1.Design of combat rescue specialized physical training simulator
Hong-tao XING ; Shi-wei XU ; Jian-hua WANG ; Jing-chang LU ; Ke-chao ZHAO ; Cheng CUI
Chinese Medical Equipment Journal 2025;46(1):33-37
Objective To design a combat rescue specialized physical training simulator to solve the problems of the existing combat rescue physical traing in multifunctionality and simulation vividness.Methods The simulator was divided into three types for stretcher handling,land combat rescue and marine rescue based on the application scenerio and functional positioning,and into three grades of basic level,intensive level and ultra intensive level based on the loaded mass and additional weight object.The main components of the simulator included a manikin,a bionic joint and addtional weight objects.The manikin was made up of outer skin,inner liner and skeleton;the bionic joint was made of stainless steel with surface electrophoresis treatment,and was composed of high-strength medal bearing shafts with multiple disc springs and damping mechanisms;the additional weight objects involued in high-intensity cast iron or lead blocks,which were pre-embedded,mounted or srtapped into the simulator.The simulator was verified with body shape and mass detection,drop test,waterproof test and drag test.Results It's proved the simulator gained advantages in vividness for body shape and mass,bionic joint structure and adaptability to training environments and could be used for graded physical training in typical combat rescue scenerios.Conclusion The simulator developed solves the problems of the combat rescue specialized physical training equipment,and facilitates the enhancement of physical training of combat rescue personnel.[Chinese Medical Equipment Journal,2025,46(1):33-37]
2.Study on decision tree-based optimization algorithm for medical equipment fault diagnosis
Zi-jian YANG ; Ke-chao ZHAO ; Jing-chang LU ; Hong-tao XING
Chinese Medical Equipment Journal 2025;46(5):78-83
Objective To propose a decision tree-based optimization algorithm to shorten the time spent and to improve the decision-making efficiency for medical device fault diagnosis.Methods Firstly,a binarized fault state space for medical equipment was constructed;secondly,the binarized fault state space was simplified with logical functions;finally,a greedy algorithm was applied to iterative judgment to build a decision tree for medical device fault diagnosis.The algorithm proposed was compared with the greedy algorithm,Gini coefficient method and random forest algorithm in terms of the result accuracy and time cost and the influences of fault probability distribution and time-consuming differences for the algorithms.A case study on gastric lavage machine fault diagnosis was conducted to demonstrate the algorithm.Results The algorithm proposed behaved better than the greedy algorithm,Gini coefficient method and random forest algorithm in lowered time cost and result accuracy.However,the algorithm showed a decrease in accuracy for the logarithmic distribution of the detection method's time consumption,and it was not sensitive to the changes in the failure rate distribution.The gastric lavage machine case study demonstrated that the algorithm was functionally similar to an experienced engineer.Conclusion The proposed algorithm with overall perspective effectively enhances fault judgment efficiency and facilitates rapid diagnostic decision-making in medical equipment maintenance.[Chinese Medical Equipment Journal,2025,46(5):78-83]
3.Endoplasmic reticulum membrane remodeling by targeting reticulon-4 induces pyroptosis to facilitate antitumor immune.
Mei-Mei ZHAO ; Ting-Ting REN ; Jing-Kang WANG ; Lu YAO ; Ting-Ting LIU ; Ji-Chao ZHANG ; Yang LIU ; Lan YUAN ; Dan LIU ; Jiu-Hui XU ; Peng-Fei TU ; Xiao-Dong TANG ; Ke-Wu ZENG
Protein & Cell 2025;16(2):121-135
Pyroptosis is an identified programmed cell death that has been highly linked to endoplasmic reticulum (ER) dynamics. However, the crucial proteins for modulating dynamic ER membrane curvature change that trigger pyroptosis are currently not well understood. In this study, a biotin-labeled chemical probe of potent pyroptosis inducer α-mangostin (α-MG) was synthesized. Through protein microarray analysis, reticulon-4 (RTN4/Nogo), a crucial regulator of ER membrane curvature, was identified as a target of α-MG. We observed that chemically induced proteasome degradation of RTN4 by α-MG through recruiting E3 ligase UBR5 significantly enhances the pyroptosis phenotype in cancer cells. Interestingly, the downregulation of RTN4 expression significantly facilitated a dynamic remodeling of ER membrane curvature through a transition from tubules to sheets, consequently leading to rapid fusion of the ER with the cell plasma membrane. In particular, the ER-to-plasma membrane fusion process is supported by the observed translocation of several crucial ER markers to the "bubble" structures of pyroptotic cells. Furthermore, α-MG-induced RTN4 knockdown leads to pyruvate kinase M2 (PKM2)-dependent conventional caspase-3/gasdermin E (GSDME) cleavages for pyroptosis progression. In vivo, we observed that chemical or genetic RTN4 knockdown significantly inhibited cancer cells growth, which further exhibited an antitumor immune response with anti-programmed death-1 (anti-PD-1). In translational research, RTN4 high expression was closely correlated with the tumor metastasis and death of patients. Taken together, RTN4 plays a fundamental role in inducing pyroptosis through the modulation of ER membrane curvature remodeling, thus representing a prospective druggable target for anticancer immunotherapy.
Pyroptosis/immunology*
;
Humans
;
Endoplasmic Reticulum/immunology*
;
Animals
;
Nogo Proteins/antagonists & inhibitors*
;
Mice
;
Cell Line, Tumor
;
Xanthones/pharmacology*
;
Neoplasms/pathology*
;
Mice, Nude
4.Coronary artery stenosis associated with right ventricular dysfunction in acute pulmonary embolism: A case-control study.
Yuejiao MA ; Jieling MA ; Dan LU ; Yinjian YANG ; Chao LIU ; Liting WANG ; Xijie ZHU ; Xianmei LI ; Chunyan CHENG ; Sijin ZHANG ; Jiayong QIU ; Jinghui LI ; Mengyi LIU ; Kai SUN ; Xin JIANG ; Xiqi XU ; Zhi-Cheng JING
Chinese Medical Journal 2025;138(16):2028-2036
BACKGROUND:
The potential impact of pre-existing coronary artery stenosis (CAS) on right ventricular (RV) function during acute pulmonary embolism (PE) episodes remains underexplored. This study aimed to investigate the association between pre-existing CAS and RV dysfunction in patients with acute PE.
METHODS:
In this multicenter, case-control study, 89 cases and 176 controls matched for age were enrolled at three study centers (Peking Union Medical College Hospital, Fuwai Hospital, and the Second Affiliated Hospital of Harbin Medical University) from January 2016 to December 2020. The cases were patients with acute PE with CAS, and the controls were patients with acute PE without CAS. Coronary artery assessment was performed using coronary computed tomographic angiography. CAS was defined as ≥50% stenosis of the lumen diameter in any coronary vessel >2.0 mm in diameter. Conditional logistic regression analysis was used to evaluate the association between CAS and RV dysfunction.
RESULTS:
The percentages of RV dysfunction (19.1% [17/89] vs. 44.6% [78/176], P <0.001) and elevated systolic pulmonary artery pressure (sPAP) (19.3% [17/89] vs. 39.5% [68/176], P = 0.001) were significantly lower in the case group than those in the control group. In the multivariable logistic regression model, CAS was independently and negatively associated with RV dysfunction (adjusted odds ratio [OR]: 0.367; 95% confidence interval [CI]: 0.185-0.728; P = 0.004), and elevated sPAP (OR: 0.490; 95% CI: 0.252-0.980; P = 0.035), respectively.
CONCLUSIONS
Pre-existing CAS was significantly and negatively associated with RV dysfunction and elevated sPAP in patients with acute PE. This finding provides new insights into RV dysfunction in patients with acute PE with pre-existing CAS.
Humans
;
Pulmonary Embolism/complications*
;
Case-Control Studies
;
Male
;
Ventricular Dysfunction, Right/physiopathology*
;
Female
;
Middle Aged
;
Aged
;
Coronary Stenosis/complications*
;
Logistic Models
;
Adult
5.Design and application of novel protective ventilator circuit component
Wei-zhou WU ; Kang LU ; Jing-jie CAO ; Zhi-hua ZHAO ; Hai-tao LAN ; Zan-chao CHEN ; Qing-feng XUE
Chinese Medical Equipment Journal 2025;46(4):113-117
Objective To develop a novel protective ventilator circuit component and to verify its performance by water seal and anti-splash experiments.Methods A novel protective ventilator circuit component had a design scheme with the multifunctional joint,and consisted of a tee connection tube,an isolation sleeve and a stop sleeve,of which,the tee connection tube was made of polyethylene polymer material and the others were made of silicone material.The tee connection tube had a T-shaped structure with two standard connection ports,which was composed of an adapter,a sealing cap,a plug and a sealing ring;the isolation sleeve was in the shape of a cylinder with a raised bottom,which was inserted into the adapter;the stop sleeve was located in the isolation sleeve,with an inverted frustum of a cone at the bottom and a rounded hole in the middle of the inverted frustum.An open ventilator circuit tube was involved in the performance verification of the circuit component developed.In the water seal experiment,sputum aspiration was simulated and the heights of the liquid level drop in the L-shaped tubes were compared after sputum aspiration.In the anti-splash experiment,the infection rates on the surfaces of the sterile hole towels and gloves were calculated.Results Water seal experiment showed after sputum aspiration the open ventilator circuit tube had the liquid level at the L-shaped tube higher significantly than that of the circuit component;the anti-splash experiment indicated sputum aspiration resulted in the occurance of the splashing out of the secretion and 77.5%infection rate by the open ventilator circuit tube,while no splashing out and 0%infection rate by the circuit component developed.Conclusion The novel protective ventilator circuit component behaves well in sealing and anti-splashing,and thus is worthy of clinical application for sputum aspiration.[Chinese Medical Equipment Journal,2025,46(4):113-117]
6.Design and application of novel protective ventilator circuit component
Wei-zhou WU ; Kang LU ; Jing-jie CAO ; Zhi-hua ZHAO ; Hai-tao LAN ; Zan-chao CHEN ; Qing-feng XUE
Chinese Medical Equipment Journal 2025;46(4):113-117
Objective To develop a novel protective ventilator circuit component and to verify its performance by water seal and anti-splash experiments.Methods A novel protective ventilator circuit component had a design scheme with the multifunctional joint,and consisted of a tee connection tube,an isolation sleeve and a stop sleeve,of which,the tee connection tube was made of polyethylene polymer material and the others were made of silicone material.The tee connection tube had a T-shaped structure with two standard connection ports,which was composed of an adapter,a sealing cap,a plug and a sealing ring;the isolation sleeve was in the shape of a cylinder with a raised bottom,which was inserted into the adapter;the stop sleeve was located in the isolation sleeve,with an inverted frustum of a cone at the bottom and a rounded hole in the middle of the inverted frustum.An open ventilator circuit tube was involved in the performance verification of the circuit component developed.In the water seal experiment,sputum aspiration was simulated and the heights of the liquid level drop in the L-shaped tubes were compared after sputum aspiration.In the anti-splash experiment,the infection rates on the surfaces of the sterile hole towels and gloves were calculated.Results Water seal experiment showed after sputum aspiration the open ventilator circuit tube had the liquid level at the L-shaped tube higher significantly than that of the circuit component;the anti-splash experiment indicated sputum aspiration resulted in the occurance of the splashing out of the secretion and 77.5%infection rate by the open ventilator circuit tube,while no splashing out and 0%infection rate by the circuit component developed.Conclusion The novel protective ventilator circuit component behaves well in sealing and anti-splashing,and thus is worthy of clinical application for sputum aspiration.[Chinese Medical Equipment Journal,2025,46(4):113-117]
7.Best essential surgical technique training course to improve surgical residents′ laparoscopic peritoneal suturing skills: a cohort study
Zhenghao CAI ; Haiqin SONG ; Jing SUN ; Pei XUE ; Luyang ZHANG ; Chao WU ; Hiju HONG ; Xi CHENG ; Sen ZHANG ; Minhua ZHENG ; Lu ZANG ; Ruijun PAN ; Jianwen LI ; Bo FENG
Journal of Surgery Concepts & Practice 2025;30(2):132-137
Objective To explore the effectiveness of an integrated laparoscopic simulation training course (best essential surgical technique training, BEST) in enhancing laparoscopic peritoneal suturing techniques in surgical residents.Methods As an integrated two-stage program, the BEST course applied basic laparoscopic training system with simple molds in phase Ⅰ training, and then adopted advanced laparoscopic training system, 3D Laparoscope and ex-vivo animal models in phase Ⅱ training. The laparoscopic suturing techniques were practiced in phase Ⅱ training. From August 2021 to July 2024, surgical residents in the second year of the national standardized training program were divided into pilot and control groups based on whether they had undergone the BEST course. Two cases of laparoscopic peritoneal suture were performed by the surgical residents under supervision in the department of gastrointestinal surgery. The operative time, quality of suture, and independent completion rate were compared between the two groups.Results A total of 33 surgical residents (19 in pilot group and 14 in control group) were included in this study, and a total of 66 cases of laparoscopic peritoneal suture were performed (38 in pilot group and 28 in control group). The operative time was significantly shorter in pilot group than that in control group (15.7 min vs. 17.5 min, P=0.025). The quality of suture was significantly better in pilot group compared to control group (P=0.023). In pilot group, all peritoneal sutures were performed by residents independently, whereas in control group, 3 cases (10.7%) were assisted by the supervisor, and the independent completion rate was different significantly (P=0.039).Conclusions The BEST course can help improve surgical residents′ laparoscopic peritoneal suturing techniques and could be promoted in the national standardized training program for surgical residents.
8.Molecular targeted therapy for progressive low-grade gliomas in children.
Yan-Ling SUN ; Miao LI ; Jing-Jing LIU ; Wen-Chao GAO ; Yue-Fang WU ; Lu-Lu WAN ; Si-Qi REN ; Shu-Xu DU ; Wan-Shui WU ; Li-Ming SUN
Chinese Journal of Contemporary Pediatrics 2025;27(6):682-689
OBJECTIVES:
To evaluate the efficacy of molecular targeted agents in children with progressive pediatric low-grade gliomas (pLGG).
METHODS:
A retrospective analysis was conducted on pLGG patients treated with oral targeted therapies at the Department of Pediatrics, Beijing Shijitan Hospital, Capital Medical University, from July 2021. Treatment responses and safety profiles were assessed.
RESULTS:
Among the 20 enrolled patients, the trametinib group (n=12, including 11 cases with BRAF fusions and 1 case with BRAF V600E mutation) demonstrated 4 partial responses (33%) and 2 minor responses (17%), with a median time to response of 3.0 months. In the vemurafenib group (n=6, all with BRAF V600E mutation), 5 patients achieved partial responses (83%), showing a median time to response of 1.0 month. Comparative analysis revealed no statistically significant difference in progression-free survival rates between the two treatment groups (P>0.05). The median duration of clinical benefit (defined as partial response + minor response + stable disease) was 11.0 months for vemurafenib and 18.0 months for trametinib. Two additional cases, one with ATM mutation treated with olaparib for 24 months and one with NF1 mutation receiving everolimus for 21 months, discontinued treatment due to sustained disease stability. No severe adverse events were observed in any treatment group.
CONCLUSIONS
Molecular targeted therapy demonstrates clinical efficacy with favorable tolerability in pLGG. Vemurafenib achieves high response rates and induces early tumor shrinkage in patients with BRAF V600E mutations, supporting its utility as a first-line therapy.
Humans
;
Glioma/genetics*
;
Male
;
Female
;
Child
;
Child, Preschool
;
Retrospective Studies
;
Brain Neoplasms/genetics*
;
Molecular Targeted Therapy/adverse effects*
;
Adolescent
;
Infant
;
Proto-Oncogene Proteins B-raf/genetics*
;
Pyrimidinones/therapeutic use*
;
Mutation
9.The effect and mechanism of Jianpi Qinghua granule in improving skeletal muscle insulin resistance induced by cadmium exposure in rats
Chi CHEN ; Yuan CHEN ; Ningjian WANG ; Junfei XU ; Xu HAN ; Yanyan XIAO ; Jing TIAN ; Chao WANG ; Mengjie CAI ; Qingguang CHEN ; Hao LU
Chinese Journal of Endocrinology and Metabolism 2025;41(1):54-60
Objective:To investigate the effect and mechanism of Jianpi Qinghua granule in improving skeletal muscle insulin resistance induced by long-term low-dose cadmium exposure in rats.Methods:A total of 24 SPF-grade healthy 2-month-old Sprague-Dawley rats were assigned to normal control(NC) group, cadmium exposure(Cd) group, and Jianpi Qinghua granule protection(Cd+ JPQHG) group. After 24 weeks, fasting blood glucose and insulin levels were measured, and HOMA-IR was calculated. The intraperitoneal glucose tolerance test and insulin tolerance test were conducted to assess insulin sensitivity. Skeletal muscle tissues were extracted for Western blot analysis to detect levels of insulin signaling pathway-related proteins. Immunofluorescence was used to assess the translocation of glucose transporter 4(GLUT4), and oxidative stress markers were measured.Results:Compared to the NC group, the Cd group showed significant increases in fasting plasma glucose, fasting insulin levels, and HOMA-IR after 24-week exposure. Abnormal glucose and insulin tolerance were also observed in the Cd group. The 12-week intervention with Jianpi Qinghua granule significantly improved glucose metabolism and alleviated the abnormalities in glucose and insulin tolerance. Western blot results indicated that the phosphorylation levels of PI3K and Akt in the skeletal muscle of the Cd group were significantly reduced compared to the NC group, while these levels were significantly elevated in the Cd+ JPQHG group, along with increased translocation of GLUT4 to the cell membrane. Additionally, cadmium exposure significantly increased H 2O 2 and malondialdehyde levels while decreased antioxidant enzyme activity. These oxidative stress indicators improved significantly after Jianpi Qinghua granule intervention( P<0.05). Conclusion:Jianpi Qinghua granule may improve skeletal muscle insulin resistance and glucose metabolism disorders due to long-term low-dose cadmium exposure by reducing oxidative stress, regulating the phosphorylation levels of key proteins in the insulin signaling pathway, and promoting GLUT4 translocation to the cell membrane.
10.Study on decision tree-based optimization algorithm for medical equipment fault diagnosis
Zi-jian YANG ; Ke-chao ZHAO ; Jing-chang LU ; Hong-tao XING
Chinese Medical Equipment Journal 2025;46(5):78-83
Objective To propose a decision tree-based optimization algorithm to shorten the time spent and to improve the decision-making efficiency for medical device fault diagnosis.Methods Firstly,a binarized fault state space for medical equipment was constructed;secondly,the binarized fault state space was simplified with logical functions;finally,a greedy algorithm was applied to iterative judgment to build a decision tree for medical device fault diagnosis.The algorithm proposed was compared with the greedy algorithm,Gini coefficient method and random forest algorithm in terms of the result accuracy and time cost and the influences of fault probability distribution and time-consuming differences for the algorithms.A case study on gastric lavage machine fault diagnosis was conducted to demonstrate the algorithm.Results The algorithm proposed behaved better than the greedy algorithm,Gini coefficient method and random forest algorithm in lowered time cost and result accuracy.However,the algorithm showed a decrease in accuracy for the logarithmic distribution of the detection method's time consumption,and it was not sensitive to the changes in the failure rate distribution.The gastric lavage machine case study demonstrated that the algorithm was functionally similar to an experienced engineer.Conclusion The proposed algorithm with overall perspective effectively enhances fault judgment efficiency and facilitates rapid diagnostic decision-making in medical equipment maintenance.[Chinese Medical Equipment Journal,2025,46(5):78-83]

Result Analysis
Print
Save
E-mail