1.Current status and influencing factors of knowledge-attitude-practice in myopia prevention and control among children and adolescents in Ningbo
Jue WANG ; Xiaotian LIU ; Xia JIN ; Yanli ZHANG ; Hongjun LI ; Honger SUN ; Aiai CHEN ; Yuan TANG
International Eye Science 2026;26(3):518-522
AIM:To investigate the current status and influencing factors of knowledge-attitude-practice in myopia prevention and control among children and adolescents in Ningbo City, thereby providing a scientific basis for formulating targeted prevention strategies.METHODS: Children and adolescents aged 6-12 years old were selected from the medical-school collaborative myopia prevention network in Ningbo City between August 2024 and May 2025 using stratified cluster sampling. Information on myopia prevention knowledge(15 items)and practice(9 items)was collected through questionnaire surveys. Logistic regression models were used to analyze factors influencing myopia occurrence in children and adolescents.RESULTS: A total of 664 children and adolescents aged 6-12 years were enrolled in this study. Participants were divided by age into three groups: 6-7 years old(n=221), 8-9 years old(n=221), and 10-12 years old(n=222). Of the 664 questionnaires distributed, 637 valid questionnaires were returned(201 from the 6-7 age group, 235 from the 8-9 age group, and 201 from the 10-12 age group), yielding an effective response rate of 95.9%. Based on myopia screening results, the non-myopic group comprised 203 participants(31.9%), including 100 males and 103 females, with a mean age of 8.82±1.98 years old. The myopic group comprised 434 participants(68.1%), including 213 males and 221 females, with a mean age of 9.10±1.95 years old. The myopia prevalence rates in the 6-7, 8-9, and 10-12 age groups were 37.8%(76/201), 71.9%(169/235), and 94.0%(189/201), respectively(P<0.001). Regarding the knowledge and practice of myopia prevention, the overall awareness rate in the non-myopic group(59.7%±9.7%)was significantly higher than that in the myopic group(48.7%±8.5%; P<0.001). Additionally, the non-myopic group scored higher on the key practice of “regular eye examinations”(4.27±0.96)compared to the myopic group(4.10±1.05; P<0.05). Logistic regression analysis indicated that age was the primary risk factor for myopia occurrence.CONCLUSION: Age is the dominant factor in the onset of myopia, and there is a phenomenon of “knowledge-practice gap”; the traditional health education model has limitations, and a precise prevention and control system based on developmental patterns should be established.
2.Prediction of Mismatch Repair Deficiency Status in Endometrial Cancer Using Multiparametric MRI Radiomics and Deep Learning: A Multimodal Model with Preliminary Validation
Liru WANG ; Shangying YANG ; Boyu CHEN ; Fuze CONG ; Xinran LI ; Xinyu LIU ; Huadan XUE ; Zhengyu JIN ; Yang XIANG ; Yonglan HE ; Yuan LI
Medical Journal of Peking Union Medical College Hospital 2026;17(4):976-984
To explore the clinical value of a multimodal predictive model based on multiparametric magnetic resonance imaging(MRI) radiomics combined with deep learning(DL) features for the preoperative noninvasive assessment of mismatch repair-deficient(MMRd) status in endometrial cancer(EC). Patients diagnosed with EC at Peking Union Medical College Hospital from January 2015 to December 2021 were retrospectively enrolled and randomly divided into a training set and a validation set at a ratio of 8∶2. Relevant clinical data were collected, and radiomics features and DL features were extracted from preoperative contrast-enhanced T1-weighted imaging(CE-T1WI), fat-suppressed T2-weighted imaging(fs-T2WI), and diffusion-weighted imaging(DWI) sequences. High-dimensional feature selection and dimensionality reduction were performed sequentially using the recursive feature elimination(RFE) algorithm to generate a radiomics score(Rad-score) and a deep learning score(DL-score), respectively. Multivariate logistic regression was utilized to construct a clinical model, a pure radiomics model, a clinical-radiomics model, and an integrated multimodal model incorporating clinical indicators, Rad-score, and DL-score. Model performance was assessed and compared using area under receiver operating characteristic curve(AUC) and DeLong test. A total of 509 patients were enrolled in this study, comprising 413 in the training cohort and 96 in the validation cohort. Independent predictors: Multivariate analysis indicated that preoperative fasting blood glucose level, histological grade, lymph node metastasis status, Rad-score, and DL-score were all independent significant predictors of MMRd status in EC patients. The integrated multimodal model demonstrated optimal predictive performance with an AUC of 0.699(95% CI: 0.635-0.763) in the training set, which was superior to the clinical model(AUC=0.629, 95% CI: 0.561-0.697) and the pure radiomics model(AUC=0.641, 95% CI: 0.575-0.706). In the validation set, the integrated model maintained good generalizability, achieving an AUC of 0.655(95% CI: 0.535-0.775), and its diagnostic efficacy was higher than that of the clinical model(AUC=0.578, 95% CI: 0.450-0.705) and the pure radiomics model(AUC=0.611, 95% CI: 0.488-0.734). According to the DeLong test, the incorporation of DL features resulted in the clinicalradiomicsdeep learning model performing better than both the clinicalonly model( The initially developed clinical-radiomics-deep learning model exhibits a certain predictive potential for the MMRd status in patients with EC. The inclusion of DL features may help complement the limitations of traditional evaluations, offering a preliminary radiological reference for preoperative non-invasive screening. However, given the current diagnostic performance, its overall accuracy and clinical generalizability warrant further validation in multi-center, large-sample external cohort studies.
3.Establishment of Objective Indicators and Evaluation System for "Excellent Shape and High Quality" Characteristics of Authentic Ophiopogonis Radix
Bocheng WANG ; Yan JIN ; Yuanbai LI ; Danping FAN ; Guanglei MA ; Lei LEI ; Wei LIU ; Yuan YUAN
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(18):7-15
ObjectiveTo construct a new quality classification method for Ophiopogonis Radix by systematically quantifying and integrating its appearance traits and bioactive components as objective indicators according to the theory of excellent shape, high quality, and superior effect of authentic medicinal materials. MethodsWith Ophiopogonis Radix from Zhejiang (a traditionally recognized authentic variety) as the research model, extensive samples were collected. Through textual research on classical herbal literature and modern references, root tuber length and hardness were selected as representative indicators of traditional appearance traits. These indicators were accurately measured by a digital vernier caliper and a universal testing machine for objective quantification. According to prescription data and literature review results, total saponins, total polysaccharides, and total flavonoids were chosen as key component indicators, and their content was determined. Descriptive statistics, cluster analysis, and other methods were comprehensively employed to identify the core objective indicators and their threshold ranges defining the excellent shape and high quality. The constructed evaluation system was subsequently applied to Ophiopogonis Radix from Zhejiang and Sichuan to verify its applicability. ResultsThe core quantitative indicators for the excellent shape and high quality of Ophiopogonis Radix were determined as follows: Length≥2.09 cm, hardness≤7.0 N, and content of total saponins, total polysaccharides, and total flavonoids not lower than 0.12%, 1.69%, and 0.13%, respectively. Verification results showed that this evaluation system could effectively identify Ophiopogonis Radix samples from Zhejiang, with the results consistent with traditional high-quality recognition. Its successful application to the samples from Sichuan further confirmed its cross-region universality. ConclusionThis study established an objective indicator-based evaluation system for the excellent shape and high quality of Ophiopogonis Radix, which breaks through the reliance on production regions. This system provides theoretical and methodological bases for precise quality control, scientific grading, and quality-based pricing of Ophiopogonis Radix, offering an innovative paradigm for the objective evaluation of authentic medicinal materials.
4.Objective Indicators and Evaluation System for Excellent Shape and High Quality of Gardeniae Fructus
Xiulin YUAN ; Shiwen KANG ; Zhihao LIU ; Ding HUANG ; Sen YE ; Fan LI ; Bocheng WANG ; Yan JIN ; Yuan YUAN
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(18):27-35
ObjectiveTo establish an objective evaluation system based on the quality characteristics of Gardeniae Fructus without relying on the origin label according to the theory of excellent shape, high quality, and superior effect of authentic medicinal materials, thus providing a scientific basis for the standardization of Gardeniae Fructus. MethodsDifferent batches of Gardeniae Fructus samples were collected from different producing areas. Through herbal textual research and a review of modern literature, fruit length, maximum fruit diameter, and chroma were selected as quantitative indicators to characterize the traditional appearance traits of Gardeniae Fructus. The above indicators were measured by a vernier caliper and a spectrophotometer. Through classical famous prescription data and literature analysis, total iridoid glycosides, total crocus glycosides, and total flavonoids were selected as the core component indicators related to efficacy, and their content was determined. Finally, through cluster analysis, the threshold ranges of the quantitative indicators of excellent shape and high quality were determined, and the applicability of the established evaluation system was verified by the determination of the indicators for each batch of medicinal materials. ResultsThe excellent shape indicators of Gardeniae Fructus were the fruit length-to-maximum fruit diameter ratio ≤1.86, 0°≤h≤45°, and L*≥ 37.32. The content of total iridoid glycosides, total crocus glycosides, and total flavonoids should be no less than 2.2%, 0.44%, and 0.028%, respectively. The measurement results of different batches of Gardeniae Fructus showed that the evaluation system could effectively distinguish the Gardeniae Fructus samples in line with the traditional cognition of excellent shape and high quality. ConclusionThis study preliminarily constructs an excellent shape and high quality-based quality evaluation system for Gardeniae Fructus, which links appearance traits with chemical indicators and provides a methodological basis for the quality control and scientific grading of this herbal medicine.
5.Quantification of Excellent Shape and High Quality Indicators of Sarcandrae Herba and Development of Evaluation System
Yini WU ; Zhihao LIU ; Fan LI ; Bocheng WANG ; Qiuling WANG ; Yan JIN ; Yuan YUAN
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(18):36-43
ObjectiveTo identify and quantify the excellent shape and high quality indicators of Sarcandrae Herba and establish an evaluation method for Sarcandrae Herba based on appearance traits and active components according to the theory of excellent shape, high quality, and superior effect of authentic medicinal materials. MethodsSarcandrae Herba samples from various producing areas were systematically collected. Through classical herbal textual research and modern literature analysis, colorimetric values of leaves and stems were selected as shape indicators. According to compound preparation data and literature reports, total flavonoids, total phenolic acids, and coumarins were selected as component indicators. Cluster analysis and correlation analysis were performed to identify core objective indicators and their threshold ranges for the excellent shape and high quality of Sarcandrae Herba. ResultsGreener Sarcandrae Herba exhibited higher levels of phenolic acids, total flavonoids, and coumarins. Core quantitative indicators characterizing the excellent shape and high quality of Sarcandrae Herba were Leaf a* value<0.99, stem a* value<4, phenolic acid content≥2.49%, total flavonoid content≥5.32%, and coumarin content≥1.98%. By calculating the compliance rate of each batch against this indicator system, the quality stability of different batches can be quantitatively evaluated. ConclusionThis study validates the traditional empirical principle that greener stems and leaves indicate high quality. It establishes a quality evaluation method for Sarcandrae Herba based on the correlation between color and bioactive components, providing a scientific basis for the quality control and grading of this herbal medicine.
6.Cloning, subcellular localization and expression analysis of SmIAA7 gene from Salvia miltiorrhiza
Yu-ying HUANG ; Ying CHEN ; Bao-wei WANG ; Fan-yuan GUAN ; Yu-yan ZHENG ; Jing FAN ; Jin-ling WANG ; Xiu-hua HU ; Xiao-hui WANG
Acta Pharmaceutica Sinica 2025;60(2):514-525
The auxin/indole-3-acetic acid (Aux/IAA) gene family is an important regulator for plant growth hormone signaling, involved in plant growth, development, as well as response to environmental stresses. In the present study, we identified
7.Establishment and stress analysis of a finite element model for adolescent cervical disc herniation
Yuxin ZHAO ; Liang LIANG ; Feng JIN ; Yangyang XU ; Zhijie KANG ; Yuan FANG ; Yujie HE ; Xing WANG ; Haiyan WANG ; Xiaohe LI
Chinese Journal of Tissue Engineering Research 2025;29(3):448-454
BACKGROUND:Cervical disc herniation can cause pain in the neck and shoulder area,as well as radiating pain in the upper limbs.The incidence rate is increasing year by year and tends to affect younger individuals.Fully understanding the biomechanical characteristics of the cervical spine in adolescents is of great significance for preventing and delaying the onset of cervical disc herniation in this age group. OBJECTIVE:To reconstruct cervical spine models for both healthy adolescents and adolescent patients with cervical disc herniation utilizing finite element analysis techniques,to analyze the motion range of the C1-T1 cervical vertebrae as well as the biomechanical characteristics of the annulus fibrosus,nucleus pulposus,endplates,and the cartilage of the small joints. METHODS:A normal adolescent's cervical spine and an adolescent patient with cervical disc herniation were selected in this study.The continuous scan cervical spine CT raw image data were imported into Mimics 21.0 in DICOM format.The C1-T1 vertebrae were reconstructed separately.Subsequently,the established models were imported into the 3-Matic software for disc reconstruction.The perfected models were then imported into Hypermesh software for meshing of the vertebrae,nucleus pulposus,annulus fibrosus,and ligaments,creating valid geometric models.After assigning material properties,the final models were imported into ABAQUS software to observe the joint motion range of the C1-C7 cervical vertebrae segments under different conditions,and to analyze the biomechanical characteristics of the annulus fibrosus,nucleus pulposus,endplates,and small joint cartilage of each cervical spine segment. RESULTS AND CONCLUSION:(1)In six different conditions,the joint motion range of the C1 vertebra in the cervical spine models of both normal adolescent and adolescent patient with cervical disc herniation was higher than that of the other vertebrae.Additionally,the joint motion range of each cervical spine segment in normal adolescent was greater than that in adolescent patient with cervical disc herniation.(2)In the cervical spine model of normal adolescent,the maximum stress values in the annulus fibrosus and nucleus pulposus were found on the left side during C2-3 flexion conditions(0.43 MPa and 0.17 MPa,respectively).In the cervical spine model of adolescent patient with cervical disc herniation,the maximum stress values were found on the left side during C7-T1 flexion conditions(0.54 MPa and 0.18 MPa,respectively).(3)In the cervical spine model of normal adolescent,the maximum stress value on the endplate was found on the left side of the upper endplate of C3 during flexion conditions(1.46 MPa).In the model of adolescent patient with cervical disc herniation,the maximum stress value on the endplate was found on the left side of the lower endplate of C7 during flexion conditions(1.32 MPa).(4)In the cervical spine model of normal adolescent,the maximum stress value in the small joint cartilage was found in the C2-3 left rotation conditions(0.98 MPa).In adolescent patient with cervical disc herniation,the stress in the small joint cartilage significantly increased under different conditions,especially in C1-2,with the maximum stress found during left flexion(3.50 MPa).(5)It is concluded that compared to normal adolescent,adolescent patient with cervical disc herniation exhibits altered cervical curvature and a decrease in overall joint motion range in the cervical spine.In adolescent with cervical disc herniation,there is a significant increase in stress on the annulus fibrosus,nucleus pulposus,and endplates in the C7-T1 segment.The stress on the left articular cartilage of the C1-2 is notable.Abnormal cervical curvature may be the primary factor causing these stress changes.
8.Clinical efficacy of open reduction and internal fixation with plates versus minimally invasive Kirschner wire fixation for osteoporotic Colles' fractures.
Jun-Wei ZHANG ; Jin-Yong HOU ; Zhao-Hui LI ; Zhen-Yuan MA ; Xiang GAO ; Hong-Zheng BI ; Ling-Ling CHEN ; Hai-Tao WANG ; Wei-Zhi NIE ; Yong-Zhong CHENG ; Xiao-Bing XI
China Journal of Orthopaedics and Traumatology 2025;38(1):18-24
OBJECTIVE:
To compare the short-term clinical efficacy and safety of closed reduction with Kirschner wire fixation versus open reduction with plate fixation for treating osteoporotic Colles' fractures in middle-aged and elderly patients.
METHODS:
Between January 2018 and January 2023, 119 patients with Colles fractures were retrospectively analyzed, including 39 males and 80 females, aged from 48 to 74 years old with an average of(60.58±6.71) years old. The time from injury to operation ranged 1 to 13 days with an average of (5.29±2.52) days. According to the surgical method, they were divided into Kirschner wire fixation group (Kirschner wire group) and plate internal fixation group (plate group). In Kirschner wire group, there were a total of 68 patients, comprising 21 males and 47 females. The average age was (61.15±6.24) years old, ranged from 49 to 74 years old. Among them, 41 cases involved the left side while 27 cases involved the right side. In the plate group, there were a total of 51 patients, including 18 males and 33 females. The average age was (59.78±5.71) years old ranged from 48 to 72 years old. Among them, there were 31 cases on the left side and 20 cases on the right side. The following parameters were recorded before and after the operation:operation time, intraoperative blood loss, hospitalization days, hospitalization expenses, postoperative complications, and radiographic parameters of distal radius (distal radius height, ulnar deviation angle, palmar tilt angle). The clinical efficacy was evaluated at 3 and 12 months after the operation using Gartland-Werley and disabilites of the arm shoulder and hand (DASH) scores.
RESULTS:
The patients in both groups were followed up for a duration from 12 to 19 months with an average of(13.32±2.02) months. The Kirschner wire group exhibited significantly shorter operation time compared to the plate group 27.91(13.00, 42.00) min vs 67.52(29.72, 105.32) min, Z=-8.74, P=0.00. Intraoperative blood loss was also significantly lower in the Kirschner wire group than in the plate group 3.24(1.08, 5.40) ml vs 21.91(17.38, 26.44) ml, Z=-9.31, P=0.00. Furthermore, patients in the Kirschner wire group had a shorter length of hospital stay compared to those in the plate group (8.38±2.63) days vs (11.40±2.78) days, t=-3.12, P=0.00. Additionally, hospitalization cost was significantly lower in the Kirschner wire group than in the plate group 10 111.29(6 738.98, 13 483.60) yuan vs 15 871.11(11 690.40, 20 051.82) yuan, Z=-5.62, P=0.00. The incidence of complications was 2 cases in the Kirschner wire group and 1 case in the plate group, with no statistically significant difference(P>0.05). At 3 months postoprative, the radial height of the Kirschner wire group was found to be significantly smaller than that of the plate group, with measurements of (11.45±1.69) mm and (12.11±1.78) mm respectively (t=-2.06, P=0.04). However, there were no statistically significant differences observed in ulnar deviation angle and palmar tilt angle between the two groups (P>0.05). The DASH score and Gartland-Werley score in the Kirschner group were significantly higher than those in the plate group at 3 months post-operation (19.10±9.89) vs (13.47±3.51), t=4.34, P=0.00;(11.15±3.61) vs (6.41±2.75), t=8.13, P=0.00). However, there was no significant difference between the two groups at 12 months post-operation (P>0.05).
CONCLUSION
Compared to plate internal fixation, closed reduction with Kirschner wire support fixation yields a slightly inferior recovery of radial height;however, there is no significant disparity in the functional score of the affected limb at 12 months post-operation. Nonetheless, this technique offers advantages such as shorter operation time, reduced intraoperative blood loss, decreased hospitalization duration, and lower cost.
Humans
;
Female
;
Male
;
Middle Aged
;
Aged
;
Fracture Fixation, Internal/instrumentation*
;
Bone Wires
;
Bone Plates
;
Retrospective Studies
;
Colles' Fracture/surgery*
;
Minimally Invasive Surgical Procedures/methods*
;
Open Fracture Reduction/methods*
;
Osteoporotic Fractures/surgery*
9.Application of 3D-printed auxiliary guides in adolescent scoliosis surgery.
Dong HOU ; Jian-Tao WEN ; Chen ZHANG ; Jin HUANG ; Chang-Quan DAI ; Kai LI ; Han LENG ; Jing ZHANG ; Shao-Bo YANG ; Xiao-Juan CUI ; Juan WANG ; Xiao-Yun YUAN
China Journal of Orthopaedics and Traumatology 2025;38(11):1119-1125
OBJECTIVE:
To investigate the accuracy and safety of pedicle screw placement using 3D-printed auxiliary guides in scoliosis correction surgery for adolescents.
METHODS:
A retrospective analysis was conducted on the clinical data of 51 patients who underwent posterior scoliosis correction surgery from January 2020 to March 2023. Among them, there were 35 cases of adolescent idiopathic scoliosis and 16 cases of congenital scoliosis. The patients were divided into two groups based on the auxiliary tool used:the 3D-printed auxiliary guide screw placement group (3D printing group) and the free-hand screw placement group (free-hand group, without auxiliary tools). The 3D printing group included 32 patients (12 males and 20 females) with an average age of (12.59±2.60) years;the free-hand group included 19 patients (7 males and 12 females) with an average age of (14.58±3.53) years. The two groups were compared in terms of screw placement accuracy and safety, spinal correction rate, intraoperative blood loss, number of intraoperative fluoroscopies, operation time, hospital stay, and preoperative and last follow-up scores of the Scoliosis Research Society-22 (SRS-22) questionnaire.
RESULTS:
A total of 707 pedicle screws were placed in the two groups, with 441 screws in the 3D printing group and 266 screws in the free-hand group. All patients in both groups successfully completed the surgery. There was a statistically significant difference in operation time between the two groups (P<0.05). The screw placement accuracy rate of the 3D printing group was 95.46% (421/441), among which the Grade A placement rate was 89.34% (394/441);the screw placement accuracy rate of the free-hand group was 86.47% (230/266), with a Grade A placement rate of 73.31% (195/266). There were statistically significant differences in the accuracy of Grade A, B, and C screw placements between the two groups (P<0.05), while no statistically significant differences were observed in intraoperative blood loss, number of fluoroscopies, correction rate, or hospital stay (P>0.05). In the SRS-22 questionnaire scores, the scores of functional status and activity ability, self-image, mental status, and pain of patients in each group at the last follow-up were significantly improved compared with those before surgery (P<0.05), but there were no statistically significant differences in all scores between the two groups (P>0.05).
CONCLUSION
In scoliosis correction surgery, compared with traditional free-hand screw placement, the use of 3D-printed auxiliary guides for screw placement significantly improves the accuracy and safety of screw placement and shortens the operation time.
Humans
;
Male
;
Scoliosis/surgery*
;
Female
;
Adolescent
;
Printing, Three-Dimensional
;
Retrospective Studies
;
Pedicle Screws
;
Child
10.Advances in the study of viruses inhibiting the production of advanced autophagy or interferon through Rubicon to achieve innate immune escape.
Junwei SU ; Jin YUAN ; Feng WANG ; Jun LI ; Lei YUE ; Min YAN
Chinese Journal of Cellular and Molecular Immunology 2025;41(1):83-89
The innate immune response is the first line of defense for the host against viral infections. Targeted degradation of pathogenic microorganisms through autophagy, in conjunction with pattern recognition receptors synergistically inducing the production of interferon (IFN), constitutes an important pathway for the body to resist viral infections. Rubicon, a Run domain Beclin 1-interacting and cysteine-rich domain protein, has an inhibitory effect on autophagy and IFN production. On the one hand, Rubicon, as a component of the phosphoinositide 3-kinase (PI3K) complex, interacts with different domains of vacuolar protein sorting 34 (Vps34), ultraviolet radiation resistance associated gene (UVRAG), guanosine triphosphate (GTP) kinase, and RAS oncogene family member 7 (Rab7) to mediate the inhibition of autophagy maturation; on the other hand, Rubicon inhibits the ubiquitination of nuclear factor κB essential modulator (NEMO) and the dimerization of interferon regulatory factor 3 (IRF3), thereby blocking the signal transduction related to IFN production. Research has revealed that various viruses, such as Kaposi's sarcoma-associated herpesvirus (KSHV), hepatitis B virus (HBV), Sendai virus (SeV), and hepatitis C virus (HCV), achieve innate immune evasion by regulating the expression or function of Rubicon. Rubicon is expected to be a new target for antiviral therapy.
Humans
;
Autophagy/immunology*
;
Immunity, Innate
;
Interferons/immunology*
;
Immune Evasion
;
Animals
;
Virus Diseases/virology*
;
Signal Transduction
;
Viruses/immunology*
;
Intracellular Signaling Peptides and Proteins/immunology*
;
Autophagy-Related Proteins

Result Analysis
Print
Save
E-mail