1.Molecular determinants of outcome to gemcitabine, cisplatin, and nab-paclitaxel in patients with advanced biliary tract cancer
Daeseong KIM ; Nam Suk SIM ; Seonjeong WOO ; Min Hwan KIM ; Choong-kun LEE ; Seung Soo HONG ; Sung Hyun KIM ; Ho Kyoung HWANG ; Chang Moo KANG ; Woo Jung LEE ; Jung Hyun JO ; Taek CHUNG ; Sohyun HWANG ; Beodeul KANG ; Jung Sun KIM ; Chang-Il KWON ; Sangwoo KIM ; Hong Jae CHON ; Chang Gon KIM ; Young Nyun PARK ; Hye Jin CHOI
Clinical and Molecular Hepatology 2026;32(2):721-736
Background/Aims:
Biliary tract cancer (BTC) is a rare malignancy with poor prognosis. We investigated genomic determinants of clinical benefit from gemcitabine, cisplatin, and nab-paclitaxel (GAP) versus gemcitabine and cisplatin (GC) in advanced BTC.
Methods:
Clinical and genomic data using TruSight Oncology 500 were analyzed from patients treated with GAP (N=198) or GC (N=89) as first-line therapy.
Results:
With a median follow-up of 33.0 months, GAP modestly improved progression-free survival (PFS) (hazard ratio [HR] 0.764; 95% confidence interval [CI] 0.591–0.989) without significant overall survival (OS) difference compared to GC. Genomic profiling revealed frequent alterations in TP53 (35.2%), KRAS (16.4%), SMAD4 (10.5%), and TNFRSF14 (10.5%), involving RTK/RAS (44.3%), TP53 (41.8%), and PI3K (20.2%) pathways. Single-gene mutations did not predict treatment benefit. However, pathway-level analysis identified PI3K pathway activation as significantly associated with inferior PFS (HR 2.148; 95% CI 1.478–3.124) and OS (HR 2.096; 95% CI 1.413–3.109) in patients receiving GAP, an effect not observed with GC. Importantly, GAP conferred clinical benefit only in patients without PI3K pathway activation, while no survival advantage was seen in those with such alterations (Pinteraction=0.023 for PFS, Pinteraction=0.003 for OS). Similar results were obtained in the independent validation cohort treated with GAP (N=103) or GC (N=64) for BTC.
Conclusions
Genomic profiling using next-generation sequencing identified PI3K pathway activation as key molecular determinant that differentiates patient outcomes between GAP and GC treatments in advanced BTC.
2.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
3.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
4.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
5.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
6.Practice guidelines for managing extrahepatic biliary tract cancers
Hyung Sun KIM ; Mee Joo KANG ; Jingu KANG ; Kyubo KIM ; Bohyun KIM ; Seong-Hun KIM ; Soo Jin KIM ; Yong-Il KIM ; Joo Young KIM ; Jin Sil KIM ; Haeryoung KIM ; Hyo Jung KIM ; Ji Hae NAHM ; Won Suk PARK ; Eunkyu PARK ; Joo Kyung PARK ; Jin Myung PARK ; Byeong Jun SONG ; Yong Chan SHIN ; Keun Soo AHN ; Sang Myung WOO ; Jeong Il YU ; Changhoon YOO ; Kyoungbun LEE ; Dong Ho LEE ; Myung Ah LEE ; Seung Eun LEE ; Ik Jae LEE ; Huisong LEE ; Jung Ho IM ; Kee-Taek JANG ; Hye Young JANG ; Sun-Young JUN ; Hong Jae CHON ; Min Kyu JUNG ; Yong Eun CHUNG ; Jae Uk CHONG ; Eunae CHO ; Eui Kyu CHIE ; Sae Byeol CHOI ; Seo-Yeon CHOI ; Seong Ji CHOI ; Joon Young CHOI ; Hye-Jeong CHOI ; Seung-Mo HONG ; Ji Hyung HONG ; Tae Ho HONG ; Shin Hye HWANG ; In Gyu HWANG ; Joon Seong PARK
Annals of Hepato-Biliary-Pancreatic Surgery 2024;28(2):161-202
Background:
s/Aims: Reported incidence of extrahepatic bile duct cancer is higher in Asians than in Western populations. Korea, in particular, is one of the countries with the highest incidence rates of extrahepatic bile duct cancer in the world. Although research and innovative therapeutic modalities for extrahepatic bile duct cancer are emerging, clinical guidelines are currently unavailable in Korea. The Korean Society of Hepato-Biliary-Pancreatic Surgery in collaboration with related societies (Korean Pancreatic and Biliary Surgery Society, Korean Society of Abdominal Radiology, Korean Society of Medical Oncology, Korean Society of Radiation Oncology, Korean Society of Pathologists, and Korean Society of Nuclear Medicine) decided to establish clinical guideline for extrahepatic bile duct cancer in June 2021.
Methods:
Contents of the guidelines were developed through subgroup meetings for each key question and a preliminary draft was finalized through a Clinical Guidelines Committee workshop.
Results:
In November 2021, the finalized draft was presented for public scrutiny during a formal hearing.
Conclusions
The extrahepatic guideline committee believed that this guideline could be helpful in the treatment of patients.
7.KASL clinical practice guidelines for noninvasive tests to assess liver fibrosis in chronic liver disease
Mi Na KIM ; Ji Won HAN ; Jihyun AN ; Beom Kyung KIM ; Young-Joo JIN ; Seung-seob KIM ; Minjong LEE ; Han Ah LEE ; Yuri CHO ; Hee Yeon KIM ; Yu Rim SHIN ; Jung Hwan YU ; Moon Young KIM ; YoungRok CHOI ; Young Eun CHON ; Eun Ju CHO ; Eun Joo LEE ; Sang Gyune KIM ; Won KIM ; Dae Won JUN ; Seung Up KIM ;
Clinical and Molecular Hepatology 2024;30(suppl):s5-s105
8.Prevalence of clinically significant liver fibrosis in the general population: A systematic review and meta-analysis
Hee Yeon KIM ; Jung Hwan YU ; Young Eun CHON ; Seung Up KIM ; Mi Na KIM ; Ji Won HAN ; Han Ah LEE ; Young-Joo JIN ; Jihyun AN ; Miyoung CHOI ; Dae Won JUN
Clinical and Molecular Hepatology 2024;30(suppl):s199-s213
Background/Aims:
Although important, clinically significant liver fibrosis is often overlooked in the general population. We aimed to examine the prevalence of clinically significant liver fibrosis using noninvasive tests (NITs) in the general population.
Methods:
We collected data from four databases (MEDLINE, Embase, Cochrane Library, and KoreaMed) from inception to June 13, 2023. Original articles reporting the prevalence of clinically significant liver fibrosis in the general population were included. The Stata metaprop function was used to obtain the pooled prevalence of liver fibrosis with NITs in the general population.
Results:
We screened 6,429 articles and included 45 eligible studies that reported the prevalence of clinically significant liver fibrosis in the general population. The prevalence of advanced liver fibrosis, using the high probability cutoff of the fibrosis-4 (FIB-4) index, was 2.3% (95% confidence interval [CI], 1.2–3.7%). The prevalence of significant liver fibrosis, advanced liver fibrosis, and liver cirrhosis, assessed using vibration-controlled transient elastography (VCTE) among the general population, was 7.3% (95% CI, 5.9–8.8%), 3.5% (95% CI, 2.7–4.5), and 1.2% (95% CI, 0.8–1.8%), respectively. Region-based subgroup analysis revealed that the highest prevalence of advanced fibrosis using the high probability cutoff of the FIB-4 index was observed in the American region. Furthermore, the American region exhibited the highest prevalence of significant liver fibrosis, advanced liver fibrosis, and liver cirrhosis, using VCTE.
Conclusions
Previously undiagnosed clinically significant liver fibrosis is found in the general population through NITs. Future research is necessary to stratify the risk in the general population.
9.Risk assessment of hepatitis B virus-related hepatocellular carcinoma development using vibration-controlled transient elastography: Systematic review and meta-analysis
Young-Joo JIN ; Hee Yeon KIM ; Young Ju SUH ; Chae Hyeon LEE ; Jung Hwan YU ; Mi Na KIM ; Ji Won HAN ; Han Ah LEE ; Jihyun AN ; Young Eun CHON ; Dae Won JUN ; Miyoung CHOI ; Seung Up KIM
Clinical and Molecular Hepatology 2024;30(suppl):s159-s171
Background:
s/Aims: Liver stiffness measurement (LSM) using vibration-controlled transient elastography (VCTE) can assess fibrotic burden in chronic liver diseases. The systematic review and meta-analysis was conducted to determine whether LSM using VCTE can predict the risk of development of hepatocellular carcinoma (HCC) in chronic hepatitis B (CHB) patients.
Methods:
A systematic literature search of the Ovid-Medline, EMBASE, Cochrane, and KoreaMed databases (from January 2010 to June 2023) was conducted. Of the 1,345 individual studies identified, 10 studies that used VCTE were finally registered. Hazard ratios (HRs) and the 95% confidence intervals (CIs) were considered summary estimates of treatment effect sizes of ≥11 kilopascal (kPa) standard for HCC development. Meta-analysis was performed using the restricted Maximum Likelihood random effects model.
Results:
Among the ten studies, data for risk ratios for HCC development could be obtained from nine studies. When analyzed for the nine studies, the HR for HCC development was high at 3.33 (95% CI, 2.45–4.54) in CHB patients with a baseline LSM of ≥11 kPa compared to patients who did not. In ten studies included, LSM of ≥11 kPa showed the sensitivity and specificity for predicting HCC development were 61% (95% CI, 50–71%) and 78% (95% CI, 66–86%), respectively, and the diagnostic accuracy was 0.74 (95% CI, 0.70–0.77).
Conclusions
The risk of HCC development was elevated in CHB patients with VCTE-determined LSM of ≥11 kPa. This finding suggests that VCTE-determined LSM values may aid the risk prediction of HCC development in CHB patients.
10.Diagnostic accuracy of the Fibrosis-4 index for advanced liver fibrosis in nonalcoholic fatty liver disease with type 2 diabetes: A systematic review and meta-analysis
Ji Won HAN ; Hee Yeon KIM ; Jung Hwan YU ; Mi Na KIM ; Young Eun CHON ; Ji Hyun AN ; Young-Joo JIN ; Miyoung CHOI ; Seung Up KIM ; Han Ah LEE ; Dae Won JUN
Clinical and Molecular Hepatology 2024;30(suppl):s147-s158
Background/Aims:
The Fibrosis-4 index (FIB-4) is a noninvasive test widely used to rule out advanced liver fibrosis (AF) in patients with nonalcoholic fatty liver disease (NAFLD). However, its diagnostic accuracy in NAFLD patients with type 2 diabetes mellitus (T2DM) is controversial due to the high prevalence of AF in this population.
Methods:
Research focusing on the diagnostic accuracy of FIB-4 for liver fibrosis as validated by liver histology in NAFLD patients with T2DM was included, and 12 studies (n=5,624) were finally included in the meta-analysis. Sensitivity, specificity, hierarchical summary receiver operating characteristic (HSROC), positive predictive values (PPVs), and negative predictive values (NPVs) at low cutoffs (1.3–1.67) and high cutoffs (2.67–3.25) for ruling in and out AF were calculated.
Results:
At low cutoffs, the meta-analysis revealed a sensitivity of 0.74, specificity of 0.62, and HSROC of 0.75. At high cutoffs, the analysis showed a sensitivity of 0.33, specificity of 0.92, and HSROC of 0.85, suggesting FIB-4 as useful for identifying or excluding AF. In subgroup analyses, high mean age and F3 prevalence were associated with lower sensitivity. The calculated NPV and PPV were 0.82 and 0.49 at low cutoffs, whereas the NPV was 0.28 and the PPV was 0.70 at high cutoffs. There were insufficient estimated NPVs <0.90 at a hypothesized prevalence of AF >30% at an FIB-4 cutoff range of 1.3–1.67.
Conclusions
Collectively, FIB-4 has moderate diagnostic accuracy for identifying or excluding AF in NAFLD patients with T2DM, but more evidence must be accumulated due to the limited number of currently reported studies and their heterogeneity.

Result Analysis
Print
Save
E-mail