1.Compact Fundus Imaging System Using Shack-Hartmann Wavefront Sensing for High-speed Auto-focus
Zhe-Kai LIN ; Long CHEN ; Geng-Yong ZHENG ; Jin-Tian HUANG ; Jia-Xin DONG ; Shang-Pan YANG ; Wen-Zheng DING ; Ding-An HAN ; Xue-Hua WANG ; Ya-Guang ZENG
Progress in Biochemistry and Biophysics 2026;53(4):1076-1086
ObjectiveThe widespread adoption of portable fundus cameras for primary care and community screening is hindered by limitations in current autofocus(AF) technologies. Image-based methods relying on sharpness evaluation require iterative searches, resulting in slow convergence, while projection-based techniques are susceptible to optical artifacts and calibration errors. To address these challenges, this study introduces a novel AF system based on direct wavefront sensing, designed to deliver simultaneous high speed, high precision, and operational robustness within the compact form factor essential for portable ophthalmic devices. MethodsOur approach fundamentally reimagines the AF process by directly measuring the ocular wavefront aberration. We developed a custom portable fundus camera integrating a miniaturized Shack-Hartmann wavefront sensor (SHWS) into the optical path. An 850 nm laser diode projects a point source onto the retina via oblique illumination to minimize corneal reflections. Light scattered from this spot carries the eye’s refractive error through the imaging optics and is directed to the SHWS, positioned at a plane optically conjugate to the primary color CMOS imaging sensor. A microlens array within the SHWS samples the incident wavefront, generating a pattern of focal spots on a CCD. Real-time centroid analysis of these spots provides a map of local wavefront slopes. These measurements are processed through a singular value decomposition (SVD) algorithm to fit a Zernike polynomial basis set, enabling real-time reconstruction of the wavefront phase. The defocus component (S) is extracted from the second-order Zernike coefficients, providing a direct, quantitative measure of the refractive error in diopters. This value serves as a precise error signal in a closed-loop control system, which commands a voice-coil actuated focusing lens to its null position in a single, deterministic step, eliminating the need for iterative search algorithms. ResultsComprehensive evaluation demonstrated the system’s high performance. Testing on a calibrated model eye (OEMI-7) established a highly linear relationship between the computed defocus S and the focusing lens position across a ±20 Diopter (D) compensation range, achievable within a 5 mm mechanical travel. The system achieved a focusing precision of 0.08 D, corresponding to an 18-fold improvement over a conventional projection spot-size method tested under identical conditions. The total focus acquisition time, encompassing wavefront measurement, computation, and lens actuation, averaged under 0.5 s. Clinical validation with 25 human volunteers (50 eyes, refractive range -15 D to +10 D) confirmed practical efficacy. The wavefront-sensing AF succeeded in 92% of attempts with a mean time of 0.5 s, substantially outperforming a projection-based benchmark which achieved only a 32% success rate with an average time of 4.25 s. The system provided instantaneous directional guidance and maintained stability during minor ocular movements. Objective assessment of image quality, via amplitude contrast of retinal vasculature, showed consistent and significant enhancement following AF correction across the entire tested diopter range. ConclusionThis work successfully implements and validates a direct wavefront-sensing autofocus paradigm for portable fundus cameras. By directly quantifying and compensating for the optical defocus aberration, this method bypasses the fundamental limitations of image-processing and projection-based techniques, enabling rapid, precise, and deterministic diopter compensation. The developed system delivers an exceptional combination of a wide operational range (±20 D), high accuracy (0.08 D), fast convergence (0.5 s), and a compact physical footprint. This technology provides a practical and high-performance focusing solution capable of enhancing the reliability, throughput, and diagnostic utility of portable retinal imaging in large-scale screening applications. Future efforts will be directed towards system cost optimization and performance adaptation for diverse ocular conditions.
2.Reactive and Enzyme-activated Probe Strategies for Imaging Acute Kidney Injury
Ru-Long CHEN ; Ting-Fei XIE ; Jin-Xin ZHANG ; Jia-Ting CHEN ; Jie LI ; Peng-Fei ZHANG ; Ji-Hong CHEN ; Lin-Tao CAI
Progress in Biochemistry and Biophysics 2026;53(6):1622-1637
Acute kidney injury (AKI) is a prevalent and life-threatening clinical syndrome characterised by a rapid decline in renal function and diverse pathological etiologies. The condition has been demonstrated to be associated with elevated mortality rates and an increased risk of progression to chronic kidney disease. At present, clinicians depend heavily on conventional functional markers, such as serum creatinine and urine output, for the diagnosis and staging of the disease. It is evident that these conventional indicators characteristically manifest a considerable temporal delay and only undergo modification subsequent to considerable tissue damage. This severely restricts the timeframe for early detection and timely therapeutic intervention. Furthermore, standard markers fail to provide specific biological information regarding the underlying cellular injury mechanisms. The utilisation of advanced probe technologies in molecular imaging offers a robust alternative to overcome these inherent diagnostic limitations.This comprehensive review systematically evaluates recent progress in the design and application of two primary categories of molecular imaging tools for acute kidney disease, specifically reactive probes and enzyme-activated probes. Reactive probes are engineered to specifically interact with redox-active chemical species, including hydrogen peroxide, peroxynitrite, hypochlorous acid, and sulfur dioxide. Because oxidative stress constitutes a primary early event in acute renal tubular damage, these probes enable researchers and clinicians to visualize early cellular injury and radical accumulation well before global renal functional decline becomes evident. We discuss the application of these reactive probes across multiple imaging modalities including fluorescence imaging, magnetic resonance imaging (MRI), positron emission tomography (PET), and photoacoustic techniques. Photoacoustic imaging combines high spatial resolution with deep tissue penetration and has successfully demonstrated the ability to provide diagnostic alerts up to 12 h before any detectable rise in serum creatinine levels. Additionally, specific reactive probes have shown promising translational potential when tested by high-throughput screening in clinical human urine samples. Enzyme-activated probes target the specific catalytic activity of disease-relevant enzymes. These include well-documented renal tubular structural biomarkers such as NAG, GGT, and ALP, along with apoptosis-related caspases and specific nitroreductases. By responding only to enzymatic cleavage, these tools provide highly specific and pathology-directed imaging readouts. Recent structural design strategies in this field have advanced significantly beyond single-enzyme detection. Researchers are now focusing on sophisticated dual-target recognition to minimize background noise, multimodal integration to cross-validate imaging signals, and theranostic applications where probes simultaneously deliver diagnostic feedback and therapeutic agents to injured tissues. Nanotechnology serves as a fundamental enabler for realizing these advanced probe functions. By precisely optimizing nanoparticle parameters such as hydrodynamic size, surface charge, and targeting ligands, researchers can achieve amplified signal output, highly precise kidney delivery, and protection against premature degradation in the systemic circulation. For example, modifying surface charges can significantly enhance the active uptake of nanoprobes by damaged renal tubular epithelial cells.While preclinical probe development has progressed rapidly, moving these technologies into routine clinical practice remains a major challenge. We analyze the translational feasibility and current obstacles from biological, technological, and regulatory perspectives. Although biological targets such as KIM-1, FAP, and ALP have been validated in extensive patient cohorts, practical barriers severely limit their immediate clinical application. These obstacles involve complex changes in in vivo pharmacokinetics. During an acute injury episode, the extreme drop in the glomerular filtration rate alters probe clearance and can cause unwanted systemic accumulation or confusing background imaging signals. Other major hurdles include a lack of comprehensive long-term toxicity data and the absence of standardized manufacturing protocols to ensure batch-to-batch consistency. Future successful translation will require rigorous multi-center clinical studies to confirm the true diagnostic value of these probes over traditional markers. Researchers must also establish strict standardization of imaging procedures and comprehensive safety evaluations. Ultimately, this review provides a thorough reference framework for designing clinically translatable molecular probes and building a precision diagnostic imaging system for acute kidney injury.
3.Construction of A Nomogram Prognostic Model Based on Pretreatment Inflammatory Indicator for Esophageal Squamous Cell Carcinoma Patients Treated with Radical Radiotherapy
Shenbo FU ; Long JIN ; Jing LIANG ; Junjun GUO ; Yu CHE ; Chenyang LI ; Yong CHEN
Cancer Research on Prevention and Treatment 2025;52(2):142-150
Objective To describe the significance of the pretreatment inflammatory indicators in predicting the prognosis of patients with esophageal squamous cell carcinoma (ESCC) after undergoing radical radiotherapy. Methods The data of 246 ESCC patients who underwent radical radiotherapy were retrospectively collected. Receiver operating characteristic (ROC) curves were drawn to determine the optimal cutoff values for platelet-lymphocyte ratio (PLR), neutrophil-lymphocyte ratio (NLR), and systemic immune-inflammation index (SII). The Kaplan-Meier method was used for survival analysis. We conducted univariate and multivariate analyses by using the Cox proportional risk regression model. Software R (version 4.2.0) was used to create the nomogram of prognostic factors. Results The results of the ROC curve analysis showed that the optimal cutoff values of PLR, NLR, and SII were 146.06, 2.67, and 493.97, respectively. The overall response rates were 77.6% and 64.5% in the low and high NLR groups, respectively (P<0.05). The results of the Kaplan-Meier survival analysis revealed that the prognosis of patients in the low PLR, NLR, and SII group was better than that of patients in the high PLR, NLR, and SII group (all P<0.05). The results of the multivariate Cox regression analysis showed that gender, treatment modalities, T stage, and NLR were independent factors affecting the overall survival (OS). In addition, T stage and NLR were independent factors affecting the progression-free survival (PFS) (all P<0.05). The nomogram models of OS and PFS prediction were established based on multivariate analysis. The C-index values were 0.703 and 0.668. The calibration curves showed excellent consistency between the predicted and observed OS and PFS. Conclusion The pretreatment values of PLR, NLR, and SII are correlated with the prognosis of patients with ESCC who underwent radical radiotherapy. Moreover, NLR is an independent factor affecting the OS and PFS of ESCC patients. The NLR-based nomogram model has a good predictive ability.
4.Design and application of intelligent monitoring platform for adverse drug reactions
Guang-hua CHEN ; Jin XU ; Xi-long FENG ; Yong GAO ; Pei-yun NI ; Hua ZHU
Chinese Medical Equipment Journal 2025;46(9):33-38
Objective To design an intelligent monitoring platform for adverse drug reactions(ADRs)to solve the problems of the traditional ADR monitoring mode.Methods The ADR intelligent monitoring platform was designed based on artificial intelligence and big data technologies,which was developed with Browser/Server(B/S)architecture,C#programming language and.NET development tool.There were five functional modules involved in the platform for ADR knowledge base,monitoring rule setting,intelligent monitoring,report management and statistical analysis.Results The platform realized the full-process management of ADR intelligent monitoring,reporting,review and statistical analysis,which enhanced the ADR report in quantity,quality and timeliness.Conclusion The platform contributes to improving the monitoring of ADR and patient medication safety.[Chinese Medical Equipment Journal,2025,46(9):33-38]
6.Investigation and analysis of hearing impaired children's ability to use hearing equipment
Shuang LIANG ; Qingqing LIU ; Huimin TAN ; Nan ZHAO ; Xi CHEN ; Wenjing SHI ; Yanfang MA ; Wei BAO ; Xingcheng WANG ; Jin LI ; Liping SHI ; Jiang LONG
Journal of Audiology and Speech Pathology 2025;33(4):359-362
Objective To investigate the status of hearing impaired children's hearing device independence skills,and to explore the ways to improve their self-use of hearing equipment.Methods This study surveyed 64 re-habilitation teachers and 411 parents of children with hearing impairment aged 0-12 years.Through face-to-face or remote telephone interview,3 good habits(A asking parents for advice before removing the HA,B putting the de-vice into a moisture-proof box after removing it,C bringing batteries to school and knowing where are them)and 3 key abilities[D wearing the device independently,E replacing the battery independently,and F independently handle foreign bodies in the ear mold(Fa)and water vapor(Fb)]was investigated.The age when mastering skills or de-veloping habits difference of hearing impaired children in different groups were compared.Results ① The ratio of ability D in the bilateral CI group and the bilateral HA group of preschool children was 30.97%and 18.57%respec-tively.Among elementary school children,85.29%and 90.70%had this ability respectively.② The ratio of ability E in the bilateral CI group,the bilateral HA group and the bimodel group were 11.50%,15.71%and 16.49%,re-spectively.Among elementary school children,64.71%,53.49%and 68.52%had this ability,respectively.③Among preschool children,there was no statistical difference in age when different equipment groups developed the three good habits and acquired ability D and E(P>0.05).④ Among primary school children,there was a statisti-cal difference in the age when different equipment groups formed habit A(P<0.05),and the age when double CI group had this ability was slightly earlier than the double HA group.There was no significant difference in other abilities among age groups(P>0.05).Conclusion The age at which hearing impaired children develop the three good habits precedes the age at which they master the key skills,which accords with the law of skill acquisition and development of ordinary children.Corresponding teaching process should be based on the age and ability of hearing-impaired children without considering the type of equipment.
7.Formulation and Explanation of the Standard for Drug Quality Problems Handling
Jiadan YANG ; Yongqing CHEN ; Long MENG ; Jin LU ; Zilang LUO ; Feng QIU ; Jiancun ZHEN
Herald of Medicine 2025;44(5):708-711
Drug quality problems seriously threaten the life and health of patients,drug quality problems handling is an important part of pharmaceutical management in medical institutions,and strengthening the management of drug quality problems in medical institutions can provide a strong guarantee for drug safety of patients.This standard was compiled by the Pharmaceutical Affairs Commission of the Chinese Hospital Association,and the process included problems identification,framework development,manuscript writing,opinions gathering,expert argumentation and deliberation,and standards development.The standard regulates the basic requirements,coping strategies,quality control and continuous improvement of drug quality problems handling in medical institutions.This article elaborates on the methods and contents of formulating standards for drug quality problems handling,to pro-vide reference and inspiration for medical institutions to carry out drug quality problems handling.
8.Research on the design and application value of a simulation system for surgical operation based on virtual reality technique and intelligent scoring function
Long LI ; Qingbo WANG ; Yubo LIANG ; Jin LI ; Wanling LUO ; Xingming CHEN ; Yang DUAN ; Zhiyi TANG ; Shengjie NIE ; Yang KE
China Medical Equipment 2025;22(5):28-32
Objective:To design a set of simulation system for surgical operation based on virtual reality(VR)technique and intelligent scoring functions,so as to assess its clinical application effect.Methods:The Digital Imaging and Communications in Medicine(DICOM)images of typical patients were collected.Materialise Interactive Medical Image Control System(MIMICS)software was adopted to reconstruct the three-dimensional(3D)model of diseased organs.Surgical instrument models were constructed by using 3D Max software.Unity 3D software was adopted to construct simulation system for surgical operation with VR+intelligent scoring.A total of 40 surgical resident physicians,who were employed with 3 years since 2019 in The Second Affiliated Hospital of Kunming Medical University,were selected.They were divided into observation group and control group,with 20 cases in each group.The observation group used simulation system for surgical operation to conduct intelligent scoring for cholecystectomy under laparoscope,and the control group used conventional scoring for surgical operation.The scores of surgical operation and test between the two groups were compared.Results:The mean value of surgical operation time of the observation group was(1.72±0.41)h,and the average incidence of complication was(0.03±0.02)%,both of them of the observation group were significantly lower than those of the control group[(2.25±0.42)h and(0.05±0.03)%].The differences of them between two groups were statistically significant(t=9.00,4.08,P<0.05).The test scores of surgical operation of the observation group was also significantly higher than that of the control group(t=5.26,P<0.001).Conclusion:The developed simulation system for surgical operation with VR+intelligent scoring can significantly enhance users'surgical operation skills and improve learning outcomes,which has favorable prospects in future applications.
9.Clinical features of dystonia in patients with different types of atypical Parkinson syndrome
Dongdong WU ; Jing HE ; Yunfei LONG ; Huijing LIU ; Wei DU ; Huimin CHEN ; Shuhua LI ; Ying JIN ; Xinxin MA ; Wen SU ; Haibo CHEN
Chinese Journal of General Practitioners 2025;24(4):465-470
Objective:To evaluate the clinical features of dystonia in patients with different types of atypical Parkinson syndrome (APS).Methods:A total of 104 patients with APS admitted in the Department of Neurology, Beijing Hospital from January 2015 to June 2023 were enrolled in the study, including 57 cases of multiple system atrophy (MSA), 38 cases of progressive supranuclear palsy (PSP) and 9 cases of corticobasal degeneration (CBD). Among 104 cases there were 63 males (60.6%), the mean age of patients was (62.3±8.9) years (54 to 73 years). The sex, age at onset, disease duration, first symptom, clinical features of dystonia and other neurological signs, response to levodopa therapy, numbers of Hoehn & Yahr scale≥3 after 3 years of disease, and MRI findings were documented in patients with different type APS.Results:The overall frequency of dystonia in this series was 45.2%(47/104), and 33.3% (19/57) for MSA group, 50.0% (19/38) for PSP group, 9/9 for CBD group. The types of dystonia were anterocollis, retrocollis, blepharospasm, oromandibular, foot/limb dystonia, Pisa syndrome and myoclonus. In all 47 cases presenting dydtonia, dystonia was not the first complaint and it did not respond to levodopa therapy.Conclusion:In this series of atypical Parkinson syndrome, dystonia is a common feature of the disease, while it is not the first symptom at disease onset, and usually does not respond to levodopa therapy.
10.Clinical characteristics of 10 cases of immune checkpoint inhibitor-related diabetes mellitus and literature review
Wen-Wen GONG ; Shu LI ; Yu-Long CHEN ; Li ZANG ; Jin DU ; Xian-Ling WANG ; Zhao-Hui LYU ; Qing-Hua GUO
Medical Journal of Chinese People's Liberation Army 2025;50(9):1103-1109
Objective To analyze the clinical characteristics,treatment,and prognosis of immune checkpoint inhibitor-related diabetes mellitus(ICI-DM).Methods The clinical characteristics,laboratory examinations,treatment regimens,and follow-up outcomes of 10 ICI-DM patients who were diagnosed and treated in the First Medical Center of Chinese PLA General Hospital between July 2019 and December 2024 were retrospectively analyzed.Relevant literatures were retrieved from domestic and foreign databases such as PubMed,CNKI,and VIP.The clinical characteristics of ICI-DM were summarized based on the literature results.Results All 10 patients were PD-1 inhibitor users,including 5 males and 5 females,with a median age of 54.5(51.3,64.0)years and a body mass index(BMI)of(22.0±2.15)kg/m2.Among them,9 cases(90.0%)were fulminant type 1 diabetes mellitus(FT1DM);9 cases(90.0%)had a severity of adverse events reaching grade 3-4 according to the Common Terminology Criteria for adverse events(CTCAE).The median time from PD-1 inhibitor treatment to the occurrence of the classic diabetes symptoms referred to as"three more and one less"(polyuria,polydipsia,polyphagia,and weight loss)in all patients was 145.5(110.5,204.8)days,and the medication duration was 6.0(4.3,7.8)cycles.The average blood glucose level of the 10 patients at the time of consultation was 25.3(10.0-41.4)mmol/L,and the glycated hemoglobin(HbA1c)level was 8.0%(6.6%-10.9%).Eight patients had fasting and 2-hour C-peptide levels<0.1 ng/ml(fasting C-peptide from<0.010 to 0.067 ng/ml,2-hour C-peptide from<0.010 to 0.077 ng/ml).Nine of the 10 patients were negative for diabetes autoantibodies,while 1 was not tested.All 10 patients were successfully treated with insulin and other therapies.During the follow-up after discharge,all patients still relied on insulin treatment,and no significant recovery of pancreatic islet β cell function was observed compared with that at discharge.Literature review revealed that ICI-DM was more common in PD-1 inhibitor users,with clinical mainly manifested as diabetic ketoacidosis(DKA)(65.4%)and diabetic ketosis(13.1%).Patients had severely impaired pancreatic islet function and required long-term insulin treatment,and some cases were complicated by thyroid or pituitary dysfunction.Conclusions ICI-DM typically presents as FT1DM,often manifesting with DKA or diabetic ketosis at onset.It is characterized by severe and irreversible loss of pancreatic islet function,necessitating lifelong insulin therapy.To enable early detection and prompt treatment,close monitoring of blood glucose is essential during ICI treatment.

Result Analysis
Print
Save
E-mail