1.Compact Fundus Imaging System Using Shack-Hartmann Wavefront Sensing for High-speed Auto-focus
Zhe-Kai LIN ; Long CHEN ; Geng-Yong ZHENG ; Jin-Tian HUANG ; Jia-Xin DONG ; Shang-Pan YANG ; Wen-Zheng DING ; Ding-An HAN ; Xue-Hua WANG ; Ya-Guang ZENG
Progress in Biochemistry and Biophysics 2026;53(4):1076-1086
ObjectiveThe widespread adoption of portable fundus cameras for primary care and community screening is hindered by limitations in current autofocus(AF) technologies. Image-based methods relying on sharpness evaluation require iterative searches, resulting in slow convergence, while projection-based techniques are susceptible to optical artifacts and calibration errors. To address these challenges, this study introduces a novel AF system based on direct wavefront sensing, designed to deliver simultaneous high speed, high precision, and operational robustness within the compact form factor essential for portable ophthalmic devices. MethodsOur approach fundamentally reimagines the AF process by directly measuring the ocular wavefront aberration. We developed a custom portable fundus camera integrating a miniaturized Shack-Hartmann wavefront sensor (SHWS) into the optical path. An 850 nm laser diode projects a point source onto the retina via oblique illumination to minimize corneal reflections. Light scattered from this spot carries the eye’s refractive error through the imaging optics and is directed to the SHWS, positioned at a plane optically conjugate to the primary color CMOS imaging sensor. A microlens array within the SHWS samples the incident wavefront, generating a pattern of focal spots on a CCD. Real-time centroid analysis of these spots provides a map of local wavefront slopes. These measurements are processed through a singular value decomposition (SVD) algorithm to fit a Zernike polynomial basis set, enabling real-time reconstruction of the wavefront phase. The defocus component (S) is extracted from the second-order Zernike coefficients, providing a direct, quantitative measure of the refractive error in diopters. This value serves as a precise error signal in a closed-loop control system, which commands a voice-coil actuated focusing lens to its null position in a single, deterministic step, eliminating the need for iterative search algorithms. ResultsComprehensive evaluation demonstrated the system’s high performance. Testing on a calibrated model eye (OEMI-7) established a highly linear relationship between the computed defocus S and the focusing lens position across a ±20 Diopter (D) compensation range, achievable within a 5 mm mechanical travel. The system achieved a focusing precision of 0.08 D, corresponding to an 18-fold improvement over a conventional projection spot-size method tested under identical conditions. The total focus acquisition time, encompassing wavefront measurement, computation, and lens actuation, averaged under 0.5 s. Clinical validation with 25 human volunteers (50 eyes, refractive range -15 D to +10 D) confirmed practical efficacy. The wavefront-sensing AF succeeded in 92% of attempts with a mean time of 0.5 s, substantially outperforming a projection-based benchmark which achieved only a 32% success rate with an average time of 4.25 s. The system provided instantaneous directional guidance and maintained stability during minor ocular movements. Objective assessment of image quality, via amplitude contrast of retinal vasculature, showed consistent and significant enhancement following AF correction across the entire tested diopter range. ConclusionThis work successfully implements and validates a direct wavefront-sensing autofocus paradigm for portable fundus cameras. By directly quantifying and compensating for the optical defocus aberration, this method bypasses the fundamental limitations of image-processing and projection-based techniques, enabling rapid, precise, and deterministic diopter compensation. The developed system delivers an exceptional combination of a wide operational range (±20 D), high accuracy (0.08 D), fast convergence (0.5 s), and a compact physical footprint. This technology provides a practical and high-performance focusing solution capable of enhancing the reliability, throughput, and diagnostic utility of portable retinal imaging in large-scale screening applications. Future efforts will be directed towards system cost optimization and performance adaptation for diverse ocular conditions.
2.Reactive and Enzyme-activated Probe Strategies for Imaging Acute Kidney Injury
Ru-Long CHEN ; Ting-Fei XIE ; Jin-Xin ZHANG ; Jia-Ting CHEN ; Jie LI ; Peng-Fei ZHANG ; Ji-Hong CHEN ; Lin-Tao CAI
Progress in Biochemistry and Biophysics 2026;53(6):1622-1637
Acute kidney injury (AKI) is a prevalent and life-threatening clinical syndrome characterised by a rapid decline in renal function and diverse pathological etiologies. The condition has been demonstrated to be associated with elevated mortality rates and an increased risk of progression to chronic kidney disease. At present, clinicians depend heavily on conventional functional markers, such as serum creatinine and urine output, for the diagnosis and staging of the disease. It is evident that these conventional indicators characteristically manifest a considerable temporal delay and only undergo modification subsequent to considerable tissue damage. This severely restricts the timeframe for early detection and timely therapeutic intervention. Furthermore, standard markers fail to provide specific biological information regarding the underlying cellular injury mechanisms. The utilisation of advanced probe technologies in molecular imaging offers a robust alternative to overcome these inherent diagnostic limitations.This comprehensive review systematically evaluates recent progress in the design and application of two primary categories of molecular imaging tools for acute kidney disease, specifically reactive probes and enzyme-activated probes. Reactive probes are engineered to specifically interact with redox-active chemical species, including hydrogen peroxide, peroxynitrite, hypochlorous acid, and sulfur dioxide. Because oxidative stress constitutes a primary early event in acute renal tubular damage, these probes enable researchers and clinicians to visualize early cellular injury and radical accumulation well before global renal functional decline becomes evident. We discuss the application of these reactive probes across multiple imaging modalities including fluorescence imaging, magnetic resonance imaging (MRI), positron emission tomography (PET), and photoacoustic techniques. Photoacoustic imaging combines high spatial resolution with deep tissue penetration and has successfully demonstrated the ability to provide diagnostic alerts up to 12 h before any detectable rise in serum creatinine levels. Additionally, specific reactive probes have shown promising translational potential when tested by high-throughput screening in clinical human urine samples. Enzyme-activated probes target the specific catalytic activity of disease-relevant enzymes. These include well-documented renal tubular structural biomarkers such as NAG, GGT, and ALP, along with apoptosis-related caspases and specific nitroreductases. By responding only to enzymatic cleavage, these tools provide highly specific and pathology-directed imaging readouts. Recent structural design strategies in this field have advanced significantly beyond single-enzyme detection. Researchers are now focusing on sophisticated dual-target recognition to minimize background noise, multimodal integration to cross-validate imaging signals, and theranostic applications where probes simultaneously deliver diagnostic feedback and therapeutic agents to injured tissues. Nanotechnology serves as a fundamental enabler for realizing these advanced probe functions. By precisely optimizing nanoparticle parameters such as hydrodynamic size, surface charge, and targeting ligands, researchers can achieve amplified signal output, highly precise kidney delivery, and protection against premature degradation in the systemic circulation. For example, modifying surface charges can significantly enhance the active uptake of nanoprobes by damaged renal tubular epithelial cells.While preclinical probe development has progressed rapidly, moving these technologies into routine clinical practice remains a major challenge. We analyze the translational feasibility and current obstacles from biological, technological, and regulatory perspectives. Although biological targets such as KIM-1, FAP, and ALP have been validated in extensive patient cohorts, practical barriers severely limit their immediate clinical application. These obstacles involve complex changes in in vivo pharmacokinetics. During an acute injury episode, the extreme drop in the glomerular filtration rate alters probe clearance and can cause unwanted systemic accumulation or confusing background imaging signals. Other major hurdles include a lack of comprehensive long-term toxicity data and the absence of standardized manufacturing protocols to ensure batch-to-batch consistency. Future successful translation will require rigorous multi-center clinical studies to confirm the true diagnostic value of these probes over traditional markers. Researchers must also establish strict standardization of imaging procedures and comprehensive safety evaluations. Ultimately, this review provides a thorough reference framework for designing clinically translatable molecular probes and building a precision diagnostic imaging system for acute kidney injury.
3.Construction of A Nomogram Prognostic Model Based on Pretreatment Inflammatory Indicator for Esophageal Squamous Cell Carcinoma Patients Treated with Radical Radiotherapy
Shenbo FU ; Long JIN ; Jing LIANG ; Junjun GUO ; Yu CHE ; Chenyang LI ; Yong CHEN
Cancer Research on Prevention and Treatment 2025;52(2):142-150
Objective To describe the significance of the pretreatment inflammatory indicators in predicting the prognosis of patients with esophageal squamous cell carcinoma (ESCC) after undergoing radical radiotherapy. Methods The data of 246 ESCC patients who underwent radical radiotherapy were retrospectively collected. Receiver operating characteristic (ROC) curves were drawn to determine the optimal cutoff values for platelet-lymphocyte ratio (PLR), neutrophil-lymphocyte ratio (NLR), and systemic immune-inflammation index (SII). The Kaplan-Meier method was used for survival analysis. We conducted univariate and multivariate analyses by using the Cox proportional risk regression model. Software R (version 4.2.0) was used to create the nomogram of prognostic factors. Results The results of the ROC curve analysis showed that the optimal cutoff values of PLR, NLR, and SII were 146.06, 2.67, and 493.97, respectively. The overall response rates were 77.6% and 64.5% in the low and high NLR groups, respectively (P<0.05). The results of the Kaplan-Meier survival analysis revealed that the prognosis of patients in the low PLR, NLR, and SII group was better than that of patients in the high PLR, NLR, and SII group (all P<0.05). The results of the multivariate Cox regression analysis showed that gender, treatment modalities, T stage, and NLR were independent factors affecting the overall survival (OS). In addition, T stage and NLR were independent factors affecting the progression-free survival (PFS) (all P<0.05). The nomogram models of OS and PFS prediction were established based on multivariate analysis. The C-index values were 0.703 and 0.668. The calibration curves showed excellent consistency between the predicted and observed OS and PFS. Conclusion The pretreatment values of PLR, NLR, and SII are correlated with the prognosis of patients with ESCC who underwent radical radiotherapy. Moreover, NLR is an independent factor affecting the OS and PFS of ESCC patients. The NLR-based nomogram model has a good predictive ability.
4.Association between alcohol consumption and lumbar disc herniation
ZHANG Ronghua ; HU Jihong ; ZHAO Jirong ; JIN Limei ; CHEN Zhiwei ; SHAO Hong ; WANG Li ; ZHANG Zhidong ; LONG Kaichong
Journal of Preventive Medicine 2025;37(11):1129-1134
Objective:
To analyze the association between alcohol consumption and lumbar disc herniation (LDH), so as to provide a reference for the development of prevention and treatment strategies for LDH.
Methods:
From May to July 2022, permanent residents aged ≥18 years from eight counties (cities/districts) in Gansu Province were selected using a multistage stratified random sampling method. Data on basic characteristics, alcohol consumption in the past 30 days, hypertension, and diabetes mellitus were collected through questionnaire surveys. LDH was determined based on imaging findings, combined with disease history or clinical symptoms. Multivariable logistic regression model was used to analyze the association between alcohol consumption and LDH, with subgroup analyses conducted by gender, age, ethnicity, and altitude of residence. Propensity score matching (PSM) was utilized for sensitivity analysis.
Results:
A total of 4 545 individuals were surveyed. There were 2 026 (44.58%) males and 2 519 (55.42%) females. The mean age was (44.82±15.33) years. The study participants were predominantly of Han ethnicity, with 2 598 persons accounting for 57.17%. The altitude of residence was mainly above 3 500 m, with 1 941 persons accounting for 42.71%. There were 574 alcohol drinkers, accounting for 12.63%. LDH was detected in 1 035 cases, with a detection rate of 22.77%. Multivariable logistic regression analysis showed that after adjusting for gender, age, physical activity, and hypertension, compared to non-drinking residents, alcohol-consuming residents exhibited a 27.6% reduction in the risk of LDH (OR=0.724, 95%CI: 0.544-0.963). No significant interaction effects on LDH risk were observed between alcohol consumption and gender, age, ethnicity, or altitude of residence (all Pfor interaction >0.05). The results of the sensitivity analysis indicated that compared to non-drinking residents, alcohol-consuming residents exhibited a 38.8% reduction in the risk of LDH (OR=0.612, 95%CI: 0.382-0.976).
Conclusion
Alcohol consumption was statistically associated with a lower risk of LDH.
5.Transparency of clinical practice guidelines: A mixed methods research.
Xinyi WANG ; Youlin LONG ; Tengyue HU ; Zixin YANG ; Liqin LIU ; Liu YANG ; Yifan CHENG ; Ran GU ; Yanjiao SHEN ; Nan YANG ; Jin HUANG ; Yaolong CHEN ; Liang DU
Chinese Medical Journal 2025;138(15):1882-1884
6.Ferrum@albumin assembled nanoclusters inhibit NF-κB signaling pathway for NIR enhanced acute lung injury immunotherapy.
Xiaoxuan GUAN ; Binbin ZOU ; Weiqian JIN ; Yan LIU ; Yongfeng LAN ; Jing QIAN ; Juan LUO ; Yanjun LEI ; Xuzhi LIANG ; Shiyu ZHANG ; Yuting XIAO ; Yan LONG ; Chen QIAN ; Chaoyu HUANG ; Weili TIAN ; Jiahao HUANG ; Yongrong LAI ; Ming GAO ; Lin LIAO
Acta Pharmaceutica Sinica B 2025;15(11):5891-5907
Acute lung injury (ALI) has been a kind of acute and severe disease that is mainly characterized by systemic uncontrolled inflammatory response to the production of huge amounts of reactive oxygen species (ROS) in the lung tissue. Given the critical role of ROS in ALI, a Fe3O4 loaded bovine serum albumin (BSA) nanocluster (BF) was developed to act as a nanomedicine for the treatment of ALI. Combining with NIR irradiation, it exhibited excellent ROS scavenging capacity. Significantly, it also displayed the excellent antioxidant and anti-inflammatory functions for lipopolysaccharides (LPS) induced macrophages (RAW264.7), and Sprague Dawley rats via lowering intracellular ROS levels, reducing inflammatory factors expression levels, inducing macrophage M2 polarization, inhibiting NF-κB signaling pathway, increasing CD4+/CD8+ T cell ratios, as well as upregulating HSP70 and CD31 expression levels to reprogram redox homeostasis, reduce systemic inflammation, activate immunoregulation, and accelerate lung tissue repair, finally achieving the synergistic enhancement of ALI immunotherapy. It finally provides an effective therapeutic strategy of BF + NIR for the management of inflammation related diseases.
7.Correction to: A Virtual Reality Platform for Context-Dependent Cognitive Research in Rodents.
Xue-Tong QU ; Jin-Ni WU ; Yunqing WEN ; Long CHEN ; Shi-Lei LV ; Li LIU ; Li-Jie ZHAN ; Tian-Yi LIU ; Hua HE ; Yu LIU ; Chun XU
Neuroscience Bulletin 2025;41(5):932-932
8.Research on the design and application value of a simulation system for surgical operation based on virtual reality technique and intelligent scoring function
Long LI ; Qingbo WANG ; Yubo LIANG ; Jin LI ; Wanling LUO ; Xingming CHEN ; Yang DUAN ; Zhiyi TANG ; Shengjie NIE ; Yang KE
China Medical Equipment 2025;22(5):28-32
Objective:To design a set of simulation system for surgical operation based on virtual reality(VR)technique and intelligent scoring functions,so as to assess its clinical application effect.Methods:The Digital Imaging and Communications in Medicine(DICOM)images of typical patients were collected.Materialise Interactive Medical Image Control System(MIMICS)software was adopted to reconstruct the three-dimensional(3D)model of diseased organs.Surgical instrument models were constructed by using 3D Max software.Unity 3D software was adopted to construct simulation system for surgical operation with VR+intelligent scoring.A total of 40 surgical resident physicians,who were employed with 3 years since 2019 in The Second Affiliated Hospital of Kunming Medical University,were selected.They were divided into observation group and control group,with 20 cases in each group.The observation group used simulation system for surgical operation to conduct intelligent scoring for cholecystectomy under laparoscope,and the control group used conventional scoring for surgical operation.The scores of surgical operation and test between the two groups were compared.Results:The mean value of surgical operation time of the observation group was(1.72±0.41)h,and the average incidence of complication was(0.03±0.02)%,both of them of the observation group were significantly lower than those of the control group[(2.25±0.42)h and(0.05±0.03)%].The differences of them between two groups were statistically significant(t=9.00,4.08,P<0.05).The test scores of surgical operation of the observation group was also significantly higher than that of the control group(t=5.26,P<0.001).Conclusion:The developed simulation system for surgical operation with VR+intelligent scoring can significantly enhance users'surgical operation skills and improve learning outcomes,which has favorable prospects in future applications.
9.Bioequivalence of rivaroxabanpian in healthy Chinese subjects
Xu ZHU ; Xiao-ni WANG ; Chang LU ; Ran ZHANG ; Ning CHEN ; Jin-mei ZHOU ; Feng ZHANG ; Wen ZHANG ; Sheng-long ZHAO ; Shun-wang HUANG ; Huan ZHOU
Chinese Pharmacological Bulletin 2025;41(11):2194-2199
Aim To evaluate the bioequivalence of two oral preparations of rivaroxaban tablets(test preparation T and refe-rence preparation R)in fasting/postprandibular state in healthy Chinese subjects.Methods A randomized,open,single-dose,four-cycle,completely repeated crossover experiment was used in this study.A total of 70 healthy male and female subjects were enrolled,including 38 subjects in the fasting group and 32 sub-jects in the postprandial group.Rivaroxaban tablets(2.5 mg/tablet)were taken orally once per cycle and their reference preparations were tested.The plasma rivaroxaban concentration was determined by LC-MS/MS method.The pharmacokinetic parameters of rivaroxaban tablets were calculated by WinNonlin software,and the parameters were analyzed and processed.Re-sults The PK parameters of rivaroxaban tablets and reference preparations in fasting group were as follows:Cmax was(72.48±17.08)and(66.36±15.64)μg·L-1,respectively.AUC0-t were(383.49±101.06)and(370.43±102.16)h·ng·mL-1,and AUC0-inr were(389.58±102.28)and(375.84±103.01)h·μg·L-,respectively.Main PK parameters of subjects taking rivaroxaban tablets orally after meals:Cmax were(66.48±15.64 and 60.87±13.44)μg·L-1,AUC0-t were(404.44±72.58)and(381.80±79.93)h·μg·L-1,re-spectively.AUC0_inf was(410.88±73.55)and(393.64±69.71)h·μg·L-1,respectively.Under fasting and postmeal conditions,subjects took rivaroxaban test and reference prepara-tion orally,one tablet(2.5 mg/tablet)each time.The geometric mean of the main pharmacokinetic parameters of rivaroxaban in plasma(Cmax,AUC0-t,AUC0-inf)and their corresponding values had a 90%confidence interval ranging from 80.00%to 125.00%.No serious adverse events or unexpected adverse e-vents occurred in both groups.Conclusion Rivaroxaban tablets are bioequivalent and safe in vivo under fasting and postprandial conditions.
10.Preliminary study on the clinical efficacy of drug treatment combined with transcranial alternating current stimulation in the treatment of patients with bipolar I disorder
Huiling WU ; Long WANG ; Shengchun JIN ; Li WAN ; Yaqun CHEN ; Qinhui ZHANG
Chinese Journal of Primary Medicine and Pharmacy 2025;32(7):1060-1064
Objective:To investigate the clinical efficacy of transcranial alternating current stimulation (tACS) combined with drug treatment in patients with bipolar Ⅰ disorder (BD Ⅰ).Methods:Forty-two patients with BD Ⅰ who were admitted to the Mental Health Center Affiliated to Anhui Medical University from March 2022 to June 2023 were included in this randomized double-blind study. These patients were randomly divided into a control group and an observation group using an Excel spreadsheet. In the control group, patients received 10 sessions of sham stimulation in addition to drug treatment, while the observation group received 10 sessions of tACS along with drug treatment. All patients were treated for 2 weeks. Each patient received stimulation for 15 minutes on each of the right and left prefrontal lobes once every working day. The Montreal Cognitive Assessment (MoCA) scores and Bech-Rafaelsen Mania Scale (BRMS) scores were compared between the two groups before and after treatment. Eighteen patients from the observation group and nineteen patients from the control group were included in the final analysis.Results:Two weeks after treatment, the MoCA score in the observation group was higher than that in the control group [(27.39 ± 1.88) vs. (24.63 ± 2.39)], and the BRMS score in the observation group was lower than that in the control group [(15.89 ± 3.18) vs. (19.00 ± 3.32)]. These differences were statistically significant ( t = -3.89, 2.91, both P < 0.05). After treatment, the MoCA score in the observation group increased, while the BRMS score decreased ( t = 5.04, -4.14, both P < 0.05). Pearson correlation analysis indicated the change in MoCA score was negatively correlated with BRMS score in both groups ( r = -0.433, P < 0.05). Conclusions:Drug treatment combined with tACS greatly improved clinical cognitive symptoms and reduced manic symptoms in patients with BD Ⅰ. The combined therapy exhibited better efficacy than monotherapy.


Result Analysis
Print
Save
E-mail