1.Correction to: A Virtual Reality Platform for Context-Dependent Cognitive Research in Rodents.
Xue-Tong QU ; Jin-Ni WU ; Yunqing WEN ; Long CHEN ; Shi-Lei LV ; Li LIU ; Li-Jie ZHAN ; Tian-Yi LIU ; Hua HE ; Yu LIU ; Chun XU
Neuroscience Bulletin 2025;41(5):932-932
2.Expert consensus on evaluation index system construction for new traditional Chinese medicine(TCM) from TCM clinical practice in medical institutions.
Li LIU ; Lei ZHANG ; Wei-An YUAN ; Zhong-Qi YANG ; Jun-Hua ZHANG ; Bao-He WANG ; Si-Yuan HU ; Zu-Guang YE ; Ling HAN ; Yue-Hua ZHOU ; Zi-Feng YANG ; Rui GAO ; Ming YANG ; Ting WANG ; Jie-Lai XIA ; Shi-Shan YU ; Xiao-Hui FAN ; Hua HUA ; Jia HE ; Yin LU ; Zhong WANG ; Jin-Hui DOU ; Geng LI ; Yu DONG ; Hao YU ; Li-Ping QU ; Jian-Yuan TANG
China Journal of Chinese Materia Medica 2025;50(12):3474-3482
Medical institutions, with their clinical practice foundation and abundant human use experience data, have become important carriers for the inheritance and innovation of traditional Chinese medicine(TCM) and the "cradles" of the preparation of new TCM. To effectively promote the transformation of new TCM originating from the TCM clinical practice in medical institutions and establish an effective evaluation index system for the transformation of new TCM conforming to the characteristics of TCM, consensus experts adopted the literature research, questionnaire survey, Delphi method, etc. By focusing on the policy and technical evaluation of new TCM originating from the TCM clinical practice in medical institutions, a comprehensive evaluation from the dimensions of drug safety, efficacy, feasibility, and characteristic advantages was conducted, thus forming a comprehensive evaluation system with four primary indicators and 37 secondary indicators. The expert consensus reached aims to encourage medical institutions at all levels to continuously improve the high-quality research and development and transformation of new TCM originating from the TCM clinical practice in medical institutions and targeted at clinical needs, so as to provide a decision-making basis for the preparation, selection, cultivation, and transformation of new TCM for medical institutions, improve the development efficiency of new TCM, and precisely respond to the public medication needs.
Medicine, Chinese Traditional/standards*
;
Humans
;
Consensus
;
Drugs, Chinese Herbal/therapeutic use*
;
Surveys and Questionnaires
3.Clinical pathway for integrated traditional Chinese and Western medicine in the diagnosis and treatment of acute pancreatitis
Yuan ZHANG ; Hao WANG ; Haiyan YIN ; Shengwei JIN ; Bangjiang FANG ; Guiwei LI ; Xijing ZHANG ; Hongmei GAO ; Donghao WANG ; Changsong WANG ; Keliang XIE ; Lai JIANG ; Yan QU ; Zhaocai ZHANG ; Jianying KAN ; Daihua YU ; Junling LIU ; Jun LI ; Weiwei AN ; Yong CHEN ; Jianbo YU
Chinese Journal of Integrated Traditional and Western Medicine in Intensive and Critical Care 2025;32(3):257-261
Acute pancreatitis(AP)is a frequently encountered acute abdominal syndrome in clinical settings,and the integrated model of traditional Chinese and Western medicine(TCM-WM)has demonstrated notable advantages in the diagnosis and treatment of AP.To systematize and standardize clinical practices related to develop clinical pathway for integrated TCM-WM diagnosis and treatment of AP,which enhances the efficiency and quality of patient care.This pathway focuses on AP,a common acute and life-threatening disease within the digestive system,and outlines that the central pathological mechanism involves pancreatic injury and localized inflammation resulting from the abnormal activation of pancreatic enzymes.It has the characteristics of rapid onset,multiple causes,and complex manifestations.Severe cases can be life-threatening.At present,conventional treatments encompass a diverse range of modalities.Moreover,traditional Chinese medicine(TCM)holds distinct advantages in alleviating relevant symptoms,and TCM-WM is gaining increasing prevalence.To enhance the standardization and consistency of diagnostic and therapeutic practices,this clinical pathway clearly delineates the target patient population,which includes individuals diagnosed with abdominal pain disorder according to TCM and with AP in accordance with WM criteria,as well as the corresponding inclusion standards.The diagnostic framework integrates both TCM and WM guidelines,and further incorporates disease staging,severity grading,and syndrome differentiation to support a comprehensive and integrated diagnostic strategy.The treatment integrates approaches from both TCM and WM.Within the WM framework,interventions consist of basic supportive care,infection control,nutritional support,and the management of complications.In the context of TCM,the protocol includes syndrome differentiation and corresponding therapeutic strategies(Distinct syndrome patterns are identified and managed during the acute and convalescent phases),such as acupuncture and retention enema.This clinical pathway addresses multiple key components,including preventive strategies,post-treatment follow-up,criteria for evaluating therapeutic efficacy,admission and discharge,admission examination protocols,discharge criteria,and the rationale for deviations or withdrawal from the pathway.It is designed to provide a systematic and standardized reference framework for relevant clinical practices.
4.Association between occupational stress and health-related quality of life among grassroots medical personnels
JIN Yi ; QU Hongbo ; YANG Feifei ; LU Xiaomiao ; SHI Yu
Journal of Preventive Medicine 2025;37(7):654-658
Objective:
To investigate the association between occupational stress and health-related quality of life (HRQoL) among grassroots medical personnels, so as to provide the reference for improving their physical and mental well-being.
Methods:
From March to May 2024, medical staff from nine street community health service centers in Liangxi District, Wuxi City, Jiangsu Province were selected by a convenient sampling method. Basic information was collected through questionnaire surveys. Occupational stress was assessed using the Core Occupational Stress Measurement Scale. Health utility value and the Visual Analog Scale (EQ-VAS) score were investigated using the European Quality of Life Five-Dimension Five-Level (EQ-5D-5L) questionnaire. The association between occupational stress and HRQoL was analyzed using multiple linear regression model.
Results:
A total of 909 individuals were surveyed, including 141 males (15.51%) and 768 females (84.49%). The average occupational stress score was (24.41±9.45) points. The average health utility value was (0.96±0.07), with 372 individuals (40.92%) experiencing health problems in at least one dimension. The primarily problems were pain/discomfort and anxiety/depression, with 249 (27.39%) and 265 (29.15%) individuals, respectively. The average EQ-VAS score was (86.62±13.84) points. Multiple linear regression analysis revealed that occupation (nurses, β'=0.101; pharmacists, β'=0.101; medical technicians, β'=0.090), professional title (intermediate, β'=-0.079; associate senior, β'=-0.081; senior, β'=-0.101), and occupational stress (β'=-0.288) were influencing factors for health utility value. Occupation (nurses, β'=0.087; pharmacists, β'=0.146; medical technicians, β'=0.073) and occupational stress (β'=-0.226) were influencing factors for EQ-VAS score. After adjusting for variables such as gender, age, educational level, occupation, professional title, work experience, and monthly income, grassroots medical personnels with higher occupational stress score had lower health utility values (β'=-0.296) and EQ-VAS score (β'=-0.237).
Conclusions
Occupational stress can reduce the HRQoL among grassroots medical personnels. It is recommended to regularly assess occupational stress levels and intervene early to address their psychological and physical health issues.
5.Cost-effectiveness of angiographic quantitative flow ratio-guided coronary intervention: A multicenter, randomized, sham-controlled trial.
Yanyan ZHAO ; Changdong GUAN ; Yang WANG ; Zening JIN ; Bo YU ; Guosheng FU ; Yundai CHEN ; Lijun GUO ; Xinkai QU ; Yaojun ZHANG ; Kefei DOU ; Yongjian WU ; Weixian YANG ; Shengxian TU ; Javier ESCANED ; William F FEARON ; Shubin QIAO ; David J COHEN ; Harlan M KRUMHOLZ ; Bo XU ; Lei SONG
Chinese Medical Journal 2025;138(10):1186-1193
BACKGROUND:
The FAVOR (Comparison of Quantitative Flow Ratio Guided and Angiography Guided Percutaneous Intervention in Patients with Coronary Artery Disease) III China trial demonstrated that percutaneous coronary intervention (PCI) lesion selection using quantitative flow ratio (QFR) measurement, a novel angiography-based approach for estimating fractional flow reserve, improved two-year clinical outcomes compared with standard angiography guidance. This study aimed to assess the cost-effectiveness of QFR-guided PCI from the perspective of the current Chinese healthcare system.
METHODS:
This study is a pre-specified analysis of the FAVOR III China trial, which included 3825 patients randomized between December 25, 2018, and January 19, 2020, from 26 centers in China. Patients with stable or unstable angina pectoris or those ≥72 hours post-myocardial infarction who had at least one lesion with a diameter stenosis between 50% and 90% in a coronary artery with a ≥2.5 mm reference vessel diameter by visual assessment were randomized to a QFR-guided strategy or an angiography-guided strategy with 1:1 ratio. During the two-year follow-up, data were collected on clinical outcomes, quality-adjusted life-years (QALYs), estimated costs of index procedure hospitalization, outpatient cardiovascular medication use, and rehospitalization due to major adverse cardiac and cerebrovascular events (MACCE). The primary analysis calculated the incremental cost-effectiveness ratio (ICER) as the cost per MACCE avoided. An ICER of ¥10,000/MACCE event avoided was considered economically attractive in China.
RESULTS:
At two years, the QFR-guided group demonstrated a reduced rate of MACCE compared to the angiography-guided group (10.8% vs . 14.7%, P <0.01). Total two-year costs were similar between the groups (¥50,803 ± 21,121 vs . ¥50,685 ± 23,495, P = 0.87). The ICER for the QFR-guided strategy was ¥3055 per MACCE avoided, and the probability of QFR being economically attractive was 64% at a willingness-to-pay threshold of ¥10,000/MACCE avoided. Sensitivity analysis showed that QFR-guided PCI would become cost-saving if the cost of QFR were below ¥3682 (current cost: ¥3800). Cost-utility analysis yielded an ICER of ¥56,163 per QALY gained, with a 53% probability of being cost-effective at a willingness-to-pay threshold of ¥85,000 per QALY gained.
CONCLUSION:
In patients undergoing PCI, a QFR-guided strategy appears economically attractive compared to angiographic guidance from the perspective of the Chinese healthcare system.
TRIAL REGISTRATION
ClinicalTrials.gov , NCT03656848.
Humans
;
Cost-Benefit Analysis
;
Percutaneous Coronary Intervention/methods*
;
Male
;
Female
;
Coronary Angiography/methods*
;
Middle Aged
;
Aged
;
Coronary Artery Disease/surgery*
;
Quality-Adjusted Life Years
;
Fractional Flow Reserve, Myocardial/physiology*
6.The impact of coexisting choroidal detachment on surgical prognosis in macular hole retinal detachment associated with high myopia
Yi CAI ; Mingwei ZHAO ; Jianhong LIANG ; Hong YIN ; Wenzhen YU ; Xuan SHI ; Jinfeng QU ; Yong CHENG ; Jing HOU ; Heng MIAO ; Enzhong JIN
Chinese Journal of Ocular Fundus Diseases 2025;41(2):89-97
Objective:To investigate the clinical characteristics of patients with high-myopia macular hole retinal detachment (MHRD) combined with choroidal detachment and to preliminarily analyze factors associated with postoperative hole closure.Methods:A retrospective clinical case series study. A total of 68 patients with high myopia (68 eyes) with MHRD diagnosed by Department of Ophthalmology, Peking University People’s Hospital from January 2019 to April 2024 were included in this study. Among them, there were 14 males (14 eyes) and 54 females (54 eyes). The mean age was (61.10±9.66) years. All eyes were treated with pars plana vitrectomy (PPV) combined with silicone oil or gas filling. Best corrected visual acuity (BCVA), intraocular pressure, and B-mode ultrasonography were performed. The BCVA test was performed using the Snellen visual acuity chart, which was statistically converted to logarithm of the minimum angle of resolution (logMAR) visual acuity. The range of choroidal detachment was defined according to the number of involved quadrants observed in B-mode ultrasound or surgery, which was divided into 1 to 4 quadrants. Axial length (AL) was measured under retinal reattachment. In 68 eyes, there were 17 eyes with choroidal detachment and 51 eyes without choroidal detachment, respectively. There were 17 eyes with choroidal detachment, and the detachment range involved 1, 2, 2 and 12 eyes in 1, 2, 3 and 4 quadrants, respectively. During operation, 13% C 3F 8 was filled in 2 eyes, all of which were not complicated with choroidal detachment. 66 eyes were filled with silicone oil. According to whether the patients were complicated with choroidal detachment, the patients were divided into the group without choroidal detachment and the group with choroidal detachment. Independent sample t test, Welch two-sample t test or Mann-Whitney U test were used for comparison between groups. Generalized linear regression and logistic regression were used to analyze the relationship between the aperture size of postoperative unclosed holes and the closed hole after surgery and clinical factors. Results:At 3 months after surgery, the logMAR BCVA of the affected eye was 1.29±0.43, with a preoperative to postoperative difference ranging from -1.60 to 0.70 (-0.51±0.51) logMAR units. The AL ranged from 26.6 to 34.3 (29.60±2.12) mm. Among 68 eyes, macular hole of 37 (54.4%, 37/68) eyes were open and 31 (45.6%, 31/68) eyes were closed, respectively. The hole diameter of the open eye was (753±424) μm. There was no significant difference in age, course of disease and AL between the two groups ( W=412.0, 477.5, 427.0; P>0.05). Before operation, BCVA in patients with choroidal detachment was worse ( W=257.5) and intraocular pressure was lower ( t=4.051) in patients with choroidal detachment compared with those without choroidal detachment, with statistical significance ( P<0.05). At 3 months after surgery, BCVA in patients with choroidal detachment was significantly worse than that in patients without choroidal detachment, with statistical significance ( W=284.0, P<0.05). There were no significant differences in logMAR BCVA difference ( t=0.616) and macular hole closure rate ( χ 2=0.000) before and after surgery ( P>0.05). The reoperation rate of retinal detachment due to persistent or recurrent retinal detachment was significantly higher in the group with choroid detachment than in the group without choroid detachment, and the difference was statistically significant (odds ratio=6.424, P<0.05). Logistic regression analysis showed that young age was significantly correlated with macular hole closure failure after surgery ( β=0.077, P=0.015). There was no correlation between AL, duration of disease, BCVA before surgery, intraocular pressure, wether combined with choroid detachment range and postoperative hole closure ( β=-0.072, 0.000, 0.672, -0.085, -0.391; P>0.05). Conclusions:Concomitant choroidal detachment adversely affected on both pre-operative and post-operative visual acuity in high myopia MHRD. It is closely associated with the risk of recurrent retinal detachment and the needs of multiple operations, but has no significant effect on hole closure rate. Lower age of onset may be a risk factor for macular hole closure.
7.Expert consensus on infection prevention and control of Creutzfeldt-Jakob disease in medical institutions
Tianxiang GE ; Yangyang JIA ; Chunhui LI ; Jianrong HUANG ; Xiujuan MENG ; Xiaodong GAO ; Jingping ZHANG ; Fu QIAO ; Lijuan XIONG ; Hui LIANG ; Wei LI ; Haiyan LOU ; Wenjuan WU ; Tianxin XIANG ; Jiansen CHEN ; Biao ZHU ; Kaijin XU ; Zhihui ZHOU ; Hongliu CAI ; Meihong YU ; Yan ZHANG ; Yanwan SHANGGUAN ; Haiting FENG ; Hangping YAO ; Lei GUO ; Tieer GAN ; Weihong ZHANG ; Jimin SUN ; Ye LU ; Qun LU ; Meng CAI ; Jin SHEN ; Yunsong YU ; Anhua WU ; Liu-yi LI ; Tingting QU
Chinese Journal of Infection Control 2025;24(4):437-450
Creutzfeldt-Jakob disease(CJD)is a rapidly progressive and fatal neurodegenerative disorder caused by prions,with certain infectivity and iatrogenic transmission risks.With the rapid progress and application of new dia-gnostic biomarkers and detection methods,as well as the construction and improvement of surveillance and reporting systems,the detection of CJD in patients domestically and internationally has shown an increasing trend year by year.Due to its long incubation period and heterogeneity of early symptoms,early identification and diagnosis of the disease is difficult,increasing the risk of transmission within medical institutions.Currently,there is a lack of con-sensus on the infection prevention and control of CJD.In order to timely identify and diagnose CJD as well as effec-tively block its transmission in medical institutions,this consensus summarizes 15 clinical concerns and formulates 24 specific recommendations based on the latest domestic and international research findings and clinical evidence,as well as combines with clinical practice,aiming to standardize healthcare-associated infection prevention and control measures for CJD and reduce its transmission risk in medical institutions.
8.Necessity of blood hemocompatibility evaluation in medical devices with indirect contact with blood
Chun-xia QIAO ; Qiu-jin QU ; Li HOU ; Zeng-lin ZHAO ; Xiang-yu CHU ; Xiao-xia SUN
Chinese Medical Equipment Journal 2025;46(8):44-49
Objective To study the need for blood compatibility evaluation of medical devices that come into indirect contact with blood in order to accurately evaluate the risk of their interaction with blood.Methods Seven medical devices with indirect contact with blood were selected as samples including extension tubes of central venous catheters,port bodies of implantable drug delivery devices,infusion sets,receiving lines of dialysis equipment,auxiliary lines of left ventricular assist devices,blood monitors and catheter holders,with high-density polyethylene as the negative control,glass beads as the positive control and blank whole blood or plasma for the blank control.Partial thromboplastin time(PTT)test,platelet count test and hematology test(white blood cell and red blood cell count)were performed by direct contact method and indirect contact method,respectively.In the direct contact method,whole blood or plasma was in direct contact with the sample;while in the indirect contact method,whole blood or plasma was not in direct contact with the extraction solution,with no direct contact with the sample.Results With the indirect contact method the ratios(expressed as a percentage)of the PTT,platelate,WBC and RBC counts of the samples,positive and negative controls to those of the blank control were all higher than those with the direct contact method,and the indirect contact method had the sensitivity lower than that of the direct contact method.Conclusion Medical devices indirectly contacting blood have low risks for causing coagulation and platelet and hematologic adverse reactions,which are suggested to be evaluated for hemolysis testing only in case of the history of safe clinical use.[Chinese Medical Equipment Journal,2025,46(8):44-49]
9.Necessity of blood hemocompatibility evaluation in medical devices with indirect contact with blood
Chun-xia QIAO ; Qiu-jin QU ; Li HOU ; Zeng-lin ZHAO ; Xiang-yu CHU ; Xiao-xia SUN
Chinese Medical Equipment Journal 2025;46(8):44-49
Objective To study the need for blood compatibility evaluation of medical devices that come into indirect contact with blood in order to accurately evaluate the risk of their interaction with blood.Methods Seven medical devices with indirect contact with blood were selected as samples including extension tubes of central venous catheters,port bodies of implantable drug delivery devices,infusion sets,receiving lines of dialysis equipment,auxiliary lines of left ventricular assist devices,blood monitors and catheter holders,with high-density polyethylene as the negative control,glass beads as the positive control and blank whole blood or plasma for the blank control.Partial thromboplastin time(PTT)test,platelet count test and hematology test(white blood cell and red blood cell count)were performed by direct contact method and indirect contact method,respectively.In the direct contact method,whole blood or plasma was in direct contact with the sample;while in the indirect contact method,whole blood or plasma was not in direct contact with the extraction solution,with no direct contact with the sample.Results With the indirect contact method the ratios(expressed as a percentage)of the PTT,platelate,WBC and RBC counts of the samples,positive and negative controls to those of the blank control were all higher than those with the direct contact method,and the indirect contact method had the sensitivity lower than that of the direct contact method.Conclusion Medical devices indirectly contacting blood have low risks for causing coagulation and platelet and hematologic adverse reactions,which are suggested to be evaluated for hemolysis testing only in case of the history of safe clinical use.[Chinese Medical Equipment Journal,2025,46(8):44-49]
10.An animal experimental study on endoscopic ultrasound-guided non-invasive measurement of portal venous pressure in liver cirrhosis
Wei-xiang QU ; Wen-ying SHEN ; Guang-chao YANG ; Jin-feng QI ; Yu-ying ZHENG
Journal of Regional Anatomy and Operative Surgery 2025;34(1):11-15
Objective To compare the differences of endoscopic ultrasound (EUS)-guided non-invasive measurement of portal venous pressure and EUS-guided portal pressure gradient(EUS-PPG) in measurement of portal venous pressure on animals and their correlation. Methods Twenty-four miniature pigs were selected and fed with carbon tetrachloride and phenobarbital sodium combined with high-fat,low-protein and low-choline diet for 16 weeks to establish a liver cirrhotic portal hypertension model. The changes of biochemical indexes of liver function and liver pathology in the experimental pigs were observed to evaluate whether the model was successful. After the model was successfully established,the hemodynamic parameters of the portal venous trunk were measured non-invasively under EUS guidance,including portal venous blood flow and splenic artery pulsatility index,thereby calculating portal venous pressure. Then,taking EUS-PPG,the portal vein,hepatic vein,and inferior vena cava were punctured with an 18G puncture needle under general anesthesia guided by the translinear endoscopic ultrasound,and the PPG was calculated through the central venous pressure monitoring system.The Pearson correlation analysis,Kappa test,ICC intraclass correlation coefficient and Bland-Altman plot were used for consistency analysis. Results All the 24 pigs survived 16 weeks after modeling.The serum levels of alanine transaminase (ALT),aspartate transaminase (AST),albumin (ALB),globulin (GLB),total bilirubin (TBIL) and indirect bilirubin (IBIL)after modeling were higher than those before modeling(P<0.05). HE staining and Sirius red staining showed abnormal liver morphology and increased collagen fibers after modeling,suggesting that the experimental pig model of liver cirrhotic portal hypertension was successfully established. The results of EUS-guided non-invasive measurement of portal venous pressure showed that the mean splenic artery pulsatility index was (2.03±0.68),the mean portal vein flow was (17.27±4.31)cm/s,and the mean portal venous pressure was (15.97±3.65)mmHg. The measurement results of the mean portal venous pressure,hepatic venous pres-sure and PPG of EUS-PPG were (20.68±4.71)mmHg,(4.07±2.14)mmHg and (16.38±4.28)mmHg respectively. Pearson correlation analysis showed that there was a significant positive correlation between the portal venous pressures measured by the two methods (r=0.902,P<0.001);the consistency tests of Kappa test and ICC intraclass correlation coefficient showed that the measurement results of the two methods were highly consistent (Kappa=0.699,P<0.001;ICC=0.945);Bland-Altman plot analysis showed that most of the points fell within 95% limits of agreement. Conclusion EUS-guided non-invasive measurement of portal venous pressure has a high correlation and consistency with the measurement results by EUS-PPG,which has high success rate,and accurate reflection of portal venous pressure,with low cost and good safety.


Result Analysis
Print
Save
E-mail