1.Hemolysis rates of three red blood cell components at the end of storage: a 5-year retrospective study
Zhenping LU ; Fufa LIU ; Meiyan KANG ; Xianbin WU ; Yanting WANG ; Xing LONG ; Xinlu QIU ; Jin LI
Chinese Journal of Blood Transfusion 2025;38(6):828-832
Objective: To evaluate the suitability of the existing hemolysis rate standards for locally processed red blood cell components by retrospectively analyzing 5-year hemolysis rate data at the end of storage. Methods: A total of 720 blood samples of three types of red blood cell components from our blood station from January 2019 to December 2023 were collected. Parameters included hemoglobin concentration (Hb), hematocrit (Hct), and free hemoglobin concentration (fHb). Hemolysis rate were taken as the control standard of 0.8% in accordance with the national standard. The hemolysis rates were compared against the national standard threshold of 0.8% (GB18469-2012), and annual trends of the detection parameters were observed. Results: The hemolysis rates (x-+s,%) of leukocyte-depleted whole blood at the end of storage were (0.038±0.023 8) in 2019, (0.049±0.039 5) in 2020, (0.043±0.040 7) in 2021, (0.049±0.030 7) in 2022, and (0.058±0.054 8) in 2023, respectively; The hemolysis rates (x-+s" />,%) of leukocyte-depleted suspended red blood cells at the end of storage were (0.093±0.050 2) in 2019, (0.086±0.049 5) in 2020, (0.123±0.072 3) in 2021, (0.122±0.052 1) in 2022, and (0.106±0.058 6) in 2023, respectively; The hemolysis rates (x-+s,%) of washed red blood cells at the end of storage were (0.127±0.038 2) in 2019, (0.150±0.066 5) in 2020, (0.121±0.052 2) in 2021, (0.124±0.038 9) in 2022, and (0.128±0.044 3) in 2023, respectively. Conclusion: Hemolysis rates at the end of blood storage of three red blood cell components were significantly lower than the limits specified in Quality Requirements for Whole Blood and Components (GB18469-2012), as well as standards from the EU, AABB and the United States. The results demonstrate excellent product quality control. A regional internal control standard of <0.2% is proposed for hemolysis rates at the end of storage.
2.Shenmai Injection Reduces Cardiomyocyte Apoptosis Induced by Doxorubicin through miR-30a/Bcl-2.
Xiao-Nan ZHANG ; Yan-Yang LI ; Shi-Chao LYU ; Qiu-Jin JIA ; Jun-Ping ZHANG ; Long-Tao LIU
Chinese journal of integrative medicine 2025;31(3):240-250
OBJECTIVE:
To explore the molecular mechanism of Shenmai Injection (SMI) against doxorubicin (DOX) induced cardiomyocyte apoptosis.
METHODS:
A total of 40 specific pathogen-free (SPF) male Sprague Dawley (SD) male rats were divided into 5 groups based on the random number table, including the control group, the model group, miR-30a agomir group, SMI low-dose (SMI-L) group, and SMI high-dose (SMI-H) group, with 8 rats in each group. Except for the control group, the rats were injected weekly with DOX (2 mg/kg) in the tail vein for 4 weeks to induce myocardial injury, and were given different regimens of continuous intervention for 2 weeks. Cardiac function was detected by echocardiography and myocardial pathological changes were observed by Van Gieson (VG) staining. Myocardial injury serum markers, including creatine kinase (CK), lactate dehydrogenase (LDH), troponin T (cTnT), N-terminal pro-brain natriuretic peptide (NT-proBNP), soluble ST2 (sST2), and growth differentiation factor-15 (GDF-15) were detected by enzyme linked immunosorbent assay (ELISA). Cardiomyocyte apoptosis was observed by terminal deoxynucleotidyl transferase-mediated biotinylated dUTP triphosphate nick end labeling (TUNEL) and transmission electron microscopy, and the expressions of target proteins and mRNA were detected by Western blot and quantitative real time polymerase chain reaction (qRT-RCR), respectively.
RESULTS:
The treatment with different doses of SMI reduced rat heart mass index and left ventricular mass index (P<0.05), significantly improved the left ventricular ejection fraction (P<0.05), decreased the levels of serum CK, LDH, cTnT, and NT-proBNP (P<0.05 or P<0.01), reduced the levels of serum sST2 and GDF-15 (P<0.05 or P<0.01), decreased the collagen volume fraction, reduced the expressions of rat myocardial type I and type III collagen (P<0.05 or P<0.01), and effectively alleviated myocardial fibrosis. And the study found that SMI promoted the expression levels of miR-30a and Bcl-2 in myocardium, and down-regulated the expression of Bax, which inhibited the activation of Caspase-3 and Caspase-9 (P<0.05 or P<0.01), and improved myocardial cell apoptosis.
CONCLUSIONS
SMI can alleviate myocardial injury and apoptosis caused by DOX, and its mechanism possibly by promoting the targeted expression of myocardial Bcl-2 protein through miR-30a.
Animals
;
Myocytes, Cardiac/metabolism*
;
Apoptosis/drug effects*
;
MicroRNAs/genetics*
;
Rats, Sprague-Dawley
;
Male
;
Drugs, Chinese Herbal/administration & dosage*
;
Doxorubicin/pharmacology*
;
Proto-Oncogene Proteins c-bcl-2/genetics*
;
Drug Combinations
;
Injections
;
Rats
3.Investigation on vehicle occupant dummy applicability for under-foot impact loading conditions
Teng-Fei TIAN ; Fu-Hao MO ; Hao-Yang SU ; Can HUANG ; Hui ZHAO ; Jun LIU ; Bo SHANG ; Kui LI ; Jin-Long QIU
Chinese Journal of Traumatology 2024;27(4):235-241
Purpose::Under-foot impact loadings can cause serious lower limb injuries in many activities, such as automobile collisions and underbody explosions to military vehicles. The present study aims to compare the biomechanical responses of the mainstream vehicle occupant dummies with the human body lower limb model and analyze their robustness and applicability for assessing lower limb injury risk in underfoot impact loading environments.Methods::The Hybrid III model, the test device for human occupant restraint (THOR) model, and a hybrid human body model with the human active lower limb model were adopted for under-foot impact analysis regarding different impact velocities and initial lower limb postures.Results::The results show that the 2 dummy models have larger peak tibial axial force and higher sensitivity to the impact velocities and initial postures than the human lower limb model. In particular, the Hybrid III dummy model presented extremely larger peak tibial axial forces than the human lower limb model. In the case of minimal difference in tibial axial force, Hybrid III's tibial axial force (7.5 KN) is still 312.5% that of human active lower limb's (2.4 KN). Even with closer peak tibial axial force values, the biomechanical response curve shapes of the THOR model show significant differences from the human lower limb model.Conclusion::Based on the present results, the Hybrid III dummy cannot be used to evaluate the lower limb injury risk in under-foot loading environments. In contrast, potential improvement in ankle biofidelity and related soft tissues of the THOR dummy can be implemented in the future for better applicability.
4.Effect of chemokine CXC ligand 9 on cognitive function impairment in breast cancer patients with brain metastases receiving whole-brain radiotherapy
Cong WANG ; Zhi-Lin ZHANG ; Jin-Qiu LI ; Xiao SONG ; Qiang XI ; Huan MA ; Yong-Peng PANG ; Long TIAN
Medical Journal of Chinese People's Liberation Army 2024;49(11):1281-1288
Objective To investigate the effect of chemokine CXC ligand 9(CXCL9)on cognitive function impairment in patients with breast cancer brain metastases undergoing whole-brain radiotherapy(WBRT)using bioinformatics methods.Methods The mRNA of breast cancer brain metastases datasets GSE43837 and GSE12276 and Alzheimer's disease(AD)dataset GSE161199 were screened and downloaded from GEO database.Limma method and Venn diagrams were used to identify common differentially expressed genes(DEGs),and protein-protein interaction and functional prediction through GeneMANIA website assays were performed.A total of 42 patients with breast cancer brain metastases who first visited the Department of Radiotherapy at the First Affiliated Hospital of Hebei North University from January 2021 to January 2023 were selected.Patients were divided into normal cognitive function group and cognitive function impairment group based on cognitive status.Enzyme-linked immunosorbent assay(ELISA)was employed to detect serum CXCL9 levels one week before and three months after radiotherapy.The mini-mental state examination(MMSE)was used to assess patients'cognitive function.Results The DEGs from datasets GSE43837 and GSE12276 included PKP1,POLDIP2,SPAG5,ALDOC,PTPRZ1,PKIA,TLCD1,CPE,PMP22 and CXCL9.The DEGs from GSE161199 included RPS16,CD79A,LYPD3,RPL28,HBG2,RPL23AP7,TRNR,CXCL9.Venn diagram showed that CXCL9 was a common DEG between breast cancer brain metastasis and AD.Functional enrichment analysis indicated that CXCL9 was involved in cellular responses to chemokines,negative regulation of immune system processes,negative regulation of vascular morphogenesis,Toll-like receptor signaling pathway,nucleotide oligomerization domain(NOD)-like receptor signaling pathway,and JAK-STAT signaling pathway.Before radiotherapy,patients with cognitive function impairment and normal cognitive function accounted for 61.9%and 38.1%,respectively,with a statistically significant difference in MMSE scores[(24.53±2.19)vs.(28.89±1.36),P<0.01].Compared with normal cognitive function group,patients with cognitive function impairment had a significantly increased number of brain metastases and significantly lower Karnofsky performance status(KPS)scores and serum CXCL9 levels(P<0.05).Three months after radiotherapy,patients with cognitive function impairment and normal cognitive function accounted for 47.6%and 52.4%,respectively,with a statistically significant difference in MMSE scores[(25.16±1.98)vs.(28.18±1.08),P<0.01].Compared with normal cognitive function group,patients with cognitive function impairment had significantly lower CXCL9 levels(P=0.003).In patients with normal cognitive function,CXCL9 levels were remarkably lower after radiotherapy compared to those before radiotherapy(P=0.009).Conclusions Patients with cognitive function impairment had significantly lower CXCL9 levels than those with normal cognitive function,and whole-brain radiotherapy may be related to a certain degree of reduction in CXCL9 levels.
5.Value of contrast-enhanced ultrasonography in microwave ablation treatment of symptomatic focal uterine adenomyosis
Xiao-Long LI ; Jia-Xin LI ; Song-Yuan YU ; Pei-Li FAN ; Yun-Jie JIN ; Er-Jiao XU ; Sai-Nan GUAN ; Er-Ya DENG ; Qiu-Yan LI ; Zheng-Biao JI ; Jiu-Ling QI ; Hui-Xiong XU ;
Ultrasonography 2024;43(1):68-77
Purpose:
This study evaluated the value of contrast-enhanced ultrasonography (CEUS) in the ultrasound-guided microwave ablation (MWA) treatment of symptomatic focal uterine adenomyosis.
Methods:
This retrospective study was conducted between March 2020 and January 2023, enrolling 52 patients with symptomatic focal uterine adenomyosis who had undergone MWA. All patients were examined with CEUS before and after MWA. The non-perfused volume (NPV) was compared between CEUS and dynamic contrast-enhanced magnetic resonance imaging (DCEMRI) following ablation. Therapeutic efficacy and safety were evaluated at 3-, 6-, and 12-month follow-ups. Additionally, this study explored the correlations between pre-treatment CEUS features and a volume reduction ratio indicating sufficient ablation, defined as 50% or more at the 3-month follow-up.
Results:
No significant differences in NPV were noted between CEUS and DCE-MRI immediately after MWA and during follow-up (all P>0.05). At the 3-month follow-up, the median VRRs for the uterus and adenomyosis were 33.2% and 63.9%, respectively. Sufficient ablation was achieved in 69.2% (36/52) of adenomyosis cases, while partial ablation was observed in the remaining 30.8% (16/52). The identification of non-enhancing areas on pre-treatment CEUS was associated with sufficient ablation (P=0.016). At the 12-month follow-up, significant decreases were observed in both the uterine and adenomyosis volumes (all P<0.001). Dysmenorrhea and menorrhagia were significantly alleviated at 12 months, and no major complications were encountered.
Conclusion
CEUS can be used to evaluate the ablation zone of focal adenomyosis that has been treated with MWA, similarly to DCE-MRI. The identification of non-enhancing areas on pretreatment CEUS indicates satisfactory treatment outcomes.
6.Value of contrast-enhanced ultrasonography in microwave ablation treatment of symptomatic focal uterine adenomyosis
Xiao-Long LI ; Jia-Xin LI ; Song-Yuan YU ; Pei-Li FAN ; Yun-Jie JIN ; Er-Jiao XU ; Sai-Nan GUAN ; Er-Ya DENG ; Qiu-Yan LI ; Zheng-Biao JI ; Jiu-Ling QI ; Hui-Xiong XU ;
Ultrasonography 2024;43(1):68-77
Purpose:
This study evaluated the value of contrast-enhanced ultrasonography (CEUS) in the ultrasound-guided microwave ablation (MWA) treatment of symptomatic focal uterine adenomyosis.
Methods:
This retrospective study was conducted between March 2020 and January 2023, enrolling 52 patients with symptomatic focal uterine adenomyosis who had undergone MWA. All patients were examined with CEUS before and after MWA. The non-perfused volume (NPV) was compared between CEUS and dynamic contrast-enhanced magnetic resonance imaging (DCEMRI) following ablation. Therapeutic efficacy and safety were evaluated at 3-, 6-, and 12-month follow-ups. Additionally, this study explored the correlations between pre-treatment CEUS features and a volume reduction ratio indicating sufficient ablation, defined as 50% or more at the 3-month follow-up.
Results:
No significant differences in NPV were noted between CEUS and DCE-MRI immediately after MWA and during follow-up (all P>0.05). At the 3-month follow-up, the median VRRs for the uterus and adenomyosis were 33.2% and 63.9%, respectively. Sufficient ablation was achieved in 69.2% (36/52) of adenomyosis cases, while partial ablation was observed in the remaining 30.8% (16/52). The identification of non-enhancing areas on pre-treatment CEUS was associated with sufficient ablation (P=0.016). At the 12-month follow-up, significant decreases were observed in both the uterine and adenomyosis volumes (all P<0.001). Dysmenorrhea and menorrhagia were significantly alleviated at 12 months, and no major complications were encountered.
Conclusion
CEUS can be used to evaluate the ablation zone of focal adenomyosis that has been treated with MWA, similarly to DCE-MRI. The identification of non-enhancing areas on pretreatment CEUS indicates satisfactory treatment outcomes.
7.Value of contrast-enhanced ultrasonography in microwave ablation treatment of symptomatic focal uterine adenomyosis
Xiao-Long LI ; Jia-Xin LI ; Song-Yuan YU ; Pei-Li FAN ; Yun-Jie JIN ; Er-Jiao XU ; Sai-Nan GUAN ; Er-Ya DENG ; Qiu-Yan LI ; Zheng-Biao JI ; Jiu-Ling QI ; Hui-Xiong XU ;
Ultrasonography 2024;43(1):68-77
Purpose:
This study evaluated the value of contrast-enhanced ultrasonography (CEUS) in the ultrasound-guided microwave ablation (MWA) treatment of symptomatic focal uterine adenomyosis.
Methods:
This retrospective study was conducted between March 2020 and January 2023, enrolling 52 patients with symptomatic focal uterine adenomyosis who had undergone MWA. All patients were examined with CEUS before and after MWA. The non-perfused volume (NPV) was compared between CEUS and dynamic contrast-enhanced magnetic resonance imaging (DCEMRI) following ablation. Therapeutic efficacy and safety were evaluated at 3-, 6-, and 12-month follow-ups. Additionally, this study explored the correlations between pre-treatment CEUS features and a volume reduction ratio indicating sufficient ablation, defined as 50% or more at the 3-month follow-up.
Results:
No significant differences in NPV were noted between CEUS and DCE-MRI immediately after MWA and during follow-up (all P>0.05). At the 3-month follow-up, the median VRRs for the uterus and adenomyosis were 33.2% and 63.9%, respectively. Sufficient ablation was achieved in 69.2% (36/52) of adenomyosis cases, while partial ablation was observed in the remaining 30.8% (16/52). The identification of non-enhancing areas on pre-treatment CEUS was associated with sufficient ablation (P=0.016). At the 12-month follow-up, significant decreases were observed in both the uterine and adenomyosis volumes (all P<0.001). Dysmenorrhea and menorrhagia were significantly alleviated at 12 months, and no major complications were encountered.
Conclusion
CEUS can be used to evaluate the ablation zone of focal adenomyosis that has been treated with MWA, similarly to DCE-MRI. The identification of non-enhancing areas on pretreatment CEUS indicates satisfactory treatment outcomes.
8.Value of contrast-enhanced ultrasonography in microwave ablation treatment of symptomatic focal uterine adenomyosis
Xiao-Long LI ; Jia-Xin LI ; Song-Yuan YU ; Pei-Li FAN ; Yun-Jie JIN ; Er-Jiao XU ; Sai-Nan GUAN ; Er-Ya DENG ; Qiu-Yan LI ; Zheng-Biao JI ; Jiu-Ling QI ; Hui-Xiong XU ;
Ultrasonography 2024;43(1):68-77
Purpose:
This study evaluated the value of contrast-enhanced ultrasonography (CEUS) in the ultrasound-guided microwave ablation (MWA) treatment of symptomatic focal uterine adenomyosis.
Methods:
This retrospective study was conducted between March 2020 and January 2023, enrolling 52 patients with symptomatic focal uterine adenomyosis who had undergone MWA. All patients were examined with CEUS before and after MWA. The non-perfused volume (NPV) was compared between CEUS and dynamic contrast-enhanced magnetic resonance imaging (DCEMRI) following ablation. Therapeutic efficacy and safety were evaluated at 3-, 6-, and 12-month follow-ups. Additionally, this study explored the correlations between pre-treatment CEUS features and a volume reduction ratio indicating sufficient ablation, defined as 50% or more at the 3-month follow-up.
Results:
No significant differences in NPV were noted between CEUS and DCE-MRI immediately after MWA and during follow-up (all P>0.05). At the 3-month follow-up, the median VRRs for the uterus and adenomyosis were 33.2% and 63.9%, respectively. Sufficient ablation was achieved in 69.2% (36/52) of adenomyosis cases, while partial ablation was observed in the remaining 30.8% (16/52). The identification of non-enhancing areas on pre-treatment CEUS was associated with sufficient ablation (P=0.016). At the 12-month follow-up, significant decreases were observed in both the uterine and adenomyosis volumes (all P<0.001). Dysmenorrhea and menorrhagia were significantly alleviated at 12 months, and no major complications were encountered.
Conclusion
CEUS can be used to evaluate the ablation zone of focal adenomyosis that has been treated with MWA, similarly to DCE-MRI. The identification of non-enhancing areas on pretreatment CEUS indicates satisfactory treatment outcomes.
9.Value of contrast-enhanced ultrasonography in microwave ablation treatment of symptomatic focal uterine adenomyosis
Xiao-Long LI ; Jia-Xin LI ; Song-Yuan YU ; Pei-Li FAN ; Yun-Jie JIN ; Er-Jiao XU ; Sai-Nan GUAN ; Er-Ya DENG ; Qiu-Yan LI ; Zheng-Biao JI ; Jiu-Ling QI ; Hui-Xiong XU ;
Ultrasonography 2024;43(1):68-77
Purpose:
This study evaluated the value of contrast-enhanced ultrasonography (CEUS) in the ultrasound-guided microwave ablation (MWA) treatment of symptomatic focal uterine adenomyosis.
Methods:
This retrospective study was conducted between March 2020 and January 2023, enrolling 52 patients with symptomatic focal uterine adenomyosis who had undergone MWA. All patients were examined with CEUS before and after MWA. The non-perfused volume (NPV) was compared between CEUS and dynamic contrast-enhanced magnetic resonance imaging (DCEMRI) following ablation. Therapeutic efficacy and safety were evaluated at 3-, 6-, and 12-month follow-ups. Additionally, this study explored the correlations between pre-treatment CEUS features and a volume reduction ratio indicating sufficient ablation, defined as 50% or more at the 3-month follow-up.
Results:
No significant differences in NPV were noted between CEUS and DCE-MRI immediately after MWA and during follow-up (all P>0.05). At the 3-month follow-up, the median VRRs for the uterus and adenomyosis were 33.2% and 63.9%, respectively. Sufficient ablation was achieved in 69.2% (36/52) of adenomyosis cases, while partial ablation was observed in the remaining 30.8% (16/52). The identification of non-enhancing areas on pre-treatment CEUS was associated with sufficient ablation (P=0.016). At the 12-month follow-up, significant decreases were observed in both the uterine and adenomyosis volumes (all P<0.001). Dysmenorrhea and menorrhagia were significantly alleviated at 12 months, and no major complications were encountered.
Conclusion
CEUS can be used to evaluate the ablation zone of focal adenomyosis that has been treated with MWA, similarly to DCE-MRI. The identification of non-enhancing areas on pretreatment CEUS indicates satisfactory treatment outcomes.
10.Expert consensus on ethical requirements for artificial intelligence (AI) processing medical data.
Cong LI ; Xiao-Yan ZHANG ; Yun-Hong WU ; Xiao-Lei YANG ; Hua-Rong YU ; Hong-Bo JIN ; Ying-Bo LI ; Zhao-Hui ZHU ; Rui LIU ; Na LIU ; Yi XIE ; Lin-Li LYU ; Xin-Hong ZHU ; Hong TANG ; Hong-Fang LI ; Hong-Li LI ; Xiang-Jun ZENG ; Zai-Xing CHEN ; Xiao-Fang FAN ; Yan WANG ; Zhi-Juan WU ; Zun-Qiu WU ; Ya-Qun GUAN ; Ming-Ming XUE ; Bin LUO ; Ai-Mei WANG ; Xin-Wang YANG ; Ying YING ; Xiu-Hong YANG ; Xin-Zhong HUANG ; Ming-Fei LANG ; Shi-Min CHEN ; Huan-Huan ZHANG ; Zhong ZHANG ; Wu HUANG ; Guo-Biao XU ; Jia-Qi LIU ; Tao SONG ; Jing XIAO ; Yun-Long XIA ; You-Fei GUAN ; Liang ZHU
Acta Physiologica Sinica 2024;76(6):937-942
As artificial intelligence technology rapidly advances, its deployment within the medical sector presents substantial ethical challenges. Consequently, it becomes crucial to create a standardized, transparent, and secure framework for processing medical data. This includes setting the ethical boundaries for medical artificial intelligence and safeguarding both patient rights and data integrity. This consensus governs every facet of medical data handling through artificial intelligence, encompassing data gathering, processing, storage, transmission, utilization, and sharing. Its purpose is to ensure the management of medical data adheres to ethical standards and legal requirements, while safeguarding patient privacy and data security. Concurrently, the principles of compliance with the law, patient privacy respect, patient interest protection, and safety and reliability are underscored. Key issues such as informed consent, data usage, intellectual property protection, conflict of interest, and benefit sharing are examined in depth. The enactment of this expert consensus is intended to foster the profound integration and sustainable advancement of artificial intelligence within the medical domain, while simultaneously ensuring that artificial intelligence adheres strictly to the relevant ethical norms and legal frameworks during the processing of medical data.
Artificial Intelligence/legislation & jurisprudence*
;
Humans
;
Consensus
;
Computer Security/standards*
;
Confidentiality/ethics*
;
Informed Consent/ethics*

Result Analysis
Print
Save
E-mail