1.Molecular mechanisms of hyperlipidemic acute pancreatitis comorbid with fatty liver disease
Shuo DONG ; Ying WANG ; Xiwang WANG ; Jingjing JIN ; Kai WEI ; Xiao WANG
Journal of Clinical Hepatology 2026;42(3):739-744
Both hyperlipidemic acute pancreatitis and fatty liver disease are associated with lipid metabolism disorders and are commonly comorbid with each other in clinical practice. The pathogenesis of such comorbidity involves the interaction between multiple factors such as hypertriglyceridemia, metabolic syndrome, obesity, and insulin resistance, and these factors may form a vicious cycle and jointly promote disease progression. In clinical practice, hyperlipidemic acute pancreatitis is characterized by severe disease conditions, a high incidence rate of complications, a high mortality rate, and a tendency for recurrence, and it can easily lead to multi-organ damage and even multiple organ failure without timely treatment, posing a serious threat to the life of patients. Starting from the various signaling pathways associated with hyperlipidemic acute pancreatitis comorbid with fatty liver disease, this article discusses the potential molecular mechanisms of synergistic pathogenesis between hyperlipidemic acute pancreatitis and fatty liver disease, so as to provide a reference for the early prevention and treatment of such comorbidity.
2.Compact Fundus Imaging System Using Shack-Hartmann Wavefront Sensing for High-speed Auto-focus
Zhe-Kai LIN ; Long CHEN ; Geng-Yong ZHENG ; Jin-Tian HUANG ; Jia-Xin DONG ; Shang-Pan YANG ; Wen-Zheng DING ; Ding-An HAN ; Xue-Hua WANG ; Ya-Guang ZENG
Progress in Biochemistry and Biophysics 2026;53(4):1076-1086
ObjectiveThe widespread adoption of portable fundus cameras for primary care and community screening is hindered by limitations in current autofocus(AF) technologies. Image-based methods relying on sharpness evaluation require iterative searches, resulting in slow convergence, while projection-based techniques are susceptible to optical artifacts and calibration errors. To address these challenges, this study introduces a novel AF system based on direct wavefront sensing, designed to deliver simultaneous high speed, high precision, and operational robustness within the compact form factor essential for portable ophthalmic devices. MethodsOur approach fundamentally reimagines the AF process by directly measuring the ocular wavefront aberration. We developed a custom portable fundus camera integrating a miniaturized Shack-Hartmann wavefront sensor (SHWS) into the optical path. An 850 nm laser diode projects a point source onto the retina via oblique illumination to minimize corneal reflections. Light scattered from this spot carries the eye’s refractive error through the imaging optics and is directed to the SHWS, positioned at a plane optically conjugate to the primary color CMOS imaging sensor. A microlens array within the SHWS samples the incident wavefront, generating a pattern of focal spots on a CCD. Real-time centroid analysis of these spots provides a map of local wavefront slopes. These measurements are processed through a singular value decomposition (SVD) algorithm to fit a Zernike polynomial basis set, enabling real-time reconstruction of the wavefront phase. The defocus component (S) is extracted from the second-order Zernike coefficients, providing a direct, quantitative measure of the refractive error in diopters. This value serves as a precise error signal in a closed-loop control system, which commands a voice-coil actuated focusing lens to its null position in a single, deterministic step, eliminating the need for iterative search algorithms. ResultsComprehensive evaluation demonstrated the system’s high performance. Testing on a calibrated model eye (OEMI-7) established a highly linear relationship between the computed defocus S and the focusing lens position across a ±20 Diopter (D) compensation range, achievable within a 5 mm mechanical travel. The system achieved a focusing precision of 0.08 D, corresponding to an 18-fold improvement over a conventional projection spot-size method tested under identical conditions. The total focus acquisition time, encompassing wavefront measurement, computation, and lens actuation, averaged under 0.5 s. Clinical validation with 25 human volunteers (50 eyes, refractive range -15 D to +10 D) confirmed practical efficacy. The wavefront-sensing AF succeeded in 92% of attempts with a mean time of 0.5 s, substantially outperforming a projection-based benchmark which achieved only a 32% success rate with an average time of 4.25 s. The system provided instantaneous directional guidance and maintained stability during minor ocular movements. Objective assessment of image quality, via amplitude contrast of retinal vasculature, showed consistent and significant enhancement following AF correction across the entire tested diopter range. ConclusionThis work successfully implements and validates a direct wavefront-sensing autofocus paradigm for portable fundus cameras. By directly quantifying and compensating for the optical defocus aberration, this method bypasses the fundamental limitations of image-processing and projection-based techniques, enabling rapid, precise, and deterministic diopter compensation. The developed system delivers an exceptional combination of a wide operational range (±20 D), high accuracy (0.08 D), fast convergence (0.5 s), and a compact physical footprint. This technology provides a practical and high-performance focusing solution capable of enhancing the reliability, throughput, and diagnostic utility of portable retinal imaging in large-scale screening applications. Future efforts will be directed towards system cost optimization and performance adaptation for diverse ocular conditions.
3.The Role and Mechanism of Circadian Rhythm Regulation in Skin Tissue Regeneration
Ya-Qi ZHAO ; Lin-Lin ZHANG ; Xiao-Meng MA ; Zhen-Kai JIN ; Kun LI ; Min WANG
Progress in Biochemistry and Biophysics 2025;52(5):1165-1178
Circadian rhythm is an endogenous biological clock mechanism that enables organisms to adapt to the earth’s alternation of day and night. It plays a fundamental role in regulating physiological functions and behavioral patterns, such as sleep, feeding, hormone levels and body temperature. By aligning these processes with environmental changes, circadian rhythm plays a pivotal role in maintaining homeostasis and promoting optimal health. However, modern lifestyles, characterized by irregular work schedules and pervasive exposure to artificial light, have disrupted these rhythms for many individuals. Such disruptions have been linked to a variety of health problems, including sleep disorders, metabolic syndromes, cardiovascular diseases, and immune dysfunction, underscoring the critical role of circadian rhythm in human health. Among the numerous systems influenced by circadian rhythm, the skin—a multifunctional organ and the largest by surface area—is particularly noteworthy. As the body’s first line of defense against environmental insults such as UV radiation, pollutants, and pathogens, the skin is highly affected by changes in circadian rhythm. Circadian rhythm regulates multiple skin-related processes, including cyclic changes in cell proliferation, differentiation, and apoptosis, as well as DNA repair mechanisms and antioxidant defenses. For instance, studies have shown that keratinocyte proliferation peaks during the night, coinciding with reduced environmental stress, while DNA repair mechanisms are most active during the day to counteract UV-induced damage. This temporal coordination highlights the critical role of circadian rhythms in preserving skin integrity and function. Beyond maintaining homeostasis, circadian rhythm is also pivotal in the skin’s repair and regeneration processes following injury. Skin regeneration is a complex, multi-stage process involving hemostasis, inflammation, proliferation, and remodeling, all of which are influenced by circadian regulation. Key cellular activities, such as fibroblast migration, keratinocyte activation, and extracellular matrix remodeling, are modulated by the circadian clock, ensuring that repair processes occur with optimal efficiency. Additionally, circadian rhythm regulates the secretion of cytokines and growth factors, which are critical for coordinating cellular communication and orchestrating tissue regeneration. Disruptions to these rhythms can impair the repair process, leading to delayed wound healing, increased scarring, or chronic inflammatory conditions. The aim of this review is to synthesize recent information on the interactions between circadian rhythms and skin physiology, with a particular focus on skin tissue repair and regeneration. Molecular mechanisms of circadian regulation in skin cells, including the role of core clock genes such as Clock, Bmal1, Per and Cry. These genes control the expression of downstream effectors involved in cell cycle regulation, DNA repair, oxidative stress response and inflammatory pathways. By understanding how these mechanisms operate in healthy and diseased states, we can discover new insights into the temporal dynamics of skin regeneration. In addition, by exploring the therapeutic potential of circadian biology in enhancing skin repair and regeneration, strategies such as topical medications that can be applied in a time-limited manner, phototherapy that is synchronized with circadian rhythms, and pharmacological modulation of clock genes are expected to optimize clinical outcomes. Interventions based on the skin’s natural rhythms can provide a personalized and efficient approach to promote skin regeneration and recovery. This review not only introduces the important role of circadian rhythms in skin biology, but also provides a new idea for future innovative therapies and regenerative medicine based on circadian rhythms.
4.Analysis of clinical characteristics and influencing factors of patients with postmenopausal osteoporosis combined with dyslipidemia.
Rong XIE ; Li-Guo ZHU ; Zi-Kai JIN ; Tian-Xiao FENG ; Ke ZHAO ; Da WANG ; Ling-Hui LI ; Xu WEI
China Journal of Orthopaedics and Traumatology 2025;38(5):487-493
OBJECTIVE:
To explore the co-morbid influencing factors of postmenopausal osteoporosis(PMOP) and dyslipidemia, and to provide evidence-based basis for clinical co-morbidity management.
METHODS:
Based on the 2017 to 2018 Beijing community cross-sectional survey data, PMOP patients were included and divided into the dyslipidemia group and the uncomplicated dyslipidemia group according to whether they were comorbid with dyslipidemia. Demographic characteristics, living habits and disease history were collected through questionnaires, and bone mineral density and bone metabolism biomarkers (osteocalcin, blood calcium, serum typeⅠprocollagen N-terminal prepeptide, etc.) were detected on site. Co-morbidity risk factors were analyzed using binary logistic regression.
RESULTS:
Three hundred and twenty patients with PMOP were included, including the comorbid group (75 patients) and the uncomplicated group (245 patients). The results showed that history of cardiovascular disease [OR=1.801, 95%CI(1.003, 3.236), P=0.049], history of cerebrovascular disease [OR=2.923, 95%CI(1.460, 5.854), P=0.002], frying and cooking methods[OR=5.388, 95%CI(1.632, 17.793), P=0.006], OST results[OR=0.910, 95%CI(0.843, 0.983), P=0.016], and blood Ca results [OR=60.249, 95%CI(1.862, 1 949.926), P=0.021] were the influencing factors of PMOP complicated with dyslipidemia.
CONCLUSION
Focus should be placed on the influencing factors of PMOP and dyslipidemia co-morbidities, with emphasis on multidimensional assessment, combining lifestyle interventions with bone metabolism marker monitoring to optimize co-morbidity management.
Humans
;
Dyslipidemias/epidemiology*
;
Female
;
Middle Aged
;
Osteoporosis, Postmenopausal/metabolism*
;
Aged
;
Cross-Sectional Studies
;
Risk Factors
;
Bone Density
5.Clinical analysis of clavicle anatomical plate in the treatment of AllmanⅡC type of clavicle fracture.
Jian-Zhong GE ; Jin-Rui GU ; Peng XU ; Zhi-Ling ZHANG ; Kai WANG
China Journal of Orthopaedics and Traumatology 2025;38(7):711-715
OBJECTIVE:
To evaluate the clinical efficacy and safety of clavicular anatomical plate in the treatment of clavicular Allmanic fracture.
METHODS:
Between January 2016 and December 2022, 27 patients with Allman ⅡC distal clavicle fractures were treated with clavicular anatomical plate. There were 19 males and 8 females, aged from 16 to 69 years old, with an average of (39.74±12.71) years old. There were 15 patients on the left side and 12 patients on the right side. There were 15 patients with single clavicle fracture and 12 patients complicated with other parts of the body or organ injury. The broken ends of the fractures were fixed with clavicular anatomical plate, including common compression clavicular anatomical plate in 19 patients and locking clavicular anatomical plate in 8 patients. The operation time and hospitalization days were recorded. Visual analogue scales (VAS) were utilized to assess subjective pain levels both preoperatively and 3 days postoperatively. Postoperatively, patients were monitored at intervals of 1 to 3 months until X-ray films confirmed fracture healing. In accordance with the University of California, Los Angeles (UCLA) shoulder rating system, evaluations were conducted on postoperative pain alleviation, functional recovery, range of motion in forward flexion, strength in forward flexion, and patient satisfaction.
RESULTS:
All patients were followed up for a period ranging from 12 to 18 months with an average of (14.70±1.61) months, and all clavicular fractures achieved successful union. The wounds of 24 patients healed in one stage, and 3 patients developed bleeding and exudation, they were cured after dressing change. There were no complications such as infection, plate and screw fracture, vascular and nerve injury. The operation time was(67.56±11.01) min. Significant differences were observed in pain relief, functional improvement, range of motion for forward flexion, strength of forward flexion, patient satisfaction, and overall scores at preoperative, 3 months postoperatively, 6 months postoperatively, and at the final follow-up(P<0.001).
CONCLUSION
The utilization of clavicular anatomical plates for the management of Allman typeⅡC fractures can provide early and stable fixation without compromising the acromioclavicular joint, thereby enabling patients to commence early mobilization and ensuring optimal fracture healing.
Humans
;
Male
;
Female
;
Clavicle/surgery*
;
Adult
;
Bone Plates
;
Middle Aged
;
Fractures, Bone/physiopathology*
;
Adolescent
;
Aged
;
Fracture Fixation, Internal/instrumentation*
;
Young Adult
6.Application of 3D-printed auxiliary guides in adolescent scoliosis surgery.
Dong HOU ; Jian-Tao WEN ; Chen ZHANG ; Jin HUANG ; Chang-Quan DAI ; Kai LI ; Han LENG ; Jing ZHANG ; Shao-Bo YANG ; Xiao-Juan CUI ; Juan WANG ; Xiao-Yun YUAN
China Journal of Orthopaedics and Traumatology 2025;38(11):1119-1125
OBJECTIVE:
To investigate the accuracy and safety of pedicle screw placement using 3D-printed auxiliary guides in scoliosis correction surgery for adolescents.
METHODS:
A retrospective analysis was conducted on the clinical data of 51 patients who underwent posterior scoliosis correction surgery from January 2020 to March 2023. Among them, there were 35 cases of adolescent idiopathic scoliosis and 16 cases of congenital scoliosis. The patients were divided into two groups based on the auxiliary tool used:the 3D-printed auxiliary guide screw placement group (3D printing group) and the free-hand screw placement group (free-hand group, without auxiliary tools). The 3D printing group included 32 patients (12 males and 20 females) with an average age of (12.59±2.60) years;the free-hand group included 19 patients (7 males and 12 females) with an average age of (14.58±3.53) years. The two groups were compared in terms of screw placement accuracy and safety, spinal correction rate, intraoperative blood loss, number of intraoperative fluoroscopies, operation time, hospital stay, and preoperative and last follow-up scores of the Scoliosis Research Society-22 (SRS-22) questionnaire.
RESULTS:
A total of 707 pedicle screws were placed in the two groups, with 441 screws in the 3D printing group and 266 screws in the free-hand group. All patients in both groups successfully completed the surgery. There was a statistically significant difference in operation time between the two groups (P<0.05). The screw placement accuracy rate of the 3D printing group was 95.46% (421/441), among which the Grade A placement rate was 89.34% (394/441);the screw placement accuracy rate of the free-hand group was 86.47% (230/266), with a Grade A placement rate of 73.31% (195/266). There were statistically significant differences in the accuracy of Grade A, B, and C screw placements between the two groups (P<0.05), while no statistically significant differences were observed in intraoperative blood loss, number of fluoroscopies, correction rate, or hospital stay (P>0.05). In the SRS-22 questionnaire scores, the scores of functional status and activity ability, self-image, mental status, and pain of patients in each group at the last follow-up were significantly improved compared with those before surgery (P<0.05), but there were no statistically significant differences in all scores between the two groups (P>0.05).
CONCLUSION
In scoliosis correction surgery, compared with traditional free-hand screw placement, the use of 3D-printed auxiliary guides for screw placement significantly improves the accuracy and safety of screw placement and shortens the operation time.
Humans
;
Male
;
Scoliosis/surgery*
;
Female
;
Adolescent
;
Printing, Three-Dimensional
;
Retrospective Studies
;
Pedicle Screws
;
Child
7.Predictive value of bpMRI for pelvic lymph node metastasis in prostate cancer patients with PSA≤20 μg/L.
Lai DONG ; Rong-Jie SHI ; Jin-Wei SHANG ; Zhi-Yi SHEN ; Kai-Yu ZHANG ; Cheng-Long ZHANG ; Bin YANG ; Tian-Bao HUANG ; Ya-Min WANG ; Rui-Zhe ZHAO ; Wei XIA ; Shang-Qian WANG ; Gong CHENG ; Li-Xin HUA
National Journal of Andrology 2025;31(5):426-431
Objective: The aim of this study is to explore the predictive value of biparametric magnetic resonance imaging(bpMRI)for pelvic lymph node metastasis in prostate cancer patients with PSA≤20 μg/L and establish a nomogram. Methods: The imaging data and clinical data of 363 patients undergoing radical prostatectomy and pelvic lymph node dissection in the First Affiliated Hospital of Nanjing Medical University from July 2018 to December 2023 were retrospectively analyzed. Univariate analysis and multivariate logistic regression were used to screen independent risk factors for pelvic lymph node metastasis in prostate cancer, and a nomogram of the clinical prediction model was established. Calibration curves were drawn to evaluate the accuracy of the model. Results: Multivariate logistic regression analysis showed extrocapusular extension (OR=8.08,95%CI=2.62-24.97, P<0.01), enlargement of pelvic lymph nodes (OR=4.45,95%CI=1.16-17.11,P=0.030), and biopsy ISUP grade(OR=1.97,95%CI=1.12-3.46, P=0.018)were independent risk factors for pelvic lymph node metastasis. The C-index of the prediction model was 0.834, which indicated that the model had a good prediction ability. The actual value of the model calibration curve and the prediction probability of the model fitted well, indicating that the model had a good accuracy. Further analysis of DCA curve showed that the model had good clinical application value when the risk threshold ranged from 0.05 to 0.70.Conclusion: For prostate cancer patients with PSA≤20 μg/L, bpMRI has a good predictive value for the pelvic lymph node metastasis of prostate cancer with extrocapusular extension, enlargement of pelvic lymph nodes and ISUP grade≥4.
Humans
;
Male
;
Prostatic Neoplasms/diagnostic imaging*
;
Lymphatic Metastasis
;
Retrospective Studies
;
Nomograms
;
Prostate-Specific Antigen/blood*
;
Lymph Nodes/pathology*
;
Pelvis
;
Predictive Value of Tests
;
Prostatectomy
;
Lymph Node Excision
;
Risk Factors
;
Magnetic Resonance Imaging
;
Logistic Models
;
Middle Aged
;
Aged
8.Implant restoration assisted by autonomous dental robot after upper jaw reconstruction
Zhenxing GUO ; Yue WANG ; Minmin ZHENG ; Jin TU ; Jianhua WEI ; Shizhu BAI ; Yimin ZHAO ; Kai JIAO
Journal of Practical Stomatology 2025;41(2):173-176
The left maxilla of a patient was resected because of tumor,and the defect was reconstruted with fibular transplantation.The autonomous dental implant robot technology was used to achieve precise implantation of multiple implants and immediate denture restoration within the limited left maxilla.The surgery was minimally invasive and efficient,and significantly reducing patient post-operative discomfort.The final restoration was completed 6 months after surgery.
9.Effect of minimally invasive interbody fusion device height on lumbar biomechanics in patients with adolescent lumbar disc herniation
Ruofan ZHANG ; Huanhuan GUAN ; Zhuoqun HE ; Yunfeng ZHANG ; Feng JIN ; Zhiqiang WANG ; Jianzhong WANG ; Xiaohe LI ; Yong ZHU ; Haiyan WANG ; Kai ZHANG
Chinese Journal of Tissue Engineering Research 2025;29(21):4421-4429
BACKGROUND:Adolescent lumbar disc herniation is the main cause of low back pain in adolescents. At present,most of them are treated by conservativetreatment. When long-term non-surgical treatment attempts,surgery may be necessary to prevent further injury when the patient's symptoms are notsufficiently relieved or when the patient has symptoms of single nerve paralysis or compression of the cauda equina,it is very important to choose a suitable interbody fusion device for the surgical treatment of the patients.OBJECTIVE:To explore the effects of minimally invasive interbody fusion with different heights on lumbar biomechanics in patients with adolescent lumbar disc herniation.METHODS:CT scans of a 17-year-old male patient with adolescent lumbar disc herniation (L4-5 segment herniation) were collected. After the three-dimensional reconstruction of MIMICS,the interbody fusion device equal to and 3 mm higher than the intervertebral space was selected for analysis,so two expandablemixed material interbody fusion devices were designed and reconstructed. Fusion device L:11 mm high front,9 mm high posterior,9 mm wide,28 mmlong,and fusion device H:14 mm high front,11 mm high posterior,11 mm wide,28 mm long and the lumbar fusion device was modeled. The fusion deviceand lumbar spine model were optimized,inversely modeled,and then imported into ABAQUS,and finally the 3D model of lumbar fusion was obtained.The physiological activities of the human body were simulated,such as lumbar extension,forward bending,right bending,and left bending,to obtain thecorresponding stress contours. The biomechanical characteristics of the L4-5 vertebra under seven different working conditions were observed.RESULTS AND CONCLUSION:(1) The maximum stress of the two kinds of fuses was in the condition of forward bending and backward extension,the stress value of H fuses was (18.27±3.80) Mpa and (15.02±3.24) Mpa;the stress value of L fuses was (9.16±0.05) Mpa and (9.17±1.83) Mpa. The stress values of the end plate of the H-fusion in the extension station were (19.11±4.03) Mpa and (16.32±3.72) Mpa respectively. The stress values of the L-fusion end plate were (9.13±0.01) Mpa and (4.92±1.01) Mpa respectively. (2) The stress of H-type fusing end plate was higher than that of L-type fusing end plate except for L-5 end plate at neutral position (P<0.05). (3) Choosing an interbody fusion device with a height of more than 3 mm in the same intervertebral space has a more stable biomechanics.
10.Expert consensus on surgical treatment and rehabilitation for competitive sports athletes returning to sports after anterior cruciate ligament injury (version 2025)
Kai HUANG ; Lunhao BAI ; Qing BI ; Hong CHEN ; Jiwu CHEN ; Xuesong DAI ; Wenyong FEI ; Weili FU ; Zhizeng GAO ; Lin GUO ; Yinghui HUA ; Jingmin HUANG ; Suizhu HUANG ; Xuan HUANG ; Jian LI ; Qiang LI ; Shuzhen LI ; Yanlin LI ; Yunxia LI ; Zhong LI ; Ning LIU ; Yuqiang LIU ; Wei LU ; Hongbin LYU ; Haile PAN ; Xiaoyun PAN ; Chao QI ; Weiliang SHEN ; Luning SUN ; Jin TANG ; Zimin WANG ; Bide WANG ; Ru WANG ; Shaobai WANG ; Licheng WEI ; Weidong XU ; Yongsheng XU ; Jizhou YANG ; Liang YANG ; Rui YANG ; Hongbo YOU ; Tengbo YU ; Jiakuo YU ; Bing YUE ; Hua ZHANG ; Hui ZHANG ; Qingsong ZHANG ; Xintao ZHANG ; Jiajun ZHAO ; Lilian ZHAO ; Qichun ZHAO ; Song ZHAO ; Jiapeng ZHENG ; Jiang ZHENG ; Zhi ZHENG ; Jingbin ZHOU ; Jinzhong ZHAO
Chinese Journal of Trauma 2025;41(4):325-338
With the rapid development of competitive sports, the incidence of anterior cruciate ligament (ACL) injury is on the rise. Such injuries may shorten athletes′ career and lead to other long-term adverse consequences. Although athletes generally recover well after ACL reconstruction, many still struggle to return to their pre-injury performance levels. Advances in the understanding of ACL anatomy and injury mechanisms, along with the evolution of surgical techniques and rehabilitation methods, have provided more individualized and tailored options for athletes following ACL injuries. However, there is currently no consensus in China regarding surgical and rehabilitation strategies for competitive athletes aiming to return to sports after ACL injuries. To this end, the Sports Medicine Committee of the Chinese Research Hospital Association and the Editorial Board of the Chinese Journal of Trauma jointly formulated the Expert consensus on surgical treatment and rehabilitation for competitive sports athletes returning to sports after anterior cruciate ligament injury ( version 2025), and presented 14 recommendations covering surgical indications, preoperative rehabilitation, surgical timing, surgical strategies and postoperative rehabilitation strategies, aiming to improve the surgical treatment and rehabilitation system for ACL injuries in competitive athletes and facilitate their return to high-level sports performance after injury.

Result Analysis
Print
Save
E-mail