1.Identification of critical quality attributes related to property and flavor of Jianwei Xiaoshi Tablets based on T1R2/T1R3/TRPV1-HEMT biosensor.
Dong-Hong LIU ; Yan-Yu HAN ; Jing WANG ; Hai-Yang LI ; Xin-Yu GUO ; Hui-Min FENG ; Han HE ; Shuo-Shuo XU ; Zhi-Jian ZHONG ; Zhi-Sheng WU
China Journal of Chinese Materia Medica 2025;50(14):3930-3937
The quality of traditional Chinese medicine(TCM) is a critical foundation for ensuring the stability of its efficacy, as well as the safety and effectiveness of its clinical use. The identification of critical quality attributes(CQAs) is one of the core components of TCM preparation quality control. This study focuses on Jianwei Xiaoshi Tablets and explores their CQAs related to property and flavor from the perspective of taste receptor proteins. Three taste receptor proteins, T1R2, T1R3, and TRPV1, were selected, and a biosensor based on high-electron-mobility transistor(HEMT) was constructed to detect the interactions between Jianwei Xiaoshi Tablets and taste receptor proteins. Simultaneously, liquid chromatography-mass spectrometry(LC-MS) technology was used to analyze the chemical composition of Jianwei Xiaoshi Tablets. In examining the interaction strength, the results indicated that the interaction between Jianwei Xiaoshi Tablets and TRPV1 protein was the strongest, followed by T1R3, with the interaction with T1R2 being relatively weaker. By combining biosensing technology with LC-MS, 16 chemical components were identified from Jianwei Xiaoshi Tablets, among which six were selected as CQAs for sweetness and seven for pungency. Further validation experiments demonstrated that CQAs such as hesperidin and hesperetin had strong interactions with their corresponding taste receptor proteins. Through the combined use of multiple technological approaches, this study successfully determined the property and flavor-related CQAs of Jianwei Xiaoshi Tablets. It provides novel ideas and approach for the identification of CQAs in TCM preparations and offers comprehensive theoretical support for TCM quality control, contributing to the improvement and development of TCM preparation quality control systems.
Drugs, Chinese Herbal/chemistry*
;
Biosensing Techniques/methods*
;
TRPV Cation Channels/chemistry*
;
Tablets/chemistry*
;
Receptors, G-Protein-Coupled/genetics*
;
Quality Control
;
Taste
;
Humans
;
Mass Spectrometry
2.Thermal sensitization of acupoints in patients with knee osteoarthritis: A cross-sectional case-control study.
Jian-Feng TU ; Xue-Zhou WANG ; Shi-Yan YAN ; Yi-Ran WANG ; Jing-Wen YANG ; Guang-Xia SHI ; Wen-Zheng ZHANG ; Li-Na JIN ; Li-Sha YANG ; Dong-Hua LIU ; Li-Qiong WANG ; Bao-Hong MI
Journal of Integrative Medicine 2025;23(3):289-296
OBJECTIVE:
Varied acupoint selections represent a potential cause of the uncertainty surrounding the efficacy of acupuncture for knee osteoarthritis (OA). Skin temperature, a guiding factor for acupoint selection, may help to address this issue. This study explored thermal sensitization of acupoints used for the treatment of knee OA.
METHODS:
This cross-sectional case-control study enrolled cases aged 45-75 years with symptomatic knee OA and age- and gender-matched non-knee OA controls in a 1:1 ratio. All participants underwent infrared thermographic imaging. The primary outcome was the relative skin temperature of acupoint (STA), and the secondary outcome was the absolute STA of 11 acupoints. The Z test was used to compare the relative and absolute STAs between the groups. Principal component analysis was used to extract the common factors (CFs, acupoint cluster) in the STAs. A general linear model was used to identify factors affecting the STA in the knee OA cases. For the group comparisons of relative STA, P < 0.0045 (adjusted for 11 acupoints through Bonferroni correction) was considered to indicate statistical significance. For other analyses, P < 0.05 was used as the threshold for statistical significance.
RESULTS:
The analysis included 308 participants, consisting of 151 cases (mean age: [64.58 ± 6.67] years; male: 25.83%; mean body mass index: [25.70 ± 3.16] kg/m2) and 157 controls (mean age: [63.37 ± 5.96] years; male: 26.11%; mean body mass index: [24.47 ± 2.84] kg/m2). The relative STAs of ST34 (P = 0.0001), EX-LE2 (P < 0.0001), EX-LE5 (P = 0.0006), SP10 (P < 0.0001), BL40 (P = 0.0012) and GB39 (P = 0.0037) were higher in the knee OA group. No difference was found in the STAs of ST35, ST36, SP9, GB33 and GB34. Four CFs were identified for relative STA in both groups. The acupoints within each CF were consistent between the groups. The mean values of the relative STAs across each CF were higher in the knee OA group. In the knee OA cases, no factors were observed to affect the relative STA, while age and gender were found to affect the absolute STA.
CONCLUSION
Among patients with knee OA, thermal sensitization occurs in the acupoints of the lower extremity, exhibiting localized and regional thermal consistencies. The thermally sensitized acupoints that we identified in this study, ST34, SP10, EX-LE2, EX-LE5, GB39 and BL40, may be good choices for the acupuncture treatment of knee OA. Please cite this article as: Tu JF, Wang XZ, Yan SY, Wang YR, Yang JW, Shi GX, Zhang WZ, Jing LN, Yang LS, Liu DH, Wang LQ, Mi BH. Thermal sensitization of acupoints in patients with knee osteoarthritis: A cross-sectional case-control study. J Integr Med. 2025; 23(3): 289-296.
Humans
;
Osteoarthritis, Knee/physiopathology*
;
Male
;
Cross-Sectional Studies
;
Middle Aged
;
Female
;
Acupuncture Points
;
Case-Control Studies
;
Aged
;
Skin Temperature
;
Acupuncture Therapy
3.International clinical practice guideline on the use of traditional Chinese medicine for functional dyspepsia (2025).
Sheng-Sheng ZHANG ; Lu-Qing ZHAO ; Xiao-Hua HOU ; Zhao-Xiang BIAN ; Jian-Hua ZHENG ; Hai-He TIAN ; Guan-Hu YANG ; Won-Sook HONG ; Yu-Ying HE ; Li LIU ; Hong SHEN ; Yan-Ping LI ; Sheng XIE ; Jin SHU ; Bin-Fang ZENG ; Jun-Xiang LI ; Zhen LIU ; Zheng-Hua XIAO ; Jing-Dong XIAO ; Pei-Yong ZHENG ; Shao-Gang HUANG ; Sheng-Liang CHEN ; Gui-Jun FEI
Journal of Integrative Medicine 2025;23(5):502-518
Functional dyspepsia (FD), characterized by persistent or recurrent dyspeptic symptoms without identifiable organic, systemic or metabolic causes, is an increasingly recognized global health issue. The objective of this guideline is to equip clinicians and nursing professionals with evidence-based strategies for the management and treatment of adult patients with FD using traditional Chinese medicine (TCM). The Guideline Development Group consulted existing TCM consensus documents on FD and convened a panel of 35 clinicians to generate initial clinical queries. To address these queries, a systematic literature search was conducted across PubMed, EMBASE, the Cochrane Library, China National Knowledge Infrastructure (CNKI), VIP Database, China Biology Medicine (SinoMed) Database, Wanfang Database, Traditional Medicine Research Data Expanded (TMRDE), and the Traditional Chinese Medical Literature Analysis and Retrieval System (TCMLARS). The evidence from the literature was critically appraised using the Grading of Recommendations Assessment, Development, and Evaluation (GRADE) approach. The strength of the recommendations was ascertained through a consensus-building process involving TCM and allopathic medicine experts, methodologists, pharmacologists, nursing specialists, and health economists, leveraging their collective expertise and empirical knowledge. The guideline comprises a total of 43 evidence-informed recommendations that span a range of clinical aspects, including the pathogenesis according to TCM, diagnostic approaches, therapeutic interventions, efficacy assessments, and prognostic considerations. Please cite this article as: Zhang SS, Zhao LQ, Hou XH, Bian ZX, Zheng JH, Tian HH, Yang GH, Hong WS, He YY, Liu L, Shen H, Li YP, Xie S, Shu J, Zeng BF, Li JX, Liu Z, Xiao ZH, Xiao JD, Zheng PY, Huang SG, Chen SL, Fei GJ. International clinical practice guideline on the use of traditional Chinese medicine for functional dyspepsia (2025). J Integr Med. 2025; 23(5):502-518.
Dyspepsia/drug therapy*
;
Humans
;
Medicine, Chinese Traditional/methods*
;
Practice Guidelines as Topic
;
Drugs, Chinese Herbal/therapeutic use*
4.Effects of Laparoscopic Sleeve Gastrectomy on Cardiac Structure and Function in Obese Patients With Heart Failure.
Xiao-Yan JIA ; Rui-Jia LIAN ; Bao-Dong MA ; Yang-Xi HU ; Qin-Jun CHU ; Hai-Yun JING ; Zhi-Qiang KANG ; Jian-Ping YE ; Xi-Wen MA
Acta Academiae Medicinae Sinicae 2025;47(2):226-236
Objective To investigate the effects of laparoscopic sleeve gastrectomy(LSG)on the cardiac structure and function in obese patients with heart failure(HF)and compare the efficacy of LSG across obese patients with different HF types.Methods This study included 33 obese patients with HF who underwent LSG.The clinical indicators were compared between before operation and 12 months after operation.Repeated measures analysis of variance was employed to evaluate the changes in echocardiographic parameters before operation and 3,6,and 12 months after operation.Patients were allocated into a HF with preserved ejection fraction group(n=17),a HF with mildly reduced ejection fraction group(n=5)and a HF with reduced ejection fraction(HFrEF)group(n=11)based on left ventricular ejection fraction(LVEF)before operation for subgroup analyses of the effects of LSG on the cardiac structure and function of obese patients with HF.The paired samples t-test was conducted to assess the degree of cardiac structural and functional alterations after LSG.Results The 33 patients included 69.7% males,with an average age of(35.3±9.9)years,and a body mass index(BMI)of(51.2±9.8)kg/m2.The median follow-up was 9.0(5.0,13.3)months.Compared with the preoperative values,the postoperative BMI(P=0.002),body surface area(BSA)(P=0.009),waist circumference(P=0.010),hip circumference(P=0.031),body fat content(P=0.007),and percentage of patients with cardiac function grades Ⅲ-IV(P<0.001)decreased.At the 12-month follow-up left atrial diameter(P=0.006),right atrial long-axis inner diameter(RAD1)(P<0.001),right atrial short-axis inner diameter(RAD2)(P<0.001),right ventricular inner diameter(P=0.002),interventricular septal thickness at end-diastolic(P=0.002),and left ventricular end-diastolic volumes(P=0.004)and left ventricular end-systolic volumes(P=0.003) all significantly reduced compared with preoperative values.Additionally,left ventricular fractional shortening and LVEF improved(both P<0.001).Subgroup analyses revealed that cardiac structural parameters significantly decreased in the HF with preserved ejection fraction,HF with mildly reduced ejection fraction,and HFrEF subgroups compared with preoperative values.Notably,the HFrEF group demonstrated the best performance in terms of left atrial diameter(P=0.003),left ventricular inner diameter at end-diastole(P=0.008),RAD1(P<0.001),RAD2(P=0.004),right ventricular inner diameter(P=0.019),left ventricular end-diastolic volume(P=0.004)and left ventricular end-systolic volume(P=0.001),cardiac output(P=0.006),tricuspid regurgitation velocity(P=0.002),and pulmonary artery systolic pressure(P=0.001) compared to preoperatively.Postoperative left ventricular fractional shortening(P<0.001,P=0.003,P<0.001)and LVEF(P<0.001,P=0.011,P=0.001)became higher in all the three subgroups than the preoperative values.Conclusions LSG decreased the body weight,BMI,and BSA,improved the cardiac function grade,reversed the enlargement of the left atrium and left ventricle,reduced the right atrium and right ventricle,and enhanced the left ventricular systolic function.It was effective across obese patients with different HF types.Particularly,LSG demonstrates the best performance in improving the structures of both atria and ventricles in obese patients with HFrEF.
Humans
;
Male
;
Female
;
Gastrectomy/methods*
;
Heart Failure/complications*
;
Adult
;
Obesity/physiopathology*
;
Laparoscopy
;
Middle Aged
;
Heart/physiopathology*
;
Stroke Volume
5.Application of 3D-printed auxiliary guides in adolescent scoliosis surgery.
Dong HOU ; Jian-Tao WEN ; Chen ZHANG ; Jin HUANG ; Chang-Quan DAI ; Kai LI ; Han LENG ; Jing ZHANG ; Shao-Bo YANG ; Xiao-Juan CUI ; Juan WANG ; Xiao-Yun YUAN
China Journal of Orthopaedics and Traumatology 2025;38(11):1119-1125
OBJECTIVE:
To investigate the accuracy and safety of pedicle screw placement using 3D-printed auxiliary guides in scoliosis correction surgery for adolescents.
METHODS:
A retrospective analysis was conducted on the clinical data of 51 patients who underwent posterior scoliosis correction surgery from January 2020 to March 2023. Among them, there were 35 cases of adolescent idiopathic scoliosis and 16 cases of congenital scoliosis. The patients were divided into two groups based on the auxiliary tool used:the 3D-printed auxiliary guide screw placement group (3D printing group) and the free-hand screw placement group (free-hand group, without auxiliary tools). The 3D printing group included 32 patients (12 males and 20 females) with an average age of (12.59±2.60) years;the free-hand group included 19 patients (7 males and 12 females) with an average age of (14.58±3.53) years. The two groups were compared in terms of screw placement accuracy and safety, spinal correction rate, intraoperative blood loss, number of intraoperative fluoroscopies, operation time, hospital stay, and preoperative and last follow-up scores of the Scoliosis Research Society-22 (SRS-22) questionnaire.
RESULTS:
A total of 707 pedicle screws were placed in the two groups, with 441 screws in the 3D printing group and 266 screws in the free-hand group. All patients in both groups successfully completed the surgery. There was a statistically significant difference in operation time between the two groups (P<0.05). The screw placement accuracy rate of the 3D printing group was 95.46% (421/441), among which the Grade A placement rate was 89.34% (394/441);the screw placement accuracy rate of the free-hand group was 86.47% (230/266), with a Grade A placement rate of 73.31% (195/266). There were statistically significant differences in the accuracy of Grade A, B, and C screw placements between the two groups (P<0.05), while no statistically significant differences were observed in intraoperative blood loss, number of fluoroscopies, correction rate, or hospital stay (P>0.05). In the SRS-22 questionnaire scores, the scores of functional status and activity ability, self-image, mental status, and pain of patients in each group at the last follow-up were significantly improved compared with those before surgery (P<0.05), but there were no statistically significant differences in all scores between the two groups (P>0.05).
CONCLUSION
In scoliosis correction surgery, compared with traditional free-hand screw placement, the use of 3D-printed auxiliary guides for screw placement significantly improves the accuracy and safety of screw placement and shortens the operation time.
Humans
;
Male
;
Scoliosis/surgery*
;
Female
;
Adolescent
;
Printing, Three-Dimensional
;
Retrospective Studies
;
Pedicle Screws
;
Child
6.Characteristics of Gut Microbiota Changes and Their Relationship with Infectious Complications During Induction Chemotherapy in AML Patients.
Quan-Lei ZHANG ; Li-Li DONG ; Lin-Lin ZHANG ; Yu-Juan WU ; Meng LI ; Jian BO ; Li-Li WANG ; Yu JING ; Li-Ping DOU ; Dai-Hong LIU ; Zhen-Yang GU ; Chun-Ji GAO
Journal of Experimental Hematology 2025;33(3):738-744
OBJECTIVE:
To investigate the characteristics of gut microbiota changes in patients with acute myeloid leukemia (AML) undergoing induction chemotherapy and to explore the relationship between infectious complications and gut microbiota.
METHODS:
Fecal samples were collected from 37 newly diagnosed AML patients at four time points: before induction chemotherapy, during chemotherapy, during the neutropenic phase, and during the recovery phase. Metagenomic sequencing was used to analyze the dynamic changes in gut microbiota. Correlation analyses were conducted to assess the relationship between changes in gut microbiota and the occurrence of infectious complications.
RESULTS:
During chemotherapy, the gut microbiota α-diversity (Shannon index) of AML patients exhibited significant fluctuations. Specifically, the diversity decreased significantly during induction chemotherapy, further declined during the neutropenic phase (P < 0.05, compared to baseline), and gradually recovered during the recovery phase, though not fully returning to baseline levels.The abundances of beneficial bacteria, such as Firmicutes and Bacteroidetes, gradually decreased during chemotherapy, whereas the abundances of opportunistic pathogens, including Enterococcus, Klebsiella, and Escherichia coli, progressively increased.Analysis of the dynamic changes in gut microbiota of seven patients with bloodstream infections revealed that the bloodstream infection pathogens could be detected in the gut microbiota of the corresponding patients, with their abundance gradually increasing during the course of infection. This finding suggests that bloodstream infections may be associated with opportunistic pathogens originating from the gut microbiota.Compared to non-infected patients, the baseline samples of infected patients showed a significantly lower relative abundance of Bacteroidetes (P < 0.05). Regression analysis indicated that Bacteroidetes abundance is an independent predictive factor for infectious complications (P < 0.05, OR =13.143).
CONCLUSION
During induction chemotherapy in AML patients, gut microbiota α-diversity fluctuates significantly, and the abundance of opportunistic pathogens increase, which may be associated with bloodstream infections. Patients with lower baseline Bacteroidetes abundance are more prone to infections, and its abundance can serve as an independent predictor of infectious complications.
Humans
;
Gastrointestinal Microbiome
;
Leukemia, Myeloid, Acute/microbiology*
;
Induction Chemotherapy
;
Feces/microbiology*
;
Male
;
Female
;
Middle Aged
7.Robot-assisted percutaneous coronary intervention: a prospective, multicenter, randomized controlled, non-inferiority clinical trial.
Yi YU ; Zheng CHEN ; Zhi-Jian WANG ; Yue-Ping LI ; Li-Xia YANG ; Jing QI ; Jing XIE ; Tao HUANG ; Dong-Mei SHI ; Yu-Jie ZHOU
Journal of Geriatric Cardiology 2025;22(8):725-735
OBJECTIVE:
To evaluate the safety and effectiveness of robot-assisted percutaneous coronary intervention (R-PCI) compared to traditional manual percutaneous coronary intervention (M-PCI).
METHODS:
This prospective, multicenter, randomized controlled, non-inferior clinical trial enrolled patients with coronary heart disease who met the inclusion criteria and had indications for elective percutaneous coronary intervention. Participants were randomly assigned to either the R-PCI group or the M-PCI group. Primary endpoints were clinical and technical success rates. Clinical success was defined as visually estimated residual post-percutaneous coronary intervention stenosis < 30% with no 30-day major adverse cardiac events. Technical success in the R-PCI group was defined as successful completion of percutaneous coronary intervention using the ETcath200 robot-assisted system, without conversion to M-PCI in the event of a guidewire or balloon/stent catheter that was unable to cross the vessel or was poorly supported by the catheter. Secondary endpoints included total procedure time, percutaneous coronary intervention procedure time, fluoroscopy time, contrast volume, operator radiation exposure, air kerma, and dose-area product.
RESULTS:
The trial enrolled 152 patients (R-PCI: 73 patients, M-PCI: 79 patients). Lesions were predominantly B2/C type (73.6%). Both groups achieved 100% clinical success rate. No major adverse cardiac events occurred during the 30-day follow-up. The R-PCI group had a technical success rate of 100%. The R-PCI group had longer total procedure and fluoroscopy times, but lower operator radiation exposure. The percutaneous coronary intervention procedure time, contrast volume, air kerma, and dose-area product were similar between the two groups.
CONCLUSIONS
For certain complex lesions, performing percutaneous coronary intervention using the ETcath200 robot-assisted system is safe and effective and does not result in conversion to M-PCI.
8.RCM method-based study on preventive maintenance strategy of heating,ventilation and air-conditioning system in pharmacy intravenous admixture services
Liu-liu ZONG ; Yun-zhi YANG ; Jing ZHAO ; Yun MO ; Dong-hui LAO ; Jian-zhong ZHANG ; Xiao-yu LI ; Qian-zhou LYU
Chinese Medical Equipment Journal 2025;46(10):78-83
Objective To propose a preventive maintenance strategy of the heating,ventilation and air-conditioning(HVAC)system in pharmacy intravenous admixture services(PIVAS)based on the reliability centered maintenance(RCM)method so as to provide references for PIVAS equipment maintenance.Methods Firstly,a HVAC system RCM review team was formed,and the failure modes and impacts of important functional components of the equipment were analyzed to clarify the consequences of the failure of each functional component under the premise of ensuring the safety and integrity of the equipment and with the goal of minimizing the loss of maintenance downtime and the consumption of maintenance resources.Secondly,with a standardized logical decision-making procedure the preventive maintenance strategy was determined and implemented based on the consequences of functional failure.Finally,statistical analyses were carried out on such equipment indicators as performance parameter qualification rate,failure rate and maintenance cost before and after the RCM method-based strategy was executed,in order to evaluate the efficacy of the strategy.Results The RCM method-based preventive maintenance strategy had the performance qualification rate increased from 97.47%to 99.06%(χ2=24.139,P<0.01),the failure rate decreased from 0.24%to 0.03%(χ2=13.519,P<0.01)and the maintenance cost reduced by 11.5%,from RMB 134,200 to 118,700.Conclusion The RCM method-based preventive maintenance strategy provides reliable equipment for PIVAS and lowers the maintenance cost effectively,and references are given for the development of automated and intelligent equipment maintenance strategies for PIVAS.[Chinese Medical Equipment Journal,2025,46(10):78-83]
9.Renal metabolomics study of Huangqi preparations for alleviating nephrotoxicity of cisplatin
Ying XU ; Qing YOU ; Hui-zhi LUO ; Qi-rui HE ; Jian-dong ZOU ; Jing WANG ; Chang-yin LI
Chinese Pharmacological Bulletin 2025;41(11):2113-2119
Aim To investigate the effect of Huangqi injection(HI)and Huangqi oral solution(HO)on cisplatin-induced nephrotoxicity(CIN)based on un-targeted metabolomics technology and the underlying mechanisms.Methods Sprague Dawley(SD)rats were randomly divided into the blank group,cisplatin(CDDP)model group,HI treatment group,and HO treatment group,then the CIN model was built with low dose multiple intraperitoneal injections of CDDP.Pre-liminary evaluation of the renal protective efficacy of HI and HO was performed by measuring serum creatinine(Scr),blood urea nitrogen(BUN),and organ indi-ces.Further screening and identification of potential biomarkers(PBs)related to CIN and HI/HO pharma-cological effects were attained through metabolomics studies of renal tissues,and pathway enrichment analy-sis was conducted.Results HI and HO significantly restored the abnormal increase in renal function indica-tors and abnormal decrease in organ indices caused by CDDP,as well as significantly improved the abnormal renal metabolic profile induced by CDDP,indicating that both HI and HO had good alleviating effects on CIN.HI significantly reversed 47 out of 54 CIN related PBs,mainly involving metabolic pathways such as glycerophospholipid metabolism,tryptophan metabo-lism,pantothenate and CoA biosynthesis;HO signifi-cantly reversed 18 out of 54 CIN related PBs,mainly involving metabolic pathways such as taurine and hypo-taurine metabolism,ascorbate and aldarate metabo-lism,pentose and glucuronate interconversions.Con-clusions Both HI and HO have significant alleviating effects on CIN.In the short term,HI salleviating effect is superior to that of HO.Overall,the mechanisms by which both alleviate CIN are mainly related to regula-ting lipid metabolism,amino acid metabolism.
10.Self-developed real-time three-dimensional intracardiac echocardiography system
Jing WANG ; Dongyu ZHANG ; Nan WU ; Zhanbo HAN ; Sheng GUO ; Jian QI ; Guoliang WU ; Chuhao YIN ; Dong ZHANG
Chinese Journal of Medical Imaging Technology 2025;41(10):1653-1658
Objective To observe the performance and safety of self-developed real-time three-dimensional intracardiac echocardiography(ICE)system(system).Methods The self-developed system was constructed using disposable sterile real-time three-dimensional ICE catheter(catheter)and multifunctional cart-mounted digital ultrasound imaging host(ultrasound host).The diameter of catheter was 10F,with effective length of 90 cm and two-dimensional array transducer array(840 elements)integrated at tip.The ultrasound host was connected to the catheter through matching connector.The performance of this system was evaluated with self-made experimental equipment and standard phantom,and live animal experiment was performed to observe its safety and imaging quality.Results The maximum imaging depth of this system was ≥60 mm.Its axial resolution was ≤1 mm and lateral resolution was ≤1 mm within the depth of 40 mm,the horizontal and vertical geometric position accuracy errors were ≤10%and ≤5%,respectively,while the image geometric distortion was ≤10%,and the measurement volume error was ≤30%.The catheter was successfully inserted into right atrium of pig through femoral vein under ultrasound guidance,smoothly passing through the vascular pathway without any bending or jamming with good controllability.The cardiac images of this system were clear,which completely displayed cardiac chamber structures,and the image resolution met diagnostic requirement.No injury related to interventional procedures was found in laboratory tests nor anatomical results.Conclusion The self-developed ICE system was stable and safe,and initial results showed it could meet clinical application expectations.

Result Analysis
Print
Save
E-mail