1.MRI findings of spinal cord atrophy after spinal cord injury in children and their injury level
Yingxin ZHANG ; Genlin LIU ; Di CHEN ; Hongxia ZHANG ; Yifan TIAN ; Yiji WANG ; Yang JING ; Ruidong CHENG ; Shaomin ZHANG ; Jiafeng YAO ; Bo SUN ; Xiaomeng SUN
Chinese Journal of Rehabilitation Theory and Practice 2026;32(4):387-392
ObjectiveTo delineate imaging findings using an imaging platform and investigate the correlation between MRI characteristics of spinal cord atrophy and clinical diagnosis in children with spinal cord injury (SCI). MethodsImaging data of 150 children with SCI admitted to Beijing Bo'ai Hospital, China Rehabilitation Research Center, from January, 2002 to March, 2024 were collected and imported into the imaging platform. The anteroposterior and transverse diameters of the middle part of the spinal cord at the cross-section with the most severe atrophy were measured, and the relevant indicators of the previous normal spinal cord segment were measured as controls; the radiomic features were extracted. Clinical data of the children including gender, age, cause of injury, sensory level, motor level, spinal cord injury level, injury severity and disease course were collected. ResultsSpinal cord atrophy was identified in 81 cases (54%), among which 78 cases (96%) were American Spinal Injury Association Impairment Scale (AIS) grade A and 3 cases (4%) were AIS grade C. The upper boundary of the spinal cord atrophy site strongly correlated with the injury level, motor level and sensory level (r > 0.8, P < 0.001). ConclusionMore than half of children with SCI may develop secondary spinal cord atrophy, the vast majority of whom suffer from complete spinal cord injury; the upper boundary of spinal cord atrophy is correlated with the injury level.
2.Preliminary study of the value of ultrasound parameters combined with cystatin C in monitoring early acute kidney injury after liver transplantation
Di ZHANG ; Jing SUN ; Kai ZHAO ; Chuanshen XU ; Shiwen DING ; Jinzhen CAI ; Jianhong WANG
Organ Transplantation 2025;16(4):574-581
Objective To explore the value of combined ultrasound parameters, including the hepatorenal index (HRI) and renal resistance index (RRI), with cystatin C (CysC) in monitoring early acute kidney injury (AKI) after liver transplantation. Methods Perioperative data from 121 liver transplant recipients who received organs from donation after brain death were collected. The HRI and RRI of the recipients were measured on postoperative days 1-7 and at 1 month, and the CysC levels were measured on postoperative day 1. The recipients were divided into the AKI group (n=53) and the non-AKI group (n=68) based on whether AKI occurred within 7 days after operation. The data of the two groups were compared, and the ultrasound parameters before and after recovery in the AKI group were analyzed. The value of combined HRI, RRI and CysC in monitoring AKI was also analyzed. Results AKI occurred in 53 recipients, with an incidence rate of 43.8%, including 30 cases of stage 1, 18 cases of stage 2, and 5 cases of stage 3. Among them, 49 cases occurred on postoperative day 1, and 4 cases occurred on postoperative day 2. Of these, 43 cases recovered within 7 days after surgery, 8 cases recovered within 2 months after surgery, 1 case was lost to follow-up, and 1 case received renal replacement therapy. The body mass index and preoperative CysC levels were higher in the AKI group than in the non-AKI group, and the operative time was longer in the AKI group than in the non-AKI group (all P < 0.05). The HRI on postoperative day 1 was lower in the AKI group than in the non-AKI group, while the RRI and CysC levels were higher (all P < 0.05). When AKI occurred, the HRI was lower than the baseline level, and the RRI was higher than the baseline level. As AKI recovered, the HRI gradually increased, and the RRI gradually decreased. The receiver operating characteristic curve analysis showed that the sensitivity and specificity of HRI ≤ 1.12 for predicting AKI were 0.623 and 0.878, respectively, with an area under the curve (AUC) of 0.801. The sensitivity and specificity of RRI ≥ 0.65 for predicting AKI were 0.878 and 0.676, respectively, with an AUC of 0.825. The sensitivity and specificity of CysC ≥ 1.38 mg/L for predicting AKI were 0.736 and 0.882, respectively, with an AUC of 0.851 (all P<0.01). The combination of HRI and CysC (AUC=0.897, P<0.01), RRI and CysC (AUC=0.910, P<0.01), and all three parameters combined (AUC=0.934, P<0.01) were more effective than using each parameter alone. Conclusions HRI and RRI may be used to monitor the occurrence and recovery of early AKI after liver transplantation. The combination of these two parameters with CysC has a high application value in monitoring early AKI after liver transplantation.
3.Percutaneous coronary intervention vs . medical therapy in patients on dialysis with coronary artery disease in China.
Enmin XIE ; Yaxin WU ; Zixiang YE ; Yong HE ; Hesong ZENG ; Jianfang LUO ; Mulei CHEN ; Wenyue PANG ; Yanmin XU ; Chuanyu GAO ; Xiaogang GUO ; Lin CAI ; Qingwei JI ; Yining YANG ; Di WU ; Yiqiang YUAN ; Jing WAN ; Yuliang MA ; Jun ZHANG ; Zhimin DU ; Qing YANG ; Jinsong CHENG ; Chunhua DING ; Xiang MA ; Chunlin YIN ; Zeyuan FAN ; Qiang TANG ; Yue LI ; Lihua SUN ; Chengzhi LU ; Jufang CHI ; Zhuhua YAO ; Yanxiang GAO ; Changan YU ; Jingyi REN ; Jingang ZHENG
Chinese Medical Journal 2025;138(3):301-310
BACKGROUND:
The available evidence regarding the benefits of percutaneous coronary intervention (PCI) on patients receiving dialysis with coronary artery disease (CAD) is limited and inconsistent. This study aimed to evaluate the association between PCI and clinical outcomes as compared with medical therapy alone in patients undergoing dialysis with CAD in China.
METHODS:
This multicenter, retrospective study was conducted in 30 tertiary medical centers across 12 provinces in China from January 2015 to June 2021 to include patients on dialysis with CAD. The primary outcome was major adverse cardiovascular events (MACE), defined as a composite of cardiovascular death, non-fatal myocardial infarction, and non-fatal stroke. Secondary outcomes included all-cause death, the individual components of MACE, and Bleeding Academic Research Consortium criteria types 2, 3, or 5 bleeding. Multivariable Cox proportional hazard models were used to assess the association between PCI and outcomes. Inverse probability of treatment weighting (IPTW) and propensity score matching (PSM) were performed to account for potential between-group differences.
RESULTS:
Of the 1146 patients on dialysis with significant CAD, 821 (71.6%) underwent PCI. After a median follow-up of 23.0 months, PCI was associated with a 43.0% significantly lower risk for MACE (33.9% [ n = 278] vs . 43.7% [ n = 142]; adjusted hazards ratio 0.57, 95% confidence interval 0.45-0.71), along with a slightly increased risk for bleeding outcomes that did not reach statistical significance (11.1% vs . 8.3%; adjusted hazards ratio 1.31, 95% confidence interval, 0.82-2.11). Furthermore, PCI was associated with a significant reduction in all-cause and cardiovascular mortalities. Subgroup analysis did not modify the association of PCI with patient outcomes. These primary findings were consistent across IPTW, PSM, and competing risk analyses.
CONCLUSION
This study indicated that PCI in patients on dialysis with CAD was significantly associated with lower MACE and mortality when comparing with those with medical therapy alone, albeit with a slightly increased risk for bleeding events that did not reach statistical significance.
Humans
;
Percutaneous Coronary Intervention/methods*
;
Male
;
Female
;
Coronary Artery Disease/drug therapy*
;
Retrospective Studies
;
Renal Dialysis/methods*
;
Middle Aged
;
Aged
;
China
;
Proportional Hazards Models
;
Treatment Outcome
4.Advances in the role of protein post-translational modifications in circadian rhythm regulation.
Zi-Di ZHAO ; Qi-Miao HU ; Zi-Yi YANG ; Peng-Cheng SUN ; Bo-Wen JING ; Rong-Xi MAN ; Yuan XU ; Ru-Yu YAN ; Si-Yao QU ; Jian-Fei PEI
Acta Physiologica Sinica 2025;77(4):605-626
The circadian clock plays a critical role in regulating various physiological processes, including gene expression, metabolic regulation, immune response, and the sleep-wake cycle in living organisms. Post-translational modifications (PTMs) are crucial regulatory mechanisms to maintain the precise oscillation of the circadian clock. By modulating the stability, activity, cell localization and protein-protein interactions of core clock proteins, PTMs enable these proteins to respond dynamically to environmental and intracellular changes, thereby sustaining the periodic oscillations of the circadian clock. Different types of PTMs exert their effects through distincting molecular mechanisms, collectively ensuring the proper function of the circadian system. This review systematically summarized several major types of PTMs, including phosphorylation, acetylation, ubiquitination, SUMOylation and oxidative modification, and overviewed their roles in regulating the core clock proteins and the associated pathways, with the goals of providing a theoretical foundation for the deeper understanding of clock mechanisms and the treatment of diseases associated with circadian disruption.
Protein Processing, Post-Translational/physiology*
;
Circadian Rhythm/physiology*
;
Humans
;
Animals
;
CLOCK Proteins/physiology*
;
Circadian Clocks/physiology*
;
Phosphorylation
;
Acetylation
;
Ubiquitination
;
Sumoylation
5.Application of the Anderson sampler in the inspection for the filtration efficiency for bacteria in medical mask
Di LEI ; Chen WANG ; Minjuan ZHANG ; Cunlin LONG ; Jian REN ; Zhijie ZHAO ; Yuwei LI ; Yun LING ; Xiaoning SUN ; Jing ZHAO
China Medical Equipment 2025;22(3):160-163
The medical mask,which is used as an important tool of preventing the spread of respiratory diseases,can effectively block the transmission of biological aerosols.The detection for the filtration efficiency of bacteria in medical mask is particular importance.The Andersen sampler,is one kind of device that samples microbial aerosols,is widely used in the inspection for the filtration efficiency for bacteria in medical masks.It mainly consists of six impactors with different pore sizes.It simulates the deposition process of the most of particles at different positions in respiratory system through the bacterial particles in biological aerosols impact respectively the surface of petri dishes with agar under different pore sizes.This paper explored the development background,structure and sampling principle,operation and counting procedures of the Andersen sampler,as well as its application and importance in the inspection for the filtration efficiency for bacteria in medical mask.
6.Bibliometric and Visual Analysis of the Application of in situ Simulation in Medical Field.
Peng-Xia SUN ; Di JIANG ; Shu-Ya LI ; Yan SHI ; Shao-Wen HU ; Jing CHEN ; Fan LI
Acta Academiae Medicinae Sinicae 2025;47(5):830-842
Objective To analyze the research status of in situ simulation in the medical field and explore its hotspots and trends. Methods Relevant literature was searched in China National Knowledge Infrastructure and Web of Science core collection from the inception to February 2024.CiteSpace 6.3.R1 was used to analyze the authors,institutions,and keywords and draw visual knowledge maps. Results A total of 25 Chinese articles and 438 English articles were included.Only 14 English articles were from China.In Chinese articles,the authors with the largest number of articles were Dai Hengmao and Liu Shangkun,and the institution with the largest number of articles was Tongji Hospital affiliated to Tongji Medical College of Huazhong University of Science and Technology.There was little cooperation between the authors and institutions.In English articles,the author and institution with the largest number of articles was Auerbach Marc and Yale University,respectively,and the cooperation between authors and institutions was close.Emergency medicine,emergency event handling,and on-the-job training were the keywords with high frequency in Chinese articles.Patient safety,medical education,and cardiac arrest were the keywords with high frequency in English articles.A total of 4 clusters were generated for Chinese keywords and 13 clusters for English keywords. Conclusions The application of in situ simulation in the medical field is still in the initial stage,and the development is not balanced at home and abroad.The number of articles published and the cooperation between authors and institutions in China obviously lags behind those abroad.Treatment and care of emergency critical patients,emergency event handling and skill training,identification of latent safety threats,improvement of readiness,and promotion of medical quality improvement are the future research hotspots and research trends in this field.
Bibliometrics
;
Humans
;
China
;
Simulation Training
;
Education, Medical
;
Emergency Medicine/education*
7.Clinical study of intracranial hypotension targeted body posture combined with pharmacotherapy in the treatment of chronic subdural hematoma
Jiayu CHEN ; Zhe WANG ; Di ZANG ; Ruizhe ZHENG ; Xiangru YE ; Zengxin QI ; Zeyu XU ; Zhiqiang LI ; Chengfeng SUN ; Liangjun SHEN ; Luoping SHENG ; Fulin XU ; Ruyong YE ; Kaiyu ZHOU ; Weijun TANG ; Yueqing HU ; Dapeng SHI ; Yuquan WANG ; Xizhen WU ; Ying WANG ; Qilin ZHANG ; Feili LIU ; Guo YU ; Yiping LU ; Yirui SUN ; Ning ZHANG ; Feng HUANG ; Xialong GU ; Han ZHANG ; Jian DING ; Yongyan BI ; Haolan DU ; Jing ZHANG ; Hailong JI ; Ding DING ; Wei ZHANG ; Xuehai WU
Chinese Journal of Surgery 2025;63(3):212-218
Objective:To compare the efficacy of body posture combined with pharmacotherapy and pharmacotherapy alone in the treatment of chronic subdural hematoma(CSDH).Methods:Firstly, retrospective case series study was conducted. Thirty cases of CSDH that had received body posture combined with pharmacotherapy at Department of Neurosurgery, Huashan Hospital Affiliated to Fudan University from December 2016 to October 2020 were studied retrospectively. Twenty-seven patients were male, and 3 patients were female. The age of patients ( M(IQR)) was 66(16) years (range:28 to 84). Nineteen patients had unilateral hematoma, and 11 patients had bilateral hematoma. All patients received pharmacotherapy and body posture therapy that was to raise their lower limbs 20 to 30 cm with leg lift pad and get abdominal compressed with customized abdominal belt in supine position. Patients were required to maintain the body posture as much as possible, with the maximum to 16 to 18 hours per day. Patients with unilateral hematoma should tilt the head to the affected side and avoid tilting it to the opposite side. For patients with bilateral hematoma, there was no need for head lateralization. Patient were treated with oral dexamethasone and atorvastatin simultaneously. The preliminary efficacy of body posture combined with pharmacotherapy was determined by hematoma improvement rate which was analyzed by Clopper-Pearson method. Then, the multi-center, prospective, randomized controlled trial had carried out in 9 medical centers from August 2020 to November 2021. The stratified block randomization method was adopted. Patients were randomized in a ratio of 1∶1 to either receive pharmacotherapy alone(the control group) or body posture combined with pharmacotherapy(the experiment group) for 3 months and followed up for 6 months. Effective treatment was defined as complete absorption of hematoma, or the hematoma volume decreased by more than 10 ml and Markwalder grading scale score had improved by more than 1 point compared to the baseline. The efficacy rate and surgery conversion rate at 3 months and recurrence at 6 months were observed. Comparison between groups was performed with paired sample t test, Mann-Whitney U test, χ2 test, corrected χ2 test, or Fisher exact probability method. Logistic regression was used to compare the effective rate and operation rate between the two groups. Results:In the respective study, 30 patients completed follow-up 13 to 353 days after treatment. At the last follow-up, the incidence of almost complete absorption or significantly absorption of hematoma (hematoma volume was significantly reduced accompanied by symptom improvement) was 93.3%. The 95% CI for the incidence that analyzed by the Clopper-Pearson method was 77.9% to 99.2%. One hundred and six patients were enrolled in the multicenter study. Fifty-five patients underwent body posture combined with pharmacotherapy. The age was 74(17) years (range:26 to 92). Thirty-nine patients were males and 16 were females. Fifty-one patients underwent pharmacotherapy alone. The age was 69(12) years (range:48 to 84). Thirty-seven patients were males and 14 were females. The length of body posture recorded in diary card was (15.7±2.3) hours(range:7.6 to 19.3 hours). The efficacy rate in the body posture combined with pharmacotherapy group and pharmacotherapy alone group were 83.6% (46/55) and 56.9% (29/51), respectively at 3 months. The result of the logistic regression analysis showed that the efficacy of body posture combined with pharmacotherapy group was better than that of pharmacotherapy alone group ( OR=3.88,95% CI:1.57 to 9.58, P=0.003). Surgery rate in the body posture combined with pharmacotherapy group and pharmacotherapy alone group were 5.5% (3/55) and 21.6% (11/51) respectively. The result of Logistic regression showed that the pharmacotherapy alone group was more likely to be converted to surgery ( OR=0.21,95% CI:0.05 to 0.80, P=0.023). At the 6 months, no recurrence of cases was found in the body posture combined with pharmacotherapy group. However, the recurrence rate of pharmacotherapy alone group was 6.3% (3/48), there was no significant difference between the two groups ( P>0.05). Conclusion:The effect of body posture combined with pharmacotherapy for chronic subdural hematoma is better than that of pharmacotherapy alone.
8.Quality inspection of ultrasound soft tissue cutting hemostatic equipment
Jing HUANG ; Qi-di SUN ; Ao-wen DUAN ; Li XU ; Heng-yu LONG ; Hai-jiang ZHU ; He-hua ZHANG
Chinese Medical Equipment Journal 2025;46(10):49-53
Objective To carry out quality inspection of the ultrasound soft tissue cutting hemostatic equipment to ensure its safety and effectiveness.Methods Five brands of ultrasound soft tissue cutting hemostatic equipment were selected and noted as test equipment A,test equipment B,test equipment C,test equipment D and test equipment E,which underwent quality inspection in terms of tip main amplitude,tip lateral amplitude,tip vibration frequency,excitation frequency,static electrical power and contact current based on YY/T 0644-2008 Ultrasonics-surgical systems—Measurement and declaration of the basic output characteristics,YY/T 1750-2020 Ultrasonic surgical equipmetn for soft tissue excision and hemostasia and GB 9706.1-2020 Medical electrical equipment—Part 1:General requirements for basic safety and essential performance.Results The test data of the five brands in terms of tip main amplitude,tip lateral amplitude,tip vibration frequency,excitation frequency,static electrical power and contact current met the technical requirements of YY/T 0644-2008,YY/T 1750-2020,GB 9706.1-2020.Conclusion The quality inspection of the ultrasound soft tissue cutting hemostatic equipment contributes to enhancing the accuracy and stability of the equipment and decreasing the risk during its clinical application.[Chinese Medical Equipment Journal,2025,46(10):49-53]
9.Quality inspection of ultrasound soft tissue cutting hemostatic equipment
Jing HUANG ; Qi-di SUN ; Ao-wen DUAN ; Li XU ; Heng-yu LONG ; Hai-jiang ZHU ; He-hua ZHANG
Chinese Medical Equipment Journal 2025;46(10):49-53
Objective To carry out quality inspection of the ultrasound soft tissue cutting hemostatic equipment to ensure its safety and effectiveness.Methods Five brands of ultrasound soft tissue cutting hemostatic equipment were selected and noted as test equipment A,test equipment B,test equipment C,test equipment D and test equipment E,which underwent quality inspection in terms of tip main amplitude,tip lateral amplitude,tip vibration frequency,excitation frequency,static electrical power and contact current based on YY/T 0644-2008 Ultrasonics-surgical systems—Measurement and declaration of the basic output characteristics,YY/T 1750-2020 Ultrasonic surgical equipmetn for soft tissue excision and hemostasia and GB 9706.1-2020 Medical electrical equipment—Part 1:General requirements for basic safety and essential performance.Results The test data of the five brands in terms of tip main amplitude,tip lateral amplitude,tip vibration frequency,excitation frequency,static electrical power and contact current met the technical requirements of YY/T 0644-2008,YY/T 1750-2020,GB 9706.1-2020.Conclusion The quality inspection of the ultrasound soft tissue cutting hemostatic equipment contributes to enhancing the accuracy and stability of the equipment and decreasing the risk during its clinical application.[Chinese Medical Equipment Journal,2025,46(10):49-53]
10.Application of the Anderson sampler in the inspection for the filtration efficiency for bacteria in medical mask
Di LEI ; Chen WANG ; Minjuan ZHANG ; Cunlin LONG ; Jian REN ; Zhijie ZHAO ; Yuwei LI ; Yun LING ; Xiaoning SUN ; Jing ZHAO
China Medical Equipment 2025;22(3):160-163
The medical mask,which is used as an important tool of preventing the spread of respiratory diseases,can effectively block the transmission of biological aerosols.The detection for the filtration efficiency of bacteria in medical mask is particular importance.The Andersen sampler,is one kind of device that samples microbial aerosols,is widely used in the inspection for the filtration efficiency for bacteria in medical masks.It mainly consists of six impactors with different pore sizes.It simulates the deposition process of the most of particles at different positions in respiratory system through the bacterial particles in biological aerosols impact respectively the surface of petri dishes with agar under different pore sizes.This paper explored the development background,structure and sampling principle,operation and counting procedures of the Andersen sampler,as well as its application and importance in the inspection for the filtration efficiency for bacteria in medical mask.

Result Analysis
Print
Save
E-mail