1.Mechanisms of Bushen Tongluo Jiangzhuo Prescription in Improving Renal Fibrosis in Rats with Chronic Kidney Disease Based on PI3K/Akt/mTOR Signaling Pathway
Xincui BAO ; Baosheng ZHAO ; Lingling QIN ; Haiyan WANG ; Jing YANG ; You WANG ; Lijia WU ; Yujin LI ; Ming GAO ; Cuiyan LYU ; Tonghua LIU
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(6):100-108
ObjectiveTo investigate the mechanisms by which Bushen Tongluo Jiangzhuo prescription improves renal fibrosis in rats with chronic kidney disease (CKD) through the phosphatidylinositol 3-kinase (PI3K)/protein kinase B (Akt)/mammalian target of rapamycin (mTOR) signaling pathway. MethodsSeventy specific pathogen-free (SPF) Sprague-Dawley (SD) rats were randomly divided into a control group (n=15) and a modeling group (n=55). Rats in the modeling group were administered a 2.5% adenine suspension at a dose of 200 mg·kg-1·d-1 by gavage for 4 weeks to establish a CKD model. Successfully modeled rats were randomly divided into a model group, an irbesartan group (20.25 mg·kg-1·d-1), and Bushen Tongluo Jiangzhuo prescription low-, medium-, and high-dose groups (5.82, 11.64, and 23.28 g·kg-1·d-1, respectively), with 10 rats in each group. Each group was administered an equal volume of physiological saline, the corresponding concentration of irbesartan, or Bushen Tongluo Jiangzhuo prescription by gavage for 12 weeks. Body weight and renal function indices were dynamically monitored. Serum creatinine (SCr), blood urea nitrogen (BUN), urine albumin-to-creatinine ratio (ACR), 24-hour urinary total protein (24 hUTP), aspartate aminotransferase (AST), alanine aminotransferase (ALT), interleukin-1β (IL-1β), interleukin-6 (IL-6), and tumor necrosis factor-α (TNF-α) levels were measured using an automatic biochemical analyzer. Renal histopathological changes were observed by hematoxylin-eosin (HE) and Masson staining. Immunohistochemistry (IHC) was used to detect the expression of PI3K, Akt, phosphorylated Akt (p-Akt), and mTOR in renal tissues. Western blot was performed to assess the protein expression of PI3K, p-Akt, Akt, phosphorylated mTOR (p-mTOR), and mTOR in renal tissues. Real-time quantitative polymerase chain reaction (Real-time PCR) was used to determine the mRNA expression levels of PI3K, Akt, and mTOR in renal tissues. ResultsCompared with the model group, rats in the irbesartan group and the low-, medium-, and high-dose Bushen Tongluo Jiangzhuo prescription groups showed significantly decreased levels of SCr, BUN, ACR, 24 hUTP, IL-1β, IL-6, and TNF-α (P<0.01). AST levels were significantly increased (P<0.01), while no significant difference was observed in ALT levels. Histopathological examination revealed that, compared with the model group, renal tubular epithelial cell edema and necrosis and Bowman's capsule dilation were alleviated, inflammatory cell infiltration was reduced, and interstitial and glomerular fibrosis was markedly improved in all treatment groups, with the most pronounced effect observed in the high-dose Bushen Tongluo Jiangzhuo prescription group. Real-time PCR results showed that mRNA expression levels of PI3K, Akt, and mTOR were significantly downregulated in the high-dose group (P<0.01). IHC results demonstrated that PI3K and p-Akt expression levels in renal tissues were significantly decreased in the high-dose group (P<0.01). Western blot analysis further confirmed that the expression levels of PI3K, p-Akt/Akt, and p-mTOR/mTOR were significantly reduced in the high-dose group (P<0.01). ConclusionBushen Tongluo Jiangzhuo prescription improves renal function indices in CKD rats, reduces collagen deposition in renal tissues, and decreases serum inflammatory factor levels. Its protective effect on renal function may be achieved by activating autophagy through downregulation of the PI3K/Akt/mTOR signaling pathway, thereby alleviating renal fibrosis.
2.Biomechanical mechanism of sports-related patellar tendinitis
Caihong ZHONG ; Xiaoge XIAO ; Ming LI ; Jianhong LIN ; Jing HONG
Chinese Journal of Tissue Engineering Research 2026;30(6):1417-1423
BACKGROUND:Patellar tendonitis can present as tendon degeneration that fails to heal due to tissue overload and incomplete recovery.Patellar tendonitis is a predisposition to high jumping and its pathogenesis has not been clearly defined.OBJECTIVE:To explore the stress-strain relationship of patellar tendon in the take-off technique of high jump through the finite element model with accurate human anatomical structure,so as to provide ideas for the prevention and rehabilitation of patellar tendinitis.METHODS:Based on the CT and MRI imaging data of the lower extremity(including the knee and ankle)of one subject(22 years old,183 cm height,70 kg body mass),a three-dimensional finite element model of the lower extremity was reconstructed using medical imaging software,reverse engineering software and modeling software.The plantar pressure of the take-off leg was collected in eight subjects by gait testing system,and the technical action of high jump take-off was collected by motion capture system.The captured data were imported into human sports biomechanics software for analysis,and kinematic and kinetic data were obtained as the boundary conditions of finite element model for finite element simulation analysis.RESULTS AND CONCLUSION:The force borne by the patellar tendon reached 3.29 times of its own body mass when the subjects took off.In the take-off stage,the peak values of normal equivalent stress,strain and shear stress of the patellar tendon were 127.76 MPa,0.81 and 37.69 MPa,respectively,which were in the nonlinear region of the stress-strain curve,and the peak values were distributed in the proximal and posterior parts of patellar tendon.To conclude,the high patellar tendon force,strain and shear stress caused by the load of 3.29 times its own body mass during take-off are related to the induction of patellar tendinitis.
3.Biomechanical mechanism of sports-related patellar tendinitis
Caihong ZHONG ; Xiaoge XIAO ; Ming LI ; Jianhong LIN ; Jing HONG
Chinese Journal of Tissue Engineering Research 2026;30(6):1417-1423
BACKGROUND:Patellar tendonitis can present as tendon degeneration that fails to heal due to tissue overload and incomplete recovery.Patellar tendonitis is a predisposition to high jumping and its pathogenesis has not been clearly defined.OBJECTIVE:To explore the stress-strain relationship of patellar tendon in the take-off technique of high jump through the finite element model with accurate human anatomical structure,so as to provide ideas for the prevention and rehabilitation of patellar tendinitis.METHODS:Based on the CT and MRI imaging data of the lower extremity(including the knee and ankle)of one subject(22 years old,183 cm height,70 kg body mass),a three-dimensional finite element model of the lower extremity was reconstructed using medical imaging software,reverse engineering software and modeling software.The plantar pressure of the take-off leg was collected in eight subjects by gait testing system,and the technical action of high jump take-off was collected by motion capture system.The captured data were imported into human sports biomechanics software for analysis,and kinematic and kinetic data were obtained as the boundary conditions of finite element model for finite element simulation analysis.RESULTS AND CONCLUSION:The force borne by the patellar tendon reached 3.29 times of its own body mass when the subjects took off.In the take-off stage,the peak values of normal equivalent stress,strain and shear stress of the patellar tendon were 127.76 MPa,0.81 and 37.69 MPa,respectively,which were in the nonlinear region of the stress-strain curve,and the peak values were distributed in the proximal and posterior parts of patellar tendon.To conclude,the high patellar tendon force,strain and shear stress caused by the load of 3.29 times its own body mass during take-off are related to the induction of patellar tendinitis.
4.Classification and advances in clinical research of artificial colloidal plasma substitutes
Zhengyang CHANG ; Ming LI ; Jianpeng GAO ; Jing ZHANG ; Hua LYU ; Licheng ZHANG
Chinese Journal of Blood Transfusion 2025;38(1):136-141
The number of patients with reduced blood volume due to haemorrhage, fractures, severe infections, extensive burns and tumours is increasing, and traditional blood products are no longer able to meet the increasing clinical demand. Therefore, plasma substitutes have become particularly important in fluid resuscitation, especially artificial colloidal solutions, which have a sustained volume expansion time and a good volume expansion effect, and can significantly improve the circulatory status of patients. This article aims to review the classification of artificial colloidal plasma substitutes and their research progress in clinical practice, in order provide a more rigorous, professional and standardized reference for medicine.
5.Dorsally displaced distal radial double-column Die-punch fractures by dorsal approach external fixator combined with Kirschner wires.
Fu-de JIAO ; Jing-Wei ZHANG ; Li-Mei ZHU ; Lin AN ; Yun-Qiang ZHUANG ; Jian-Ming CHEN
China Journal of Orthopaedics and Traumatology 2025;38(1):87-91
OBJECTIVE:
Investigating the clinical efficacy of treating dorsally displaced distal radial double-column Die-punch fractures using a dorsal approach external fixator combined with Kirschner wires.
METHODS:
Retrospectively analyzed the clinical data of 15 patients with distal radial double-column Die-punch fractures treated with an external fixator combined with Kirschner wire between July 2020 and January 2023. There were 10 males and 5 females;6 cases on the left side and 9 on the right;age ranged from 22 to 76 years old. Recorded the preoperative and the final follow-up Cooney wrist function scores for the patients. The fracture healing time, and occurrence of complications were recorded.
RESULTS:
All 15 patients were followed up ranged from 12 to 16 months post-operation. All fractures achieved bony union, healing time ranging form 8 to 16 weeks. Not a single patient exhibited complications such as surgical site infection, fracture redislocation, or tendon injury. All individuals had their Kirschner wires and external fixation devices removed six weeks post-operatively and commenced rehabilitative therapy for wrist articulation. The Cooney wrist function scores at preoperative and ranged from 5 to 45 scores, at the latest follow-up ranged from 65 to 100 scores. At the final follow-up, the results were assessed as excellent in 10 patients, good in 4 patients, and fair in 1 patient.
CONCLUSION
The clinical efficacy of treating distal radial double-column Die-punch fractures using a dorsal approach external fixator combined with Kirschner wires is satisfactory.
Humans
;
Male
;
Female
;
Middle Aged
;
Adult
;
External Fixators
;
Bone Wires
;
Aged
;
Retrospective Studies
;
Radius Fractures/physiopathology*
;
Young Adult
;
Fracture Fixation/methods*
6.Preliminary efficacy observation of 3D printed functional spinal external fixation brace combined with McKenzie therapy in the treatment of lumbar disc herniation.
Ning-Xia WANG ; Ping CHEN ; Hai-Dong WANG ; Jing JI ; Fang-Hong NIAN ; Xin LIU ; Chong-Fei JIN ; Duo-Ming ZHAO ; Hao-Lin LI ; Wei-Gang CHENG ; Gui-Lin LAI ; Guo-Biao WU
China Journal of Orthopaedics and Traumatology 2025;38(10):1047-1054
OBJECTIVE:
To observe the clinical efficacy of 3D printing spinal external fixator combined with McKenzie therapy for patients with lumbar dics herniation (LDH).
METHODS:
Sixty patients with LDH between January 2022 and January 2023 were enrolled. Among them, 30 patients were given McKinsey training. According to different treatment methods, all patients were divided into McKenzie group and McKenzie + 3D printing group, 30 patients in each group. The McKenzie group provided McKenzie therapy. The McKenzie + 3D printing group were treated with 3D printing spinal external fixation brace on the basis of McKenzie therapy. Patients in both groups were between 25 and 60 years of age and had their first illness. In the McKenzie group, there were 19 males and 11 females, with an average age of (48.57±5.86) years old, and the disease duration was (7.03 ±2.39) months. The McKenzie + 3D printing group, there were 21 males and 9 females, with an average age of (48.80±5.92) years old, and the disease duration was(7.30±2.56) months. Pain was evaluated using the visual analogue scale (VAS), and lumbar spine function was assessed using the Oswestry disability index (ODI) and the Japanese Orthopaedic Association (JOA) score. VAS, ODI and JOA scores were compared between two groups before treatment and at 1, 3, 6, 9 and 12 months after treatment.
RESULTS:
All patients were followed up for 12 months. The VAS for the McKenzie combined with 3D printing group before treatment and at 1, 3, 6, 9, and 12 months post-treatment were(6.533±0.860), (5.133±1.008), (3.933±0.868), (2.900±0.759), (2.067±0.640), (1.433±0.504), respectively. In the McKenzie group, the corresponding scores were (6.467±0.860), (5.067±1.048), (4.600±0.968), (3.533±1.008), (2.567±0.728), (1.967±0.809), respectively. The ODI of the McKenzie group before treatment and at 1, 3, 6, 9, and 12 months post-treatment were (41.033±6.810)%, (37.933±6.209)%, (35.467±6.962)%, (27.567±10.081)%, (20.800±7.531)%, (13.533±5.158)%, respectively. For the McKenzie combined with 3D printing group, the corresponding ODI were(38.033±5.605)%, (33.000±6.192)%, (28.767±7.045)%, (22.200±5.517)%, (17.700±4.836)%, (11.900±2.771)%, respectively. The JOA scores of the McKenzie combined with 3D printing group before treatment and at 1, 3, 6, 9, and 12 months post-treatment were(8.900±2.074), (13.133±2.330), (15.700±3.583), (20.400±3.480), (22.267±3.084), (24.833±2.640), respectively. In the McKenzie group, the corresponding scores were(9.200±2.091), (12.267±2.406), (15.333±3.198), (18.467±2.240), (20.133±2.751), (22.467±2.849), respectively. Before the initiation of treatment, no statistically significant differences were observed in the VAS, ODI, and JOA scores between two groups (P>0.05). At 3, 6, 9, and 12 months post-treatment, the VAS in the McKenzie combined with 3D printing group was significantly lower than that in the McKenzie group, and the difference was statistically significant (P<0.05). The comparison of ODI between two groups at 1, 3, 6, 9, and 12 months post-treatment revealed statistically significant differences (P<0.05). At 6, 9, and 12 months post-treatment, the JOA score in the McKenzie combined with 3D printing group was significantly higher than that in the McKenzie-only group, and the difference was statistically significant (P<0.05).
CONCLUSION
The combination of 3D printed functional spinal external fixation brace with McKenzie therapy can significantly improve and maintain lumbar function in patients with LDH.
Humans
;
Male
;
Female
;
Middle Aged
;
Printing, Three-Dimensional
;
Intervertebral Disc Displacement/surgery*
;
External Fixators
;
Lumbar Vertebrae/surgery*
;
Adult
;
Braces
;
Treatment Outcome
7.Protocol for development of Guideline for Interventions on Cervical Spine Health.
Jing LI ; Guang-Qi LU ; Ming-Hui ZHUANG ; Xin-Yue SUN ; Ya-Kun LIU ; Ming-Ming MA ; Li-Guo ZHU ; Zhong-Shi LI ; Wei CHEN ; Ji-Ge DONG ; Le-Wei ZHANG ; Jie YU
China Journal of Orthopaedics and Traumatology 2025;38(10):1083-1088
Cervical spine health issues not only seriously affect patients' quality of life but also impose a heavy burden on the social healthcare system. Existing guidelines lack sufficient clinical guidance on lifestyle and work habits, such as exercise, posture, daily routine, and diet, making it difficult to meet practical needs. To address this, relying on the China Association of Chinese Medicine, Wangjing Hospital of China Academy of Chinese Medical Sciences took the lead and joined hands with more than ten institutions to form a multidisciplinary guideline development group. For the first time, the group developed the Guidelines for Cervical Spine Health Intervention based on evidence-based medicine methods, strictly following the standardized procedures outlined in the World Health Organization Handbook for Guideline Development and the Guiding Principles for the Formulation/Revision of Clinical Practice Guidelines in China (2022 Edition). This proposal systematically explains the methods and steps for developing the guideline, aiming to make the guideline development process scientific, standardized, and transparent.
Humans
;
Practice Guidelines as Topic/standards*
;
Cervical Vertebrae
;
China
8.Research of injury mapping relationship of lumbar spine in reclined occupants between anthropomorphic test devices and human body model.
Yu LIU ; Jing FEI ; Xin-Ming WAN ; Pei-Feng WANG ; Zhen LI ; Xiao-Ting YANG ; Lin-Wei ZHANG ; Zhong-Hao BAI
Chinese Journal of Traumatology 2025;28(2):130-137
PURPOSE:
To judge the injury mode and injury severity of the real human body through the measured values of anthropomorphic test devices (ATD) injury indices, the mapping relationship of lumbar injury between ATD and human body model (HBM) was explored.
METHODS:
Through the ATD model and HBM simulation, the mapping relationship of lumbar injury between the 2 subjects was explored. The sled environment consisted of a semi-rigid seat with an adjustable seatback angle and a 3-point seat belt system with a seatback-mounted D-ring. Three seatback recline states of 25°, 45°, and 65° were designed, and the seat pan angle was maintained at 15°. A 23 g, 47 km/h pulse was used. The validity of the finite element model of the sled was verified by the comparison of ATD simulation and test results. ATD model was the test device for human occupant restraint for autonomous vehicles (THOR-AV) dummy model and HBM was the total human model for safety (THUMS) v6.1. The posture of the 2 models was adjusted to adapt to the 3 seat states. The lumbar response of THOR-AV and the mechanical and biomechanical data on L1 - L5 vertebrae of THUMS were output, and the response relationship between THOR-AV and THUMS was descriptive statistically analyzed.
RESULTS:
Both THOR-AV and THUMS were submarined in the 65° seatback angle case. With the change of seatback angle, the lumbar spine axial compression force (Fz) of THOR-AV and THUMS changed in the similar trend. The maximum Fz ratio of THOR-AV to THUMS at 25° and 45° seatback angle cases were 1.6 and 1.7. The flexion moment (My) and the time when the maximum My occurred in the 2 subjects were very different. In particular, the form of moment experienced by the L1 - L5 vertebrae of THUMS also changed. The changing trend of My measured by THOR-AV over time can reflect the changing trend of maximum stress of L1 and L2 of THUMS.
CONCLUSION
The Fz of ATD and HBM presents a certain proportional relationship, and there is a mapping relationship between the 2 subjects on Fz. The mapping function can be further clarified by applying more pulses and adopting more seatback angles. It is difficult to map My directly because they are very different in ATD and HBM. The My of ATD and stress of HBM lumbar showed a similar change trend over time, and there may be a hidden mapping relationship.
Humans
;
Lumbar Vertebrae/injuries*
;
Finite Element Analysis
;
Biomechanical Phenomena
;
Manikins
;
Spinal Injuries/physiopathology*
9.Association of higher serum follicle-stimulating hormone levels with successful microdissection testicular sperm extraction outcomes in nonobstructive azoospermic men with reduced testicular volumes.
Ming-Zhe SONG ; Li-Jun YE ; Wei-Qiang XIAO ; Wen-Si HUANG ; Wu-Biao WEN ; Shun DAI ; Li-Yun LAI ; Yue-Qin PENG ; Tong-Hua WU ; Qing SUN ; Yong ZENG ; Jing CAI
Asian Journal of Andrology 2025;27(3):440-446
To investigate the impact of preoperative serum follicle-stimulating hormone (FSH) levels on the probability of testicular sperm retrieval, we conducted a study of nonobstructive azoospermic (NOA) men with different testicular volumes (TVs) who underwent microdissection testicular sperm extraction (micro-TESE). A total of 177 NOA patients undergoing micro-TESE for the first time from April 2019 to November 2022 in Shenzhen Zhongshan Obstetrics and Gynecology Hospital (formerly Shenzhen Zhongshan Urology Hospital, Shenzhen, China) were retrospectively reviewed. The subjects were divided into four groups based on average TV quartiles. Serum hormone levels in each TV group were compared between positive and negative sperm retrieval subgroups. Overall sperm retrieval rate was 57.6%. FSH levels (median [interquartile range]) were higher in the positive sperm retrieval subgroup compared with the negative outcome subgroup when average TV was <5 ml (first quartile [Q1: TV <3 ml]: 43.32 [17.92] IU l -1 vs 32.95 [18.56] IU l -1 , P = 0.048; second quartile [Q2: 3 ml ≤ TV <5 ml]: 31.31 [15.37] IU l -1 vs 25.59 [18.40] IU l -1 , P = 0.042). Elevated serum FSH levels were associated with successful micro-TESE sperm retrieval in NOA men whose average TVs were <5 ml (adjusted odds ratio [OR]: 1.06 per unit increase; 95% confidence interval [CI]: 1.01-1.11; P = 0.011). In men with TVs ≥5 ml, larger TVs were associated with lower odds of sperm retrieval (adjusted OR: 0.84 per 1 ml increase; 95% CI: 0.71-0.98; P = 0.029). In conclusion, elevated serum FSH levels were associated with positive sperm retrieval in micro-TESE in NOA men with TVs <5 ml. In men with TV ≥5 ml, increases in average TVs were associated with lower odds of sperm retrieval.
Humans
;
Male
;
Azoospermia/surgery*
;
Sperm Retrieval/statistics & numerical data*
;
Adult
;
Follicle Stimulating Hormone/blood*
;
Retrospective Studies
;
Testis/pathology*
;
Microdissection
;
Organ Size
10.Explanation and interpretation of blood transfusion provisions for children with hematological diseases in the national health standard "Guideline for pediatric transfusion".
Ming-Yi ZHAO ; Rong HUANG ; Rong GUI ; Qing-Nan HE ; Ming-Yan HEI ; Xiao-Fan ZHU ; Jun LU ; Xiao-Jun XU ; Tian-Ming YUAN ; Rong ZHANG ; Xu WANG ; Jin-Ping LIU ; Jing WANG ; Zhi-Li SHAO ; Yong-Jian GUO ; Xin-Yin WU ; Jia-Rui CHEN ; Qi-Rong CHEN ; Jia GUO ; Ming-Hua YANG
Chinese Journal of Contemporary Pediatrics 2025;27(1):18-25
To guide clinical blood transfusion practices for pediatric patients, the National Health Commission has issued the health standard "Guideline for pediatric transfusion" (WS/T 795-2022). Blood transfusion is one of the most commonly used supportive treatments for children with hematological diseases. This guideline provides guidance and recommendations for blood transfusions in children with aplastic anemia, thalassemia, autoimmune hemolytic anemia, glucose-6-phosphate dehydrogenase deficiency, acute leukemia, myelodysplastic syndromes, immune thrombocytopenic purpura, and thrombotic thrombocytopenic purpura. This article presents the evidence and interpretation of the blood transfusion provisions for children with hematological diseases in the "Guideline for pediatric transfusion", aiming to assist in the understanding and implementing the blood transfusion section of this guideline.
Humans
;
Child
;
Hematologic Diseases/therapy*
;
Blood Transfusion/standards*
;
Practice Guidelines as Topic

Result Analysis
Print
Save
E-mail