 0.95, and a total of 8 characteristic peaks were calibrated, and five of them were identified, including kaempferol-3,7-O-diglucoside, apigenin-6,8-di-C-glucoside, quercetin-3-O-gentianoside, sennoside B and sennoside A. HCA and PCA results showed that there were certain differences in the composition of different batches of standard decoctions, but no clustering was observed in the production area. As the standard decoctions, the extract rate of 15 batches of samples was 26.54%-45.38%, the contents of kaempferol-3,7-O-diglucoside, apigenin-6,8-di-C-glucoside, quercetin-3-O-gentianoside, sennoside B and sennoside A were 12.16-19.26, 2.57-4.94, 3.27-5.11, 6.75-11.39, 4.69-7.79 mg·g-1, and their transfer rates from decoction pieces to standard decoctions were 45.41%-79.02%, 29.12%-55.07%, 40.52%-67.90%, 24.72%-49.12%, 27.54%-49.34%, respectively. The extract rates of Sennae Folium(C. angustifolia) dispensing granules(C8-C10) were 38.10%-39.50%, the transfer rates of the above five components from decoction pieces to dispensing granules were 72.85%-73.58%, 53.43%-53.94%, 40.19%-40.74%, 24.62%-25.00%, 28.65%-29.11%, respectively, which were generally consistent with the transfer rates from decoction pieces to standard decoctions. ConclusionCompared with the relative retention time method, LCTRS has higher prediction accuracy and is more suitable for chromatographic columns. The established quality control standard of Sennae Folium(C. angustifolia) dispensing granules based on standard decoction is reasonable and reliable, and all indicators of samples from different manufacturers are within the range specified based on the standard decoction, which can provide reference for the quality control and process research of this dispensing granules.
2.Analysis on Quality Standard of Hedyotis Herba Dispensing Granules Based on Standard Decoction
Jinghua ZHANG ; Nana WU ; Yanan LYU ; Guiyun CAO ; Jiacheng XU ; Yongqiang LIN ; Xiaodi DONG ; Jinxin LI ; Zhaoqing MENG
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(10):210-217
ObjectiveTo establish the specific chromatogram and quantitative analysis of multi-components by single-marker(QAMS) based on linear calibration using two reference substances(LCTRS), explore the consistency between Hedyotis Herba dispensing granules and standard decoction, and evaluate the quality of the dispensing granules. MethodsHigh performance liquid chromatography(HPLC) specific chromatogram was established based on 15 batches of Hedyotis Herba standard decoction and 10 batches of the dispensing granules, and LCTRS was used to locate chromatographic peaks. The actual retention times of 7 characteristic peaks in the specific chromatogram was measured on 24 different types of C18 columns, taking deacetyl asperulosidic acid and asperulosidic acid as the dual standard compounds, the retention times of the other 5 characteristic peaks were predicted and validated. Based on this, QAMS was developed to determine the contents of four components(deacetyl asperulosidic acid, deacetyl asperulosidic acid methyl ester, asperulosidic acid, and p-coumaric acid). Then, the relative correction factors of deacetyl asperulosidic acid, deacetyl asperulosidic acid methyl ester and p-coumaric acid were calculated using the reference peak of asperulosidic acid in the dual standard compounds, and each component was quantified accordingly. Finally, the consistency between the dispensing granules and standard decoction was assessed by taking extract rate of the standard decoction, consistency of the specific chromatograms, contents and transfer rates of the indicator components as indexes, and the quality of the dispensing granules was evaluated. ResultsThere were 7 common peaks in the characteristic chromatogram of samples of Hedyotis Herba standard decoction and the dispensing granules, and four of them were identified by reference standards, namely deacetyl asperulosidic acid(peak 1), deacetyl asperulosidic acid methyl ester(peak 3), asperulosidic acid(peak 6) and p-coumaric acid(peak 7). The similarity between the dispensing granules and the standard decoction was >0.9. The absolute deviation in the predicted retention time for each component by LCTRS was lower than that of the relative retention time method. The extract rate of the 15 batches of Hedyotis Herba standard decoction ranged from 7.89% to 14.60%, the contents of deacetyl asperulosidic acid, deacetyl asperulosidic acid methyl ester, asperulosidic acid and p-coumaric acid were 6.62-19.70, 3.83-17.99, 1.57-6.69, 1.62-4.52 mg·g-1, and the transfer rates of these components from decoction pieces to the standard decoction were 22.89%-39.60%, 34.03%-62.24%, 24.25%-43.70%, and 40.58%-73.71%, respectively. The extract rate, index component contents and transfer rates from decoction pieces to the three batches of Hedyotis Herba dispensing granules(P1-P3), produced by manufacturer A, were similar to those of the standard decoction prepared from the same batch of decoction pieces, and all fell within the specified range. The contents of the 4 indicator components in 7 batches of the dispensing granules(P4-P10) from manufacturers B-E were all within the range of the content converted from the standard decoction based on the quantity of the dispensing granules. ConclusionThe established specific chromatogram and QAMS based on LCTRS are reasonable and reliable. Based on the evaluation indicators of standard decoction yield, consistency of specific chromatograms, contents and transfer rates of the four index components, the 10 batches of Hedyotis Herba dispensing granules from various manufacturers have exhibited good consistency with the standard decoction, indicating that the current production process is relatively reasonable.
3.Quality Evaluation of Chuanxiong Rhizoma Dispensing Granules Based on HPLC Specific Chromatogram and Two Reference Substances for Determination of Multiple Components
Jinxin LI ; Xue DONG ; Shuai DUAN ; Guiyun CAO ; Jinghua ZHANG ; Yongfu LUAN ; Yongqiang LIN ; Xiaodi DONG ; Zhaoqing MENG
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(11):246-253
ObjectiveTo establish the specific chromatogram of Chuanxiong Rhizoma dispensing granules(CRdg), and to evaluate its quality by chemometrics and two reference substances for determination of multiple components(TRSDMC). MethodsHigh performance liquid chromatography(HPLC) specific chromatograms were established using 13 batches of CRdg from 7 manufacturers, and preliminary quality evaluation was performed by similarity evaluation and chemometrics analysis. Eight characteristic peaks in the specific chromatogram of CRdg were measured on 22 different types of C18 columns, and the actual retention times were recorded. Taking chlorogenic acid(peak 1) and senkyunolide A(peak 8) as double standard compounds, the retention times of the eight characteristic peaks were predicted by linear calibration using two reference substances(LCTRS), and the method was validated on three other columns of different brands. Taking chlorogenic acid as reference peak, the relative correction factor method(RCFM) was used to quantify cryptochlorogenic acid, caffeic acid, ferulic acid, senkyunolide I and senkyunolide A, and the results were compared with the external standard method(ESM). ResultsThe similarities of specific chromatograms of 13 batches of CRdg were all >0.90, and a total of 8 characteristic peaks were calibrated, and six of them were identified, including chlorogenic acid(peak 1), cryptochlorogenic acid(peak 2), caffeic acid(peak 3), ferulic acid(peak 5), senkyunolide I(peak 6) and senkyunolide A(peak 8). Through chemometric analysis, it was found that ferulic acid, chlorogenic acid, senkyunolide I and cryptochlorogenic acid were the main components causing quality difference in CRdg, and the accuracy of LCTRS in predicting the retention time of 8 characteristic peaks was superior to that of the relative retention time method(RRT). Further comparison of the results obtained from RCFM and ESM showed that there was no statistically significant difference between the two methods. ConclusionA quality evaluation method for CRdg based on HPLC specific chromatogram and TRSDMC is established, its qualitative accuracy is better than that of RRT, the quantitative accuracy is similar to that of ESM, and 4 quality-differentiated components among different manufacturers are found. This method is stable and reliable, and has reference value for the quality evaluation of other dispensing granules.
4.Quality Evaluation of Chuanxiong Rhizoma Dispensing Granules Based on HPLC Specific Chromatogram and Two Reference Substances for Determination of Multiple Components
Jinxin LI ; Xue DONG ; Shuai DUAN ; Guiyun CAO ; Jinghua ZHANG ; Yongfu LUAN ; Yongqiang LIN ; Xiaodi DONG ; Zhaoqing MENG
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(11):246-253
ObjectiveTo establish the specific chromatogram of Chuanxiong Rhizoma dispensing granules(CRdg), and to evaluate its quality by chemometrics and two reference substances for determination of multiple components(TRSDMC). MethodsHigh performance liquid chromatography(HPLC) specific chromatograms were established using 13 batches of CRdg from 7 manufacturers, and preliminary quality evaluation was performed by similarity evaluation and chemometrics analysis. Eight characteristic peaks in the specific chromatogram of CRdg were measured on 22 different types of C18 columns, and the actual retention times were recorded. Taking chlorogenic acid(peak 1) and senkyunolide A(peak 8) as double standard compounds, the retention times of the eight characteristic peaks were predicted by linear calibration using two reference substances(LCTRS), and the method was validated on three other columns of different brands. Taking chlorogenic acid as reference peak, the relative correction factor method(RCFM) was used to quantify cryptochlorogenic acid, caffeic acid, ferulic acid, senkyunolide I and senkyunolide A, and the results were compared with the external standard method(ESM). ResultsThe similarities of specific chromatograms of 13 batches of CRdg were all >0.90, and a total of 8 characteristic peaks were calibrated, and six of them were identified, including chlorogenic acid(peak 1), cryptochlorogenic acid(peak 2), caffeic acid(peak 3), ferulic acid(peak 5), senkyunolide I(peak 6) and senkyunolide A(peak 8). Through chemometric analysis, it was found that ferulic acid, chlorogenic acid, senkyunolide I and cryptochlorogenic acid were the main components causing quality difference in CRdg, and the accuracy of LCTRS in predicting the retention time of 8 characteristic peaks was superior to that of the relative retention time method(RRT). Further comparison of the results obtained from RCFM and ESM showed that there was no statistically significant difference between the two methods. ConclusionA quality evaluation method for CRdg based on HPLC specific chromatogram and TRSDMC is established, its qualitative accuracy is better than that of RRT, the quantitative accuracy is similar to that of ESM, and 4 quality-differentiated components among different manufacturers are found. This method is stable and reliable, and has reference value for the quality evaluation of other dispensing granules.
5.Nanoplastics and microplastics impair spatial memory ability in mice by inhibiting autophagy
Huimei LIANG ; Jiarui PAN ; Xueer LIN ; Minyi ZHAO ; Huan ZENG ; Yuqiang CHEN ; Hou-hui SONG ; Wei WANG ; Jinghua ZHAO
Chinese Journal of Veterinary Science 2025;45(10):2246-2255
Approximately 300 million tons of plastic are produced globally each year,which has a serious impact on human health,marine life and the livestock industry.Microplastics have also been detected in meat and milk samples.Research has shown that nanoplastics(NP)(<1 μm)and mi-croplastics(MP)(1 μm-5 mm)can affect the digestive,immune and reproductive systems of ani-mals.This experiment aims to investigate whether NP and MP regulate autophagy and damage the nervous system and spatial memory of animals.This experiment was divided into control group,nanoplastic group(PS-NP group,0.1 μm)and microplastic group(PS-MP group,1 μm),with 20 mice in each group.The mice were given 0.5 mL of PS-NP and PS-MP every day for 35 consecutive days,followed by neck amputation and brain analysis.The results showed that NPs and MPs of dif-ferent diameters caused varying degrees of damage to the brains of mice.In the behavioral tests of new object recognition,barnes maze and Y-shaped maze spatial memory,compared with the control group,the PS-NP group and PS-MP group showed a significant decrease in spatial memory ability of mice.HE staining results showed that neuronal cells in the PS-NP and PS-MP groups of mice exhibited shrinkage,decreased cell volume and deepened staining.The number of Nissl bodies de-creased,leading to dissolution and disappearance.RT-PCR and Western blot results showed that compared with the control group,the expression of glutamate receptors NR1,NR2A and NR2B in-creased in mice administered NP and MP orally,while the expression of autophagy related proteins Parkin,LC3B and Beclin1 was inhibited.In summary,this study suggests that nanoplastics and mi-croplastics stimulate glutamate receptors in mice by inhibiting the autophagy pathway,leading to impaired spatial memory.
6.Expert consensus on the difficult cannulation of hemodialysis arteriovenous fistula guided by point-of-care ultrasound
Lin CHEN ; Jinghua XIA ; Xia FU ; Zhifang MA ; Guanghui XIAO
Chinese Journal of Nursing 2025;60(19):2309-2313
Objective To formulate an expert consensus on the puncture of difficult arteriovenous fistula under real-time guidance of ultrasound(hereinafter referred to as the consensus).To standardize the clinical practice of ultrasound-guided puncture of difficult autologous arteriovenous fistula.Methods We conducted a comprehensive literature review of domestic and international publications,integrated clinical nursing experts' practical experience,and followed evidence-based nursing principles to identify the best available evidence.Through expert panel discussions and 3 rounds of Delphi expert consultation,we systematically revised,refined and improved the initial draft of the consensus,ultimately developing the finalized version.Results The response rates of the 3 rounds of Delphi expert correspondence inquiries were all 100%;the authority coefficient of expert correspondence inquiries was 0.97;the mean importance assignment of the 3 rounds of correspondence inquiries was more than 3.50.The Kendall coordination coefficients of the 3 rounds of expert consultation were 0.127,0.120,and 0.201,respectively(P<0.05),and the degree of coordination of expert opinions was good and the expert opinions were consistent.The consensus summarized 5 aspects,including relevant terms and definitions,indications for real-time ultrasound-guided arteriovenous fistula puncture,personnel qualifications and training,difficult arteriovenous fistula puncture procedures under real-time ultrasound-guided,and nursing quality control.Conclusion The consensus is scientific,which can provide a basis for hemodialysis practitioners to practice the puncture of difficult arteriovenous fistula under real-time guidance of ultrasound.
7.Expert consensus on the difficult cannulation of hemodialysis arteriovenous fistula guided by point-of-care ultrasound
Lin CHEN ; Jinghua XIA ; Xia FU ; Zhifang MA ; Guanghui XIAO
Chinese Journal of Nursing 2025;60(19):2309-2313
Objective To formulate an expert consensus on the puncture of difficult arteriovenous fistula under real-time guidance of ultrasound(hereinafter referred to as the consensus).To standardize the clinical practice of ultrasound-guided puncture of difficult autologous arteriovenous fistula.Methods We conducted a comprehensive literature review of domestic and international publications,integrated clinical nursing experts' practical experience,and followed evidence-based nursing principles to identify the best available evidence.Through expert panel discussions and 3 rounds of Delphi expert consultation,we systematically revised,refined and improved the initial draft of the consensus,ultimately developing the finalized version.Results The response rates of the 3 rounds of Delphi expert correspondence inquiries were all 100%;the authority coefficient of expert correspondence inquiries was 0.97;the mean importance assignment of the 3 rounds of correspondence inquiries was more than 3.50.The Kendall coordination coefficients of the 3 rounds of expert consultation were 0.127,0.120,and 0.201,respectively(P<0.05),and the degree of coordination of expert opinions was good and the expert opinions were consistent.The consensus summarized 5 aspects,including relevant terms and definitions,indications for real-time ultrasound-guided arteriovenous fistula puncture,personnel qualifications and training,difficult arteriovenous fistula puncture procedures under real-time ultrasound-guided,and nursing quality control.Conclusion The consensus is scientific,which can provide a basis for hemodialysis practitioners to practice the puncture of difficult arteriovenous fistula under real-time guidance of ultrasound.
8.Nanoplastics and microplastics impair spatial memory ability in mice by inhibiting autophagy
Huimei LIANG ; Jiarui PAN ; Xueer LIN ; Minyi ZHAO ; Huan ZENG ; Yuqiang CHEN ; Hou-hui SONG ; Wei WANG ; Jinghua ZHAO
Chinese Journal of Veterinary Science 2025;45(10):2246-2255
Approximately 300 million tons of plastic are produced globally each year,which has a serious impact on human health,marine life and the livestock industry.Microplastics have also been detected in meat and milk samples.Research has shown that nanoplastics(NP)(<1 μm)and mi-croplastics(MP)(1 μm-5 mm)can affect the digestive,immune and reproductive systems of ani-mals.This experiment aims to investigate whether NP and MP regulate autophagy and damage the nervous system and spatial memory of animals.This experiment was divided into control group,nanoplastic group(PS-NP group,0.1 μm)and microplastic group(PS-MP group,1 μm),with 20 mice in each group.The mice were given 0.5 mL of PS-NP and PS-MP every day for 35 consecutive days,followed by neck amputation and brain analysis.The results showed that NPs and MPs of dif-ferent diameters caused varying degrees of damage to the brains of mice.In the behavioral tests of new object recognition,barnes maze and Y-shaped maze spatial memory,compared with the control group,the PS-NP group and PS-MP group showed a significant decrease in spatial memory ability of mice.HE staining results showed that neuronal cells in the PS-NP and PS-MP groups of mice exhibited shrinkage,decreased cell volume and deepened staining.The number of Nissl bodies de-creased,leading to dissolution and disappearance.RT-PCR and Western blot results showed that compared with the control group,the expression of glutamate receptors NR1,NR2A and NR2B in-creased in mice administered NP and MP orally,while the expression of autophagy related proteins Parkin,LC3B and Beclin1 was inhibited.In summary,this study suggests that nanoplastics and mi-croplastics stimulate glutamate receptors in mice by inhibiting the autophagy pathway,leading to impaired spatial memory.
9.Progress in the application of deep learning in prognostic models for non-small cell lung cancer
Ruikang ZHONG ; Jinghua LI ; Ximing LIN ; Xueni FANG ; Kaiwen HU ; Tian ZHOU
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2024;31(09):1345-1350
Non-small cell lung cancer is one of the cancers with the highest incidence and mortality rate in the world, and precise prognostic models can guide clinical treatment plans. With the continuous upgrading of computer technology, deep learning as a breakthrough technology of artificial intelligence has shown good performance and great potential in the application of non-small cell lung cancer prognosis model. The research on the application of deep learning in survival and recurrence prediction, efficacy prediction, distant metastasis prediction, and complication prediction of non-small cell lung cancer has made some progress, and it shows a trend of multi-omics and multi-modal joint, but there are still shortcomings, which should be further explored in the future to strengthen model verification and solve practical problems in clinical practice.
10.Platinum-Based Nanoplatforms in the Application of Medical Multimodal Imaging
Heying LI ; Jingpi GAO ; Pengshan GUO ; Qinghao HE ; Manping LIN ; Shuo GU ; Jinghua LI
Chinese Journal of Medical Imaging 2024;32(1):105-108,112
Platinum-based nanoplatforms can enhance the absorption of X-ray due to the presence of high atomic number element of platinum and are applied to computed tomography imaging.Meanwhile,platinum-based nanomaterials have good near-infrared light absorption properties and photothermal conversion efficiency,which make them capable of photothermal imaging and photoacoustic imaging.In addition,by reducing transverse and longitudinal relaxation time,platinum-based nanoplatforms can mediate MRI imaging.In this paper,we report a multimodal imaging system based on platinum-based nanoplatforms for guiding the development of cancer treatment and diagnosis platform and medical application research,and also summarize the prospects of multimodal imaging technology in cancer diagnosis and treatment,report the research progress of platinum-based nanoplatforms in improving the contrast of medical images and enhancing cancer treatment.

Result Analysis
Print
Save
E-mail