1.Design and application of novel protective ventilator circuit component
Wei-zhou WU ; Kang LU ; Jing-jie CAO ; Zhi-hua ZHAO ; Hai-tao LAN ; Zan-chao CHEN ; Qing-feng XUE
Chinese Medical Equipment Journal 2025;46(4):113-117
Objective To develop a novel protective ventilator circuit component and to verify its performance by water seal and anti-splash experiments.Methods A novel protective ventilator circuit component had a design scheme with the multifunctional joint,and consisted of a tee connection tube,an isolation sleeve and a stop sleeve,of which,the tee connection tube was made of polyethylene polymer material and the others were made of silicone material.The tee connection tube had a T-shaped structure with two standard connection ports,which was composed of an adapter,a sealing cap,a plug and a sealing ring;the isolation sleeve was in the shape of a cylinder with a raised bottom,which was inserted into the adapter;the stop sleeve was located in the isolation sleeve,with an inverted frustum of a cone at the bottom and a rounded hole in the middle of the inverted frustum.An open ventilator circuit tube was involved in the performance verification of the circuit component developed.In the water seal experiment,sputum aspiration was simulated and the heights of the liquid level drop in the L-shaped tubes were compared after sputum aspiration.In the anti-splash experiment,the infection rates on the surfaces of the sterile hole towels and gloves were calculated.Results Water seal experiment showed after sputum aspiration the open ventilator circuit tube had the liquid level at the L-shaped tube higher significantly than that of the circuit component;the anti-splash experiment indicated sputum aspiration resulted in the occurance of the splashing out of the secretion and 77.5%infection rate by the open ventilator circuit tube,while no splashing out and 0%infection rate by the circuit component developed.Conclusion The novel protective ventilator circuit component behaves well in sealing and anti-splashing,and thus is worthy of clinical application for sputum aspiration.[Chinese Medical Equipment Journal,2025,46(4):113-117]
2.Comparison of differences in dosimetry and treatment efficiency of modified radiotherapy plans after left-sided breast-conserving surgery
Jian-hai LIN ; Jing FENG ; Zhong-hua CHEN ; Zhi-chao FU ; Jie CHEN ; Nan-bao ZHONG
Chinese Medical Equipment Journal 2025;46(4):45-51
Objective To compare the differences in dosimetry and treatment efficiency of three radiotherapy plans after left-sided breast-conserving surgery,including modified intensity-modulated radiation therapy(IMRT),cross-field volume-modulated arc therapy(VMAT)or improved VMAT,so as to provide references for clinical practice.Methods Three radiotherapy plans of modified IMRT,cross-field VMAT and improved VMAT were designed for 12 patients after left-sided-breast-conserving surgery.The modified IMRT with five irradiation fields and the improved VMAT with two arcs were modified by not setting cross-fields while determining the start and end angles with the rays passing through the least lung area.The cross-field VMAT had its start and end angles set based on the cross-fields.The doses to the target areas,peripheral organs at risk,heart and its substructures were evaluated,and dose verification was carried out.The three plans were compared in terms of treatment efficiency and gamma pass rate.SPSS 22.0 was used for statistical analysis.Results All the three plans behaved well in dose distribution.In terms of planning gross tumor volume dosimetry dosimetry,the improved VMAT and modified IMRT gained advantages than others in CI and D50,respectively,with the differences being significant(all P<0.05).In terms of planning target volume dosimetry,the modified IMRT had the V107 and D50 lower than those of the others,with the differences being significant(P<0.05).In terms of the protection of peripheral organs at risk,V5 of the left lung,Dmean of the right lung and Dmean of the healthy breast were lower in the modified IMRT plan than in the other 2 plans,with statistically significant differences(P<0.05);V20,V30,V35 and V40 of the left lung were lower in the modified VMAT plan than in the other 2 plans,with statistically significant differences(P<0.05).In terms of protection of heart and its substructures,the left ventricle V20,V30 and Dmean of the improved VMAT plan behaved better than those of other 2 plans,and the difference was statistically significant(all P<0.05).In terms of treatment efficiency,the cross-field VMAT plan had the lowest MU while highest treatment efficiency;the improved VMAT plan had the MU higher while the treatment efficiency lower than the cross-field VMAT plan;the modified IMRT plan had the highest MU while the lowest gamma pass rate,and the differences in the MUs and gamma pass rates among the three plans were statistically significant(P<0.05).Conclusion Under the same standard conditions,the cross-field VMAT and improved VMAT plans show technical advantages.Though the improved VMAT plan has the treatment efficiency lower than the cross-field VMAT,it decreases the possibility of radiocardiac injury in terms of dosimetry and thus can be used for radiotherapy after left-sided breast-conserving surgery.[Chinese Medical Equipment Journal,2025,46(4):45-51]
3.Design and application of novel protective ventilator circuit component
Wei-zhou WU ; Kang LU ; Jing-jie CAO ; Zhi-hua ZHAO ; Hai-tao LAN ; Zan-chao CHEN ; Qing-feng XUE
Chinese Medical Equipment Journal 2025;46(4):113-117
Objective To develop a novel protective ventilator circuit component and to verify its performance by water seal and anti-splash experiments.Methods A novel protective ventilator circuit component had a design scheme with the multifunctional joint,and consisted of a tee connection tube,an isolation sleeve and a stop sleeve,of which,the tee connection tube was made of polyethylene polymer material and the others were made of silicone material.The tee connection tube had a T-shaped structure with two standard connection ports,which was composed of an adapter,a sealing cap,a plug and a sealing ring;the isolation sleeve was in the shape of a cylinder with a raised bottom,which was inserted into the adapter;the stop sleeve was located in the isolation sleeve,with an inverted frustum of a cone at the bottom and a rounded hole in the middle of the inverted frustum.An open ventilator circuit tube was involved in the performance verification of the circuit component developed.In the water seal experiment,sputum aspiration was simulated and the heights of the liquid level drop in the L-shaped tubes were compared after sputum aspiration.In the anti-splash experiment,the infection rates on the surfaces of the sterile hole towels and gloves were calculated.Results Water seal experiment showed after sputum aspiration the open ventilator circuit tube had the liquid level at the L-shaped tube higher significantly than that of the circuit component;the anti-splash experiment indicated sputum aspiration resulted in the occurance of the splashing out of the secretion and 77.5%infection rate by the open ventilator circuit tube,while no splashing out and 0%infection rate by the circuit component developed.Conclusion The novel protective ventilator circuit component behaves well in sealing and anti-splashing,and thus is worthy of clinical application for sputum aspiration.[Chinese Medical Equipment Journal,2025,46(4):113-117]
4.Comparison of differences in dosimetry and treatment efficiency of modified radiotherapy plans after left-sided breast-conserving surgery
Jian-hai LIN ; Jing FENG ; Zhong-hua CHEN ; Zhi-chao FU ; Jie CHEN ; Nan-bao ZHONG
Chinese Medical Equipment Journal 2025;46(4):45-51
Objective To compare the differences in dosimetry and treatment efficiency of three radiotherapy plans after left-sided breast-conserving surgery,including modified intensity-modulated radiation therapy(IMRT),cross-field volume-modulated arc therapy(VMAT)or improved VMAT,so as to provide references for clinical practice.Methods Three radiotherapy plans of modified IMRT,cross-field VMAT and improved VMAT were designed for 12 patients after left-sided-breast-conserving surgery.The modified IMRT with five irradiation fields and the improved VMAT with two arcs were modified by not setting cross-fields while determining the start and end angles with the rays passing through the least lung area.The cross-field VMAT had its start and end angles set based on the cross-fields.The doses to the target areas,peripheral organs at risk,heart and its substructures were evaluated,and dose verification was carried out.The three plans were compared in terms of treatment efficiency and gamma pass rate.SPSS 22.0 was used for statistical analysis.Results All the three plans behaved well in dose distribution.In terms of planning gross tumor volume dosimetry dosimetry,the improved VMAT and modified IMRT gained advantages than others in CI and D50,respectively,with the differences being significant(all P<0.05).In terms of planning target volume dosimetry,the modified IMRT had the V107 and D50 lower than those of the others,with the differences being significant(P<0.05).In terms of the protection of peripheral organs at risk,V5 of the left lung,Dmean of the right lung and Dmean of the healthy breast were lower in the modified IMRT plan than in the other 2 plans,with statistically significant differences(P<0.05);V20,V30,V35 and V40 of the left lung were lower in the modified VMAT plan than in the other 2 plans,with statistically significant differences(P<0.05).In terms of protection of heart and its substructures,the left ventricle V20,V30 and Dmean of the improved VMAT plan behaved better than those of other 2 plans,and the difference was statistically significant(all P<0.05).In terms of treatment efficiency,the cross-field VMAT plan had the lowest MU while highest treatment efficiency;the improved VMAT plan had the MU higher while the treatment efficiency lower than the cross-field VMAT plan;the modified IMRT plan had the highest MU while the lowest gamma pass rate,and the differences in the MUs and gamma pass rates among the three plans were statistically significant(P<0.05).Conclusion Under the same standard conditions,the cross-field VMAT and improved VMAT plans show technical advantages.Though the improved VMAT plan has the treatment efficiency lower than the cross-field VMAT,it decreases the possibility of radiocardiac injury in terms of dosimetry and thus can be used for radiotherapy after left-sided breast-conserving surgery.[Chinese Medical Equipment Journal,2025,46(4):45-51]
5.Effects of different nerve blocks under ultrasound guidance on inflammatory factors and cognitive function after total hip replacement in the elderly
Hai-lu XIA ; Jie LIU ; Xin LIU ; Jing-jing CUI ; Jian-hua WANG ; Yu-mo JING
Journal of Regional Anatomy and Operative Surgery 2025;34(3):223-227
Objective To explore the effects of different nerve blocks under ultrasound guidance on the expression of inflammatory factors after total hip replacement in the elderly,and its correlation with postoperative cognitive dysfunction(POCD).Methods A total of 100 elderly patients who underwent total hip replacement in our hospital from February to November 2023 were selected as the research objects,and they were divided into the femoral nerve block(FNB)group and the pericapsule nerve group block(PNGB)group according to different nerve block methods during the operation.The expression of inflammatory factors such as serum interleukin-1β(IL-1β),interleukin-6(IL-6),interleukin-10(IL-10),tumor necrosis factor-α(TNF-α)and tumor necrosis factor-β(TNF-β)1 day before surgery,6 hours after anesthesia,1 day after surgery,and 3 days after surgery of patients in the two groups were compared.The cognitive function of patients was evaluated by the mini-mental state examination(MMSE)score,and the pain of patients was evaluated by visual analogue scale(VAS)score.GEE model was used to evaluate the effects of two kinds of nerve block on the expression of inflammatory factors.Logistic regression was used to analyzed the correlation between postoperative inflammatory factors and POCD in patients.Results The levels of IL-1β,IL-6,IL-10,TNF-α and TNF-β 1 day after operation in the PNGB group were higher than those in the FNB group,and the differences were statistically significant(P<0.05).The MMSE score 1 day after surgery in the PNGB group was significantly higher than that in the FNB group(P<0.05),and the VAS score 3 days after surgery was significantly lower than that in the FNB group(P<0.05).GEE model showed that PNGB has a greater impact on IL-1β,IL-6,IL-10,TNF-α,and TNF-β.IL-1β,IL-6,IL-10,TNF-α,and TNF-β were all independently related to POCD induced by two different nerve blocks(P<0.05).Conclusion PNGB can effectively inhibit pro-inflammatory factors,reduce inflammatory stress responses,and maintain the balance of inflammatory factors.Inflammatory factors are independently related to POCD induced by different nerve blocks.With the occurrence of inflammatory stress response,the risk of POCD in patients increases.
6.Quality inspection of ultrasound soft tissue cutting hemostatic equipment
Jing HUANG ; Qi-di SUN ; Ao-wen DUAN ; Li XU ; Heng-yu LONG ; Hai-jiang ZHU ; He-hua ZHANG
Chinese Medical Equipment Journal 2025;46(10):49-53
Objective To carry out quality inspection of the ultrasound soft tissue cutting hemostatic equipment to ensure its safety and effectiveness.Methods Five brands of ultrasound soft tissue cutting hemostatic equipment were selected and noted as test equipment A,test equipment B,test equipment C,test equipment D and test equipment E,which underwent quality inspection in terms of tip main amplitude,tip lateral amplitude,tip vibration frequency,excitation frequency,static electrical power and contact current based on YY/T 0644-2008 Ultrasonics-surgical systems—Measurement and declaration of the basic output characteristics,YY/T 1750-2020 Ultrasonic surgical equipmetn for soft tissue excision and hemostasia and GB 9706.1-2020 Medical electrical equipment—Part 1:General requirements for basic safety and essential performance.Results The test data of the five brands in terms of tip main amplitude,tip lateral amplitude,tip vibration frequency,excitation frequency,static electrical power and contact current met the technical requirements of YY/T 0644-2008,YY/T 1750-2020,GB 9706.1-2020.Conclusion The quality inspection of the ultrasound soft tissue cutting hemostatic equipment contributes to enhancing the accuracy and stability of the equipment and decreasing the risk during its clinical application.[Chinese Medical Equipment Journal,2025,46(10):49-53]
7.The regulation and mechanism of apolipoprotein A5 on myocardial lipid deposition.
Xiao-Jie YANG ; Jiang LI ; Jing-Yuan CHEN ; Teng-Teng ZHU ; Yu-Si CHEN ; Hai-Hua QIU ; Wen-Jie CHEN ; Xiao-Qin LUO ; Jun LUO
Acta Physiologica Sinica 2025;77(1):35-46
The current study aimed to clarify the roles of apolipoprotein A5 (ApoA5) and milk fat globule-epidermal growth factor 8 (Mfge8) in regulating myocardial lipid deposition and the regulatory relationship between them. The serum levels of ApoA5 and Mfge8 in obese and healthy people were compared, and the obesity mouse model induced by the high-fat diet (HFD) was established. In addition, primary cardiomyocytes were purified and identified from the hearts of suckling mice. The 0.8 mmol/L sodium palmitate treatment was used to establish the lipid deposition cardiomyocyte model in vitro. ApoA5-overexpressing adenovirus was used to observe its effects on cardiac function and lipids. The expressions of the fatty acid uptake-related molecules and Mfge8 on transcription or translation levels were detected. Co-immunoprecipitation was used to verify the interaction between ApoA5 and Mfge8 proteins. Immunofluorescence was used to observe the co-localization of Mfge8 protein with ApoA5 or lysosome-associated membrane protein 2 (LAMP2). Recombinant rMfge8 was added to cardiomyocytes to investigate the regulatory mechanism of ApoA5 on Mfge8. The results showed that participants in the simple obesity group had a significant decrease in serum ApoA5 levels (P < 0.05) and a significant increase in Mfge8 levels (P < 0.05) in comparison with the healthy control group. The adenovirus treatment successfully overexpressed ApoA5 in HFD-fed obese mice and palmitic acid-induced lipid deposition cardiomyocytes, respectively. ApoA5 reduced the weight of HFD-fed obese mice (P < 0.05), shortened left ventricular isovolumic relaxation time (IVRT), increased left ventricular ejection fraction (LVEF), and significantly reduced plasma levels of triglycerides (TG) and cholesterol (CHOL) (P < 0.05). In myocardial tissue and cardiomyocytes, the overexpression of ApoA5 significantly reduced the deposition of TG (P < 0.05), transcription of fatty acid translocase (FAT/CD36) (P < 0.05), fatty acid-binding protein (FABP) (P < 0.05), and fatty acid transport protein (FATP) (P < 0.05), and protein expression of Mfge8 (P < 0.05), while the transcription levels of Mfge8 were not significantly altered (P > 0.05). In vitro, the Mfge8 protein was captured using ApoA5 as bait protein, indicating a direct interaction between them. Overexpression of ApoA5 led to an increase in co-localization of Mfge8 with ApoA5 or LAMP2 in cardiomyocytes under lipid deposition status. On this basis, exogenous added recombinant rMfge8 counteracted the improvement of lipid deposition in cardiomyocytes by ApoA5. The above results indicate that the overexpression of ApoA5 can reduce fatty acid uptake in myocardial cells under lipid deposition status by regulating the content and cellular localization of Mfge8 protein, thereby significantly reducing myocardial lipid deposition and improving cardiac diastolic and systolic function.
Animals
;
Humans
;
Mice
;
Myocytes, Cardiac/metabolism*
;
Obesity/physiopathology*
;
Male
;
Apolipoprotein A-V/blood*
;
Lipid Metabolism/physiology*
;
Milk Proteins/blood*
;
Myocardium/metabolism*
;
Diet, High-Fat
;
Antigens, Surface/physiology*
;
Mice, Inbred C57BL
;
Cells, Cultured
;
Female
8.International clinical practice guideline on the use of traditional Chinese medicine for functional dyspepsia (2025).
Sheng-Sheng ZHANG ; Lu-Qing ZHAO ; Xiao-Hua HOU ; Zhao-Xiang BIAN ; Jian-Hua ZHENG ; Hai-He TIAN ; Guan-Hu YANG ; Won-Sook HONG ; Yu-Ying HE ; Li LIU ; Hong SHEN ; Yan-Ping LI ; Sheng XIE ; Jin SHU ; Bin-Fang ZENG ; Jun-Xiang LI ; Zhen LIU ; Zheng-Hua XIAO ; Jing-Dong XIAO ; Pei-Yong ZHENG ; Shao-Gang HUANG ; Sheng-Liang CHEN ; Gui-Jun FEI
Journal of Integrative Medicine 2025;23(5):502-518
Functional dyspepsia (FD), characterized by persistent or recurrent dyspeptic symptoms without identifiable organic, systemic or metabolic causes, is an increasingly recognized global health issue. The objective of this guideline is to equip clinicians and nursing professionals with evidence-based strategies for the management and treatment of adult patients with FD using traditional Chinese medicine (TCM). The Guideline Development Group consulted existing TCM consensus documents on FD and convened a panel of 35 clinicians to generate initial clinical queries. To address these queries, a systematic literature search was conducted across PubMed, EMBASE, the Cochrane Library, China National Knowledge Infrastructure (CNKI), VIP Database, China Biology Medicine (SinoMed) Database, Wanfang Database, Traditional Medicine Research Data Expanded (TMRDE), and the Traditional Chinese Medical Literature Analysis and Retrieval System (TCMLARS). The evidence from the literature was critically appraised using the Grading of Recommendations Assessment, Development, and Evaluation (GRADE) approach. The strength of the recommendations was ascertained through a consensus-building process involving TCM and allopathic medicine experts, methodologists, pharmacologists, nursing specialists, and health economists, leveraging their collective expertise and empirical knowledge. The guideline comprises a total of 43 evidence-informed recommendations that span a range of clinical aspects, including the pathogenesis according to TCM, diagnostic approaches, therapeutic interventions, efficacy assessments, and prognostic considerations. Please cite this article as: Zhang SS, Zhao LQ, Hou XH, Bian ZX, Zheng JH, Tian HH, Yang GH, Hong WS, He YY, Liu L, Shen H, Li YP, Xie S, Shu J, Zeng BF, Li JX, Liu Z, Xiao ZH, Xiao JD, Zheng PY, Huang SG, Chen SL, Fei GJ. International clinical practice guideline on the use of traditional Chinese medicine for functional dyspepsia (2025). J Integr Med. 2025; 23(5):502-518.
Dyspepsia/drug therapy*
;
Humans
;
Medicine, Chinese Traditional/methods*
;
Practice Guidelines as Topic
;
Drugs, Chinese Herbal/therapeutic use*
10.Quality inspection of ultrasound soft tissue cutting hemostatic equipment
Jing HUANG ; Qi-di SUN ; Ao-wen DUAN ; Li XU ; Heng-yu LONG ; Hai-jiang ZHU ; He-hua ZHANG
Chinese Medical Equipment Journal 2025;46(10):49-53
Objective To carry out quality inspection of the ultrasound soft tissue cutting hemostatic equipment to ensure its safety and effectiveness.Methods Five brands of ultrasound soft tissue cutting hemostatic equipment were selected and noted as test equipment A,test equipment B,test equipment C,test equipment D and test equipment E,which underwent quality inspection in terms of tip main amplitude,tip lateral amplitude,tip vibration frequency,excitation frequency,static electrical power and contact current based on YY/T 0644-2008 Ultrasonics-surgical systems—Measurement and declaration of the basic output characteristics,YY/T 1750-2020 Ultrasonic surgical equipmetn for soft tissue excision and hemostasia and GB 9706.1-2020 Medical electrical equipment—Part 1:General requirements for basic safety and essential performance.Results The test data of the five brands in terms of tip main amplitude,tip lateral amplitude,tip vibration frequency,excitation frequency,static electrical power and contact current met the technical requirements of YY/T 0644-2008,YY/T 1750-2020,GB 9706.1-2020.Conclusion The quality inspection of the ultrasound soft tissue cutting hemostatic equipment contributes to enhancing the accuracy and stability of the equipment and decreasing the risk during its clinical application.[Chinese Medical Equipment Journal,2025,46(10):49-53]

Result Analysis
Print
Save
E-mail