1.Tongue squamous cell carcinoma-targeting Au-HN-1 nanosystem for CT imaging and photothermal therapy.
Ming HAO ; Xingchen LI ; Xinxin ZHANG ; Boqiang TAO ; He SHI ; Jianing WU ; Yuyang LI ; Xiang LI ; Shuangji LI ; Han WU ; Jingcheng XIANG ; Dongxu WANG ; Weiwei LIU ; Guoqing WANG
International Journal of Oral Science 2025;17(1):9-9
Tongue squamous cell carcinoma (TSCC) is a prevalent malignancy that afflicts the head and neck area and presents a high incidence of metastasis and invasion. Accurate diagnosis and effective treatment are essential for enhancing the quality of life and the survival rates of TSCC patients. The current treatment modalities for TSCC frequently suffer from a lack of specificity and efficacy. Nanoparticles with diagnostic and photothermal therapeutic properties may offer a new approach for the targeted therapy of TSCC. However, inadequate accumulation of photosensitizers at the tumor site diminishes the efficacy of photothermal therapy (PTT). This study modified gold nanodots (AuNDs) with the TSCC-targeting peptide HN-1 to improve the selectivity and therapeutic effects of PTT. The Au-HN-1 nanosystem effectively targeted the TSCC cells and was rapidly delivered to the tumor tissues compared to the AuNDs. The enhanced accumulation of photosensitizing agents at tumor sites achieved significant PTT effects in a mouse model of TSCC. Moreover, owing to its stable long-term fluorescence and high X-ray attenuation coefficient, the Au-HN-1 nanosystem can be used for fluorescence and computed tomography imaging of TSCC, rendering it useful for early tumor detection and accurate delineation of surgical margins. In conclusion, Au-HN-1 represents a promising nanomedicine for imaging-based diagnosis and targeted PTT of TSCC.
Tongue Neoplasms/diagnostic imaging*
;
Carcinoma, Squamous Cell/diagnostic imaging*
;
Animals
;
Gold/chemistry*
;
Mice
;
Photothermal Therapy/methods*
;
Tomography, X-Ray Computed
;
Photosensitizing Agents
;
Metal Nanoparticles
;
Humans
;
Cell Line, Tumor
2.Efficacy analysis of modified endoscopic autologous cartilage eustachian tube pharyngeal orifice tubo-plasty on patulous eustachian tube
Jingcheng ZHOU ; Zhenhao FU ; Fangyuan WANG ; Jianping JIA ; Danheng ZHAO ; Ya LIU ; Li ZHU ; Kun HOU ; Mengyuan GUO ; Haoze ZHANG ; Yulin DING ; Xiaolong LI ; Zhaohui HOU
Journal of Audiology and Speech Pathology 2025;33(5):418-423
Objective This study aimed to investigate the efficacy of modified endoscopic autologous cartilage eustachian tube pharyngeal orifice tuboplasty(MEACETT)in patients with patulous eustachian tube(PET).Meth-ods A retrospective analysis was conducted on the clinical data of 27 patients(30 ears)diagnosed with PET who underwent MEACETT.Autologous cartilage was used through the incision at the posterior end of the inferior turbi-nate and filled into the lateral wall of the pharyngeal orifice of the eustachian tube.Without affecting the movement function of the eustachian tube during swallowing,the collapse of the pharyngeal orifice was fully filled.Before and after the surgery,the visual analogue scale(VAS),the eustachian tube dysfunction questionnaire-7(ETDQ-7)and hospital anxiety and depression scale(HADS)was used for assessment to evaluate the surgical efficacy.Results There was no significant difference in depression scores before and after surgery(P>0.05).However,postopera-tive anxiety scores,ETDQ-7 scores,and VAS scores were significantly lower than preoperative scores(P<0.05).Among the 27 patients,9 showed significant symptom relief,13 exhibited partial relief,and 5 had no significant change compared to preoperative symptoms.The overall response rate of the treatment(significant relief and partial relief)was 81.48%(22/27).All surgeries were successfully performed.Except for secretory otitis media occurring in 2 cases,no major complications were observed.Conclusion MEACETT demonstrates significant symptom relief in PET patients,with high surgical safety and low complication rates,making it worthy of clinical promotion.
3.Research on the diagnostic efficiency of the"R"value of tubomanometry in detecting patulous eusta-chian tube
Zhenhao FU ; Jingcheng ZHOU ; Jianping JIA ; Fangyuan WANG ; Danheng ZHAO ; Ya LIU ; Haoze ZHANG ; Mengyuan GUO ; Li ZHU ; Kun HOU ; Yulin DING ; Xiaolong LI ; Zhaohui HOU
Journal of Audiology and Speech Pathology 2025;33(5):429-433
Objective To evaluate the diagnostic efficacy of the R value in tubomanometry(TMM)for the di-agnosis of patulous eustachian tube(PET).Methods The clinical data of 58 patients with PET and 65 controls were retrospectively analyzed.TMM was performed on both groups under nasopharyngeal pressures of 30,40,and 50 mbar respectively.The diagnostic efficacy of the R value for PET was evaluated through receiver operating char-acteristic(ROC)curves.Results In the control group,the average R values under nasopharyngeal pressures of 30,40,and 50 mbar were 0.86±0.50,0.76±0.41,and 0.68±0.34 respectively.In contrast,the corresponding R values in the PET group were significantly lower,which were 0.56±0.38,0.50±0.36,and 0.46±0.38 respec-tively.According to the ROC curve analysis,the areas under the curve(AUC)at these pressures were 0.62,0.74,and 0.74 respectively.The specificity and sensitivity of the R value under nasopharyngeal pressures of 30,40,and 50 mbar were 76.90%and 54.30%,74.60%and 68.10%,86.90%and 54.30%,respectively.Under pressures of 30,40,and 50 mbar,the incidence rates of R>1 in the control group and the PET group were 29.23%(38/130)and 12.77%(12/94)(x2=8.69,P=0.003),20.00%(26/130)and 6.38%(6/94)(x2=7.20,P=0.007),10.00%(13/130)and 3.19%(3/94)(x2=2.87,P=0.09)respectively.Conclusion Although the low R value in TMM reflects the presence of PET to some extent,it does not provide adequate sensitivity and specificity to serve as an independent diagnostic criterion for PET.
4.Efficacy analysis of modified endoscopic autologous cartilage eustachian tube pharyngeal orifice tubo-plasty on patulous eustachian tube
Jingcheng ZHOU ; Zhenhao FU ; Fangyuan WANG ; Jianping JIA ; Danheng ZHAO ; Ya LIU ; Li ZHU ; Kun HOU ; Mengyuan GUO ; Haoze ZHANG ; Yulin DING ; Xiaolong LI ; Zhaohui HOU
Journal of Audiology and Speech Pathology 2025;33(5):418-423
Objective This study aimed to investigate the efficacy of modified endoscopic autologous cartilage eustachian tube pharyngeal orifice tuboplasty(MEACETT)in patients with patulous eustachian tube(PET).Meth-ods A retrospective analysis was conducted on the clinical data of 27 patients(30 ears)diagnosed with PET who underwent MEACETT.Autologous cartilage was used through the incision at the posterior end of the inferior turbi-nate and filled into the lateral wall of the pharyngeal orifice of the eustachian tube.Without affecting the movement function of the eustachian tube during swallowing,the collapse of the pharyngeal orifice was fully filled.Before and after the surgery,the visual analogue scale(VAS),the eustachian tube dysfunction questionnaire-7(ETDQ-7)and hospital anxiety and depression scale(HADS)was used for assessment to evaluate the surgical efficacy.Results There was no significant difference in depression scores before and after surgery(P>0.05).However,postopera-tive anxiety scores,ETDQ-7 scores,and VAS scores were significantly lower than preoperative scores(P<0.05).Among the 27 patients,9 showed significant symptom relief,13 exhibited partial relief,and 5 had no significant change compared to preoperative symptoms.The overall response rate of the treatment(significant relief and partial relief)was 81.48%(22/27).All surgeries were successfully performed.Except for secretory otitis media occurring in 2 cases,no major complications were observed.Conclusion MEACETT demonstrates significant symptom relief in PET patients,with high surgical safety and low complication rates,making it worthy of clinical promotion.
5.Research on the diagnostic efficiency of the"R"value of tubomanometry in detecting patulous eusta-chian tube
Zhenhao FU ; Jingcheng ZHOU ; Jianping JIA ; Fangyuan WANG ; Danheng ZHAO ; Ya LIU ; Haoze ZHANG ; Mengyuan GUO ; Li ZHU ; Kun HOU ; Yulin DING ; Xiaolong LI ; Zhaohui HOU
Journal of Audiology and Speech Pathology 2025;33(5):429-433
Objective To evaluate the diagnostic efficacy of the R value in tubomanometry(TMM)for the di-agnosis of patulous eustachian tube(PET).Methods The clinical data of 58 patients with PET and 65 controls were retrospectively analyzed.TMM was performed on both groups under nasopharyngeal pressures of 30,40,and 50 mbar respectively.The diagnostic efficacy of the R value for PET was evaluated through receiver operating char-acteristic(ROC)curves.Results In the control group,the average R values under nasopharyngeal pressures of 30,40,and 50 mbar were 0.86±0.50,0.76±0.41,and 0.68±0.34 respectively.In contrast,the corresponding R values in the PET group were significantly lower,which were 0.56±0.38,0.50±0.36,and 0.46±0.38 respec-tively.According to the ROC curve analysis,the areas under the curve(AUC)at these pressures were 0.62,0.74,and 0.74 respectively.The specificity and sensitivity of the R value under nasopharyngeal pressures of 30,40,and 50 mbar were 76.90%and 54.30%,74.60%and 68.10%,86.90%and 54.30%,respectively.Under pressures of 30,40,and 50 mbar,the incidence rates of R>1 in the control group and the PET group were 29.23%(38/130)and 12.77%(12/94)(x2=8.69,P=0.003),20.00%(26/130)and 6.38%(6/94)(x2=7.20,P=0.007),10.00%(13/130)and 3.19%(3/94)(x2=2.87,P=0.09)respectively.Conclusion Although the low R value in TMM reflects the presence of PET to some extent,it does not provide adequate sensitivity and specificity to serve as an independent diagnostic criterion for PET.
6.Correlation between human leukocyte antigen HLA-A gene polymorphism and HBV carrier
Li SHUAI ; Shuai YANG ; Junjie YE ; Jingcheng YANG ; Xiaoye FU ; Bin XU ; Hongwei LIU ; Lü ZHOU ; Xilin KANG ; Jing GAO
Journal of Xi'an Jiaotong University(Medical Sciences) 2024;45(6):1037-1040
[Objective] To investigate the correlation between human leukocyte antigen (HLA) gene polymorphism and hepatitis B virus (HBV) infection. [Methods] Venous blood samples were collected from 501 healthy individuals undergoing physical examinations at Yan’an Hospital in Kunming, Yunnan Province. Enzyme linked immunosorbent assay (ELISA) was used to detect HBV halves. Based on the results of HBV half detection, the patients were divided into three groups: HBV carrier group, previous infection group, and healthy control group. The HLA-A antigen genotype was detected using polymerase chain reaction with sequence specific primers (PCR-SSP) genotyping technology, and the distribution frequency of HLA-A gene polymorphism was compared between HBV carrier group and healthy control group, as well as between previous infection group and healthy control group. SPSS17.0 software was used for data statistical analysis. [Results] In the healthy control group, the HLA-A2 positivity rate was 47.49%, and the allele frequency was 31.29%.The overall frequency of gene distribution in the healthy control group was consistent with the HLA-A allele table commonly and confirmed in China published by the Chinese Bone Marrow Bank. The HLA-A2 positivity rate and allele frequency in the HBV carrier group were 63.04% and 42.23%, respectively; The difference in HLA-A2 positivity rate and allele frequency among carriers was statistically significant (P<0.05). the HLA-A2 positivity rate and allele frequency in the HBV previous infection group were 56.14% and 35.97%, respectively, which did not significantly differ from those in the healthy control group (P>0.05). [Conclusion] HLA-A2 gene may be a susceptibility gene for chronic hepatitis B HBV carriers.
7.Aortic-mitral annular enlargement technique in re-valve surgery: A retrospective study in a single center
Mingyuan YANG ; Wenhao LIU ; Laichun SONG ; Jingcheng WU ; Liang TAO
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2024;31(06):826-831
Objective To investigate and evaluate the safety and efficacy of the aortic-mitral annular enlargement technique (double annular enlargement) in patients with small-size valve prostheses after prior valve surgery. Methods The clinical data of patients who underwent double valve annular enlargement in Wuhan Asia Heart Hospital from April 2020 to April 2022 were retrospectively analyzed. Results A total of 30 patients were collected, including 2 males and 28 females aged 9-78 (52.71±3.53) years. All patients had previous heart valve surgery, including 1 patient receiving the third heart surgery. All patients were operated on successfully and there were no postoperative in-hospital deaths. There was no postoperative bleeding which needed a secondary open-chest hemostasis, and one patient underwent permanent pacemaker implantation due to postoperative sick sinus syndrome. The mean diameter of the implanted prosthetic aortic valve was 24.23±1.60 mm, which was significantly larger than that of the preoperative aortic valve (21.03±1.90 mm, P<0.001). The mean diameter of the implanted prosthetic mitral valve was 28.33±1.21 mm, which was significantly larger than that of the preoperative mitral valve (25.43±0.84 mm, P<0.001). The mean peak gradient difference across the prosthetic aortic valve on postoperative echocardiography was 18.17±6.44 mm Hg, which was significantly lower than that of the preoperative aortic valve (82.57±24.48 mm Hg, P<0.001). The mean peak gradient difference of the postoperative prosthetic mitral valve was 12.73±5.45 mm Hg, which was significantly lower than that of the preoperative mitral valve (19.43±8.97 mm Hg, P=0.003). Conclusion The double annular enlargement technique is safe and effective for reoperation in patients with a history of valve surgery with a small aortic root to obtain both a larger size prosthetic valve for a larger orifice area and stability of the mitral-aortic valve union, resulting in good postoperative hemodynamic characteristics and clinical outcomes.
8.Formulation and Analysis on the Standard of Automation and Information Technology
Xun YU ; Jiancun ZHEN ; Liyan MIAO ; Zongqi CHENG ; Wei ZHANG ; Rongsheng ZHAO ; Lan ZHANG ; Xiaoyang LU ; Jian ZHANG ; Dong LIU ; Aizong SHEN ; Weihua LAI ; Jingcheng HE
Herald of Medicine 2024;43(7):1074-1078
To improve patient-centered pharmaceutical management and pharmaceutical service capabilities in the pharmaceutical department of medical institutions,automation and information technology are indispensable.The Pharmacy Administration-Automation and Information Technology is one of the social organization standards of the Chinese Hospital Association as part 4-4 of Pharmaceutical Administration and Pharmaceutical Practice in Healthcare,which standardizes 32 key elements in four aspects:basic requirements for automation construction in medical institutions,construction of automation hardware equipment,construction of intelligent information platform,and quality management and continuous improvement.It can be used to guide medical institutions at all levels to select and optimize pharmacy automation equipment and information platforms.This article introduced the construction methods and contents of the pharmacy automation and information technology standards,to deepen the understanding of peers on this standard and promote its implementation.This article aimed to promote the modernization,informatization,and intelligence of pharmaceutical services in medical institutions,and improve the quality and efficiency of overall medical pharmaceutical administration and service.
9.Application of Chimney technique in mitral valve reoperation: A retrospective study in a single center
Wenhao LIU ; Laichun SONG ; Mingyuan YANG ; Jingcheng WU ; Liang TAO
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2024;31(05):757-761
Objective To investigate and evaluate the safety and effectiveness of the Chimney technique in mitral valve reoperation. Methods The clinical data of mitral valve reoperation patients who underwent Chimney surgery in Wuhan Asia Heart Hospital from 2019 to 2021 were retrospectively analyzed. Results A total of 26 patients were collected, including 7 males and 19 females, aged 27-67 (53.46±11.18) years. All patients had previous mitral valve surgery, including 23 mitral valve replacements and 3 mitral valve repairs. All patients received Chimney technique using the ideal artificial sized mitral valve, and 1 patient died of neurological complications in hospital. The cardiopulmonary bypass time and the aortic cross-clamping time were 231.11±77.05 min and 148.50±52.70 min, respectively. The mean diameter of the implanted mitral valve prosthesis was 29.08±0.68 mm, which was statistically different from pre-replacement valve prosthesis size of 26.69±0.77 mm (P<0.001). The mean transvalvular pressure gradient of the prosthetic mitral valve measured on postoperative echocardiography was 14.77±5.34 mm Hg, which was statistically different from preoperative value of 20.92±9.83 mm Hg (P=0.005). Conclusion The Chimney technique is safe and effective for reoperation in patients with small mitral annuli, which can not only reduce the risk of reoperation, but also obtain larger prosthetic valve implants with good hemodynamic characteristics and clinical outcomes.
10.Nutritional literacy of school age children in grades 4-9 and its relationship with physical health in Guizhou Province
XIE Jingcheng, WANG Huiqun, YU Huixian, LIU Tao, HE Lin, LIU Yiya, LIU Jing
Chinese Journal of School Health 2024;45(5):649-653
Objective:
To understand the level of nutritional literacy and its influencing factors among schoolage children in grades 4-9 in Guizhou Province, and to explore the relationship between nutritional literacy and physical health, so as to provide reference for improving nutritional literacy and physical health of schoolage children.
Methods:
Using multistage stratified cluster sampling method, 1 155 schoolage children in grades 4-6 in elementary school and grades 7-9 in secondary schools in three prefectural and municipal cities of Guizhou Province (Zunyi, Tongren, and Bijie) were sampled from February to July 2023, and were surveyed for nutritional literacy by using the "Food and Nutritional Literacy Questionnaire for Chinese Schoolage Children", and their physical health data (data on body measurement indicators, such as height, weight, lung capacity, and vertical jump) were obtained from the physical health surveillance platform. Pearson correlation analysis and binary Logistic regression modeling were used to explore the association between nutritional literacy and physical health.
Results:
The nutritional literacy score of the study population was (63.50±8.63), and the scores of each level of nutritional literacy in descending order were interactivity (66.09±13.99), functionality (63.84±8.80), and criticism (61.15±14.65); and the scores of cognitive domain of nutritional literacy, and skill domain were (64.71±10.77) (62.97±9.21); food selection, food preparation, and food intake dimension scores were (64.68±13.52) (56.39±12.17) (63.63±10.04), respectively. Differences in the total nutritional literacy scores of schoolaged children who were only children or not, by gender, ethnicity, grade level, primary caregiver, primary caregivers education, and family economic situation were statistically significant (t/F=2.88, -3.28, 5.02, 18.32, 4.67, 32.47, 32.53, P<0.05); the physical health pass rate was 85.8%, and the mean scores of the total physical health score, physical form, physical function, and physical fitness dimensions were (71.86±10.52) (93.29±12.06) (72.12±14.42) (67.26±13.13), respectively; after controlling for confounders, the nutritional literacy scores were positively correlated with physical health (OR=1.03, 95%CI=1.01-1.05, P<0.05).
Conclusion
Nutritional literacy scores of schoolage children in grades 4-9 in Guizhou Province are low, and there is a positive correlation between nutritional literacy and physical health in this school age children.


Result Analysis
Print
Save
E-mail