1.Characterization and Application of Moisture Absorption Kinetics of Traditional Chinese Medicines Based on Double Exponential Model:A Review
Yanting YU ; Lei XIONG ; Yan HE ; Wei LIU ; Jing YANG ; Yao ZHANG ; Jiali CHEN ; Xiaojian LUO ; Xiaoyong RAO
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(5):340-346
Hygroscopicity research has long been a key focus and hot topic in Chinese materia medica(CMM). Elucidating hygroscopic mechanisms plays a vital role in formulation design, process optimization, and storage condition selection. Hygroscopic models serve as essential tools for characterizing CMM hygroscopic mechanisms, with various types available. The double exponential model is a kinetic mathematical model constructed based on the law of conservation of energy and Fick's first law of diffusion, tailored to the physical properties of CMM extracts. In recent years, this model has been extensively applied to simulate the dynamic moisture absorption behavior of CMM extracts and solid dosage forms under varying humidity conditions. It has revealed the correlation between moisture absorption kinetic parameters and material properties, offering a new perspective for characterizing the moisture uptake behavior of CMM. This paper systematically reviews the application progress of this model in the field of CMM, analyzes its advantages, disadvantages, and challenges in this domain, and explores its potential application trends in other fields. It aims to provide references for elucidating the moisture absorption mechanisms of CMM and researching moisture-proofing technologies, while also offering insights for its broader application in food and polymer materials.
2.Qualitative and Quantitative Analysis of Chemical Constituents in Gualou Niubangtang by UPLC-Q-TOF-MS/MS and HPLC
Yiyi ZHANG ; Jing YANG ; Yuqing CHENG ; Huimin GAO ; Jin QIN ; Li YAO ; Xiyang DU ; Raorao LI
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(6):179-187
ObjectiveThis paper aims to clarify the material basis of Gualou Niubangtang and establish a quantitative analysis method for its main constituents, providing a reference for the overall quality control of this preparation. MethodsThe constituents in the formula were systematically characterized based on ultra-performance liquid chromatography-quadrupole time-of-flight tandem mass spectrometry (UPLC-Q-TOF-MS/MS). Identification was performed by matching with the UNIFI 9.6 software and utilizing database platforms such as PubChem, ChemicalBook, and ChemSpider, combined with relevant literature reports. A quantitative analysis method for the seven main constituents in Gualou Niubangtang was established by using high performance liquid chromatography (HPLC). ResultsUPLC-Q-TOF-MS/MS analysis identified 155 constituents, including 69 flavonoids, 36 terpenoids, 23 phenylpropanoids, 8 phenylethanoid glycosides, and 19 other types of constituents. In the established quantitative analysis method, the seven main constituents showed good linearity within their respective linear ranges. The precision, repeatability, stability, and spike recovery all met the required standards. The results showed that the content ranges of geniposide, liquiritin, hesperidin, arctiin, baicalin, oroxylin A-7-O-β-D-glucuronide, and wogonoside in 15 batches of Gualou Niubangtang were 13.67-21.25, 1.20-7.64, 5.45-7.45, 22.97-33.51, 29.95-39.07, 2.58-4.80, and 6.56-9.31 mg·g-1, respectively. ConclusionThis study successfully characterizes and attributes multi-category constituents in Gualou Niubangtang, clarifying that its material basis is primarily composed of flavonoids, terpenoids, phenylethanoid glycosides, and phenylpropanoids. Furthermore, it enables the quantification of seven constituents within the formula. This work lays a foundation for research on the quality control, action mechanism, and clinical application of this formula.
3.Functional validation of a rare SOS1 gene variant and literature review.
Xiaosha JING ; Yao LIU ; Yanting YANG ; Hongqian LIU
Chinese Journal of Medical Genetics 2026;43(3):197-203
OBJECTIVE:
To analyze the functional impact of a rare heterozygous variant of SOS1 gene (c.283G>A, p.E95K) identified in a fetus with cervical cystic hygroma and to explore its association with the disease phenotype.
METHODS:
A pedigree analysis was carried out to evaluate the co-segregation of the variant with the disease phenotype. Bioinformatic tools were employed to assess the conservation, protein structure and stability. Functional validation was conducted on HEK293T cells using fluorescence quantitative reverse transcription-PCR and Western blotting to measure the expression of SOS1 and phosphorylation levels of extracellular regulated protein kinases (ERK) and c-Jun N-terminal kinase. A literature review of previously reported disease-associated SOS1 variants was also carried out. This study has been approved by the Medical Ethics Committee of West China Second University Hospital, Sichuan University (Ethics No.: 201940).
RESULTS:
The variant was inherited from the husband of the woman with distinctive facial features and has co-segregated with the phenotype. Bioinformatics analysis indicated that the variant is located in a highly conserved region, and that p.E95K could disrupt key amino acid interactions and protein stability. Multiple bioinformatic predictions consistently suggested the pathogenicity of this variant. Functional assays demonstrated reduced SOS1 protein expression and decreased ERK phosphorylation.
CONCLUSION
This study has revealed the functional impact of the SOS1 c.283G>A (p.E95K) variant, suggesting that it may contribute to the developmental phenotypes through a haploinsufficiency mechanism.
Humans
;
SOS1 Protein/chemistry*
;
Female
;
HEK293 Cells
;
Male
;
Pedigree
;
Phenotype
;
Adult
4.VEGF Inhibitor–Associated Side Effects in Antitumor Therapy and Intervention Strategies
Lu LIU ; Wanting SUN ; Shuning YAO ; Zhenyu CHEN ; Yuefei WANG ; Jing YANG
Cancer Research on Prevention and Treatment 2026;53(4):289-300
Vascular endothelial growth factor (VEGF) inhibitors are drugs that target and inhibit tumor angiogenesis. By blocking the signaling pathway of VEGF and its receptor, they suppress tumor proliferation and play a crucial role in tumor treatment. However, their side effects, such as hypertension, proteinuria, hand-foot skin reactions, and myelosuppression, during treatment seriously affect patients' treatment compliance and quality of life. The development of intervention strategies for the side effects of VEGF inhibitors is of great importance for tumor treatment. This article reviews the clinical characteristics and toxic mechanisms of common side effects caused by VEGF inhibitors during tumor treatment and summarizes intervention strategies that combine traditional Chinese and Western medicines. Drug dosages were precisely monitored and adjusted to achieve antitumor treatment. Patients' discomfort symptoms are improved through prescriptions that act by tonifying qi and promoting blood circulation, strengthening the spleen, and tonifying the kidney. The combination of traditional Chinese and Western medicines is used to treat patients, thus providing a safe and effective treatment plan for patients with cancer.
5.MRI findings of spinal cord atrophy after spinal cord injury in children and their injury level
Yingxin ZHANG ; Genlin LIU ; Di CHEN ; Hongxia ZHANG ; Yifan TIAN ; Yiji WANG ; Yang JING ; Ruidong CHENG ; Shaomin ZHANG ; Jiafeng YAO ; Bo SUN ; Xiaomeng SUN
Chinese Journal of Rehabilitation Theory and Practice 2026;32(4):387-392
ObjectiveTo delineate imaging findings using an imaging platform and investigate the correlation between MRI characteristics of spinal cord atrophy and clinical diagnosis in children with spinal cord injury (SCI). MethodsImaging data of 150 children with SCI admitted to Beijing Bo'ai Hospital, China Rehabilitation Research Center, from January, 2002 to March, 2024 were collected and imported into the imaging platform. The anteroposterior and transverse diameters of the middle part of the spinal cord at the cross-section with the most severe atrophy were measured, and the relevant indicators of the previous normal spinal cord segment were measured as controls; the radiomic features were extracted. Clinical data of the children including gender, age, cause of injury, sensory level, motor level, spinal cord injury level, injury severity and disease course were collected. ResultsSpinal cord atrophy was identified in 81 cases (54%), among which 78 cases (96%) were American Spinal Injury Association Impairment Scale (AIS) grade A and 3 cases (4%) were AIS grade C. The upper boundary of the spinal cord atrophy site strongly correlated with the injury level, motor level and sensory level (r > 0.8, P < 0.001). ConclusionMore than half of children with SCI may develop secondary spinal cord atrophy, the vast majority of whom suffer from complete spinal cord injury; the upper boundary of spinal cord atrophy is correlated with the injury level.
6.Spatiotemporal Electrical Impedance Tomography for Speech Respiratory Assessment in Cleft Palate: an Interpretable Machine Learning Study
Yang WU ; Xiao-Jing ZHANG ; Hao YU ; Cheng-Hui JIANG ; Bo SUN ; Jia-Feng YAO
Progress in Biochemistry and Biophysics 2026;53(2):485-500
ObjectiveCleft palate (CP) is a common congenital deformity often associated with velopharyngeal insufficiency (VPI), which disrupts the physiological coupling between respiration and speech. Conventional clinical assessments, such as nasometry and spirometry, provide limited static data and fail to visualize the dynamic spatiotemporal distribution of lung ventilation during phonation. This study introduces spatiotemporal electrical impedance tomography (ST-EIT) to evaluate speech-respiratory functional features in CP patients compared to normal controls (NC). The aim is to characterize multi-domain respiratory patterns and to validate an interpretable machine learning framework for providing objective, quantitative evidence for clinical assessment. MethodsSeventy-five participants were enrolled in this study, comprising 37 patients with surgically repaired CP and 38 healthy volunteers matched for age, gender, and body mass index (BMI). All subjects performed standardized sustained phonation tasks while undergoing synchronous monitoring with a 16-electrode EIT system and a pneumotachograph. A comprehensive feature engineering pipeline was developed to extract physiological parameters across 3 complementary domains. (1) Temporal domain: including inspiratory/expiratory phase duration (tPhase), time constants (Tau), and inspiratory-to-expiratory time ratios (TI/TE); (2) airflow domain: comprising mean flow, peak flow, and instantaneous flow at 25%, 50%, and 75% of tidal volume; and (3) spatial domain: quantifying global and regional tidal impedance variation (TIV), global inhomogeneity (GI), and center of ventilation (CoV). Extreme Gradient Boosting (XGBoost) classifiers were trained using 5 distinct data sources (Spirometry, Nasometry, Inspiratory-EIT, Expiratory-EIT, and fused ST-EIT). Model performance was rigorously evaluated via stratified 5-fold cross-validation, and Shapley additive explanations (SHAP) were employed to quantify global and local feature contributions. ResultsThe CP group exhibited a distinct respiratory phenotype compared to controls. In the temporal domain, CP patients showed significantly shorter inspiratory (1.60 s vs.1.85 s, P<0.001) and expiratory phase durations (2.45 s vs. 3.95 s, P<0.001), indicating a rapid, shallow breathing rhythm. In the airflow domain, while inspiratory flows were comparable, the CP group demonstrated significantly elevated mean and peak flows during the expiratory phase (P<0.001), reflecting compensatory respiratory effort. Spatially, CP patients presented significant ventilation redistribution, characterized by higher regional TIV in the right-anterior (ROI1) and left-posterior (ROI4) quadrants, but lower TIV in the left-anterior (ROI2) quadrant. In terms of diagnostic accuracy, the multi-modal ST-EIT model achieved the highest performance (AUC: 0.915±0.012, Accuracy: 0.843±0.019, F1-score: 0.872±0.017), substantially outperforming models based on spirometry (AUC: 0.721) or nasometry (AUC: 0.625) alone. Interpretability analysis revealed that spatial domain features were the most critical, contributing 53.4% to the model’s decision-making, followed by temporal (25.0%) and airflow (21.6%) features. ConclusionST-EIT successfully captures the temporal, airflow, and spatial deviations in CP speech respiration that are undetectable by conventional methods—specifically, rapid phase transitions, hyperdynamic expiratory airflow, and regional ventilation heterogeneity. This study validates ST-EIT as a robust, non-invasive, and radiation-free tool for characterizing speech-respiratory dysfunction, offering high clinical value for bedside screening, rehabilitation planning, and longitudinal monitoring of patients with cleft palate.
7.Spatiotemporal Electrical Impedance Tomography for Speech Respiratory Assessment in Cleft Palate: an Interpretable Machine Learning Study
Yang WU ; Xiao-Jing ZHANG ; Hao YU ; Cheng-Hui JIANG ; Bo SUN ; Jia-Feng YAO
Progress in Biochemistry and Biophysics 2026;53(2):485-500
ObjectiveCleft palate (CP) is a common congenital deformity often associated with velopharyngeal insufficiency (VPI), which disrupts the physiological coupling between respiration and speech. Conventional clinical assessments, such as nasometry and spirometry, provide limited static data and fail to visualize the dynamic spatiotemporal distribution of lung ventilation during phonation. This study introduces spatiotemporal electrical impedance tomography (ST-EIT) to evaluate speech-respiratory functional features in CP patients compared to normal controls (NC). The aim is to characterize multi-domain respiratory patterns and to validate an interpretable machine learning framework for providing objective, quantitative evidence for clinical assessment. MethodsSeventy-five participants were enrolled in this study, comprising 37 patients with surgically repaired CP and 38 healthy volunteers matched for age, gender, and body mass index (BMI). All subjects performed standardized sustained phonation tasks while undergoing synchronous monitoring with a 16-electrode EIT system and a pneumotachograph. A comprehensive feature engineering pipeline was developed to extract physiological parameters across 3 complementary domains. (1) Temporal domain: including inspiratory/expiratory phase duration (tPhase), time constants (Tau), and inspiratory-to-expiratory time ratios (TI/TE); (2) airflow domain: comprising mean flow, peak flow, and instantaneous flow at 25%, 50%, and 75% of tidal volume; and (3) spatial domain: quantifying global and regional tidal impedance variation (TIV), global inhomogeneity (GI), and center of ventilation (CoV). Extreme Gradient Boosting (XGBoost) classifiers were trained using 5 distinct data sources (Spirometry, Nasometry, Inspiratory-EIT, Expiratory-EIT, and fused ST-EIT). Model performance was rigorously evaluated via stratified 5-fold cross-validation, and Shapley additive explanations (SHAP) were employed to quantify global and local feature contributions. ResultsThe CP group exhibited a distinct respiratory phenotype compared to controls. In the temporal domain, CP patients showed significantly shorter inspiratory (1.60 s vs.1.85 s, P<0.001) and expiratory phase durations (2.45 s vs. 3.95 s, P<0.001), indicating a rapid, shallow breathing rhythm. In the airflow domain, while inspiratory flows were comparable, the CP group demonstrated significantly elevated mean and peak flows during the expiratory phase (P<0.001), reflecting compensatory respiratory effort. Spatially, CP patients presented significant ventilation redistribution, characterized by higher regional TIV in the right-anterior (ROI1) and left-posterior (ROI4) quadrants, but lower TIV in the left-anterior (ROI2) quadrant. In terms of diagnostic accuracy, the multi-modal ST-EIT model achieved the highest performance (AUC: 0.915±0.012, Accuracy: 0.843±0.019, F1-score: 0.872±0.017), substantially outperforming models based on spirometry (AUC: 0.721) or nasometry (AUC: 0.625) alone. Interpretability analysis revealed that spatial domain features were the most critical, contributing 53.4% to the model’s decision-making, followed by temporal (25.0%) and airflow (21.6%) features. ConclusionST-EIT successfully captures the temporal, airflow, and spatial deviations in CP speech respiration that are undetectable by conventional methods—specifically, rapid phase transitions, hyperdynamic expiratory airflow, and regional ventilation heterogeneity. This study validates ST-EIT as a robust, non-invasive, and radiation-free tool for characterizing speech-respiratory dysfunction, offering high clinical value for bedside screening, rehabilitation planning, and longitudinal monitoring of patients with cleft palate.
8.Resolution Assessment in Super-resolution Optical Microscopy: Adaptive Methods and Recent Advances
San-Hua FANG ; Jing-Yao CHEN ; Dan YANG ; Li LIU
Progress in Biochemistry and Biophysics 2026;53(4):805-825
Optical microscopy is essential for exploring biological and material structures, with resolution determining the level of observable detail. The advent of super-resolution fluorescence microscopy has broken the diffraction limit, achieving nanoscale resolution. However, traditional assessment methods, such as the Rayleigh criterion and point spread function (PSF) width measurement, rely on empirical judgments and diffraction-limited models, rendering them inadequate for modern super-resolution imaging. This review systematically traces the evolution of resolution assessment methodologies, from classical criteria to advanced strategies tailored for various super-resolution modalities. We first discuss Fourier-based quantitative methods. Fourier ring correlation (FRC) and its 3D counterpart, Fourier shell correlation (FSC), objectively determine resolution by evaluating the statistical correlation of two independent image reconstructions in frequency space. These methods offer robustness against noise and provide a global resolution metric, but they require data independence and are computationally intensive. They have become the prevailing standards in electron and super-resolution microscopy. Subsequently, we examine adaptations for specific super-resolution techniques. For single-molecule localization microscopy (SMLM) techniques such as PALM and STORM, the Fourier image resolution (FIRE) method extends FRC by incorporating a physical model that accounts for localization precision and labeling density. For stimulated emission depletion (STED) microscopy and other nonlinear techniques, assessment strategies differ. While PSF shrinkage measurements using fluorescent beads are useful for system calibration, evaluating the effective resolution directly on biological samples is more practical. This is typically performed via linewidth analysis of known structures (e.g., microtubules) or edge-spread function measurements, capturing the effects of photobleaching and sample-induced aberrations. A major paradigm shift is parameter-free resolution estimation based on decorrelation analysis. This method analyzes the autocorrelation decay of a single image’s Fourier spectrum to identify the cutoff spatial frequency without requiring dual datasets or user-defined thresholds. Its high efficiency and broad applicability have been validated across widefield, confocal, STED, SIM, and SMLM modalities. Optimized rendering strategies for SMLM data further enhance its accuracy, and it is emerging as a tool for real-time optimization of experimental parameters. The review also addresses the “gold standard” of resolution validation using well-defined nanostructures, such as DNA origami and nuclear pore complexes, which provide ground truth for verifying resolution claims and detecting artifacts. In the era of artificial intelligence, deep learning plays a dual role: it powerfully enhances image resolution but also introduces challenges, as models may generate “hallucinations” or false details. This underscores the need for new validation metrics to verify the physical fidelity of AI-generated content. Finally, we outline future directions: developing unified cross-modality standards, enabling real-time dynamic resolution monitoring for live-cell imaging, creating techniques for generating local resolution maps to capture sample heterogeneity, and integrating intelligent error correction to ensure data veracity. By providing a comprehensive overview of resolution assessment progress and challenges, this review aims to equip researchers with the knowledge to select appropriate tools, thereby fostering rigorous quantitative imaging in the life and material sciences.
9.Three-dimensional Electrical Impedance Tomography for Monitoring Gastric Hemorrhage
Zi-Han ZHAO ; Bo SUN ; Jing-Shi HUANG ; Zhi-Wei LI ; Yang WU ; Nan LI ; Jia-Feng YAO ; Tong ZHAO
Progress in Biochemistry and Biophysics 2026;53(4):1062-1075
ObjectiveGastric hemorrhage is one of the most common and life-threatening emergencies of the upper digestive tract. Early identification and continuous monitoring are essential for reducing rebleeding rates and mortality, particularly within the critical early hours after onset. Although endoscopy and radiological imaging can accurately localize bleeding sites, these approaches are invasive, resource-intensive, and unsuitable for continuous bedside monitoring. Electrical impedance tomography (EIT), as a noninvasive and radiation-free functional imaging technique, offers real-time visualization of conductivity distribution and has the potential for detecting intragastric bleeding based on the electrical contrast between blood and surrounding gastric tissues. In this study, a three-dimensional gastric EIT (3D-gEIT) framework is proposed to achieve noninvasive, real-time, and dynamic monitoring of gastric hemorrhage, with emphasis on spatial localization and quantitative volume assessment. MethodsA three-dimensional upper-abdominal simulation model incorporating the stomach, gastric wall, gastric contents, and surrounding tissues was established. Three electrode configurations, namely the dual layer ring, the four layer staggered ring, and the opposed dual plane array, were designed and systematically compared to evaluate their influence on depth sensitivity and spatial resolution. Based on the Tikhonov-Noser hybrid regularization scheme, a region-clustering constraint was introduced to develop the TK-Noser-RCC algorithm. This approach aggregates spatially adjacent elements with similar conductivity variations, thereby enhancing structural continuity and suppressing isolated noise artifacts. To validate the proposed framework, an upper-abdominal physical phantom was constructed using agar to simulate background tissue conductivity. Hemispherical high-conductivity inclusions with volumes ranging from 10 ml to 50 ml were attached to the inner gastric wall to mimic localized bleeding under different gastric filling states. Boundary voltages were acquired under a 120 kHz excitation current and reconstructed using the TK-Noser-RCC algorithm. Furthermore, an in vivo animal experiment was performed using a porcine model with adult-scale abdominal dimensions. A total of 100 ml of autologous blood was injected incrementally into the stomach to simulate progressive gastric hemorrhage, and time-difference EIT reconstruction was conducted at each injection stage to assess the dynamic system response under physiological conditions. ResultsSimulation results demonstrated that the opposed dual-plane electrode array achieved superior depth sensitivity distribution and spatial resolution. For a 40 ml hemorrhage model, the average ICC and SSIM improved by 55.9% and 38.8% compared with the dual-layer ring configuration, and by 64.0% and 39.5% compared with the four-layer staggered configuration. The proposed region-clustering constraint significantly enhanced reconstruction stability. Under added Gaussian noise of 40 dB and 30 dB, ICC values remained approximately 0.85, indicating effective artifact suppression and preservation of boundary integrity. In physical phantom experiments, reconstructed hemorrhage volumes increased approximately linearly with the preset hemispherical volumes, and the reconstructed high-conductivity regions closely matched the actual bleeding locations. Both empty-stomach and full-stomach conditions were evaluated, demonstrating that the opposed dual-plane configuration maintained stable imaging performance across varying gastric contents. In the animal experiment, reconstructed low-impedance regions expanded progressively with increasing injected blood volume. The spatial localization of the hemorrhage remained stable throughout the procedure, and no significant artifacts were observed. Quantitative analysis showed that reconstructed volume and average conductivity variation exhibited an approximately linear growth trend with injected blood volume, confirming the sensitivity of the system to dynamic intragastric conductivity changes. ConclusionThe proposed 3D-gEIT framework enables quantitative reconstruction of gastric hemorrhage volume and spatial distribution with improved depth sensitivity, structural continuity, and noise robustness compared with conventional EIT approaches. By integrating optimized electrode configuration and a region-clustering-constrained reconstruction algorithm, the system provides stable dynamic monitoring under both controlled phantom conditions and in vivo physiological environments. This method offers a noninvasive, real-time, and low-cost imaging strategy for early diagnosis, postoperative monitoring, and bedside surveillance of gastric bleeding.
10.Evidence-based evaluation and hierarchical management of off-label use of 5-aminolevulinic acid in photodynamic therapy
Jing MA ; Tingting LIU ; Xiaoshuang GOU ; Xue YANG ; Chen LI ; Fang LIU ; Yao LIU
China Pharmacy 2026;37(8):1056-1061
OBJECTIVE To provide reference for medical institutions to establish the record management mode and review rules of off-label use of 5-aminolevulinic acid (ALA) in photodynamic therapy based on the level of evidence. METHODS All ALA-containing outpatient prescriptions in the rational drug use system in our hospital from January 1, 2024 to December 31, 2025 were retrospectively collected. Based on the drug instructions, the current status of off-label use of ALA in photodynamic therapy was identified . The relevant studies in Micromedex, PubMed, CNKI, Wanfang Data and other databases were systematically searched as the relevant evidence-based evidence of ALA off-label use. According to the Off-label Drug Use Filing Standard of the hospital,the evidence-based evaluation method was used to evaluate the evidence-based evidence of ALA off-label use and carry out hierarchical management. RESULTS A total of 1 803 effective prescriptions were included, of which 676 (37.49%) were off-label use, distributed in the dermatology department (564 prescriptions,83.43%) and the plastic surgery department (112 prescriptions,16.57%). All 676 prescriptions were off-indications medication, involving ten types of skin diseases, primarily including moderate to severe acne (39.94%), skin warts (25.44%), Bowen’s disease (11.98%), and others. According to evidence-based evidence,off-label uses such as moderate to severe acne, actinic keratosis, and Bowen’s disease were managed according to the evidence categoryⅠ orⅡ.The uses of extramammary Paget’s disease and rosacea were managed according to the evidence category Ⅲ.The uses of lichen sclerosus and keloids were managed according to the evidence category Ⅳ.The results of evidence-based evaluation showed that 92.01% of off-label use in our hospital had high-level evidence-based support ( evidence category was gradeⅠ-Ⅱ). CONCLUSIONS Off-label uses supported by high-level evidence, such as moderate to severe acne, skin warts, and Bowen’s disease, can be managed under filing category Ⅰ or Ⅱ. For the use of lichen sclerosus and keloids, evidence-based evidence is insufficient and should be strictly restricted.The vast majority of ALA off-label use in our hospital has sufficient evidence-based basis.

Result Analysis
Print
Save
E-mail