1.Compact Fundus Imaging System Using Shack-Hartmann Wavefront Sensing for High-speed Auto-focus
Zhe-Kai LIN ; Long CHEN ; Geng-Yong ZHENG ; Jin-Tian HUANG ; Jia-Xin DONG ; Shang-Pan YANG ; Wen-Zheng DING ; Ding-An HAN ; Xue-Hua WANG ; Ya-Guang ZENG
Progress in Biochemistry and Biophysics 2026;53(4):1076-1086
ObjectiveThe widespread adoption of portable fundus cameras for primary care and community screening is hindered by limitations in current autofocus(AF) technologies. Image-based methods relying on sharpness evaluation require iterative searches, resulting in slow convergence, while projection-based techniques are susceptible to optical artifacts and calibration errors. To address these challenges, this study introduces a novel AF system based on direct wavefront sensing, designed to deliver simultaneous high speed, high precision, and operational robustness within the compact form factor essential for portable ophthalmic devices. MethodsOur approach fundamentally reimagines the AF process by directly measuring the ocular wavefront aberration. We developed a custom portable fundus camera integrating a miniaturized Shack-Hartmann wavefront sensor (SHWS) into the optical path. An 850 nm laser diode projects a point source onto the retina via oblique illumination to minimize corneal reflections. Light scattered from this spot carries the eye’s refractive error through the imaging optics and is directed to the SHWS, positioned at a plane optically conjugate to the primary color CMOS imaging sensor. A microlens array within the SHWS samples the incident wavefront, generating a pattern of focal spots on a CCD. Real-time centroid analysis of these spots provides a map of local wavefront slopes. These measurements are processed through a singular value decomposition (SVD) algorithm to fit a Zernike polynomial basis set, enabling real-time reconstruction of the wavefront phase. The defocus component (S) is extracted from the second-order Zernike coefficients, providing a direct, quantitative measure of the refractive error in diopters. This value serves as a precise error signal in a closed-loop control system, which commands a voice-coil actuated focusing lens to its null position in a single, deterministic step, eliminating the need for iterative search algorithms. ResultsComprehensive evaluation demonstrated the system’s high performance. Testing on a calibrated model eye (OEMI-7) established a highly linear relationship between the computed defocus S and the focusing lens position across a ±20 Diopter (D) compensation range, achievable within a 5 mm mechanical travel. The system achieved a focusing precision of 0.08 D, corresponding to an 18-fold improvement over a conventional projection spot-size method tested under identical conditions. The total focus acquisition time, encompassing wavefront measurement, computation, and lens actuation, averaged under 0.5 s. Clinical validation with 25 human volunteers (50 eyes, refractive range -15 D to +10 D) confirmed practical efficacy. The wavefront-sensing AF succeeded in 92% of attempts with a mean time of 0.5 s, substantially outperforming a projection-based benchmark which achieved only a 32% success rate with an average time of 4.25 s. The system provided instantaneous directional guidance and maintained stability during minor ocular movements. Objective assessment of image quality, via amplitude contrast of retinal vasculature, showed consistent and significant enhancement following AF correction across the entire tested diopter range. ConclusionThis work successfully implements and validates a direct wavefront-sensing autofocus paradigm for portable fundus cameras. By directly quantifying and compensating for the optical defocus aberration, this method bypasses the fundamental limitations of image-processing and projection-based techniques, enabling rapid, precise, and deterministic diopter compensation. The developed system delivers an exceptional combination of a wide operational range (±20 D), high accuracy (0.08 D), fast convergence (0.5 s), and a compact physical footprint. This technology provides a practical and high-performance focusing solution capable of enhancing the reliability, throughput, and diagnostic utility of portable retinal imaging in large-scale screening applications. Future efforts will be directed towards system cost optimization and performance adaptation for diverse ocular conditions.
2.Interventional revascularization combined with perforator composite flap for staged treatment of peripheral arterial disease with ankle soft tissue defects.
Xiaoguang GUO ; Zhiguo WANG ; Zheng KANG ; Yanzhou LI ; Junxian YANG ; Weihua FENG ; Honglüe TAN ; Guoqiang JIN ; Xinwei WANG
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(12):1580-1585
OBJECTIVE:
To explore the effectiveness of primary interventional revascularization combined with secondary perforator composite flap in the treatment of peripheral arterial disease (PAD) accompanied by soft tissue defects around the ankle.
METHODS:
Between January 2022 and January 2025, 12 patients with PAD and soft tissue defects around the ankle were admitted. Among them, there were 9 males and 3 females; their ages ranged from 52 to 82 years, with an average of 68.9 years. The causes of injury included 4 cases of traffic accident, 5 cases of falls, 1 case of falling from height, 1 case of foreign body puncture injury, and 1 case of electric shock injury. The infection duration ranged from 1 month to 35 years, with a median duration of 3.5 months. The wound size ranged from 5.5 cm×3.0 cm to 15.0 cm×9.0 cm. The ankle-brachial index (ABI) was 0.32±0.12. The visual analogue scale (VAS) score for pain was 3.3±0.5. Preoperative vascular stenosis assessment was performed in all patients, with primary intervention to dredge large and medium-sized arteries, followed by secondary repair of the wound using a perforator composite flap. The flap size ranged from 6.5 cm×4.0 cm to 16.0 cm×10.0 cm. The donor sites were sutured directly or repaired with skin grafts. After two stages of treatment, the effectiveness was evaluated by measuring ABI, observing flap survival and wound healing, assessing VAS scores, and American Orthopedic Foot and Ankle Society (AOFAS) scores.
RESULTS:
All 12 cases completed two stages of treatment; all patients were followed up after the second-stage treatment, with a follow-up period ranging from 7 to 28 months, with an average of 16.8 months. After the first-stage treatment, the skin temperature around the ankle was significantly higher than that before treatment, and the ABI increased to 0.71±0.07, with a significant difference ( t=9.918, P<0.001). After the second-stage treatment, the blisters on the distal end of the skin flap occurred in 3 cases. The flaps survived and the wounds healed, with a healing time ranging from 10 to 14 days (mean, 11.8 days). The incisions at the donor site healed by first intention, and the skin grafts survived. The VAS score was 0.5±0.5 at 3 weeks, which was significantly lower than that before treatment ( t=13.675, P<0.001). No infection recurrence occurred during follow-up. At 6 months after the second-stage treatment, the AOFAS score of the ankle joint ranged from 92 to 97, with an average of 94.7, all reaching excellent.
CONCLUSION
Interventional revascularization combined with perforator composite flap for staged treatment of PAD with ankle soft tissue defects can obtain good effectiveness, by unclogging the main blood vessels, improving lower limb blood supply, and improving the survival rate of the skin flap.
Humans
;
Male
;
Female
;
Middle Aged
;
Aged
;
Peripheral Arterial Disease/surgery*
;
Soft Tissue Injuries/surgery*
;
Perforator Flap/blood supply*
;
Plastic Surgery Procedures/methods*
;
Aged, 80 and over
;
Ankle/blood supply*
;
Treatment Outcome
;
Ankle Brachial Index
;
Skin Transplantation/methods*
3.Application of grid locator in hip arthroscopy for the treatment of femoroacetabular impingement features.
Kun-Yang XIA ; Wen-Li RUAN ; Shou-Yun WANG ; Jin-Xian YANG
China Journal of Orthopaedics and Traumatology 2025;38(2):176-182
OBJECTIVE:
To explore the application effect of grid locator in hip arthroscopy for the treatment of femoral acetabular impingement (FAI).
METHODS:
Total of 50 patients of FAI were treated by arthroscopic hip joint surgery for from January 2020 to January 2021, and were divided into two groups according to intraoperative positioning methods. Among them, 27 cases in the positioner group were treated by hip arthroscopy assisted by grid positioner including 10 males and 17 females with a mean age of (35.91±9.92) years old. In the non-locator group, 23 cases were treated with hip arthroscopy by positioning puncture according to the operator's experience including 12 males and 11 females with a mean age of (36.01±11.03) years old. Intraoperative fluoroscopy times, puncture time, adjusted puncture times and operation time of two groups were compared. The α Angle and lateral central edge(LCE) angle of hip joint were measured and compared before and after operation. Four evaluation indexes were recorded and compared, including pain visual analogue scale(VAS), hip Harris score, non-inflammatory hip joint score (NAHS), hip joint activities of daily living (HOS-ADL).
RESULTS:
All patients were followed up for 6 to 12 months with an average of (18.69±3.72) months. The α angle and LCE angle of hip joint at 1 month after operation were decreased in both groups(P<0.05), but there was no significant difference between groups(P>0.05). VAS, hip Harris score, NAHS and HOS-ADL score after operation were higher than those before operation(P<0.05), but there was no statistical significance between groups (P>0.05). Intraoperative fluoroscopy times(6.04±1.13), puncture time(13.19±3.52) min, puncture adjustment times(4.59±1.55) and operation time(48.28±3.38) min in the positioner group were less (shorter) than those of (13.43±2.56), (22.39±2.93) min, (10.43±3.33), (62.25±5.73) min in the non-positioner group(P<0.05). No postoperative complications occurred in both groups, and the pain was significantly relieved.
CONCLUSION
The application of hip arthroscopy in the treatment of femoral acetabular impingement sign can obtain good postoperative results. Compared with the traditional positioning method, the grid locator can improve the accuracy of skin positioning point, shorten the puncture time, reduce the number of fluoroscopy, and improve the efficiency of surgical puncture.
Humans
;
Male
;
Female
;
Arthroscopy/instrumentation*
;
Femoracetabular Impingement/physiopathology*
;
Adult
;
Middle Aged
;
Hip Joint/surgery*
4.Clinical features and surgical treatment strategies of hip arthroplasty for unhealed old femoral intertrochanteric fractures.
Qing XIA ; Chuan-Wen LIU ; Yu-Cheng XIA ; Hui-Yang WANG ; Jin-Quan GUO
China Journal of Orthopaedics and Traumatology 2025;38(2):188-194
OBJECTIVE:
To explore the surgical method and clinical efficacy of hip arthroplasty in the treatment of old non-union femoral intertrochanteric fractures.
METHODS:
Fifteen unoperated patients suffering from old non-union femoral intertrochanteric fractures from Feburary 2013 to Feburary 2023 were treated with hip arthroplasty including 9 males and 6 females, aged 71 to 82 years old. Eleven cases detected deep venous thrombosis(DVT), 9 cases received lower vena cava filter implantation. The operation time, intraoperative blood loss, intraoperative and postoperative blood transfusion, postoperative hemoglobin content, procedure-related complications, and the range of motion of hip flexion, abduction motion were recorded. The degree of hip pain was evaluated using a visual analogue scale(VAS). The hip Harris scores were used to evaluated the clinical efficacy.
RESULTS:
All patients were followed up for 3 to 12 months. The intraoperative blood loss was 200 to 400 ml, intraoperative blood transfusion was 0 to 400 ml, and the operation time was 40 to 90 min. All 15 patients had different degrees of anemia after surgery, the 3 days postoperative hemoglobin was 72 to 97 g·L-1, and the postoperative transfusion volume was 0 to 400 ml. All patients had no periprosthetic infection, poor incision healing, lower limb deep vein thrombosis, and cerebral infarction. One case occurred in the early postoperative period, which disappeared from 4 to 5 days after operation, and there was no further revision at the last follow-up. The VAS was 6 to 7 points before operation and 2 to 4 points at latest follow-up;the hip Harris score was 2 to 13 points before operation and 73 to 84 points at latest follow-up.
CONCLUSION
The unoperated patients of old non-union femoral intertrochanteric fractures had significant clinical and imaging characteristics. Hip arthroplasty combined with or without femoral calcar reconstruction in the treatment of old non-union femoral intertrochanteric fractures had the advantages of relatively simple manipulation, rigid fixation, relatively safe operation, and relatively exact efficacy.
Humans
;
Male
;
Female
;
Aged
;
Hip Fractures/physiopathology*
;
Aged, 80 and over
;
Arthroplasty, Replacement, Hip/methods*
5.Early curative effect of upper capsular reconstruction combined with biceps tendon transposition for the treatment of unrepairable rotator cuff tear by arthroscopy.
Xi-Hao WANG ; Zhi-Tao YANG ; Jun-Wen LIANG ; Bai-Rong ZHANG ; Tao LIU ; Jin JIANG ; Xiang-Dong YUN
China Journal of Orthopaedics and Traumatology 2025;38(3):238-244
OBJECTIVE:
To explore early curative effect of upper joint capsule reconstruction combined with biceps tendon transposition in treating irreparable rotator cuff tears.
METHODS:
From October 2019 to March 2021, 16 patients with irreparable rotator cuff tear were underwent arthroscopic autogenous semitendinosus tendon transplantation for upper articular capsule reconstruction combined with biceps tendon transposition, included 12 males and 4 females, aged from 53 to 72 years old with an average of (62.13±5.35) years old; 3 patients on the left side and 13 patients on the right side. All patients had preoperatively limited joint mobility, resting pain, and mobility pain, and had a history of failure to respond to conservative treatment for more than 8 months. The duration of preoperative symptoms ranged from 45 to 144 months with an average of (85.25±32.08) months. Visual analogue scale (VAS) of shoulder pain, University of California Los Angeles (UCLA) score, Constant-Murley score, active and passive motion of shoulder joint were compared before operation and 2 years after operation, complications were recorded.
RESULTS:
All 16 patients were followed up for 21 to 32 months with an average of (24.25±3.57) months. There were no complications such as incision infection, vascular and nerve injury, retear occurred. VAS, UCLA and Constant-Murley scores were improved from (5.75±1.18), (11.88±3.38) and (33.38±9.34) before operation to (1.13±0.89), (32.56±2.71), (89.06±6.25) at 2 years after operation (P<0.05). Anterior flexion, abduction, lateral external rotation and lateral internal rotation of shoulder joint were improved from (79.75±21.36) °, (62.06±10.49) °, (19.19±5.41) °, (3.04±0.21) °, respectively to (156.94±13.18) °, (116.19±12.59) °, (42.63±6.07) °, (8.16±0.64) ° at 2 years after operation. Anterior flexion, abduction, lateral lateral rotation and lateral internal rotation of shoulder joint were improved from (116.28±21.47) °, (107.12±9.67) °, (27.62±4.70) °, (4.21±0.41) °, respectively to (165.28±7.15) °, (153.34±4.69) °, (52.46±4.46) °, (9.68±0.68) ° at 2 years after operation, and the difference was statistically significant (P<0.05).
CONCLUSION
Arthroscopic autograft of semitendinosus tendon combined with transposition of biceps tendon could achieve satisfactory early clinical results in treating patients with irreparable rotator cuff tear, which is a reliable and effective surgical method.
Humans
;
Male
;
Female
;
Middle Aged
;
Aged
;
Arthroscopy/methods*
;
Rotator Cuff Injuries/physiopathology*
;
Plastic Surgery Procedures/methods*
;
Range of Motion, Articular
;
Shoulder Joint/surgery*
;
Tendon Transfer
6.Experimental study on autologous osteochondral transplantation in the treatment of recurrent anterior dislocation of the shoulder joint with articular cartilage defect in rabbits.
Tao LIU ; Sen FANG ; Fang-Xiang LIU ; Ming-Tao ZHANG ; Zhi-Tao YANG ; Bo-Rong ZHANG ; Jun-Wen LIANG ; Xi-Hao WANG ; Jin JIANG ; Xiang-Dong YUN
China Journal of Orthopaedics and Traumatology 2025;38(6):619-625
OBJECTIVE:
To explore clinical effect of autologous osteochondral transplantation (AOT) in the treatment of recurrent anterior dislocation of the shoulder joint with glenoid cartilage defect in rabbits by establishing a model of recurrent anterior dislocation of the shoulder joint with < 20% glenoid cartilage defect in rabbits.
METHODS:
Twenty-four male New Zealand white rabbits, aged 6-month-old, weighed (2.69±0.17) kg were selected. The labrum of shoulder joint of rabbits was artificially destroyed to establish a model of recurrent anterior dislocation of shoulder joint with cartilage defect. They were divided into AOT surgery group and simple suture group, with 12 rabbits in each group. AOT group were underwent AOT surgery, while simple suture group was treated with simple Bankart suture for recurrent shoulder joint dislocation. At 6 and 12 weeks after operation, 6 rabbits between two groups were sacrificed for sampling. The dietary conditions, activity conditions, mental states of rabbits and healing conditions of grafts in the specimens were observed and compared between two groups. HE staining was used to observe cell creep, cell morphology, inflammatory cell infiltration, fibrochondrocytes and their arrangement. Masson staining was used to observe the formation and arrangement of collagen fibers; Safrane-green staining was used to observe the regeneration of articular cartilage, subchondral bone and bone tissue. Bone mineral density (BMD), bone volume (BV) and trabecular thickness (Tb.Th) between two groups were measured by Micro-CT to evaluate the remodeling of shoulder glenoid bone defects by autologous osteochondral cartilage.
RESULTS:
After different surgical interventions were carried out in both groups of rabbits, at 6 weeks after the operation, the abduction, extension, internal rotation and external rotation of the shoulder joint on the operated side showed limited range of motion compared with the contralateral side, while adduction and forward flexion showed no obvious abnormalities compared with the contralateral side. At 12 weeks after operation, the range motion of tshoulder joints in both groups of rabbits had returned to the state before modeling. The effects of HE staining, Masson staining and safrane-green staining at 12 weeks after operation in both groups were stronger than the staining results at 6 weeks after operation. Moreover, the results of HE staining, Masson staining and safranin fixation green staining in AOT group at 6 and 12 weeks after operation were all higher than those in simple suture group. Micro-CT scan results at 6 and 12 weeks after operation showed that BMD (0.427±0.014), (0.466±0.032) g·cm-3, BV(116.171±3.527), (159.327±3.500) mm3, and Tb.Th (0.230±0.006), (0.285±0.009) mm in AOT group, which were higher than those of simple suture group in BMD(0.358±0.011), (0.384±0.096) g·cm-3, BV(72.657±3.903), (118.713±3.860) mm3, and Tb.Th(0.204±0.009), (0.243±0.007) mm;and the differences were statistically significant (P<0.05).
CONCLUSION
AOT procedure could effectively promote osteogenesis and fibrocartilage regeneration in the cartilage defect area of the shoulder glenoid <20%, which is conducive to reshaping the structure of the shoulder glenoid.
Animals
;
Rabbits
;
Male
;
Transplantation, Autologous
;
Cartilage, Articular/injuries*
;
Shoulder Dislocation/physiopathology*
;
Bone Transplantation
;
Shoulder Joint/surgery*
7.Application of 3D-printed auxiliary guides in adolescent scoliosis surgery.
Dong HOU ; Jian-Tao WEN ; Chen ZHANG ; Jin HUANG ; Chang-Quan DAI ; Kai LI ; Han LENG ; Jing ZHANG ; Shao-Bo YANG ; Xiao-Juan CUI ; Juan WANG ; Xiao-Yun YUAN
China Journal of Orthopaedics and Traumatology 2025;38(11):1119-1125
OBJECTIVE:
To investigate the accuracy and safety of pedicle screw placement using 3D-printed auxiliary guides in scoliosis correction surgery for adolescents.
METHODS:
A retrospective analysis was conducted on the clinical data of 51 patients who underwent posterior scoliosis correction surgery from January 2020 to March 2023. Among them, there were 35 cases of adolescent idiopathic scoliosis and 16 cases of congenital scoliosis. The patients were divided into two groups based on the auxiliary tool used:the 3D-printed auxiliary guide screw placement group (3D printing group) and the free-hand screw placement group (free-hand group, without auxiliary tools). The 3D printing group included 32 patients (12 males and 20 females) with an average age of (12.59±2.60) years;the free-hand group included 19 patients (7 males and 12 females) with an average age of (14.58±3.53) years. The two groups were compared in terms of screw placement accuracy and safety, spinal correction rate, intraoperative blood loss, number of intraoperative fluoroscopies, operation time, hospital stay, and preoperative and last follow-up scores of the Scoliosis Research Society-22 (SRS-22) questionnaire.
RESULTS:
A total of 707 pedicle screws were placed in the two groups, with 441 screws in the 3D printing group and 266 screws in the free-hand group. All patients in both groups successfully completed the surgery. There was a statistically significant difference in operation time between the two groups (P<0.05). The screw placement accuracy rate of the 3D printing group was 95.46% (421/441), among which the Grade A placement rate was 89.34% (394/441);the screw placement accuracy rate of the free-hand group was 86.47% (230/266), with a Grade A placement rate of 73.31% (195/266). There were statistically significant differences in the accuracy of Grade A, B, and C screw placements between the two groups (P<0.05), while no statistically significant differences were observed in intraoperative blood loss, number of fluoroscopies, correction rate, or hospital stay (P>0.05). In the SRS-22 questionnaire scores, the scores of functional status and activity ability, self-image, mental status, and pain of patients in each group at the last follow-up were significantly improved compared with those before surgery (P<0.05), but there were no statistically significant differences in all scores between the two groups (P>0.05).
CONCLUSION
In scoliosis correction surgery, compared with traditional free-hand screw placement, the use of 3D-printed auxiliary guides for screw placement significantly improves the accuracy and safety of screw placement and shortens the operation time.
Humans
;
Male
;
Scoliosis/surgery*
;
Female
;
Adolescent
;
Printing, Three-Dimensional
;
Retrospective Studies
;
Pedicle Screws
;
Child
8.Complications among patients undergoing orthopedic surgery after infection with the SARS-CoV-2 Omicron strain and a preliminary nomogram for predicting patient outcomes.
Liang ZHANG ; Wen-Long GOU ; Ke-Yu LUO ; Jun ZHU ; Yi-Bo GAN ; Xiang YIN ; Jun-Gang PU ; Huai-Jian JIN ; Xian-Qing ZHANG ; Wan-Fei WU ; Zi-Ming WANG ; Yao-Yao LIU ; Yang LI ; Peng LIU
Chinese Journal of Traumatology 2025;28(6):445-453
PURPOSE:
The rate of complications among patients undergoing surgery has increased due to infection with SARS-CoV-2 and other variants of concern. However, Omicron has shown decreased pathogenicity, raising questions about the risk of postoperative complications among patients who are infected with this variant. This study aimed to investigate complications and related factors among patients with recent Omicron infection prior to undergoing orthopedic surgery.
METHODS:
A historical control study was conducted. Data were collected from all patients who underwent surgery during 2 distinct periods: (1) between Dec 12, 2022 and Jan 31, 2023 (COVID-19 positive group), (2) between Dec 12, 2021 and Jan 31, 2022 (COVID-19 negative control group). The patients were at least 18 years old. Patients who received conservative treatment after admission or had high-risk diseases or special circumstances (use of anticoagulants before surgery) were excluded from the study. The study outcomes were the total complication rate and related factors. Binary logistic regression analysis was used to identify related factors, and odds ratio (OR) and 95% confidence interval (CI) were calculated to assess the impact of COVID-19 infection on complications.
RESULTS:
In the analysis, a total of 847 patients who underwent surgery were included, with 275 of these patients testing positive for COVID-19 and 572 testing negative. The COVID-19-positive group had a significantly higher rate of total complications (11.27%) than the control group (4.90%, p < 0.001). After adjusting for relevant factors, the OR was 3.08 (95% CI: 1.45-6.53). Patients who were diagnosed with COVID-19 at 3-4 weeks (OR = 0.20 (95% CI: 0.06-0.59), p = 0.005), 5-6 weeks (OR = 0.16 (95% CI: 0.04-0.59), p = 0.010), or ≥7 weeks (OR = 0.26 (95% CI: 0.06-1.02), p = 0.069) prior to surgery had a lower risk of complications than those who were diagnosed at 0-2 weeks prior to surgery. Seven factors (age, indications for surgery, time of operation, time of COVID-19 diagnosis prior to surgery, C-reactive protein levels, alanine transaminase levels, and aspartate aminotransferase levels) were found to be associated with complications; thus, these factors were used to create a nomogram.
CONCLUSION
Omicron continues to be a significant factor in the incidence of postoperative complications among patients undergoing orthopedic surgery. By identifying the factors associated with these complications, we can determine the optimal surgical timing, provide more accurate prognostic information, and offer appropriate consultation for orthopedic surgery patients who have been infected with Omicron.
Humans
;
COVID-19/complications*
;
Male
;
Female
;
Middle Aged
;
Postoperative Complications/epidemiology*
;
SARS-CoV-2
;
Orthopedic Procedures/adverse effects*
;
Aged
;
Nomograms
;
Adult
;
Retrospective Studies
;
Risk Factors
9.Association between insulin resistance and uterine volume in girls with idiopathic central precocious puberty.
Hong-Ru ZHANG ; Ya XIAO ; Shu-Qin JIANG ; Jun SUN ; Wen-Hui SHI ; Jin-Bo LI ; Ying YANG ; Wei WANG
Chinese Journal of Contemporary Pediatrics 2025;27(4):404-409
OBJECTIVES:
To investigate the association between insulin resistance and uterine volume in girls with idiopathic central precocious puberty (ICPP).
METHODS:
A retrospective study was conducted involving 61 girls diagnosed with ICPP who visited the pediatric growth and development clinic of the Third Affiliated Hospital of Zhengzhou University between January 2022 and September 2024, designated as the ICPP group, and 61 normally developing girls as the control group. The differences in insulin resistance index (homeostasis model assessment of insulin resistance, HOMA-IR), uterine volume, and other indicators between the two groups were compared, and the relationship between insulin resistance and uterine volume in these girls was analyzed.
RESULTS:
The uterine volume and HOMA-IR level in the ICPP group were significantly higher than those in the control group (P<0.05). Correlation analysis revealed that there was a positive correlation between HOMA-IR level and uterine volume in the ICPP group (rs=0.643, P<0.001). Multiple linear regression analysis indicated that as HOMA-IR increased,uterine volume in the girls tended to increase (P<0.05).
CONCLUSIONS
There is an association between insulin resistance and uterine volume in girls with ICPP, and as HOMA-IR increases, uterine volume in the girls also increases.
Humans
;
Female
;
Insulin Resistance
;
Puberty, Precocious/metabolism*
;
Uterus/pathology*
;
Child
;
Retrospective Studies
;
Organ Size
;
Linear Models
10.Clinical and genetic characteristics of congenital adrenal hyperplasia: a retrospective analysis.
Cai-Jun WANG ; Ya-Wei ZHANG ; Da-Peng LIU ; Juan JIN ; Zhao-Hui LI ; Jing GUO ; Yao-Dong ZHANG ; Hai-Hua YANG ; Wen-Qing KANG
Chinese Journal of Contemporary Pediatrics 2025;27(11):1367-1372
OBJECTIVES:
To study the clinical and genetic characteristics of children with congenital adrenal hyperplasia (CAH).
METHODS:
Clinical data, laboratory findings, and genetic test results of 63 children diagnosed with CAH at Henan Children's Hospital from January 2017 to December 2024 were retrospectively reviewed.
RESULTS:
Of the 63 patients, the mean age at the first visit was (21 ± 14) days; 29 (46%) were of male sex and 34 (54%) were of female sex. The predominant clinical manifestations were poor weight gain or weight loss (92%, 58/63), poor feeding (84%, 53/63), skin hyperpigmentation (83%, 52/63), and female external genital anomalies (100%, 34/34). Laboratory abnormalities included hyponatremia (87%, 55/63), hyperkalemia (68%, 43/63), metabolic acidosis (68%, 43/63), and markedly elevated 17-hydroxyprogesterone (92%, 58/63), testosterone (89%, 56/63), and adrenocorticotropic hormone (81%, 51/63). Among 49 patients who underwent genetic testing, CYP21A2 variants were identified in 90% (44/49), with c.293-13A/C>G (33%, 30/91) and large deletions/gene conversions (29%, 26/91) being the most frequent; STAR (8%, 4/49) and HSD3B2 (2%, 1/49) variants were also detected. Following hormone replacement therapy, electrolyte disturbances were corrected in 57 cases, with significant reductions in 17-hydroxyprogesterone, adrenocorticotropic hormone, and testosterone levels (P<0.001).
CONCLUSIONS
CAH presenting in neonates or young infants is characterized by electrolyte imbalance, external genital anomalies, and abnormal hormone levels. Genetic testing enables definitive subtype classification; in CYP21A2-related CAH, c.293-13A/C>G is a hotspot variant. These findings underscore the clinical value of genetic testing for early diagnosis and genetic counseling in CAH. Citation:Chinese Journal of Contemporary Pediatrics, 2025, 27(11): 1367-1372.
Humans
;
Adrenal Hyperplasia, Congenital/diagnosis*
;
Male
;
Female
;
Retrospective Studies
;
Infant
;
Infant, Newborn

Result Analysis
Print
Save
E-mail