1.A retrospective cohort analysis on the association between blood donation intervals and adverse reactions to blood donation in Shenzhen, China
Li NING ; Yanyan ZHANG ; Jinfeng ZENG ; Jingya HUANG ; Liqin HUANG ; Xuqun WU ; Litao WU
Chinese Journal of Blood Transfusion 2026;39(3):346-352
Objective: To statistically analyze the association between blood donation intervals and the incidence of adverse reactions to blood donation based on blood donor data from Shenzhen. Methods: Basic data and records of adverse reactions to blood donation among voluntary whole blood donors in Shenzhen from January 2017 to June 2025 were extracted. A total of 795 404 whole blood donations were recorded, including 502 743 from males and 292 661 from females, with 1 088 and 751 cases of adverse reactions, respectively. Analyses were performed using R software, including restricted cubic spline (RCS), binary logistic regression, and generalized estimating equations (GEE) to evaluate the correlation between donation intervals and adverse reactions. Results: A total of 1 839 cases of adverse reactions were recorded, accounting for 0.23% of the total donations. Both binary logistic regression analysis and the generalized estimating equations (GEE) model showed that there was no significant difference in the incidence of adverse reactions between male and female donors with an interval of ≥6 months compared to those with an interval of ≥3 months but<6 months. Furthermore, using the 3-5 month interval group as the reference, the analysis indicated that the incidence of adverse reactions significantly increased in males with a 9-12 month interval, while no statistically significant differences were observed across any of the female subgroups. Conclusion: There was no significant correlation between adverse reactions to blood donation and the donation interval. Compared with a donation interval of ≥6 months, an interval of<6 months does not lead to an increase in the incidence of adverse reactions among male or female donors. The findings of this study may help enhance the willingness of blood donors to participate.
2.A retrospective cohort analysis on the association between blood donor age and adverse reactions to blood donation in Shenzhen
Litao WU ; Yanyan ZHANG ; Jinfeng ZENG ; Jingya HUANG ; Liqin HUANG ; Xuqun WU ; Li NING
Chinese Journal of Blood Transfusion 2026;39(3):353-359
Objective: To statistically analyze the association between blood donor age and the incidence of adverse reactions based on whole blood donor data from Shenzhen. Methods: Data on basic characteristics and records of adverse donation reactions among voluntary whole blood donors in Shenzhen from January 2017 to June 2025 were extracted. A total of 795 404 whole blood donations were recorded, including 502 743 from males and 292 661 from females, with 1 088 and 751 cases of adverse reactions, respectively. Analyses were performed using R software, including restricted cubic spline (RCS) analysis, binary logistic regression, and generalized estimating equations (GEE) to evaluate the correlation between donor age and adverse reactions. Results: A total of 1 839 cases of adverse reactions were recorded, accounting for 0.23% of the total donations. Both binary logistic regression and GEE model revealed that, compared with the≤55 years age group, the incidence of adverse reactions was reduced in both male and female donors in the >55 years age group, with the difference being statistically significant in males. Using the <23 years age group as a reference, the incidence of adverse reactions significantly decreased in both male and female donors across the 23-30, 31-40, 41-50, and 51-60 age groups, with the differences being statistically significant. Conclusion: There is a negative correlation between the rate of adverse donation reactions and age, with the incidence of such reactions among whole blood donors over 55 years old being no higher than that among donors aged 55 years or younger. These findings carry positive significance for safeguarding the donation rights of older donors and meeting clinical blood demand.
3.Rapid rehabilitation nursing for one pediatric patient with pancreatic divisum undergoing en bloc pancreatoduodenectomy
Jinfeng ZHU ; Weishu HU ; Li TANG ; Lei CAI ; Rong HUANG ; Lechun HUANG ; Ruixin ZHENG ; Jing CAO
Journal of Clinical Medicine in Practice 2025;29(7):118-121
This article summarizes the rapid rehabilitation nursing experience for one pediatric pa-tient with pancreatic divisum who underwent en bloc pancreatoduodenectomy preserving the duodenum,common bile duct,and Oddi's sphincter(DCOPPHTR).The nursing care encompassed preoperative prehabilitation to enhance physical and psychological preparation,postoperative precise volume and dynamic blood glucose management,early mobilization to facilitate recovery,personalized nutritional support to improve nutritional status,psychological nursing to bolster confidence,and family involve-ment to enhance quality of life.The pediatric patient experienced rapid recovery and was discharged from the hospital.A six-month follow-up indicated a significant improvement in quality of life.
4.Development of a public health performance evaluation system for maternity and child health hospi-tals:an empirical study using on module quantification and standard work hour quotas
Jinfeng LI ; Jieying RUAN ; Xiuhui HUANG ; Yongmei CHEN
Modern Hospital 2025;25(11):1729-1732,1738
Objective Maternal-and-child health(MCH)hospitals simultaneously provide clinical care and manage community-based public-health projects for women and children.We aimed to design and test a performance-based salary and e-valuation system that recognizes this dual responsibility and incentivizes high-quality public-health work.Methods Aligned with the national tertiary-level MCH-hospital performance appraisal standards and local project realities,we applied four industrial-en-gineering techniques—empirical time-and-motion estimation,classification,analogy and work-study—to convert every public-health project into quantifiable modules with pre-set labor-hour quotas.Bonuses were calculated under"more work,more pay"and"increment incentive"rules,while appraisal covered two dimensions:(ⅰ)project-specific indicators(coverage,timeliness,completeness)and(ⅱ)outcome evaluation(health impact and user satisfaction).Performance pay was then approved and dis-tributed to staff responsible for project management.Results Analysis of the 2022-2024 implementation period showed clear gains:① Work-force mobilization:departments managing MCH projects grew from 17 to 22 and staff from 22 to 73;all core pro-ject indicators improved significantly.② Service expansion:valid service volume generated by jurisdiction-level MCH project ac-tivities rose by 62.31%.Conclusion The scientific,standardized and operable performance and evaluation system for maternity and child projects developed in this study can help effectively improve the management efficiency of maternity and child projects in the jurisdiction and promote the high-quality development of the hospital.
5.Development of a public health performance evaluation system for maternity and child health hospi-tals:an empirical study using on module quantification and standard work hour quotas
Jinfeng LI ; Jieying RUAN ; Xiuhui HUANG ; Yongmei CHEN
Modern Hospital 2025;25(11):1729-1732,1738
Objective Maternal-and-child health(MCH)hospitals simultaneously provide clinical care and manage community-based public-health projects for women and children.We aimed to design and test a performance-based salary and e-valuation system that recognizes this dual responsibility and incentivizes high-quality public-health work.Methods Aligned with the national tertiary-level MCH-hospital performance appraisal standards and local project realities,we applied four industrial-en-gineering techniques—empirical time-and-motion estimation,classification,analogy and work-study—to convert every public-health project into quantifiable modules with pre-set labor-hour quotas.Bonuses were calculated under"more work,more pay"and"increment incentive"rules,while appraisal covered two dimensions:(ⅰ)project-specific indicators(coverage,timeliness,completeness)and(ⅱ)outcome evaluation(health impact and user satisfaction).Performance pay was then approved and dis-tributed to staff responsible for project management.Results Analysis of the 2022-2024 implementation period showed clear gains:① Work-force mobilization:departments managing MCH projects grew from 17 to 22 and staff from 22 to 73;all core pro-ject indicators improved significantly.② Service expansion:valid service volume generated by jurisdiction-level MCH project ac-tivities rose by 62.31%.Conclusion The scientific,standardized and operable performance and evaluation system for maternity and child projects developed in this study can help effectively improve the management efficiency of maternity and child projects in the jurisdiction and promote the high-quality development of the hospital.
6.Analysis of blood screening results for a case of HIV post-exposure prophylaxis failure: a 7-year follow-up study
Lilin WANG ; Fang ZHAO ; Lukun ZHANG ; Liqin HUANG ; Ran LI ; Rui ZHU ; Guochao WEI ; Jinfeng ZENG ; Rong XIA
Chinese Journal of Blood Transfusion 2025;38(11):1567-1572
Objective: To assess the impact of long-term antiretroviral therapy (ART) on human immunodeficiency virus (HIV) blood screening outcomes in post-exposure prophylaxis (PEP) failure cases through a longitudinal analysis of blood screening results over a 7-year period in a patient with HIV PEP failure. Methods: This study conducted 13 follow-up assessments for a high-risk individual who initiated ART shortly after exposure. The effectiveness of various blood screening methods, including immunological assays and nucleic acid testing (NAT), was analyzed. Blood samples were also tested with HIV RNA quantification testing, Western blot (WB) confirmation testing, chemiluminescence immunoassay (CLIA), and HIV rapid tests utilizing gold and selenium labels. A comprehensive analysis was performed to evaluate the changes in diagnostic capabilities of different testing methods for HIV biomarkers over an extended period following PEP failure. Results: The patient had two high-risk exposures: one day before ART initiation (BA1) and seven days preceding treatment (BA7). On the first day after the ART treatment (AA1), the HIV RNA concentration (viral load) was 9.07×10
copies/mL; by day five (AA5), the viral load decreased to 1.04×10
copies/mL. At day eleven (AA11), NAT and ELISA tests were both positive, with the WB result remaining indeterminate (gp160+). At day 48 (AA48), the S/CO value of the fourth generation ELISA reagent was 1.07, while results from a 6-sample pool and quantitative NAT were negative. However, a single sample NAT returned a positive result and WB tests indicated positivity for p17, p24, and gp160. At AA74, the quantitative NAT rebounded to 2.83×10
copies/mL, with positive NAT results for single and 6-sample pool NAT tests. The S/CO values of the imported and domestic ELISA reagents were 3.39 and 23.44, respectively. At AA201, 6-sample pool and quantitative NAT were negative again, while single sample NAT remained positive. From AA319 to AA2221, all NAT results have remained consistently below the minimum detection limit. At AA2221, S/CO values of the imported and domestic ELISA reagents were 3.47 and 23.44, respectively. Conclusion: The findings indicate that patients experiencing PEP failure after high-risk HIV exposure are at a higher risk of being missed by mixed-sample NAT pools and individual serological tests. Nonetheless, anti-HIV antibody levels are sustained at elevated values for an extended duration, underscoring antibody testing as an effective measure for blood screening.
8.Cost-utility analysis of HIV screening in blood donors using a decision-tree Markov model
Liqin HUANG ; Lilin WANG ; Linfen WU ; Jiahui ZUO ; Jinfeng ZENG
Chinese Journal of Blood Transfusion 2025;38(7):958-963
Objective: To develop a comprehensive health economics evaluation model for HIV blood screening using Markov modeling, so as to evaluate the quality-of-life adjustment years (QALYs) gained by transfusion recipients after implementation of blood HIV screening. Methods: Shenzhen Blood Center was selected as the validation case for model development. Based on historical HIV screening data of Shenzhen Blood Center and published literature, the health economics evaluation of donor HIV screening was performed using cost-utility analysis. The single factor sensitivity analysis was performed on parameters in the model. Results: 3.09 QALYs were gained for each transfusion recipient prevented from HIV infection. During 2020-2023, donor HIV screening at Shenzhen Blood Center saved 506.76 QALYs, and each QALY saved 182 900 yuan. Conclusion: From the perspective of long-term benefit of transfusion recipients, HIV screening of blood donors demonstrates high health and economic value.
9.Evaluation of donor ALT screening strategies based on random sampling simulation with large sample sizes
Liqin HUANG ; Yuanye XUE ; Le CHANG ; Lunan WANG ; Jinfeng ZENG
Chinese Journal of Blood Transfusion 2025;38(8):1094-1100
Objective: To comprehensively evaluate the current alanine aminotransferase (ALT) screening strategies and provide a basis for their optimization. Methods: ALT test results of 21 345 blood samples were collected from 33 blood collection institutions. Multiple probability distribution functions were employed to fit the data, and the akaike information criterion (AIC) was used to determine the optimal fitting model. Based on this model, 1 million random samplings were conducted to simulate the final ALT test results of blood donors under different ALT screening strategies, eligibility criteria, and pre-donation ALT detection deviations. A decision tree was subsequently constructed for health economic analysis. Results: The log-normal distribution with a mean of 2.96 and a variance of 0.65 provided the best fit for the data. When the eligibility criteria was 50 U/L and the pre-donation detection deviation was ±20%, not conducting pre-donation testing increased blood donation by 1.14%. When the pre-donation detection deviation was ±20% and the eligibility criteria was raised from 50 U/L to 100 U/L, conducting and not conducting pre-donation testing increased blood donation by 7.59% and 6.60%, respectively. With a eligibility criteria of 50 U/L and a pre-donation detection deviation of ±20%, 1.14% of eligible blood donors would be disqualified from donating blood. Health economic analysis showed that when the eligibility criteria was adjusted to 56 U/L or higher, not conducting pre-donation ALT testing was the dominant strategy; under other conditions, conducting pre-donation testing was the dominant strategy. Conclusion: The selection of ALT testing strategies is a complex process influenced by multiple factors, and it is necessary to adopt an appropriate ALT screening strategy based on specific testing circumstances.
10.Analysis on the current situation and prospect of chemiluminescence technology in blood screening
Jinfeng ZENG ; Haobiao WANG ; Yingnan DANG ; Liqin HUANG
Chinese Journal of Blood Transfusion 2025;38(8):1120-1126
Chemiluminescence immunoassay (CLIA), a non-radioactive immunoassay technology that has developed rapidly over the past three decades, has increasingly demonstrated its application value in blood screening due to its advantages such as high sensitivity, high specificity, rapid detection, and high degree of automation. This article systematically reviews the application status, technical characteristics, differences from traditional methods, influencing factors for promotion and application of CLIA in blood screening at home and abroad, and looks forward to its development prospects. Countries such as the United States, Germany, and Japan have widely adopted CLIA in the screening of pathogens like HBV, HCV, and HIV, predominantly using "1 CLIA test + 1 nucleic acid testing (NAT) test" model. Some regions have also expanded testing items to include anti-HBc and HTLV. In China, enzyme-linked immunosorbent assay (ELISA) combined with NAT remains the primary method. CLIA is still in the stage of detection performance comparison. However, domestic reagents have gradually been approved, and more enterprises are accelerating their layout in this field. CLIA is superior to ELISA in terms of sensitivity, detection range, and automation adaptability, which can reduce missed detection and shorten the window period. But it is limited by factors such as high cost, closed system characteristics, and domestic batch release supervision. In the future, CLIA is expected to complement existing technologies, expand the detection of emerging and re-emerging pathogens, and combine with fully automated assembly lines to improve screening quality, providing more comprehensive protection for clinical blood transfusion safety.

Result Analysis
Print
Save
E-mail