1.From Golgi Stress to Golgiphagy—a New Regulatory Model Involved in Glucose and Lipid Metabolism
Hai-Jun WEI ; He-Ming WANG ; Shu-Jing CHEN ; Shu-Zhi WANG ; Lin-Xi CHEN
Progress in Biochemistry and Biophysics 2026;53(2):275-292
The Golgi body, a core organelle in eukaryotic cells, plays a critical role in protein modification, sorting, vesicular transport, and serves as a key site for lipid synthesis and glycosylation. Glucose and lipid metabolism are central processes for cellular energy maintenance and biosynthesis, and are closely linked to Golgi function. Recent studies have revealed the extensive involvement of the Golgi body in regulating glucose and lipid metabolism, where maintaining its structural and functional homeostasis is crucial for normal physiological activity. Under various stress conditions such as acidosis, hypoxia, and nutrient deficiency, the Golgi body undergoes structural and functional disruption, leading to Golgi stress. This in turn activates specific signaling pathways, such as those mediated by the cAMP-responsive element binding protein 3 (CREB3) and proteoglycans, to alleviate Golgi stress and enhance Golgi function. Golgi stress contributes to glucose and lipid metabolic disorders by affecting the activity of insulin receptors, glucose transporters, and lipid metabolism-related enzymes. For example, Golgi stress triggers the cleavage and release of the active fragment of CREB3, which enters the nucleus and upregulates the transcription of ADP-ribosylation factor 4 (ARF4) and key gluconeogenic enzymes, including phosphoenolpyruvate carboxykinase (PEPCK) and glucose-6-phosphatase (G6Pase). ARF4 promotes vesicle retrograde transport between the Golgi and endoplasmic reticulum, maintains secretory capacity, and enhances hepatic glucose output. This pathway is particularly active under high-fat or lipotoxic stress, leading to fasting hyperglycemia. When damaged Golgi components accumulate beyond a tolerable threshold, the cell initiates an autophagic response, selectively encapsulating the damaged Golgi into autophagosomes, which then fuse with lysosomes to form autolysosomes, leading to Golgiphagy. This process results in the degradation and clearance of damaged Golgi, thereby regulating Golgi quantity, quality, and function. Golgiphagy also plays a significant role in regulating glucose and lipid metabolism. For instance, under high-glucose conditions, autophagic flux may be suppressed, impairing the timely clearance and renewal of damaged Golgi, compromising its normal function, and further exacerbating glucose metabolism disorders. Additionally, Golgiphagy may participate in lipid degradation and influence lipid synthesis and transport. Research indicates that Golgi stress and Golgiphagy play important roles in glucose and lipid metabolism-related diseases. For example, the leucine zipper protein (LZIP) under Golgi stress conditions can promote hepatic steatosis. In mouse primary cells and human tissues, LZIP induces the expression of apolipoprotein A-IV (APOA4), which increases peripheral free fatty acid uptake, resulting in lipid accumulation in the liver and contributing to the development of fatty liver disease. This review systematically outlines the structure and function of the Golgi apparatus, the molecular regulatory mechanisms of Golgi stress and Golgiphagy, and their synergistic roles. It further elaborates on how Golgi stress and Golgiphagy participate in the regulation of glucose and lipid metabolism, discusses their clinical significance in related diseases such as diabetes, fatty liver disease, and obesity, and highlights potential novel therapeutic strategies from the perspective of Golgi-targeted medicine
2.From Golgi Stress to Golgiphagy—a New Regulatory Model Involved in Glucose and Lipid Metabolism
Hai-Jun WEI ; He-Ming WANG ; Shu-Jing CHEN ; Shu-Zhi WANG ; Lin-Xi CHEN
Progress in Biochemistry and Biophysics 2026;53(2):275-292
The Golgi body, a core organelle in eukaryotic cells, plays a critical role in protein modification, sorting, vesicular transport, and serves as a key site for lipid synthesis and glycosylation. Glucose and lipid metabolism are central processes for cellular energy maintenance and biosynthesis, and are closely linked to Golgi function. Recent studies have revealed the extensive involvement of the Golgi body in regulating glucose and lipid metabolism, where maintaining its structural and functional homeostasis is crucial for normal physiological activity. Under various stress conditions such as acidosis, hypoxia, and nutrient deficiency, the Golgi body undergoes structural and functional disruption, leading to Golgi stress. This in turn activates specific signaling pathways, such as those mediated by the cAMP-responsive element binding protein 3 (CREB3) and proteoglycans, to alleviate Golgi stress and enhance Golgi function. Golgi stress contributes to glucose and lipid metabolic disorders by affecting the activity of insulin receptors, glucose transporters, and lipid metabolism-related enzymes. For example, Golgi stress triggers the cleavage and release of the active fragment of CREB3, which enters the nucleus and upregulates the transcription of ADP-ribosylation factor 4 (ARF4) and key gluconeogenic enzymes, including phosphoenolpyruvate carboxykinase (PEPCK) and glucose-6-phosphatase (G6Pase). ARF4 promotes vesicle retrograde transport between the Golgi and endoplasmic reticulum, maintains secretory capacity, and enhances hepatic glucose output. This pathway is particularly active under high-fat or lipotoxic stress, leading to fasting hyperglycemia. When damaged Golgi components accumulate beyond a tolerable threshold, the cell initiates an autophagic response, selectively encapsulating the damaged Golgi into autophagosomes, which then fuse with lysosomes to form autolysosomes, leading to Golgiphagy. This process results in the degradation and clearance of damaged Golgi, thereby regulating Golgi quantity, quality, and function. Golgiphagy also plays a significant role in regulating glucose and lipid metabolism. For instance, under high-glucose conditions, autophagic flux may be suppressed, impairing the timely clearance and renewal of damaged Golgi, compromising its normal function, and further exacerbating glucose metabolism disorders. Additionally, Golgiphagy may participate in lipid degradation and influence lipid synthesis and transport. Research indicates that Golgi stress and Golgiphagy play important roles in glucose and lipid metabolism-related diseases. For example, the leucine zipper protein (LZIP) under Golgi stress conditions can promote hepatic steatosis. In mouse primary cells and human tissues, LZIP induces the expression of apolipoprotein A-IV (APOA4), which increases peripheral free fatty acid uptake, resulting in lipid accumulation in the liver and contributing to the development of fatty liver disease. This review systematically outlines the structure and function of the Golgi apparatus, the molecular regulatory mechanisms of Golgi stress and Golgiphagy, and their synergistic roles. It further elaborates on how Golgi stress and Golgiphagy participate in the regulation of glucose and lipid metabolism, discusses their clinical significance in related diseases such as diabetes, fatty liver disease, and obesity, and highlights potential novel therapeutic strategies from the perspective of Golgi-targeted medicine
3.Biomechanical mechanism of sports-related patellar tendinitis
Caihong ZHONG ; Xiaoge XIAO ; Ming LI ; Jianhong LIN ; Jing HONG
Chinese Journal of Tissue Engineering Research 2026;30(6):1417-1423
BACKGROUND:Patellar tendonitis can present as tendon degeneration that fails to heal due to tissue overload and incomplete recovery.Patellar tendonitis is a predisposition to high jumping and its pathogenesis has not been clearly defined.OBJECTIVE:To explore the stress-strain relationship of patellar tendon in the take-off technique of high jump through the finite element model with accurate human anatomical structure,so as to provide ideas for the prevention and rehabilitation of patellar tendinitis.METHODS:Based on the CT and MRI imaging data of the lower extremity(including the knee and ankle)of one subject(22 years old,183 cm height,70 kg body mass),a three-dimensional finite element model of the lower extremity was reconstructed using medical imaging software,reverse engineering software and modeling software.The plantar pressure of the take-off leg was collected in eight subjects by gait testing system,and the technical action of high jump take-off was collected by motion capture system.The captured data were imported into human sports biomechanics software for analysis,and kinematic and kinetic data were obtained as the boundary conditions of finite element model for finite element simulation analysis.RESULTS AND CONCLUSION:The force borne by the patellar tendon reached 3.29 times of its own body mass when the subjects took off.In the take-off stage,the peak values of normal equivalent stress,strain and shear stress of the patellar tendon were 127.76 MPa,0.81 and 37.69 MPa,respectively,which were in the nonlinear region of the stress-strain curve,and the peak values were distributed in the proximal and posterior parts of patellar tendon.To conclude,the high patellar tendon force,strain and shear stress caused by the load of 3.29 times its own body mass during take-off are related to the induction of patellar tendinitis.
4.Biomechanical mechanism of sports-related patellar tendinitis
Caihong ZHONG ; Xiaoge XIAO ; Ming LI ; Jianhong LIN ; Jing HONG
Chinese Journal of Tissue Engineering Research 2026;30(6):1417-1423
BACKGROUND:Patellar tendonitis can present as tendon degeneration that fails to heal due to tissue overload and incomplete recovery.Patellar tendonitis is a predisposition to high jumping and its pathogenesis has not been clearly defined.OBJECTIVE:To explore the stress-strain relationship of patellar tendon in the take-off technique of high jump through the finite element model with accurate human anatomical structure,so as to provide ideas for the prevention and rehabilitation of patellar tendinitis.METHODS:Based on the CT and MRI imaging data of the lower extremity(including the knee and ankle)of one subject(22 years old,183 cm height,70 kg body mass),a three-dimensional finite element model of the lower extremity was reconstructed using medical imaging software,reverse engineering software and modeling software.The plantar pressure of the take-off leg was collected in eight subjects by gait testing system,and the technical action of high jump take-off was collected by motion capture system.The captured data were imported into human sports biomechanics software for analysis,and kinematic and kinetic data were obtained as the boundary conditions of finite element model for finite element simulation analysis.RESULTS AND CONCLUSION:The force borne by the patellar tendon reached 3.29 times of its own body mass when the subjects took off.In the take-off stage,the peak values of normal equivalent stress,strain and shear stress of the patellar tendon were 127.76 MPa,0.81 and 37.69 MPa,respectively,which were in the nonlinear region of the stress-strain curve,and the peak values were distributed in the proximal and posterior parts of patellar tendon.To conclude,the high patellar tendon force,strain and shear stress caused by the load of 3.29 times its own body mass during take-off are related to the induction of patellar tendinitis.
5.Expert consensus on management of instrument separation in root canal therapy.
Yi FAN ; Yuan GAO ; Xiangzhu WANG ; Bing FAN ; Zhi CHEN ; Qing YU ; Ming XUE ; Xiaoyan WANG ; Zhengwei HUANG ; Deqin YANG ; Zhengmei LIN ; Yihuai PAN ; Jin ZHAO ; Jinhua YU ; Zhuo CHEN ; Sijing XIE ; He YUAN ; Kehua QUE ; Shuang PAN ; Xiaojing HUANG ; Jun LUO ; Xiuping MENG ; Jin ZHANG ; Yi DU ; Lei ZHANG ; Hong LI ; Wenxia CHEN ; Jiayuan WU ; Xin XU ; Jing ZOU ; Jiyao LI ; Dingming HUANG ; Lei CHENG ; Tiemei WANG ; Benxiang HOU ; Xuedong ZHOU
International Journal of Oral Science 2025;17(1):46-46
Instrument separation is a critical complication during root canal therapy, impacting treatment success and long-term tooth preservation. The etiology of instrument separation is multifactorial, involving the intricate anatomy of the root canal system, instrument-related factors, and instrumentation techniques. Instrument separation can hinder thorough cleaning, shaping, and obturation of the root canal, posing challenges to successful treatment outcomes. Although retrieval of separated instrument is often feasible, it carries risks including perforation, excessive removal of tooth structure and root fractures. Effective management of separated instruments requires a comprehensive understanding of the contributing factors, meticulous preoperative assessment, and precise evaluation of the retrieval difficulty. The application of appropriate retrieval techniques is essential to minimize complications and optimize clinical outcomes. The current manuscript provides a framework for understanding the causes, risk factors, and clinical management principles of instrument separation. By integrating effective strategies, endodontists can enhance decision-making, improve endodontic treatment success and ensure the preservation of natural dentition.
Humans
;
Root Canal Therapy/adverse effects*
;
Consensus
;
Root Canal Preparation/adverse effects*
6.Expert consensus on digital restoration of complete dentures.
Yue FENG ; Zhihong FENG ; Jing LI ; Jihua CHEN ; Haiyang YU ; Xinquan JIANG ; Yongsheng ZHOU ; Yumei ZHANG ; Cui HUANG ; Baiping FU ; Yan WANG ; Hui CHENG ; Jianfeng MA ; Qingsong JIANG ; Hongbing LIAO ; Chufan MA ; Weicai LIU ; Guofeng WU ; Sheng YANG ; Zhe WU ; Shizhu BAI ; Ming FANG ; Yan DONG ; Jiang WU ; Lin NIU ; Ling ZHANG ; Fu WANG ; Lina NIU
International Journal of Oral Science 2025;17(1):58-58
Digital technologies have become an integral part of complete denture restoration. With advancement in computer-aided design and computer-aided manufacturing (CAD/CAM), tools such as intraoral scanning, facial scanning, 3D printing, and numerical control machining are reshaping the workflow of complete denture restoration. Unlike conventional methods that rely heavily on clinical experience and manual techniques, digital technologies offer greater precision, predictability, and efficacy. They also streamline the process by reducing the number of patient visits and improving overall comfort. Despite these improvements, the clinical application of digital complete denture restoration still faces challenges that require further standardization. The major issues include appropriate case selection, establishing consistent digital workflows, and evaluating long-term outcomes. To address these challenges and provide clinical guidance for practitioners, this expert consensus outlines the principles, advantages, and limitations of digital complete denture technology. The aim of this review was to offer practical recommendations on indications, clinical procedures and precautions, evaluation metrics, and outcome assessment to support digital restoration of complete denture in clinical practice.
Humans
;
Denture, Complete
;
Computer-Aided Design
;
Denture Design/methods*
;
Consensus
;
Printing, Three-Dimensional
7.Comparison of short-term clinical efficacy between CO external fixation and internal fixation with steel plate in the treatment of unstable distal radius fractures.
Min-Rui FU ; Chang-Long SHI ; Yong-Zhong CHENG ; Ming-Ming MA ; Zheng-Lin NIU ; Hai-Xiang SUN ; Jing-Hua GAO ; Zhong-Kai WU ; Yi-Ming XU
China Journal of Orthopaedics and Traumatology 2025;38(1):10-17
OBJECTIVE:
To evaluate the short-term clinical efficacy of external fixation and internal fixation with steel plate in the treatment of unstable distal radius fractures (AO-23C type), based on the principles of Chinese osteosynthesis (CO).
METHODS:
Forty-eight patients with unstable distal radius fractures between January 2022 and February 2023 were retrospectively analyzed and divided into the CO external fixation group and internal fixation group. CO external fixation group consisted of 25 patients, including 7 males and 18 females, aged from 37 to 56 years old with an average of ( 52.6±11.3) years old. Among them, there were 7 patients of traffic accidents and 18 patients of falls, resulting in a total of 25 patients of closed fractures and no open fractures, the treatment was conducted using closed reduction and CO external fixation. The internal fixation group consisted of 23 patients, comprising 8 males and 15 females, age ranged from 41 to 59 years old, with an average age of(53.3±13.7) years old. Among them, 8 patients resulted from car accidents while the remaining 15 patients were caused by falls. All 23 patients were closed fractures without any open fractures observed. The technique of open reduction and internal fixation with steel plate was employed. The perioperative data, including injury-operation time, operation duration, blood loss, and length of hospital stay, were assessed in both groups. Additionally, the QuickDASH score and visual analogue scale (VAS) were evaluated. Range of motion and grip strength assessment, imaging findings such as palmar inclination angle, ulnar declination angle, radius length, articular surface step, intra-articular space measurements were also examined along with any complications.
RESULTS:
The follow-up duration ranged from 0 to 24 months, with an average duration of (16.0±3.8) months. The CO external fixation exhibited significantly shorter time from injury to operation (2.4±3.3) d vs (7.4±3.7) d, shorter operation duration (56.27±15.23) min vs (74.10±5.26) min, lower blood loss (14.52±6.54) ml vs (32.32±10.03) ml, and reduced hospitalization days (14.04±3.24 )d vs (16.45±3.05) d compared to the internal fixation group (P<0.05). The QuickDASH score at 12 months post-operation was (8.21±1.64) in the CO external fixation group, while no significant difference was observed in the internal fixation group (7.04±3.64), P>0.05. There were no statistically significant differences in VAS between two groups at 6 weeks, as well as 1 and 3 months post-surgery (P>0.05). Additionally, there were no significant disparities observed in terms of range of motion and grip strength between two groups at the 2-year follow-up after the operation (P>0.05). After 12 months of surgery, the CO external fixation group exhibited a significantly smaller palmar inclination angle (17.90±2.18) ° vs (19.87±3.21) °, reduced articular surface step (0.11±0.03) mm vs (0.17±0.02) mm, and shorter radius length (8.16±1.11) mm compared to the internal fixation group (9.59±1.02) mm, P<0.05. The ulnar deviation angle and intra-articular space did not show any significant difference between two groups (P>0.05). The reduced fell within the allowable range between the CO external fixation group (23 out of 25 cases) and the internal fixation group (21 out of 23 cases) was not statistically significant (P=0.29). There was no significant difference in complications between the two groups(P>0.05).
CONCLUSION
Both the CO external fixation and open reduction with plate internal fixation demonstrate clinical efficacy in managing unstable distal radius fractures. The CO external fixation offers advantages in shorter injury-to-operation times, reduced intraoperative blood loss, and decreased surgical durations, while radial shortening is more effectively controlled by internal fixation.
Humans
;
Male
;
Female
;
Middle Aged
;
Radius Fractures/physiopathology*
;
Adult
;
Bone Plates
;
Fracture Fixation, Internal/methods*
;
External Fixators
;
Retrospective Studies
;
Fracture Fixation/methods*
;
Wrist Fractures
8.Dorsally displaced distal radial double-column Die-punch fractures by dorsal approach external fixator combined with Kirschner wires.
Fu-de JIAO ; Jing-Wei ZHANG ; Li-Mei ZHU ; Lin AN ; Yun-Qiang ZHUANG ; Jian-Ming CHEN
China Journal of Orthopaedics and Traumatology 2025;38(1):87-91
OBJECTIVE:
Investigating the clinical efficacy of treating dorsally displaced distal radial double-column Die-punch fractures using a dorsal approach external fixator combined with Kirschner wires.
METHODS:
Retrospectively analyzed the clinical data of 15 patients with distal radial double-column Die-punch fractures treated with an external fixator combined with Kirschner wire between July 2020 and January 2023. There were 10 males and 5 females;6 cases on the left side and 9 on the right;age ranged from 22 to 76 years old. Recorded the preoperative and the final follow-up Cooney wrist function scores for the patients. The fracture healing time, and occurrence of complications were recorded.
RESULTS:
All 15 patients were followed up ranged from 12 to 16 months post-operation. All fractures achieved bony union, healing time ranging form 8 to 16 weeks. Not a single patient exhibited complications such as surgical site infection, fracture redislocation, or tendon injury. All individuals had their Kirschner wires and external fixation devices removed six weeks post-operatively and commenced rehabilitative therapy for wrist articulation. The Cooney wrist function scores at preoperative and ranged from 5 to 45 scores, at the latest follow-up ranged from 65 to 100 scores. At the final follow-up, the results were assessed as excellent in 10 patients, good in 4 patients, and fair in 1 patient.
CONCLUSION
The clinical efficacy of treating distal radial double-column Die-punch fractures using a dorsal approach external fixator combined with Kirschner wires is satisfactory.
Humans
;
Male
;
Female
;
Middle Aged
;
Adult
;
External Fixators
;
Bone Wires
;
Aged
;
Retrospective Studies
;
Radius Fractures/physiopathology*
;
Young Adult
;
Fracture Fixation/methods*
9.Preliminary efficacy observation of 3D printed functional spinal external fixation brace combined with McKenzie therapy in the treatment of lumbar disc herniation.
Ning-Xia WANG ; Ping CHEN ; Hai-Dong WANG ; Jing JI ; Fang-Hong NIAN ; Xin LIU ; Chong-Fei JIN ; Duo-Ming ZHAO ; Hao-Lin LI ; Wei-Gang CHENG ; Gui-Lin LAI ; Guo-Biao WU
China Journal of Orthopaedics and Traumatology 2025;38(10):1047-1054
OBJECTIVE:
To observe the clinical efficacy of 3D printing spinal external fixator combined with McKenzie therapy for patients with lumbar dics herniation (LDH).
METHODS:
Sixty patients with LDH between January 2022 and January 2023 were enrolled. Among them, 30 patients were given McKinsey training. According to different treatment methods, all patients were divided into McKenzie group and McKenzie + 3D printing group, 30 patients in each group. The McKenzie group provided McKenzie therapy. The McKenzie + 3D printing group were treated with 3D printing spinal external fixation brace on the basis of McKenzie therapy. Patients in both groups were between 25 and 60 years of age and had their first illness. In the McKenzie group, there were 19 males and 11 females, with an average age of (48.57±5.86) years old, and the disease duration was (7.03 ±2.39) months. The McKenzie + 3D printing group, there were 21 males and 9 females, with an average age of (48.80±5.92) years old, and the disease duration was(7.30±2.56) months. Pain was evaluated using the visual analogue scale (VAS), and lumbar spine function was assessed using the Oswestry disability index (ODI) and the Japanese Orthopaedic Association (JOA) score. VAS, ODI and JOA scores were compared between two groups before treatment and at 1, 3, 6, 9 and 12 months after treatment.
RESULTS:
All patients were followed up for 12 months. The VAS for the McKenzie combined with 3D printing group before treatment and at 1, 3, 6, 9, and 12 months post-treatment were(6.533±0.860), (5.133±1.008), (3.933±0.868), (2.900±0.759), (2.067±0.640), (1.433±0.504), respectively. In the McKenzie group, the corresponding scores were (6.467±0.860), (5.067±1.048), (4.600±0.968), (3.533±1.008), (2.567±0.728), (1.967±0.809), respectively. The ODI of the McKenzie group before treatment and at 1, 3, 6, 9, and 12 months post-treatment were (41.033±6.810)%, (37.933±6.209)%, (35.467±6.962)%, (27.567±10.081)%, (20.800±7.531)%, (13.533±5.158)%, respectively. For the McKenzie combined with 3D printing group, the corresponding ODI were(38.033±5.605)%, (33.000±6.192)%, (28.767±7.045)%, (22.200±5.517)%, (17.700±4.836)%, (11.900±2.771)%, respectively. The JOA scores of the McKenzie combined with 3D printing group before treatment and at 1, 3, 6, 9, and 12 months post-treatment were(8.900±2.074), (13.133±2.330), (15.700±3.583), (20.400±3.480), (22.267±3.084), (24.833±2.640), respectively. In the McKenzie group, the corresponding scores were(9.200±2.091), (12.267±2.406), (15.333±3.198), (18.467±2.240), (20.133±2.751), (22.467±2.849), respectively. Before the initiation of treatment, no statistically significant differences were observed in the VAS, ODI, and JOA scores between two groups (P>0.05). At 3, 6, 9, and 12 months post-treatment, the VAS in the McKenzie combined with 3D printing group was significantly lower than that in the McKenzie group, and the difference was statistically significant (P<0.05). The comparison of ODI between two groups at 1, 3, 6, 9, and 12 months post-treatment revealed statistically significant differences (P<0.05). At 6, 9, and 12 months post-treatment, the JOA score in the McKenzie combined with 3D printing group was significantly higher than that in the McKenzie-only group, and the difference was statistically significant (P<0.05).
CONCLUSION
The combination of 3D printed functional spinal external fixation brace with McKenzie therapy can significantly improve and maintain lumbar function in patients with LDH.
Humans
;
Male
;
Female
;
Middle Aged
;
Printing, Three-Dimensional
;
Intervertebral Disc Displacement/surgery*
;
External Fixators
;
Lumbar Vertebrae/surgery*
;
Adult
;
Braces
;
Treatment Outcome
10.Research of injury mapping relationship of lumbar spine in reclined occupants between anthropomorphic test devices and human body model.
Yu LIU ; Jing FEI ; Xin-Ming WAN ; Pei-Feng WANG ; Zhen LI ; Xiao-Ting YANG ; Lin-Wei ZHANG ; Zhong-Hao BAI
Chinese Journal of Traumatology 2025;28(2):130-137
PURPOSE:
To judge the injury mode and injury severity of the real human body through the measured values of anthropomorphic test devices (ATD) injury indices, the mapping relationship of lumbar injury between ATD and human body model (HBM) was explored.
METHODS:
Through the ATD model and HBM simulation, the mapping relationship of lumbar injury between the 2 subjects was explored. The sled environment consisted of a semi-rigid seat with an adjustable seatback angle and a 3-point seat belt system with a seatback-mounted D-ring. Three seatback recline states of 25°, 45°, and 65° were designed, and the seat pan angle was maintained at 15°. A 23 g, 47 km/h pulse was used. The validity of the finite element model of the sled was verified by the comparison of ATD simulation and test results. ATD model was the test device for human occupant restraint for autonomous vehicles (THOR-AV) dummy model and HBM was the total human model for safety (THUMS) v6.1. The posture of the 2 models was adjusted to adapt to the 3 seat states. The lumbar response of THOR-AV and the mechanical and biomechanical data on L1 - L5 vertebrae of THUMS were output, and the response relationship between THOR-AV and THUMS was descriptive statistically analyzed.
RESULTS:
Both THOR-AV and THUMS were submarined in the 65° seatback angle case. With the change of seatback angle, the lumbar spine axial compression force (Fz) of THOR-AV and THUMS changed in the similar trend. The maximum Fz ratio of THOR-AV to THUMS at 25° and 45° seatback angle cases were 1.6 and 1.7. The flexion moment (My) and the time when the maximum My occurred in the 2 subjects were very different. In particular, the form of moment experienced by the L1 - L5 vertebrae of THUMS also changed. The changing trend of My measured by THOR-AV over time can reflect the changing trend of maximum stress of L1 and L2 of THUMS.
CONCLUSION
The Fz of ATD and HBM presents a certain proportional relationship, and there is a mapping relationship between the 2 subjects on Fz. The mapping function can be further clarified by applying more pulses and adopting more seatback angles. It is difficult to map My directly because they are very different in ATD and HBM. The My of ATD and stress of HBM lumbar showed a similar change trend over time, and there may be a hidden mapping relationship.
Humans
;
Lumbar Vertebrae/injuries*
;
Finite Element Analysis
;
Biomechanical Phenomena
;
Manikins
;
Spinal Injuries/physiopathology*

Result Analysis
Print
Save
E-mail