1.Percutaneous coronary intervention vs . medical therapy in patients on dialysis with coronary artery disease in China.
Enmin XIE ; Yaxin WU ; Zixiang YE ; Yong HE ; Hesong ZENG ; Jianfang LUO ; Mulei CHEN ; Wenyue PANG ; Yanmin XU ; Chuanyu GAO ; Xiaogang GUO ; Lin CAI ; Qingwei JI ; Yining YANG ; Di WU ; Yiqiang YUAN ; Jing WAN ; Yuliang MA ; Jun ZHANG ; Zhimin DU ; Qing YANG ; Jinsong CHENG ; Chunhua DING ; Xiang MA ; Chunlin YIN ; Zeyuan FAN ; Qiang TANG ; Yue LI ; Lihua SUN ; Chengzhi LU ; Jufang CHI ; Zhuhua YAO ; Yanxiang GAO ; Changan YU ; Jingyi REN ; Jingang ZHENG
Chinese Medical Journal 2025;138(3):301-310
BACKGROUND:
The available evidence regarding the benefits of percutaneous coronary intervention (PCI) on patients receiving dialysis with coronary artery disease (CAD) is limited and inconsistent. This study aimed to evaluate the association between PCI and clinical outcomes as compared with medical therapy alone in patients undergoing dialysis with CAD in China.
METHODS:
This multicenter, retrospective study was conducted in 30 tertiary medical centers across 12 provinces in China from January 2015 to June 2021 to include patients on dialysis with CAD. The primary outcome was major adverse cardiovascular events (MACE), defined as a composite of cardiovascular death, non-fatal myocardial infarction, and non-fatal stroke. Secondary outcomes included all-cause death, the individual components of MACE, and Bleeding Academic Research Consortium criteria types 2, 3, or 5 bleeding. Multivariable Cox proportional hazard models were used to assess the association between PCI and outcomes. Inverse probability of treatment weighting (IPTW) and propensity score matching (PSM) were performed to account for potential between-group differences.
RESULTS:
Of the 1146 patients on dialysis with significant CAD, 821 (71.6%) underwent PCI. After a median follow-up of 23.0 months, PCI was associated with a 43.0% significantly lower risk for MACE (33.9% [ n = 278] vs . 43.7% [ n = 142]; adjusted hazards ratio 0.57, 95% confidence interval 0.45-0.71), along with a slightly increased risk for bleeding outcomes that did not reach statistical significance (11.1% vs . 8.3%; adjusted hazards ratio 1.31, 95% confidence interval, 0.82-2.11). Furthermore, PCI was associated with a significant reduction in all-cause and cardiovascular mortalities. Subgroup analysis did not modify the association of PCI with patient outcomes. These primary findings were consistent across IPTW, PSM, and competing risk analyses.
CONCLUSION
This study indicated that PCI in patients on dialysis with CAD was significantly associated with lower MACE and mortality when comparing with those with medical therapy alone, albeit with a slightly increased risk for bleeding events that did not reach statistical significance.
Humans
;
Percutaneous Coronary Intervention/methods*
;
Male
;
Female
;
Coronary Artery Disease/drug therapy*
;
Retrospective Studies
;
Renal Dialysis/methods*
;
Middle Aged
;
Aged
;
China
;
Proportional Hazards Models
;
Treatment Outcome
2.Elemene as a binding stabilizer of microRNA-145-5p suppresses the growth of non-small cell lung cancer.
Meirong ZHOU ; Jiayue WANG ; Yulin PENG ; Xiangge TIAN ; Wen ZHANG ; Junlin CHEN ; Yue WANG ; Yu WANG ; Youjian YANG ; Yongwei ZHANG ; Xiaokui HUO ; Yuzhuo WU ; Zhenlong YU ; Tian XIE ; Xiaochi MA
Journal of Pharmaceutical Analysis 2025;15(3):101118-101118
Elemene is widely recognized as an effective anti-cancer compound and is routinely administered in Chinese clinical settings for the management of several solid tumors, including non-small cell lung cancer (NSCLC). However, its detailed molecular mechanism has not been adequately demonstrated. In this research, it was demonstrated that elemene effectively curtailed NSCLC growth in the patient-derived xenograft (PDX) model. Mechanistically, employing high-throughput screening techniques and subsequent biochemical validations such as microscale thermophoresis (MST), microRNA-145-5p (miR-145-5p) was pinpointed as a critical target through which elemene exerts its anti-tumor effects. Interestingly, elemene serves as a binding stabilizer for miR-145-5p, demonstrating a strong binding affinity (dissociation constant (K D) = 0.39 ± 0.17 μg/mL) and preventing its degradation both in vitro and in vivo, while not interfering with the synthesis of the primary microRNA transcripts (pri-miRNAs) and precursor miRNAs (pre-miRNAs). The stabilization of miR-145-5p by elemene resulted in an increased level of this miRNA, subsequently suppressing NSCLC progression through the miR-145-5p/mitogen-activated protein kinase kinase kinase 3 (MAP3K3)/nuclear factor kappaB (NF-κB) pathway. Our findings provide a new perspective on revealing the interaction patterns between clinical anti-tumor drugs and miRNAs.
3.Effect of measurement site on diagnostic performance of CT-derived fractional flow reserve
Yutao ZHOU ; Na ZHAO ; Yunqiang AN ; Lei SONG ; Chaowei MU ; Jingang CUI ; Tao JIANG ; Li XU ; Hongjie HU ; Lin LI ; Dumin LI ; Wenqiang CHEN ; Lijuan FAN ; Feng ZHANG ; Yang GAO ; Bin LYU
Chinese Journal of Radiology 2025;59(6):704-711
Objective:To investigate the effect of CT-derived fractional flow reserve (CT-FFR) measurement sites on the values and the diagnostic performance, and to determine the optimal measurement site for CT-FFR using invasive FFR as the reference standard.Methods:This study was part of the CT-FFR CHINA clinical trial. Patients with suspected coronary artery disease who were scheduled for invasive coronary angiography (ICA) were prospectively recruited from five clinical centers across the country from November 2018 to March 2020. Each enrolled patient underwent coronary CT angiography (CCTA), CT-FFR, ICA, and invasive pressure wire-based FFR assessments sequentially within one week. Four groups of CT-FFR values were obtained on each enrolled target vessels according to different CT-FFR measurement locations: 1, 2, 3 cm distal to the target lesion, and terminal vessel groups. Spearman and Bland-Altman analyses were used to explore the correlation and consistency of CT-FFR values and FFR values at different measurement sites. The measurement deviation of CT-FFR was also compared. Diagnostic accuracy and performance of CT-FFR, including sensitivity, specificity, positive predictive value, negative predictive value, and area under the receiver operating characteristic curve (AUC), in discriminating myocardial ischemia were analyzed across all measurement site groups on a per-vessel level, using FFR as the reference standard.Results:A total of 289 patients with 345 target lesion vessels were included. According to CCTA, there were 51 target vessels (14.8%) with<50% stenosis, 106 vessels (30.7%) with 50%-69% stenosis, and 188 vessels (54.5%) with stenosis≥70%. At per-vessel level, CT-FFR and FFR values at each measurement position group were highly positively correlated: 1 cm distal to target lesion group, r=0.734 ( P<0.001); 2 cm distal to target lesion group, r=0.732 ( P<0.001); 3 cm distal to target lesion group, r=0.737 ( P<0.001); terminal vessel group was 0.719 ( P<0.001). At per-vessel level, CT-FFR and FFR values of all measurement sites were in good agreement (Bland-Altman analysis results): 1 cm distal to target lesion group, 0.014 (95% LoA 0.002-0.026); 2 cm distal to target lesion group, 0.026 (95% LoA 0.015-0.038); 3 cm distal to target lesion group, 0.040 (95% LoA 0.039-0.051); terminal vessel group, 0.075 (95% LoA 0.064-0.087). And at per-vessel level, the accuracy of diagnosing myocardial ischemia with CT-FFR at 1 cm was highest [84.6% (95% CI 80.4%-88.3%)], and the lowest accuracy in the terminal vessel group [67.0% (95% CI 61.7%-72.0%)]. However, there was no significant difference in the diagnostic accuracy of CT-FFR at 1 cm, 2 cm [80.6% (95% CI 76.1%-84.6%)] and 3 cm [77.5% (95% CI 72.6%-81.7%)]. AUC of CT-FFR at 1 cm distal to the lesion were both highest for global level and moderately stenosis (50%-69%) lesions [0.85 (95% CI 0.81-0.89), 0.84 (95% CI 0.77-0.90)]. And the differences were statistically significant among the four measurement location groups (all P<0.05). Conclusions:The deviation of CT-FFR increases with measurement site distance distal to target lesions. One centimeter distal to the target lesion is the optimal measurement site, and the CT-FFR value here shows the highest diagnostic performance for myocardial ischemic lesions, especially for moderate stenosis.
4.Effects of freeze-drying and dry heat virus inactivation processes on the biological activities of human plasma derived α2-macroglobulin
Teng FENG ; Fangling QI ; Qiang WANG ; Rui WANG ; Shaowei WANG ; Junting JIA ; Chongwei CHEN ; Jingang ZHANG ; Fang YUAN ; Yuyuan MA
Military Medical Sciences 2025;49(1):35-40
Objective To assess the impact of freeze-drying and dry heat virus inactivation processes on the activity ofα2-macroglobulin(A2M)derived from human plasma Cohn fraction Ⅳ.Methods A2M derived from human plasma Cohn fraction Ⅳ was prepared and subjected to programmed freeze-drying with dry heat virus inactivation.The lyophilized products were evaluated for their appearance,water content,and validation of the viral inactivation process.The bioactivity of the products before and after lyophilization as well as before and after dry heat inactivation was determined via trypsin inhibition,and the comparisons were studied.Results The appearance of the lyophilized product was fluffy,and the water content was(5.83±0.45)%.The specific activities of the samples before and after lyophilization were(10.199±0.137)and(10.033±0.201)μg/mg,respectively,with no statistically significantdifference between the two groups(P>0.05).The viral inactivation of the samples was carried out by using dry heat inactivation conditions at 100 ℃ for 30 min.After inactivation,the reduction was ≥5.125 LgTCID50/0.1 mL in Pseudorabies virus(PRV)titers,≥4.500 LgTCID50/0.1 mL in Sindbis virus(SinV)titers,≥6.375 LgTCID50/0.1 mL in encephalomyocarditis virus(EMCV)titers,and≥4.500 LgTCID50/0.1 mL in porcine parvovirus(PPV)titers.The specific activities of the samples before and after dry heat were(9.921±0.292)and(10.091±0.278)μ g/mg,respectively,with no statistically significant difference between the two groups.Conclusion A2M derived from human plasma Cohn fraction Ⅳ,when subjected to freeze-drying followed by dry heat inactivation at 100 ℃ for 30 minutes,can effectively inactivate viruses without altering the biological activity of the product.
5.The Role and Molecular Mechanism of Ginsenoside Rb1 in the Attenuation of Atherosclerosis through Suppression of Neutrophil Extracellular Trap Formation
Zhenni YANG ; Zilong ZHANG ; Jingang CUI ; Xiaoye DU ; Jing XU ; Minqi XIONG ; Yu CHEN ; Teng ZHANG
World Science and Technology-Modernization of Traditional Chinese Medicine 2025;27(10):2889-2898
Objective To investigate the role and molecular mechanism of ginsenoside Rb1(Rb1)in regulating neutrophil extracellular trapping networks(NETs)to intervene in atherosclerosis(AS).Methods In vivo:an AS model was constructed with ApoE knockout mice superimposed on a high-fat diet.The pathological and morphological changes of aortic root plaques were observed by HE staining and oil red O staining;Immunofluorescence labelling of neutrophils citrullinated histones(Cit-H3)and macrophages as well as IL-1β at the aortic root plaque site were used to assess the inflammatory infiltration.In vitro:NETs induced by PMA and cholesterol crystals were taken as models respectively.Direct effect of Rb1 against NETs formation assessed by Sytox staining and immunofluorescence staining with Cit-H3 and myeloperoxidase.Rb1 on ROS levels was assessed by DCFH-DA.Rb1 on histone H3 citrulline modification was assessed by Western blotting.Results In vivo:Rb1 significantly inhibited plaque formation,lipid deposition(P<0.05)and intra-plaque inflammatory infiltration(P<0.05).In vitro:Rb1 significantly inhibited NETs formation(P<0.05),neutrophil ROS levels(P<0.05),and Cit-H3 levels(P<0.05).Conclusions Rb1 significantly inhibited AS progression by inhibiting plaque NETs formation,which may be partly through the inhibition of histone H3 citrullination resulting from activation of the neutrophil oxidative stress pathway.
6.Diagnostic Value of Coronary Slow Flow for Coronary Microvascular Dysfunction in Patients With Angina and Nonobstructive Coronary Arteries
Zhaoxue SHENG ; Yuhui HUANG ; Xingliang LI ; Jingyu WANG ; Qiang CHEN ; Wuqiang CHE ; Zhen ZHANG ; Xuecheng ZHAO ; Shuoyan AN ; Yanxiang GAO ; Jingang ZHENG
Chinese Circulation Journal 2025;40(9):885-891
Objectives:Coronary slow flow(CSF)has long been regarded as a marker of coronary microvascular dysfunction(CMD).This study aims to evaluate the diagnostic value of CSF for CMD in patients with angina and nonobstructive coronary arteries(ANOCA).Methods:The study data were derived from the ANOCA-CMD prospective cohort study.All enrolled patients underwent coronary angiography and concurrent coronary physiological assessments in the left anterior descending artery using pressure-wire and thermodilution techniques to obtain coronary flow reserve(CFR)and the index of microcirculatory resistance(IMR).Based on the results,CMD was classified into four subtypes:CMD with elevated IMR(IMR≥25),CMD with reduced CFR(CFR<2.5),CMD with either reduced CFR or elevated IMR(CFR<2.5 or IMR≥25),and CMD with both reduced CFR and elevated IMR(CFR<2.5 and IMR≥25).The corrected thrombolysis in myocardial infarction(TIMI)frame count(CTFC)in the left anterior descending artery was calculated from coronary angiography images,with CSF defined as CTFC>27.This study evaluated the correlation between CTFC,CFR,and IMR,and investigated the diagnostic value of CSF for CMD in ANOCA patients.Results:A total of 103 ANOCA patients were enrolled in this study,with a mean age of(64.2±10.6)years,and 53.4%were female.Among them,57 patients(55.3%)were diagnosed with coronary slow flow.Patients with slow flow had higher IMR(P<0.001)and CFR(P=0.041).Similarly,the proportion of CMD with elevated IMR was higher in the slow flow group(P<0.001),while the proportion of CMD with reduced CFR was lower(P=0.044).There was no significant difference between the groups in the proportions of CMD with either reduced CFR or elevated IMR or CMD with both reduced CFR and elevated IMR(all P>0.05).CTFC was positively correlated with hyperemic mean transit time(r=0.424,P<0.001),IMR(r=0.430,P<0.001),and CFR(r=0.211,P=0.032).The area under the curve(AUC)of CTFC for diagnosing CMD with elevated IMR was 0.721(95%CI:0.623-0.819)with an accuracy of 67%(57%,76%),for diagnosing CMD with reduced CFR was 0.610(95%CI:0.499-0.720)with an accuracy of 60%(50%,70%),for diagnosing CMD with either reduced CFR or elevated IMR was 0.549(95%CI:0.425-0.673)with an accuracy of 47%(37%,57%),and for diagnosing CMD with both reduced CFR and elevated IMR was 0.582(95%CI:0.471-0.693)with an accuracy of 47%(37%,57%).Thus,CSF demonstrated limited diagnostic values across all subtypes of CMD.Conclusions:In ANOCA patients,CSF cannot serve as an effective diagnostic marker for CMD.Therefore,in clinical practice,the slow flow phenomenon should not be directly equated with the presence of coronary microvascular dysfunction in ANOCA patients.
7.The Role and Molecular Mechanism of Ginsenoside Rb1 in the Attenuation of Atherosclerosis through Suppression of Neutrophil Extracellular Trap Formation
Zhenni YANG ; Zilong ZHANG ; Jingang CUI ; Xiaoye DU ; Jing XU ; Minqi XIONG ; Yu CHEN ; Teng ZHANG
World Science and Technology-Modernization of Traditional Chinese Medicine 2025;27(10):2889-2898
Objective To investigate the role and molecular mechanism of ginsenoside Rb1(Rb1)in regulating neutrophil extracellular trapping networks(NETs)to intervene in atherosclerosis(AS).Methods In vivo:an AS model was constructed with ApoE knockout mice superimposed on a high-fat diet.The pathological and morphological changes of aortic root plaques were observed by HE staining and oil red O staining;Immunofluorescence labelling of neutrophils citrullinated histones(Cit-H3)and macrophages as well as IL-1β at the aortic root plaque site were used to assess the inflammatory infiltration.In vitro:NETs induced by PMA and cholesterol crystals were taken as models respectively.Direct effect of Rb1 against NETs formation assessed by Sytox staining and immunofluorescence staining with Cit-H3 and myeloperoxidase.Rb1 on ROS levels was assessed by DCFH-DA.Rb1 on histone H3 citrulline modification was assessed by Western blotting.Results In vivo:Rb1 significantly inhibited plaque formation,lipid deposition(P<0.05)and intra-plaque inflammatory infiltration(P<0.05).In vitro:Rb1 significantly inhibited NETs formation(P<0.05),neutrophil ROS levels(P<0.05),and Cit-H3 levels(P<0.05).Conclusions Rb1 significantly inhibited AS progression by inhibiting plaque NETs formation,which may be partly through the inhibition of histone H3 citrullination resulting from activation of the neutrophil oxidative stress pathway.
8.Diagnostic Value of Coronary Slow Flow for Coronary Microvascular Dysfunction in Patients With Angina and Nonobstructive Coronary Arteries
Zhaoxue SHENG ; Yuhui HUANG ; Xingliang LI ; Jingyu WANG ; Qiang CHEN ; Wuqiang CHE ; Zhen ZHANG ; Xuecheng ZHAO ; Shuoyan AN ; Yanxiang GAO ; Jingang ZHENG
Chinese Circulation Journal 2025;40(9):885-891
Objectives:Coronary slow flow(CSF)has long been regarded as a marker of coronary microvascular dysfunction(CMD).This study aims to evaluate the diagnostic value of CSF for CMD in patients with angina and nonobstructive coronary arteries(ANOCA).Methods:The study data were derived from the ANOCA-CMD prospective cohort study.All enrolled patients underwent coronary angiography and concurrent coronary physiological assessments in the left anterior descending artery using pressure-wire and thermodilution techniques to obtain coronary flow reserve(CFR)and the index of microcirculatory resistance(IMR).Based on the results,CMD was classified into four subtypes:CMD with elevated IMR(IMR≥25),CMD with reduced CFR(CFR<2.5),CMD with either reduced CFR or elevated IMR(CFR<2.5 or IMR≥25),and CMD with both reduced CFR and elevated IMR(CFR<2.5 and IMR≥25).The corrected thrombolysis in myocardial infarction(TIMI)frame count(CTFC)in the left anterior descending artery was calculated from coronary angiography images,with CSF defined as CTFC>27.This study evaluated the correlation between CTFC,CFR,and IMR,and investigated the diagnostic value of CSF for CMD in ANOCA patients.Results:A total of 103 ANOCA patients were enrolled in this study,with a mean age of(64.2±10.6)years,and 53.4%were female.Among them,57 patients(55.3%)were diagnosed with coronary slow flow.Patients with slow flow had higher IMR(P<0.001)and CFR(P=0.041).Similarly,the proportion of CMD with elevated IMR was higher in the slow flow group(P<0.001),while the proportion of CMD with reduced CFR was lower(P=0.044).There was no significant difference between the groups in the proportions of CMD with either reduced CFR or elevated IMR or CMD with both reduced CFR and elevated IMR(all P>0.05).CTFC was positively correlated with hyperemic mean transit time(r=0.424,P<0.001),IMR(r=0.430,P<0.001),and CFR(r=0.211,P=0.032).The area under the curve(AUC)of CTFC for diagnosing CMD with elevated IMR was 0.721(95%CI:0.623-0.819)with an accuracy of 67%(57%,76%),for diagnosing CMD with reduced CFR was 0.610(95%CI:0.499-0.720)with an accuracy of 60%(50%,70%),for diagnosing CMD with either reduced CFR or elevated IMR was 0.549(95%CI:0.425-0.673)with an accuracy of 47%(37%,57%),and for diagnosing CMD with both reduced CFR and elevated IMR was 0.582(95%CI:0.471-0.693)with an accuracy of 47%(37%,57%).Thus,CSF demonstrated limited diagnostic values across all subtypes of CMD.Conclusions:In ANOCA patients,CSF cannot serve as an effective diagnostic marker for CMD.Therefore,in clinical practice,the slow flow phenomenon should not be directly equated with the presence of coronary microvascular dysfunction in ANOCA patients.
9.Effect of measurement site on diagnostic performance of CT-derived fractional flow reserve
Yutao ZHOU ; Na ZHAO ; Yunqiang AN ; Lei SONG ; Chaowei MU ; Jingang CUI ; Tao JIANG ; Li XU ; Hongjie HU ; Lin LI ; Dumin LI ; Wenqiang CHEN ; Lijuan FAN ; Feng ZHANG ; Yang GAO ; Bin LYU
Chinese Journal of Radiology 2025;59(6):704-711
Objective:To investigate the effect of CT-derived fractional flow reserve (CT-FFR) measurement sites on the values and the diagnostic performance, and to determine the optimal measurement site for CT-FFR using invasive FFR as the reference standard.Methods:This study was part of the CT-FFR CHINA clinical trial. Patients with suspected coronary artery disease who were scheduled for invasive coronary angiography (ICA) were prospectively recruited from five clinical centers across the country from November 2018 to March 2020. Each enrolled patient underwent coronary CT angiography (CCTA), CT-FFR, ICA, and invasive pressure wire-based FFR assessments sequentially within one week. Four groups of CT-FFR values were obtained on each enrolled target vessels according to different CT-FFR measurement locations: 1, 2, 3 cm distal to the target lesion, and terminal vessel groups. Spearman and Bland-Altman analyses were used to explore the correlation and consistency of CT-FFR values and FFR values at different measurement sites. The measurement deviation of CT-FFR was also compared. Diagnostic accuracy and performance of CT-FFR, including sensitivity, specificity, positive predictive value, negative predictive value, and area under the receiver operating characteristic curve (AUC), in discriminating myocardial ischemia were analyzed across all measurement site groups on a per-vessel level, using FFR as the reference standard.Results:A total of 289 patients with 345 target lesion vessels were included. According to CCTA, there were 51 target vessels (14.8%) with<50% stenosis, 106 vessels (30.7%) with 50%-69% stenosis, and 188 vessels (54.5%) with stenosis≥70%. At per-vessel level, CT-FFR and FFR values at each measurement position group were highly positively correlated: 1 cm distal to target lesion group, r=0.734 ( P<0.001); 2 cm distal to target lesion group, r=0.732 ( P<0.001); 3 cm distal to target lesion group, r=0.737 ( P<0.001); terminal vessel group was 0.719 ( P<0.001). At per-vessel level, CT-FFR and FFR values of all measurement sites were in good agreement (Bland-Altman analysis results): 1 cm distal to target lesion group, 0.014 (95% LoA 0.002-0.026); 2 cm distal to target lesion group, 0.026 (95% LoA 0.015-0.038); 3 cm distal to target lesion group, 0.040 (95% LoA 0.039-0.051); terminal vessel group, 0.075 (95% LoA 0.064-0.087). And at per-vessel level, the accuracy of diagnosing myocardial ischemia with CT-FFR at 1 cm was highest [84.6% (95% CI 80.4%-88.3%)], and the lowest accuracy in the terminal vessel group [67.0% (95% CI 61.7%-72.0%)]. However, there was no significant difference in the diagnostic accuracy of CT-FFR at 1 cm, 2 cm [80.6% (95% CI 76.1%-84.6%)] and 3 cm [77.5% (95% CI 72.6%-81.7%)]. AUC of CT-FFR at 1 cm distal to the lesion were both highest for global level and moderately stenosis (50%-69%) lesions [0.85 (95% CI 0.81-0.89), 0.84 (95% CI 0.77-0.90)]. And the differences were statistically significant among the four measurement location groups (all P<0.05). Conclusions:The deviation of CT-FFR increases with measurement site distance distal to target lesions. One centimeter distal to the target lesion is the optimal measurement site, and the CT-FFR value here shows the highest diagnostic performance for myocardial ischemic lesions, especially for moderate stenosis.
10.Construction of a nomogram model for recurrence of persistent AF after radiofrequency ablation based on imaging and serological features
Qiangqiang PAN ; Jiazhong LU ; Xincai LÜ ; Hui RAN ; Biao ZHANG ; Chengzhen RONG ; Jingang ZHANG ; Hongju WANG
Chinese Journal of Geriatric Heart Brain and Vessel Diseases 2024;26(8):876-881
Objective To investigate the risk factors for recurrence of persistent atrial fibrillation(AF)after radiofrequency ablation with circumferential pulmonary vein isolation+top line+back wall line based on the features of cardiac imaging and serum biomarkers,and then to establish a nomogram risk prediction model.Methods A total of 172 patients with persistent AF admitted to our hospital from June 2022 to September 2023 were enrolled and then according to recurrence or not in 6 months after surgery,they were divided into the recurrence group(51 cases)and the non-ecurrence group(121 cases).Before surgery,routine electrocardiography,and transthoracic and esophageal echocardiography were performed,while blood routine indicators and related biochemi-cal indicators were measured.All patients underwent radiofrequency ablation with circumferential pulmonary vein isolation,top line,and back wall line.They were followed up for 6 months after surgery.Binary logistic analysis was used to analyze the independent risk factors for postoperative recurrence,and then a nomogram risk prediction model was constructed and its diagnostic per-formance was evaluated.Results Lager LAD,higher LAVI,neutrophil count and NLR,and ele-vated BNP and CRP levels,while lower LAAFV,LAAEV and LAAEF were observed in the re-current group than those in the non-recurrent group(P<0.01).Binary logistic regression analysis showed that elevated LAVI(OR=1.160,95%CI:1.006-1.337),decreased LAAEV(OR=0.740,95%CI:0.583-0.940),decreased LAAEF(OR=0.608,95%CI:0.422-0.877),elevated BNP(OR=1.017,95%CI:1.004-1.030),and higher NLR(OR=10.116,95%CI:1.316-77.755)were independent risk factors for recurrence after radiofrequency ablation of pulmonary vein isolation+top line+posterior wall line in persistent AF patients(P<0.05,P<0.01).The AUC value of the nomogram model constructed with LAVI,LAAEV,LAAEF,BNP and NLR in predicting postop-erative recurrence was 0.889(95%CI:0.833-0.932).Conclusion The cardiac imaging parame-ters LAVI,LAAEV and LAAEF,and serum biomarkers BNP and NLR are closely associated with postoperative recurrence of persistent AF in patients after radiofrequency ablation with cir-cumferential pulmonary vein isolation+top line+back wall line,and the relevant nomogram mod-el has better diagnostic value for postoperative recurrence.

Result Analysis
Print
Save
E-mail