1.Comparison of Natriuretic Peptide Levels in Sinus Rhythm and Atrial Fibrillation in Acute Heart Failure
Minjae YOON ; Jin Joo PARK ; Jong-Chan YOUN ; Sang Eun LEE ; Hae-Young LEE ; Jin Oh CHOI ; Kye Hun KIM ; Dong Heon YANG ; Myeong-Chan CHO ; Seok-Min KANG ; Byung-Su YOO
International Journal of Heart Failure 2025;7(2):85-95
Background and Objectives:
In chronic heart failure (HF), natriuretic peptide (NP) levels are higher in atrial fibrillation (AF) compared to sinus rhythm (SR). However, due to the loss of atrial contraction, AF patients are prone to hemodynamic decompensation at earlier stages.Since NP levels reflect disease severity, acutely decompensated AF patients may exhibit lower NP levels compared to SR patients, who retain greater hemodynamic reserve.
Methods:
We analyzed 5,048 patients with acute HF from the Korea Acute Heart Failure registry with available NP data. NP levels and echocardiographic parameters were compared between AF and SR patients. The association of NP levels with in-hospital and one-year mortality was also assessed according to cardiac rhythm.
Results:
Brain natriuretic peptide (BNP) and N-terminal pro-B-type natriuretic peptide (NT-proBNP) were measured in 2,027 and 3,021 patients, respectively. NP levels were lower in AF than in SR (median BNP, 740 vs. 1,044 pg/mL; median NT-proBNP, 4,420 vs. 5,198 pg/mL), particularly in HF with reduced or mildly reduced ejection fraction. A similar trend was observed regardless of HF onset or etiology. AF patients had smaller left ventricular (LV) end-diastolic diameter and larger left atrial size compared to SR patients. Higher NP tertiles were associated with increased in-hospital and one-year mortality in both groups.
Conclusions
In acute HF, NP levels are lower in AF than in SR. AF patients also exhibited smaller LV chamber sizes. Nevertheless, NP levels remain strong predictors of outcomes in both AF and SR patients.
3.Palliative Care and Hospice for Heart Failure Patients: Position Statement From the Korean Society of Heart Failure
Seung-Mok LEE ; Hae-Young LEE ; Shin Hye YOO ; Hyun-Jai CHO ; Jong-Chan YOUN ; Seong-Mi PARK ; Jin-Ok JEONG ; Min-Seok KIM ; Chi Young SHIM ; Jin Joo PARK ; Kye Hun KIM ; Eung Ju KIM ; Jeong Hoon YANG ; Jae Yeong CHO ; Sang-Ho JO ; Kyung-Kuk HWANG ; Ju-Hee LEE ; In-Cheol KIM ; Gi Beom KIM ; Jung Hyun CHOI ; Sung-Hee SHIN ; Wook-Jin CHUNG ; Seok-Min KANG ; Myeong Chan CHO ; Dae-Gyun PARK ; Byung-Su YOO
International Journal of Heart Failure 2025;7(1):32-46
Heart failure (HF) is a major cause of mortality and morbidity in South Korea, imposing substantial physical, emotional, and financial burdens on patients and society. Despite the high burden of symptom and complex care needs of HF patients, palliative care and hospice services remain underutilized in South Korea due to cultural, institutional, and knowledge-related barriers. This position statement from the Korean Society of Heart Failure emphasizes the need for integrating palliative and hospice care into HF management to improve quality of life and support holistic care for patients and their families. By clarifying the role of palliative care in HF and proposing practical referral criteria, this position statement aims to bridge the gap between HF and palliative care services in South Korea, ultimately improving patient-centered outcomes and aligning treatment with the goals and values of HF patients.
4.Delayed Diagnosis of Brachial Plexus Injury Due to Vertebral Arteriovenous Fistula Caused by Blunt Trauma
Jin Gee PARK ; Jae Yeon KIM ; Young Sook PARK ; Hyun Jung CHANG ; Eun Sol CHO ; Da Hye KIM ; Jeong Hwan LEE ; Se Jin KIM
Journal of Electrodiagnosis and Neuromuscular Diseases 2025;27(1):18-22
Vertebral arteriovenous fistula (VAVF) is a rare lesion characterized by an abnormal connection between the extracranial vertebral artery and the surrounding venous plexus. It typically arises due to penetrating injury, although it can occasionally result from blunt trauma. Brachial plexus injury (BPI) is also infrequently associated with VAVF. We present a rare case of VAVF caused by blunt trauma, which resulted in BPI. The patient, who had previously sustained a C2 fracture and C2–3 myelopathy from a bicycle accident, presented with new-onset weakness in the right upper extremity. His previous clinical history led to an initial suspicion of either an exacerbation of a pre-existing lesion or a shoulder injury. However, electromyography indicated that the weakness was due to BPI. Further evaluations later revealed VAVF to be the primary cause of the BPI. VAVF must be recognized as a rare potential reason for BPI, as timely intervention is essential for improving patient recovery and prognosis.
5.Development of Hydrogel Sun Patch with Wound Healing Efficacy
Da-Ye NAM ; Jin WOO ; Youngtae KIM ; JungHoon CHAE ; Young-Shin LEE ; Ji-Youl JUNG
Journal of Wound Management and Research 2025;21(1):10-17
Background:
This study focuses on the development of a hydrogel wound patch incorporating natural extracts, designed to function as a sun patch. By maintaining a moist environment and delivering bioactive compounds, the patch promotes wound healing while also providing cooling and ultraviolet (UV) protection. This dual-purpose approach enhances skin recovery and shields damaged areas from external stressors. The study aims to optimize the formulation and evaluate its efficacy for both therapeutic and cosmetic applications.
Methods:
Hydrogel solutions prepared using acrylamide, glycerol, and carboxymethyl cellulose were enriched with extracts from Saururus chinensis, Styrax japonicus, and Centella asiatica. The enriched solutions were processed into patches and tested for their adhesion, cooling effects, and UV protective abilities. Additionally, the wound healing efficacy was evaluated in a mouse model.
Results:
The hydrogel patches demonstrated comparable adhesion properties, effective skin cooling, and high UV protection rates similar to those of commercially available products. In the mouse model, the patches significantly improved wound closure and tissue regeneration in the experimental group as compared to the control group.
Conclusion
The study confirms that hydrogel sun patches enriched with natural extracts have the ability to effectively promote wound healing and offer substantial UV protection and cooling benefits, demonstrating their potential medical and cosmetic applications.
6.Comparison between Suture-Button Technique with Syndesmotic Repair and Screw Fixation Technique for Complete Ankle Syndesmotic Injury: Biomechanical Cadaveric Study
Hong Seop LEE ; Sung Hwan KIM ; Ki Won YOUNG ; Woo Jong KIM ; Dong-Il CHEON ; Sung Hun WON ; Sang Heon LEE ; Seung Jin CHOI ; Young Koo LEE
Clinics in Orthopedic Surgery 2025;17(2):324-330
Background:
The tibiofibular syndesmosis is essential for preserving the stability of the ankle. Acute syndesmotic injuries with evident or latent instability usually warrant surgical interventions. This cadaveric study examines and compares biomechanical characteristics between the following treatments for syndesmosis injuries: suture-button fixation plus syndesmotic repair and screw fixation.
Methods:
The lower extremities of 10 cadavers disarticulated at the knee joints were used, yielding 20 feet. Ten feet underwent surgery using the suture-button fixation with syndesmotic repair, while the remaining 10 feet underwent surgery using screw fixation. Before surgical treatment of syndesmosis injuries, each cadaveric lower limb underwent preliminary physiological cyclic loading, which was followed by a series of postfixation cyclic loading tests after the surgical procedure.
Results:
Our principal finding is that suture-button fixation with syndesmotic repair provided torsional strength comparable to that of screw fixation. The mean failure torque did not differ between the 2 groups, but the rotational stiffness was significantly lower in the suture-button fixation/augmentation group.
Conclusions
Suture-button fixation/augmentation facilitates flexible (physiological) syndesmosis movement and may be a useful alternative treatment for ankle syndesmosis injury.
7.Hyperlipidemia and Rotator Cuff Tears: Exploring Mechanisms and Effective Treatment
Kang-San LEE ; Sung-Jin PARK ; Dong-Hyun KIM ; Seok Won CHUNG ; Jun-Young KIM ; Chul-Hyun CHO ; Jong Pil YOON
Clinics in Orthopedic Surgery 2025;17(2):187-193
The detrimental effects of hyperlipidemia on the healing of rotator cuff tears are well documented. The proposed underlying mechanisms for these effects include alterations in the extracellular matrix, inflammation, and oxidative stress, which hamper the reparative processes in the affected tendon tissues. Recent therapeutic strategies target these pathways, reflecting a growing body of research dedicated to mitigating these effects and promoting healing. This literature review aims to provide a comprehensive understanding of the pathophysiology underlying rotator cuff tears, examine the interplay between hyperlipidemia and rotator cuff tear healing, synthesize current knowledge on contributing biological mechanisms, and outline potential therapeutic interventions to optimize clinical management and treatment outcomes for patients.
8.Comparing Outcomes between Cage Alone and Plate Fixation in Single-Level Anterior Cervical Fusion: A Retrospective Clinical Series
Jae-Won SHIN ; Han-Bin JIN ; Yung PARK ; Joong-Won HA ; Hak-Sun KIM ; Kyung-Soo SUK ; Sung-Hwan MOON ; Si-Young PARK ; Byung-Ho LEE ; Ji-Won KWON ; In-Uk KIM
Clinics in Orthopedic Surgery 2025;17(3):417-426
Background:
To identify the optimal surgical technique for single-level anterior cervical discectomy and fusion (ACDF), this study compared surgical outcomes and incidence of adjacent segment degeneration (ASD) in patients undergoing single-level ACDF using cage alone single-level fusion and plate fixation techniques.
Methods:
This single-center retrospective study (2003–2018) included patients who underwent single-level ACDF with either plate fixation (PLATE) or cage (CAGE) alone. The radiologic and clinical outcomes between the 2 surgical groups were compared over a 4-year follow-up period. Outcomes of interest included parameters related to range of motion, sagittal alignment, as well as fusion, subsidence, and ASD rates. Clinical outcomes were evaluated using the Neck Disability Index (NDI) and visual analog scale (VAS) for pain. Dysphagia and hoarseness rates were estimated based on medical records.
Results:
Forty-seven patients were included (n=17 in CAGE group). In the CAGE group, 94.1% of the patients had Bridwell grade 1 or 2, compared to 83.3% in the PLATE group (p = 0.396). Subsidence occurred in 12.5% and 3.6% of the CAGE and PLATE cases, respectively (p = 0.543). Segmental kyphosis progressed in the CAGE group compared to the PLATE group at 12, 24, and 48 months (p < 0.001). Radiographic ASD was observed in 41.2% and 30.0% of patients in the CAGE and PLATE groups, respectively, with a higher incidence in the upper segments for both groups. Preoperative NDI scores were similar between the groups; however, postoperatively, the CAGE group had significantly lower NDI scores (3.50 ± 2.74 vs. 8.00 ± 5.81) at 4 years (p = 0.020). Neck pain VAS scores also showed significant improvement in the CAGE group (2.33 ± 2.94) compared with that in the PLATE group (3.07 ± 2.31) at 4 years (p = 0.045). Both groups showed comparable arm pain VAS scores at 2 and 4 years postoperatively. Postoperative dysphagia occurred in 1 patient in the PLATE group, resolving almost completely by 1 year.
Conclusions
Single-level ACDF using a cage alone technique demonstrated favorable radiologic and clinical outcomes overall compared to plate-augmented ACDF. However, plate augmentation is recommended for patients with severe cervical kyphosis or those at high risk of subsidence.
9.Powered Tool for the Removal of a Well-Fixed Acetabular Cup: A Comparative Experimental Study
Jun Young CHUNG ; Yonghan CHA ; Chang-Ho JUNG ; Jin-Woo KIM ; Jun-Il YOO ; Jung-Taek KIM ; Yongho JEON
Clinics in Orthopedic Surgery 2025;17(3):372-380
Background:
The removal of a well-fixed acetabular cup is a challenging, labor-intensive, and time-consuming step during revision hip arthroplasty. Although the advent of the manual osteotome, Explant, has simplified the procedure, it is still a stressful process as it dissipates the surgeon’s strength and time and risks an iatrogenic pelvic fracture. Recently, EZX, a powered tool for extraction of well-fixed acetabular cups with semicircular blade was invented. This study aimed to compare Explant and EZX in an experimental condition for their efficacy and safety.
Methods:
Cementless acetabular cups were press-fitted to 20 hemipelvic polyurethane models using foam adhesives. Ten cups were removed with each tool for comparison of the elapsed time, loads on the entire hemipelvis, periacetabular strain and temperature, volume of periacetabular bone removed, and diameter of the remaining acetabular rim. Strains and loads were quantitatively assessed using strain gauges and load cells for precise and reliable measurements.
Results:
The mean duration required to remove a well-fixed cup with EZX was 38.5 seconds (range, 25–55), whereas that with Explant was 543.7 seconds (range, 214–1,051) (p < 0.001). The load on the entire hemipelvis with EZX (mean, 9.1 kgf; range, 6.4–11.3) was 33% lower than that with Explant (mean, 13.6 kgf; range, 9.2–17.1) (p < 0.001). The periacetabular peak strains at the 3 positions with EZX were significantly lower than those with Explant (p < 0.001). The temperature during the removal did not differ significantly between the 2 tools. Although the mean volume of bone loss with Explant was 2.4 mL more than that with EZX (p < 0.001), the mean diameters of the remaining acetabular rim were not significantly different, measuring 54.1 mm with both tools.
Conclusions
The present experiment revealed that a well-fixed cup could be removed using a powered tool with less strength and time and less load on the entire pelvis. Although the powered tool removed a larger volume of bone, the diameters of the remaining acetabular rims were equivalent. This tool may help surgeons remove well-fixed cups in a short time and reduce the deforming load on the bone around the cup without increasing the size of the subsequent reconstruction cup.
10.Reproducibility of Plasma Biomarker Measurements Across Laboratories:Insights Into ptau217, GFAP, and NfL
Heekyoung KANG ; Sook-Young WOO ; Daeun SHIN ; Sohyun YIM ; Eun Hye LEE ; Hyunchul RYU ; Bora CHU ; Henrik ZETTERBERG ; Kaj BLENNOW ; Jihwan YUN ; Duk L NA ; Hee Jin KIM ; Hyemin JANG ; Jun Pyo KIM ;
Dementia and Neurocognitive Disorders 2025;24(2):91-101
Background:
and Purpose: Plasma biomarkers, including phosphorylated tau (ptau217), glial fibrillary acidic protein (GFAP), and neurofilament light chain (NfL), are promising tools for detecting Alzheimer’s disease (AD) pathology. However, cross-laboratory reproducibility remains a challenge, even when using identical analytical platforms such as single-molecule array (Simoa). This study aimed to compare plasma biomarker measurements (ptau217, GFAP, and NfL) between 2 laboratories, the University of Gothenburg (UGOT) and DNAlink, and evaluate their associations with amyloid positron emission tomography (PET) imaging.
Methods:
Plasma biomarkers were measured using Simoa platforms at both laboratories:the UGOT and DNAlink Incorporation. Diagnostic performance for predicting amyloid PET positivity, cross-laboratory agreement, and the impact of normalization techniques were assessed. Bland-Altman plots and correlation analyses were employed to evaluate agreement and variability.
Results:
Plasma ptau217 concentrations exhibited strong correlations with amyloid PET global centiloid values, with comparable diagnostic performance between laboratories (area under the curve=0.94 for UGOT and 0.95 for DNAlink). Cross-laboratory agreement for ptau217 was excellent (r=0.96), improving further after natural log transformation. GFAP and NfL also demonstrated moderate to strong correlations (r=0.86 for GFAP and r=0.99 for NfL), with normalization reducing variability.
Conclusions
Plasma biomarker measurements were consistent across laboratories using identical Simoa platforms, with strong diagnostic performance and improved agreement after normalization. These findings support the scalability of plasma biomarkers for multicenter studies and underscore their potential for standardized applications in AD research and clinical practice.

Result Analysis
Print
Save
E-mail