1.Regulatory Pathways of Cell Apoptosis in Diabetic Kidney Disease and Intervention by Traditional Chinese Medicine: A Review
Yunjie YANG ; Mingqian JIANG ; Chen QIU ; Yaqing RUAN ; Senlin CHEN ; Wenxin HUANG ; Hangbin ZHENG ; Yi WEI ; Pengfei LI ; Xueqin LIN ; Jing WU ; Shiwei RUAN ; Jianting WANG ; Yuliang QIU
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(9):294-306
Diabetic kidney disease(DKD) is a chronic kidney structural and functional disorder caused by diabetes. With the global prevalence of diabetes continuing to rise, DKD has gradually become a major cause of chronic kidney disease and end-stage renal disease(ESRD), posing a serious threat to patients' quality of life and long-term health outcomes. Studies have shown that apoptosis plays a pivotal role in the development and progression of DKD, with its mechanisms involving abnormal activation of multiple signaling pathways such as Toll-like receptor 4(TLR4)/nuclear transcription factor-κB(NF-κB)/B-cell lymphoma-2(Bcl-2)/cysteinyl aspartate-specific proteinase(Caspase)-3, protein kinase R-like endoplasmic reticulum kinase(PERK)/eukaryotic initiation factor 2α(eIF2α)/activating transcript factor 4(ATF4)/CCAAT enhancer-binding protein homologous protein(CHOP), phosphatidylinositol 3-kinase(PI3K)/protein kinase B(Akt)/glycogen synthase kinase-3β(GSK-3β), Janus kinase 2(JAK2)/signal transducer and activator of transcription 3(STAT3), adenosine monophosphate-activated protein kinase(AMPK)/mammalian target of rapamycin(mTOR) and silent information regulator 1(SIRT1)/tumor suppressor protein 53(p53), thereby accelerating renal pathological damage in DKD. Extensive evidence-based medical studies have confirmed that traditional Chinese medicine(TCM), leveraging its unique therapeutic advantages of multi-target, multi-component and multi-pathway approaches, has demonstrated remarkable efficacy and favorable safety profiles in treating DKD. Recent studies have demonstrated that active components of TCM can specifically target and modulate key effectors in apoptotic signaling pathways. Meanwhile, traditional compound formulations exert synergistic effects through multiple approaches such as replenishing deficiency and activating blood circulation, detoxifying and dredging collaterals, tonifying kidney essence, and removing stasis and purging turbidity, thereby comprehensively regulating critical pathological processes including endoplasmic reticulum stress and mitochondrial apoptosis pathways. This combined therapeutic approach of molecular targeting and holistic regulation provides novel strategies for delaying the progression of DKD. Based on this, this paper provides an in-depth analysis of key apoptotic signaling pathways and their regulatory mechanisms, while systematically summarizing recent research advances regarding the therapeutic effects of TCM active components, compound formulations, and proprietary Chinese medicines on DKD through modulation of these pathways, with particular emphasis on their underlying molecular mechanisms. These findings not only elucidate the modern scientific connotation and theoretical basis of TCM in treating DKD but also establish a solid theoretical and practical foundation for promoting the wider clinical application and further research of TCM in the field of DKD treatment.
2.Construction of Organoid-on-a-chip and Its Applications in Biomedical Fields
Rui-Xia LIU ; Jing ZHANG ; Xiao LI ; Yi LIU ; Long HUANG ; Hong-Wei HOU
Progress in Biochemistry and Biophysics 2026;53(2):293-308
Organoid-on-a-chip technology represents a promising interdisciplinary advancement that merges two cutting-edge biomedical platforms: stem cell-derived organoids and microfluidics-based organ-on-a-chip systems. Organoids are self-organizing three-dimensional (3D) cell cultures that mimic the key structural and functional features of in vivo organs. However, traditional organoid culture systems are often static, lacking dynamic environmental cues and suffering from limitations such as batch-to-batch variability, low stability, and low throughput. Organ-on-a-chip platforms, by contrast, utilize microfluidic technologies to simulate the dynamic physiological microenvironment of human tissues and organs, enabling more controlled cell growth and differentiation. By integrating the advantages of organoids and organ-on-a-chip technologies, organoid-on-a-chip systems transcend the limitations of conventional 3D culture models, offering a more physiologically relevant and controllable in vitro platform. In organoid-on-a-chip systems, stem cells or pre-formed organoids are cultured in micro-engineered environments that mimic in vivo conditions, enabling precise control over fluid flow, mechanical forces, and biochemical cues. Specifically, these platforms employ advanced strategies including bio-inspired 3D scaffolds for structural support, precise spatial cell patterning via 3D bioprinting, and integrated biosensors for real-time monitoring of metabolic activities. These synergistic elements recreate complex extracellular matrix signals and ensure high structural fidelity. Based on structural complexity, organoid-on-a-chip systems are classified into single-organoid and multi-organoid types, forming a trajectory from unit biomimicry to systemic simulation. Single-organoid chips focus on highly biomimetic units by integrating vascular, immune, or neural functions. Multi-organoid chips simulate inter-organ crosstalk and systemic homeostasis, advancing complex disease modeling and PK/PD evaluation. This emerging technology has demonstrated broad application potential in multiple fields of biomedicine. Organoid-on-a-chip systems can recapitulate organ developmentin vitro, facilitating research in developmental biology. They mimic organ-specific physiological activities and mechanisms, showing promising applications in regenerative medicine for tissue repair or replacement. In disease modeling, they support the reconstruction of models for neurodegenerative, inflammatory, infectious, metabolic diseases, and cancers. These platforms also enable in vitro drug testing and pharmacokinetic studies (ADME). Patient-derived chips preserve genetic and pathological features, offering potential for precision medicine. Additionally, they reduce species differences in toxicology, providing human-relevant data for environmental, food, cosmetic, and drug safety assessments. Despite progress, organoid-on-a-chip systems face challenges in dynamic simulation, extracellular matrix (ECM) variability, and limited real-time 3D imaging, requiring improved materials and the integration of developmental signals. Current bottlenecks also include the high technical threshold for automation and the lack of standardized validation frameworks for regulatory adoption. Meanwhile, the concept of a “human-on-a-chip” has been proposed to mimic whole-body physiology by integrating multiple organoid modules. This approach enables systemic modeling of drug responses and toxicity, with the potential to reduce animal testing and revolutionize drug development. Future advancements in bio-responsive hydrogels and flexible biosensors will further empower these platforms to bridge the gap between bench-side research and personalized clinical interventions. In conclusion, organoid-on-a-chip technology offers a transformative in vitro model that closely recapitulates the complexity of human tissues and organ systems. It provides an unprecedented platform for advancing biomedical research, clinical translation, and pharmaceutical innovation. Continued development in biomaterials, microengineering, and analytical technologies will be essential to unlocking the full potential of this powerful tool.
3.Construction of Organoid-on-a-chip and Its Applications in Biomedical Fields
Rui-Xia LIU ; Jing ZHANG ; Xiao LI ; Yi LIU ; Long HUANG ; Hong-Wei HOU
Progress in Biochemistry and Biophysics 2026;53(2):293-308
Organoid-on-a-chip technology represents a promising interdisciplinary advancement that merges two cutting-edge biomedical platforms: stem cell-derived organoids and microfluidics-based organ-on-a-chip systems. Organoids are self-organizing three-dimensional (3D) cell cultures that mimic the key structural and functional features of in vivo organs. However, traditional organoid culture systems are often static, lacking dynamic environmental cues and suffering from limitations such as batch-to-batch variability, low stability, and low throughput. Organ-on-a-chip platforms, by contrast, utilize microfluidic technologies to simulate the dynamic physiological microenvironment of human tissues and organs, enabling more controlled cell growth and differentiation. By integrating the advantages of organoids and organ-on-a-chip technologies, organoid-on-a-chip systems transcend the limitations of conventional 3D culture models, offering a more physiologically relevant and controllable in vitro platform. In organoid-on-a-chip systems, stem cells or pre-formed organoids are cultured in micro-engineered environments that mimic in vivo conditions, enabling precise control over fluid flow, mechanical forces, and biochemical cues. Specifically, these platforms employ advanced strategies including bio-inspired 3D scaffolds for structural support, precise spatial cell patterning via 3D bioprinting, and integrated biosensors for real-time monitoring of metabolic activities. These synergistic elements recreate complex extracellular matrix signals and ensure high structural fidelity. Based on structural complexity, organoid-on-a-chip systems are classified into single-organoid and multi-organoid types, forming a trajectory from unit biomimicry to systemic simulation. Single-organoid chips focus on highly biomimetic units by integrating vascular, immune, or neural functions. Multi-organoid chips simulate inter-organ crosstalk and systemic homeostasis, advancing complex disease modeling and PK/PD evaluation. This emerging technology has demonstrated broad application potential in multiple fields of biomedicine. Organoid-on-a-chip systems can recapitulate organ developmentin vitro, facilitating research in developmental biology. They mimic organ-specific physiological activities and mechanisms, showing promising applications in regenerative medicine for tissue repair or replacement. In disease modeling, they support the reconstruction of models for neurodegenerative, inflammatory, infectious, metabolic diseases, and cancers. These platforms also enable in vitro drug testing and pharmacokinetic studies (ADME). Patient-derived chips preserve genetic and pathological features, offering potential for precision medicine. Additionally, they reduce species differences in toxicology, providing human-relevant data for environmental, food, cosmetic, and drug safety assessments. Despite progress, organoid-on-a-chip systems face challenges in dynamic simulation, extracellular matrix (ECM) variability, and limited real-time 3D imaging, requiring improved materials and the integration of developmental signals. Current bottlenecks also include the high technical threshold for automation and the lack of standardized validation frameworks for regulatory adoption. Meanwhile, the concept of a “human-on-a-chip” has been proposed to mimic whole-body physiology by integrating multiple organoid modules. This approach enables systemic modeling of drug responses and toxicity, with the potential to reduce animal testing and revolutionize drug development. Future advancements in bio-responsive hydrogels and flexible biosensors will further empower these platforms to bridge the gap between bench-side research and personalized clinical interventions. In conclusion, organoid-on-a-chip technology offers a transformative in vitro model that closely recapitulates the complexity of human tissues and organ systems. It provides an unprecedented platform for advancing biomedical research, clinical translation, and pharmaceutical innovation. Continued development in biomaterials, microengineering, and analytical technologies will be essential to unlocking the full potential of this powerful tool.
4.Rapid Identification of Different Parts of Nardostachys jatamansi Based on HS-SPME-GC-MS and Ultra-fast Gas Phase Electronic Nose
Tao WANG ; Xiaoqin ZHAO ; Yang WEN ; Momeimei QU ; Min LI ; Jing WEI ; Xiaoming BAO ; Ying LI ; Yuan LIU ; Xiao LUO ; Wenbing LI
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(2):182-191
ObjectiveTo establish a model that can quickly identify the aroma components in different parts of Nardostachys jatamansi, so as to provide a quality control basis for the market circulation and clinical use of N. jatamansi. MethodsHeadspace solid-phase microextraction-gas chromatography-mass spectrometry(HS-SPME-GC-MS) combined with Smart aroma database and National Institute of Standards and Technology(NIST) database were used to characterize the aroma components in different parts of N. jatamansi, and the aroma components were quantified according to relative response factor(RRF) and three internal standards, and the markers of aroma differences in different parts of N. jatamansi were identified by orthogonal partial least squares-discriminant analysis(OPLS-DA) and cluster thermal analysis based on variable importance in the projection(VIP) value >1 and P<0.01. The odor data of different parts of N. jatamansi were collected by Heracles Ⅱ Neo ultra-fast gas phase electronic nose, and the correlation between compound types of aroma components collected by the ultra-fast gas phase electronic nose and the detection results of HS-SPME-GC-MS was investigated by drawing odor fingerprints and odor response radargrams. Chromatographic peak information with distinguishing ability≥0.700 and peak area≥200 was selected as sensor data, and the rapid identification model of different parts of N. jatamansi was established by principal component analysis(PCA), discriminant factor alysis(DFA), soft independent modeling of class analogies(SIMCA) and statistical quality control analysis(SQCA). ResultsThe HS-SPME-GC-MS results showed that there were 28 common components in the underground and aboveground parts of N. jatamansi, of which 22 could be quantified and 12 significantly different components were screened out. Among these 12 components, the contents of five components(ethyl isovalerate, 2-pentylfuran, benzyl alcohol, nonanal and glacial acetic acid,) in the aboveground part of N. jatamansi were significantly higher than those in the underground part(P<0.01), the contents of β-ionone, patchouli alcohol, α-caryophyllene, linalyl butyrate, valencene, 1,8-cineole and p-cymene in the underground part of N. jatamansi were significantly higher than those in the aboveground part(P<0.01). Heracles Ⅱ Neo electronic nose results showed that the PCA discrimination index of the underground and aboveground parts of N. jatamansi was 82, and the contribution rates of the principal component factors were 99.94% and 99.89% when 2 and 3 principal components were extracted, respectively. The contribution rate of the discriminant factor 1 of the DFA model constructed on the basis of PCA was 100%, the validation score of the SIMCA model for discrimination of the two parts was 99, and SQCA could clearly distinguish different parts of N. jatamansi. ConclusionHS-SPME-GC-MS can clarify the differential markers of underground and aboveground parts of N. jatamansi. The four analytical models provided by Heracles Ⅱ Neo electronic nose(PCA, DFA, SIMCA and SQCA) can realize the rapid identification of different parts of N. jatamansi. Combining the two results, it is speculated that terpenes and carboxylic acids may be the main factors contributing to the difference in aroma between the underground and aboveground parts of N. jatamansi.
5.Construction and Application Promotion of Core Medical Skills of"Tonifying Kidney Essence"in Zou's Nephrology Depart-ment
Gang WANG ; Yanqin ZOU ; Wei SUN ; Enchao ZHOU ; Lan YI ; Jun ZHU ; Wei KONG ; Jing ZHAO ; Liang CAO ; Hengbin WANG
Journal of Nanjing University of Traditional Chinese Medicine 2025;41(3):281-287
Professor Zou Yunxiang proposed the"kidney essence theory"in 1955,which believes that the kidney,as an important excretory organ in the human body,participates in the body's metabolism,and the basis for producing this effect is the essence of the kidney.Subsequently,the Zou nephrology team established the core medical technique of"tonifying the kidney element"based on this foundation,constructed a system of syndrome differentiation and treatment for chronic kidney disease,proposed the traditional Chinese medicine names,causes,and mechanisms of chronic kidney disease,as well as four major methods for diagnosing and treating chronic kidney disease,and developed representative drugs representing the core medical technique of"tonifying the kidney element"-Huang-zhi Yishen Capsules and Shenwu Yishen Tablets.In addition,the Zou nephrology team has extensively applied and promoted the core medical technique of"tonifying the kidney element".
6.Knockdown of GPER1 aggravates neuronal injury and cognitive dysfunction after epilepsy
Shi-jie HAO ; Yi-jin LUO ; Xiao-fan REN ; Na DING ; Jing-bo CAO ; Qian ZHAO ; Wei HE ; Shao-zhang HOU ; Di ZUO
Chinese Pharmacological Bulletin 2025;41(7):1332-1339
Aim To investigate the impact of G pro-tein-coupled estrogen receptor 1(GPER1),also known as GPR30 playing a significant role in the nerv-ous system,on neuronal damage and cognitive dysfunc-tion following epileptic seizures.Methods The pro-tein expression levels of GPER1 and the DNA damage marker γ-H2AX in epileptic rats were assessed using Western blot.The hippocampal neuronal damage and apoptosis in pilocarpine-induced epilepsy models were evaluated using Nissl and TUNEL staining techniques,compared with GPER1 knockdown(GPER1-KD)rats with wild-type(WT)controls.The behavioral activi-ties,including memory and spatial learning,were mo-nitored during the chronic phase of epilepsy using the IntelliCage system.Results Compared to the control group,GPER1 protein expression in the cerebral cortex and hippocampus significantly increased 24 hours post-epilepsy onset.In the GPER1-KD+EP group,hipp-ocampal neuronal damage was more severe,with a sig-nificant increase in apoptotic neurons compared to the WT+EP group.The IntelliCage data revealed that during free exploration,nose contact,position learn-ing,and reverse position learning stages in the GPER1-KD+EP group exhibited fewer visits and a higher error rate than in the WT+EP group.Conclu-sions Deficiency in GPER1 impairs memory and spa-tial learning abilities following epilepsy,potentially due to exacerbated neuronal injury,apoptosis,and inflam-mation.GPER1 represents a promising therapeutic tar-get for mitigating post-epileptic nerve damage and cog-nitive impairment.
7.Clinical characteristics and prognosis of perioperative myocardial injury after non-cardiac surgery in intensive care unit patients
Shi-hong XIA ; Xue-li MA ; Guo-feng SHEN ; Li-jing JIANG ; Kang-yi LIU ; Wei-yi TANG ; Jin-di NI ; Xiang LI
Fudan University Journal of Medical Sciences 2025;52(3):424-428,445
Objective To retrospectively analyze the clinical risk factors and prognosis of perioperative myocardial injury(MINS)in non-cardiac surgery patients admitted to the intensive care unit(ICU).Methods A total of 478 postoperative patients admitted to the Department of Intensive Medicine,Minhang Hospital,Fudan University from Jan 2020 to Dec 2023 were selected.They were divided into MINS group(n=302)and normal group(n=176)based on whether myocardial injury occurred within 7 days after surgery.The differences in clinical characteristics between the two groups were compared,and risk factors for perioperative myocardial injury were identified.Risk factors for mortality in the MINS group were analyzed with 30-day mortality as the clinical endpoint.Results The prevalence of acute physiology and chronic health evaluation Ⅱ(Apache Ⅱ)score,coronary artery disease,and chronic kidney disease were all higher in the MINS group than those in the normal group,with statistically significant differences(P<0.05).The proportion of emergency surgeries,co-infection,and perioperative hypotension were significantly different between the MINS group and the normal group(P<0.05).Multivariate logistic regression analysis revealed that chronic kidney disease,emergency surgery,co-infection,and intraoperative and postoperative hypotension were risk factors for MINS occurrence.Prognostic analysis indicated that perioperative hypotension was a risk factor for 30-day mortality in MINS patients.Conclusion MINS is closely associated with patients'underlying conditions,timing of surgery,and perioperative hypotension status,and especially perioperative hypotension affects the final outcomes.
8.Preliminary clinical exploration of endoscopic ultrasound combined with modified endoscopic mucosal resection in the treatment of rectal neuroendocrine tumors
Ping LUO ; Aimin LIU ; Zhiqiang YI ; Qiaomu LUO ; Sha WEI ; Jing KUANG ; Jing TANG
Chongqing Medicine 2025;54(4):893-897
Objective To investigate the clinical feasibility and safety of endoscopic ultrasonography(EUS)combined with modified endoscopic mucosal resection(EMR)in the treatment of rectal neuroendo-crine tumors(RNETs).Methods A total of 48 patients diagnosed with RNETs by colonoscopy in the depart-ment of gastroenterology in this hospital from December 2021 to June 2023 were selected as the study objects.Patients were randomly divided into the study group(EUS combined with modified EMR,n=16),the control 1 group(traditional EMR,n=16)and the control 2 group[endoscopic submucosal dissection(ESD),n=16].The operation time,R0 resection rate and postoperative complications of each group were observed.Endoscop-ic ultrasonography was followed up 3 and 6 months after surgery to determine whether there was any recur-rence.Results The operative time of the study group[(17.813±0.379)min]was significantly shorter than that of the control 2 group[(36.250±3.296)min],the difference was statistically significant(P<0.05),but compared with the control 1 group[(16.375±1.996)min],there was no significant difference(P>0.05).The incidence of complications in the study group(6.2%)was significantly lower than that in the control 2 group(37.5%),the difference was statistically significant(P<0.05).while the incidence of complications in the study group was not significantly higher than that in the control 1 group(12.5%,P>0.05).R0 removal rate in the study group(93.8%)was significantly higher than that in the control 1 group(62.5%)and the control 2 group(75.0%),the difference was statistically significant(P<0.05).Conclusion EUS combined with modified EMR has more advantages than EMR and ESD in the treatment of RNETs,and has certain fea-sibility and safety,which is convenient for clinical application.
9.Development of A High-performance Rectangular Ion Trap for Multi-reflection Time-of-Flight Mass Spectrometer
Xiao-Xia CHEN ; Yi REN ; Qi HUANG ; Da-Jun XIANG ; Chang-Wei LI ; Yi HONG ; Lei LI ; Zheng-Xu HUANG ; Mei LI ; Jing-Wei XU ; Zhen ZHOU
Chinese Journal of Analytical Chemistry 2025;53(1):38-46
As a new generation of time-of-flight mass spectrometry,multiple-reflection time-of-flight mass spectrometry(MR-TOF-MS)has been increasingly applied in the fields such as nuclear physics,chemistry,and biology due to its ultra-high resolution and rapid analysis capabilities.However,the analytical performance of MR-TOF-MS largely depends on the ion bunch state entering the mass analyzer.In this study,a rectangular ion trap(RIT)was developed,designed and processed using printed circuit board technology,as an ion accumulating and focusing device for MR-TOF mass analyzer.Compared to traditional ion traps composed of two sets of planar electrodes,this RIT had higher voltage utilization efficiency,resulting in more efficient ion collection and focusing.The ions were cooled to a sufficiently small bunch for precise mass measurement with MR-TOF-MS mass spectrometry in only 1 ms of cooling time in the RIT,then orthogonally ejected to the MR-TOF mass spectrometer for mass analysis.Experimental results indicated that the working cycle,ion flux,and ion focusing state of the RIT fully met the requirements of the MR-TOF mass analyzer.When coupled with the MR-TOF mass analyzer,the RIT enabled MR-TOF-MS to achieve a mass resolution of 1.5×105.
10.Determination of 71 Kinds of Per-and Polyfluoroalkyl Substances in Eckloniae Thallus by QuEChERS-Liquid Chromatography-Tandem Mass Spectrometry
Dan-Rui TANG ; Jing SUN ; Ling CAO ; Dan-Yi JIANG ; Hai-Wei SHI ; Lu-Lu WU
Chinese Journal of Analytical Chemistry 2025;53(7):1177-1185,中插9-中插25
A QuEChERS cleanup-ultra performance liquid chromatography-tandem mass spectrometry(UPLC-MS/MS)method was established for simultaneous determination of traditional and emerging 71 kinds of per-and polyfluoroalkyl substances(PFAS)in Chinese herbal medicine Eckloniae Thallus.The extraction solvent employed here was 0.2%formic acid-acetonitrile with sodium chloride-anhydrous sodium sulfate(3:1,m/m)as salting-out agent,and the purification was carried out using graphitized carbon black and octadecyl-bonded silica as adsorbents.The sample separation was carried out on a Horizon C18 chromatographic column(150 mm×2.1 mm,1.6 μm)by gradient elution with 2.5 mmol/L ammonium acetate aqueous solution(containing 2.5 mmol/L acetic acid)and acetonitrile as the mobile phases.The flow rate was set at 0.4 mL/min,with an injection volume of 5 μL.The chromatographic separation of each target compound and internal standard substance could be achieved within 15 min.An electrospray ion source was utilized for simultaneous scanning of positive and negative ions under the scheduled multiple reaction monitoring(sMRM)mode,and the internal standard method was used for quantitative analysis.The results of method validations showed that the 71 kinds of PFAS had good linearity,with a correlation coefficient(r)greater than 0.997,spiked recoveries of 76.2%?122.0%and relative standard deviations(RSDs)of 5.5%?14.8%.The limits of detection were in the range of 0.3-60 ng/kg and the limits of quantification were in the range of 0.8-199 ng/kg.The developed method was used for detection of PFAS in 14 batches of Eckloniae Thallus samples,and a total of 19 kinds of PFAS were detected.The findings indicated that PFAS residues were commonly present in Eckloniae Thallus,with perfluorocarboxylic acids(PFCAs)exhibiting the highest concentrations.The method was simple,robust and efficient in preparation,sensitive in detection with high throughput,and suitable for monitoring residual PFAS compounds,including both ionic and neutral in food-medicine homology samples such as Eckloniae Thallus.

Result Analysis
Print
Save
E-mail