1.Effect and mechanism of triptolide in alleviating depression induced by corticosterone in mice via CREB/BDNF/TrkB signaling pathway
Ya-ru ZHANG ; Yao ZHUANG ; Zhu TAO ; Xue LI ; Shu-min DING ; Jin-peng LYU ; Li LIU
Chinese Pharmacological Bulletin 2025;41(4):677-685
Aim To investigate the effect of triptolide(TP)on corticosterone(CORT)-induced depression-like behaviors in mice and explore the antidepressant mechanism of TP based on the CREB/BDNF/TrkB sig-naling pathway.Methods Sixty 8-week-old male C57BL/6J mice were randomly divided into five groups:control group,CORT group,TP groups of low and high doses(10,30 μg·kg-1),and fluoxetine(FLU)group(10 mg·kg-1).Except for the control group,the other groups received subcutaneous injec-tions of CORT for three consecutive weeks to establish the model of depression.During the last two weeks of modeling,normal saline,TP and FLU were adminis-tered via intraperitoneal injection respectively.After the administration,depression-like behaviors in mice were assessed using forced swimming test,tail suspen-sion test,and sucrose preference test.Biochemical methods were used to measure the levels of SOD and MDA in the hippocampus and prefrontal cortex(PFC).Cell apoptosis was detected by TUNEL meth-od.Immunohistochemistry,immunofluorescence,and Western blotting were employed to detect the expres-sion of apoptosis/autophagy-related proteins,synaptic structure markers,and proteins related to the CREB/BDNF/TrkB signaling pathway.Results TP signifi-cantly ameliorated CORT-induced depression-like be-haviors in mice,mainly manifested by reduced immo-bility time in the tail suspension test and forced swim-ming test,and increased sucrose preference rate.TP alleviated CORT-induced oxidative stress by increasing SOD levels and reducing MDA production in brain tis-sue.Additionally,TP also inhibited apoptosis and ex-cessive autophagy of neurons in the hippocampus and prefrontal cortex,maintained synaptic plasticity,and significantly upregulated the expression of p-CREB,BDNF,and TrkB.Conclusions TP exhibits potential antidepressant effect in mice by upregulating the CREB/BDNF/TrkB signaling pathway,reducing oxida-tive stress,inhibiting excessive neuronal apoptosis and autophagy,and improving synaptic plasticity.
2.Impact of suture configuration and fixation type on biomechanical strength of rotator cuff repair:A factorial design study
Yinzhe CUI ; Zheng YAN ; Jia MA ; Zhefeng JIN ; Jiawen ZHAN ; Minshan FENG ; Guangwei LIU ; Jie YU ; Xu WEI ; Jiangtao SI ; Minghui ZHUANG ; Tao HAN ; Jianguo LI ; ZHANGKAIRUI ; Liguo ZHU
Chinese Journal of Sports Medicine 2025;44(9):729-737
Objective To explore the impact of suture configuration and fixation type on the biome-chanical strength of rotator cuff repair,using a factorial design study.Methods Sixteen fresh-frozen porcine shoulder samples were randomized into an anchorless double-row suture bridge transosseous su-tures(DS)group,an anchored double-row suture bridge transosseous-equivalent(DE)group,an an-chorless X-BOX construct transosseous sutures(XS)group,and an anchored X-BOX construct transos-seous-equivalent(XE)group,each of four,according to suture configuration(double-row suture bridge,traditional X-BOX construct)and fixation type(suture anchors,transosseous sutures).Then,their fatigue resistance(first-cycle excursion,gap length difference ratio,and the percentage of ex-posed footprints)and the failure strength(the maximum failure load and the re-tear type)were mea-sured using a biomechanical material testing machine.Results Different suture configurations affected failure strength(F=39.559,P<0.001),with the double-row suture bridge groups(693.07±58.35 N,746.76±138.57 N)showing significantly higher failure strength,compared to the traditional X-BOX groups(462.90±18.91 N,421.43±90.76 N).However,the fixation type did not significantly im-pact failure strength(F=1.161,P=0.302).Moreover,the suture configuration influenced the gap differ-ence ratio(F=7.781,P=0.016),but had no significant correlation with other fatigue resistance indica-tors(P>0.05).Meanwhile,failure strength and fatigue resistance were not correlated with fixation type,and the interaction between suture and fixation type(P>0.05).The incidence of failure types for the four suture configurations was as follows:Type I tendon tear:XS>XE>DS=DE;type II tendon tear:DS>XE>XS=DE;fixing material-related failure:DE>DS=XE=XS.Conclusion The failure strength and gap formation ratio in rotator cuff repair under fatigue loading are influenced by suture configuration,whereas no significant association has been observed with respect to fixation method,whether using transosseous sutures or suture anchors.
3.Impact of suture configuration and fixation type on biomechanical strength of rotator cuff repair:A factorial design study
Yinzhe CUI ; Zheng YAN ; Jia MA ; Zhefeng JIN ; Jiawen ZHAN ; Minshan FENG ; Guangwei LIU ; Jie YU ; Xu WEI ; Jiangtao SI ; Minghui ZHUANG ; Tao HAN ; Jianguo LI ; ZHANGKAIRUI ; Liguo ZHU
Chinese Journal of Sports Medicine 2025;44(9):729-737
Objective To explore the impact of suture configuration and fixation type on the biome-chanical strength of rotator cuff repair,using a factorial design study.Methods Sixteen fresh-frozen porcine shoulder samples were randomized into an anchorless double-row suture bridge transosseous su-tures(DS)group,an anchored double-row suture bridge transosseous-equivalent(DE)group,an an-chorless X-BOX construct transosseous sutures(XS)group,and an anchored X-BOX construct transos-seous-equivalent(XE)group,each of four,according to suture configuration(double-row suture bridge,traditional X-BOX construct)and fixation type(suture anchors,transosseous sutures).Then,their fatigue resistance(first-cycle excursion,gap length difference ratio,and the percentage of ex-posed footprints)and the failure strength(the maximum failure load and the re-tear type)were mea-sured using a biomechanical material testing machine.Results Different suture configurations affected failure strength(F=39.559,P<0.001),with the double-row suture bridge groups(693.07±58.35 N,746.76±138.57 N)showing significantly higher failure strength,compared to the traditional X-BOX groups(462.90±18.91 N,421.43±90.76 N).However,the fixation type did not significantly im-pact failure strength(F=1.161,P=0.302).Moreover,the suture configuration influenced the gap differ-ence ratio(F=7.781,P=0.016),but had no significant correlation with other fatigue resistance indica-tors(P>0.05).Meanwhile,failure strength and fatigue resistance were not correlated with fixation type,and the interaction between suture and fixation type(P>0.05).The incidence of failure types for the four suture configurations was as follows:Type I tendon tear:XS>XE>DS=DE;type II tendon tear:DS>XE>XS=DE;fixing material-related failure:DE>DS=XE=XS.Conclusion The failure strength and gap formation ratio in rotator cuff repair under fatigue loading are influenced by suture configuration,whereas no significant association has been observed with respect to fixation method,whether using transosseous sutures or suture anchors.
4.Effect and mechanism of triptolide in alleviating depression induced by corticosterone in mice via CREB/BDNF/TrkB signaling pathway
Ya-ru ZHANG ; Yao ZHUANG ; Zhu TAO ; Xue LI ; Shu-min DING ; Jin-peng LYU ; Li LIU
Chinese Pharmacological Bulletin 2025;41(4):677-685
Aim To investigate the effect of triptolide(TP)on corticosterone(CORT)-induced depression-like behaviors in mice and explore the antidepressant mechanism of TP based on the CREB/BDNF/TrkB sig-naling pathway.Methods Sixty 8-week-old male C57BL/6J mice were randomly divided into five groups:control group,CORT group,TP groups of low and high doses(10,30 μg·kg-1),and fluoxetine(FLU)group(10 mg·kg-1).Except for the control group,the other groups received subcutaneous injec-tions of CORT for three consecutive weeks to establish the model of depression.During the last two weeks of modeling,normal saline,TP and FLU were adminis-tered via intraperitoneal injection respectively.After the administration,depression-like behaviors in mice were assessed using forced swimming test,tail suspen-sion test,and sucrose preference test.Biochemical methods were used to measure the levels of SOD and MDA in the hippocampus and prefrontal cortex(PFC).Cell apoptosis was detected by TUNEL meth-od.Immunohistochemistry,immunofluorescence,and Western blotting were employed to detect the expres-sion of apoptosis/autophagy-related proteins,synaptic structure markers,and proteins related to the CREB/BDNF/TrkB signaling pathway.Results TP signifi-cantly ameliorated CORT-induced depression-like be-haviors in mice,mainly manifested by reduced immo-bility time in the tail suspension test and forced swim-ming test,and increased sucrose preference rate.TP alleviated CORT-induced oxidative stress by increasing SOD levels and reducing MDA production in brain tis-sue.Additionally,TP also inhibited apoptosis and ex-cessive autophagy of neurons in the hippocampus and prefrontal cortex,maintained synaptic plasticity,and significantly upregulated the expression of p-CREB,BDNF,and TrkB.Conclusions TP exhibits potential antidepressant effect in mice by upregulating the CREB/BDNF/TrkB signaling pathway,reducing oxida-tive stress,inhibiting excessive neuronal apoptosis and autophagy,and improving synaptic plasticity.
5.Application of Rotarex catheter system in femoropopliteal artery stenosis accompanied with thrombosis.
Jin Man ZHUANG ; Tian Run LI ; Xuan LI ; Jing Yuan LUAN ; Chang Ming WANG ; Qi Chen FENG ; Jin Tao HAN
Journal of Peking University(Health Sciences) 2023;55(2):328-332
OBJECTIVE:
To evaluate the effectiveness and safety of Rotarex catheter system in treating femoropopliteal artery stenosis accompanied with thrombosis.
METHODS:
From Jun. 2017 to Dec. 2019, the clinical data of 32 femoropopliteal artery stenosis accompanied with thrombosis cases treated with Rotarex catheter system were retrospectively analyzed. There were 23 males and 9 females aged from 50 to 89 years and the mean age was (70.7±10.3) years. Six cases had acute course of disease (≤2 weeks), 17 cases had subacute course of disease (>2 weeks, ≤3 months), and 9 cases had chronic course of disease (>3 months). Mean lesion length was (23.4±13.7) cm, mean occlusion length was (19.9±13.3) cm, and in-stent occlusion 7 cases. The superficial femoral artery (SFA) was involved in 13 cases, the popliteal artery (PA) was involved in 8 cases, and both SFA and PA were involved in the other 11 cases. All the cases were treated with Rotarex catheter system. When necessary, suction with large lumen catheter was enabled. Residual stenosis was treated with percutaneous transluminal angioplasty (PTA). Drug-coated balloon (DCB) was only used in patients with financial status, and stent was used only when it was necessary. Heparin was used for 24 h after procedures, and after that, antiplatelet agents were used. Doppler ultrasonography was taken during the followed-up.
RESULTS:
Technical success was 100%, and mean procedure time was (107.4±21.5) min. 8F (1F≈0.33 mm) and 6F Rotarex catheter were used in 27 and 5 cases respectively. In 27 cases, forward flow was obtained immediately after debulking with Rotarex catheter, and in the other 5 cases, suction with large lumen catheters were used. PTA was used in all 32 cases. DCB were used in 8 cases, of which 4 were used in in-stent stenosis. Twelve cases were implanted stents. There were no perioperative deaths. The only one procedure related complication was distal embolism. We took out the thrombus with guiding catheter. In all cases, mean hospital stay were (4.6±1.5) d. The ankle brachial index increased from 0.32±0.15 to 0.86±0.10 after treatment (t=-16.847, P < 0.001). The Rutherford stages decreased significantly (Z=-4.518, P < 0.001). All the patients were followed up for 6.0-36.0 months, and the median time was 16.0 months. 2 cases stopped antiplatelet agents, which resulted in acute thrombosis. Another percutaneous mechanical thrombectomy and PTA were taken in one of them. Two cases died of cardiovascular disease during the follow-up, and no amputation was observed. Target lesion restenosis occurred in 7 cases during the follow-up, and target lesion revascularization (TLR) was taken in two of them.
CONCLUSION
In treating femoropopliteal artery stenosis accompanied with thrombosis, Rotarex catheter can remove thrombus effectively, and that can expose underlying lesions and reduce stent use and complications rates. It is a safe and effective method.
Male
;
Female
;
Humans
;
Middle Aged
;
Aged
;
Aged, 80 and over
;
Femoral Artery/surgery*
;
Retrospective Studies
;
Constriction, Pathologic
;
Platelet Aggregation Inhibitors
;
Treatment Outcome
;
Thrombosis
;
Catheters
6.HbA1c comparison and diagnostic efficacy analysis of multi center different glycosylated hemoglobin detection systems.
Ping LI ; Ying WU ; Yan XIE ; Feng CHEN ; Shao qiang CHEN ; Yun Hao LI ; Qing Qing LU ; Jing LI ; Yong Wei LI ; Dong Xu PEI ; Ya Jun CHEN ; Hui CHEN ; Yan LI ; Wei WANG ; Hai WANG ; He Tao YU ; Zhu BA ; De CHENG ; Le Ping NING ; Chang Liang LUO ; Xiao Song QIN ; Jin ZHANG ; Ning WU ; Hui Jun XIE ; Jina Hua PAN ; Jian SHUI ; Jian WANG ; Jun Ping YANG ; Xing Hui LIU ; Feng Xia XU ; Lei YANG ; Li Yi HU ; Qun ZHANG ; Biao LI ; Qing Lin LIU ; Man ZHANG ; Shou Jun SHEN ; Min Min JIANG ; Yong WU ; Jin Wei HU ; Shuang Quan LIU ; Da Yong GU ; Xiao Bing XIE
Chinese Journal of Preventive Medicine 2023;57(7):1047-1058
Objective: Compare and analyze the results of the domestic Lanyi AH600 glycated hemoglobin analyzer and other different detection systems to understand the comparability of the detection results of different detectors, and establish the best cut point of Lanyi AH600 determination of haemoglobin A1c (HbA1c) in the diagnosis of diabetes. Methods: Multi center cohort study was adopted. The clinical laboratory departments of 18 medical institutions independently collected test samples from their respective hospitals from March to April 2022, and independently completed comparative analysis of the evaluated instrument (Lanyi AH600) and the reference instrument HbA1c. The reference instruments include four different brands of glycosylated hemoglobin meters, including Arkray, Bio-Rad, DOSOH, and Huizhong. Scatter plot was used to calculate the correlation between the results of different detection systems, and the regression equation was calculated. The consistency analysis between the results of different detection systems was evaluated by Bland Altman method. Consistency judgment principles: (1) When the 95% limits of agreement (95% LoA) of the measurement difference was within 0.4% HbA1c and the measurement score was≥80 points, the comparison consistency was good; (2) When the measurement difference of 95% LoA exceeded 0.4% HbA1c, and the measurement score was≥80 points, the comparison consistency was relatively good; (3) The measurement score was less than 80 points, the comparison consistency was poor. The difference between the results of different detection systems was tested by paired sample T test or Wilcoxon paired sign rank sum test; The best cut-off point of diabetes was analyzed by receiver operating characteristic curve (ROC). Results: The correlation coefficient R2 of results between Lanyi AH600 and the reference instrument in 16 hospitals is≥0.99; The Bland Altman consistency analysis showed that the difference of 95% LoA in Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180) was -0.486%-0.325%, and the measurement score was 94.6 points (473/500); The difference of 95% LoA in the Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant II) was -0.727%-0.612%, and the measurement score was 89.8 points; The difference of 95% LoA in the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT) was -0.231%-0.461%, and the measurement score was 96.6 points; The difference of 95% LoA in the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT) was -0.469%-0.479%, and the measurement score was 91.9 points. The other 14 hospitals, Lanyi AH600, were compared with 4 reference instrument brands, the difference of 95% LoA was less than 0.4% HbA1c, and the scores were all greater than 95 points. The results of paired sample T test or Wilcoxon paired sign rank sum test showed that there was no statistically significant difference between Lanyi AH600 and the reference instrument Arkray HA8180 (Z=1.665,P=0.096), with no statistical difference. The mean difference between the measured values of the two instruments was 0.004%. The comparison data of Lanyi AH600 and the reference instrument of all other institutions had significant differences (all P<0.001), however, it was necessary to consider whether it was within the clinical acceptable range in combination with the results of the Bland-Altman consistency analysis. The ROC curve of HbA1c detected by Lanyi AH600 in 985 patients with diabetes and 3 423 patients with non-diabetes was analyzed, the area under curve (AUC) was 0.877, the standard error was 0.007, and the 95% confidence interval 95%CI was (0.864, 0.891), which was statistically significant (P<0.001). The maximum value of Youden index was 0.634, and the corresponding HbA1c cut point was 6.235%. The sensitivity and specificity of diabetes diagnosis were 76.2% and 87.2%, respectively. Conclusion: Among the hospitals and instruments currently included in this study, among these four hospitals included Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180), Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant Ⅱ), the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT), and the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT), the comparison between Lanyi AH600 and the reference instruments showed relatively good consistency, while the other 14 hospitals involved four different brands of reference instruments: Arkray, Bio-Rad, DOSOH, and Huizhong, Lanyi AH600 had good consistency with its comparison. The best cut point of the domestic Lanyi AH600 for detecting HbA1c in the diagnosis of diabetes is 6.235%.
Pregnancy
;
Child
;
Humans
;
Female
;
Glycated Hemoglobin
;
Cohort Studies
;
Diabetes Mellitus/diagnosis*
;
Sensitivity and Specificity
;
ROC Curve
7.A randomized controlled trial on sodium hyaluronate gel in prevention of postoperative intestinal adhesion
Wensheng HUANG ; Jiancong HU ; Chuanqing WU ; Liang SHANG ; Chengle ZHUANG ; Ke AN ; Zhichao ZHAI ; Changmin DING ; Zhaoya GAO ; Qingkun GAO ; Pengfei NIU ; Yanzhao WANG ; Qingmin ZENG ; Yuming HONG ; Wanshui RONG ; Fuming LEI ; Zhongchen LIU ; Leping LI ; Kaixiong TAO ; Xiaojian WU ; Jin GU
Chinese Journal of General Surgery 2023;38(11):809-813
Objective:To evaluate the efficacy and safety of sodium hyaluronate gel in preventing adhesion after prophylactic enterostomy.Methods:One hundred and twenty four patients from 6 hospitals were enrolled in this prospective multi-center randomized controlled trial. Patients were randomized into the study group ( n=59) or the control group ( n=65).All patients underwent prophylactic enterostomy. Patients of study group received odium hyaluronate gel for adhesion-prevention,while those in control group did not receive any adhesion-prevention treatment. The incidence of moderate to severe adhesion around the incision in the stoma area were evalutated during stoma reduction surgery. Results:The incidence of moderate to severe adhesion around the incision in the stoma area was 6.3% in the study group, the difference was statistically significant ( P<0.05) compared to that of the control group (32.6%). Conclusion:Sodium hyaluronate gel can safely and effectively reduce the incidence of moderate and severe adhesions after abdominal surgery.
8.Diagnosis and treatment procedures and health management for patients with hereditary angioedema.
Min ZHOU ; Xin LUO ; Qi Lin ZHOU ; Wen Hao ZHOU ; Rui ZHENG ; Ya Na ZHANG ; Xi Fu WU ; Shuo WU ; Jing SU ; Guo Wei XIONG ; Yun CHENG ; Ya Ting LI ; Ping Ping ZHANG ; Kun ZHANG ; Min DAI ; Xue Kun HUANG ; Zhao Hui SHI ; Jin TAO ; Yu Qi ZHOU ; Pei Ying FENG ; Zhuang Gui CHEN ; Qin Tai YANG
Chinese Journal of Preventive Medicine 2023;57(8):1280-1285
As a recognized rare and highly fatal disease, hereditary angioedema (HAE) is difficult to diagnose and characterized by recurrent edema involving the head, limbs, genitals and larynx, etc. Diagnosis of HAE is not difficult. However, low incidence and lack of clinical characteristics lead to difficulty of doctors on timely diagnosis and correct intervention for HAE patients. Therefore, it is crucial to improve the awareness of this disease and prevent its recurrence. for HAE patients. In view of absent cognition of doctors and the general public on HAE, patients often suffer from sudden death or become disabled due to laryngeal edema which cannot be treated in time. Thus, based on the Internet mobile terminal platform, the team set up an all-day rapid emergency response system which is provided for HAE patients by setting up "one-click help". The aim is to offer optimization on overall management of HAE and designed the intelligent follow-up management to provide timely assistance and specialized suggestion for patients with acute attacks.
Humans
;
Angioedemas, Hereditary/drug therapy*
9.Preliminary insights into the practice of hypoallergenic home visiting program.
He ZHANG ; Min ZHOU ; Qi Lin ZHOU ; Xin LUO ; Rui ZHENG ; Jing SU ; Guo Wei XIONG ; Yun CHENG ; Ya Ting LI ; Ping Ping ZHANG ; Kun ZHANG ; Min DAI ; Xue Kun HUANG ; Ya Na ZHANG ; Zhao Hui SHI ; Jin TAO ; Yu Qi ZHOU ; Pei Ying FENG ; Zhuang Gui CHEN ; Qin Tai YANG
Chinese Journal of Preventive Medicine 2023;57(12):1957-1963
Allergic diseases affect about 40% of the world's population. Environmental factors are important in the occurrence and development of allergic diseases. Dust mites are one of the most important allergens in the indoor environment. The World Health Organization proposes the "four-in-one, combination of prevention and treatment" treatment principle for allergic diseases, in which environmental control to avoid or reduce allergens is the first choice for treatment. Modern people spend much more time at home (including sleeping) than outdoors, and the control of the home environment is particularly critical. This practice introduces the hypoallergenic home visit program, which including home environment assessment, environmental and behavioral intervention guidance, and common household hypoallergenic supplies and service guidance for the patient's home environment. The real-time semi-quantitative testing of dust mite allergens, qualitative assessments of other indoor allergens, record of patients' household items and lifestyle, and precise, individualized patient prevention and control education will be conducted. The hypoallergenic home visit program improves the doctors' diagnosis and treatment data dimension, and becomes a patient management tool for doctors outside the hospital. It also helps patients continue to scientifically avoid allergens and irritants in the environment, effectively build a hypoallergenic home environment, reduce exposure to allergens in the home environment, and achieve the goal of combining the prevention and treatment of allergic diseases.
Humans
;
Hospitals
;
Life Style
;
Sleep
10.Diagnosis and treatment procedures and health management for patients with hereditary angioedema.
Min ZHOU ; Xin LUO ; Qi Lin ZHOU ; Wen Hao ZHOU ; Rui ZHENG ; Ya Na ZHANG ; Xi Fu WU ; Shuo WU ; Jing SU ; Guo Wei XIONG ; Yun CHENG ; Ya Ting LI ; Ping Ping ZHANG ; Kun ZHANG ; Min DAI ; Xue Kun HUANG ; Zhao Hui SHI ; Jin TAO ; Yu Qi ZHOU ; Pei Ying FENG ; Zhuang Gui CHEN ; Qin Tai YANG
Chinese Journal of Preventive Medicine 2023;57(8):1280-1285
As a recognized rare and highly fatal disease, hereditary angioedema (HAE) is difficult to diagnose and characterized by recurrent edema involving the head, limbs, genitals and larynx, etc. Diagnosis of HAE is not difficult. However, low incidence and lack of clinical characteristics lead to difficulty of doctors on timely diagnosis and correct intervention for HAE patients. Therefore, it is crucial to improve the awareness of this disease and prevent its recurrence. for HAE patients. In view of absent cognition of doctors and the general public on HAE, patients often suffer from sudden death or become disabled due to laryngeal edema which cannot be treated in time. Thus, based on the Internet mobile terminal platform, the team set up an all-day rapid emergency response system which is provided for HAE patients by setting up "one-click help". The aim is to offer optimization on overall management of HAE and designed the intelligent follow-up management to provide timely assistance and specialized suggestion for patients with acute attacks.
Humans
;
Angioedemas, Hereditary/drug therapy*

Result Analysis
Print
Save
E-mail