1.Risk Assessment for Ramadan Fasting in People With Diabetes in Hospital-Based Diabetes Clinics Using the Updated 2026 IDF-DAR Risk Calculator
Raja Nurazni Raja Azwan ; Chin Voon Tong ; Lisa Mohamed Nor ; Marisa Khatijah Borhan ; Syarifah Syahirah Syed Abas ; Poh Shean Wong ; Ying Jie Tan ; Shartiyah Ismail ; Eunice Yi Chwen Lau ; Yueh Chien Kuan ; Noor Hafis Md Tob ; Shu Teng Chai ; Pei Lin Chan ; Xe Hui Lee ; Wei Wei Ng ; Jin Hui Ho ; Miza Hiryanti Zakaria ; Rabeah Md Zuki ; Wan Mohd Hafez Wan Hamzah ; Melissa Vergis ; Choon Peng Sun ; Vanusha Devaraja Pillai ; Chee Koon Low ; Shazatul Reza Mohd Redzuan ; Xin-Yi Ooi ; Siti Sanaa Wan Azman ; Deviga Lachumanan ; Saiful Shahrizal Shudim ; Zanariah Hussein
Journal of the ASEAN Federation of Endocrine Societies 2026;41(S1):42-43
Introduction:
The 2021 IDF-DAR risk calculator had been previously
evaluated in multiple studies and subsequently widely
accepted and applied in clinical practice as a practical
standardized tool for patient risk stratification. Recently
updated, the 2026 IDF-DAR Risk calculator enables a more individualized, evidence-related evaluation of patientrelated and disease-related risk factors, incorporating
modern diabetes technologies, including continuous
glucose monitoring (CGM), automated insulin delivery
(AID) systems, and advanced insulin formulations to
enhance risk stratification. This tool allows medical
professionals to tailor Ramadan practices based on overall
factors toward promoting safe fasting.
Methodology:
This prospective multicentre observational study recruited
adults with Type 1 and Type 2 diabetes attending public
hospitals nationwide. People with diabetes (PwD) intending
to perform Ramadan fasting were invited to participate
and assessed using the 2026 IDF-DAR Risk Calculator in
the 6-week pre-Ramadan period between 30th January and
19th March 2026.
Results:
A total of 458 PwD were evaluated and stratified into low
(15.7%), moderate (41%), and high risk (43.3%) categories.
Most participants had Type 2 diabetes (83.6%), with 60.3%
having a disease duration exceeding 10 years and 43%
exhibiting poor glycemic control (hemoglobin A1c >9%).
Insulin therapy was used by 76.4% of participants, including
two individuals with Type 1 diabetes using AID systems.
Most participants reported no recent hypoglycemia (76.4%),
81.0% performed glucose monitoring, and 3.3% used CGM.
Severe comorbidities were uncommon, with 1.1% having
unstable macrovascular disease and 4.4% advanced chronic
kidney disease (estimated glomerular filtration rate <30).
Notably, 72.2% received structured Ramadan education.
Conclusion
Majority of PwD attending tertiary diabetes clinics were
in the moderate- to high-risk category and intended to
fast despite medical advice against fasting in some cases.
Although most participants were on insulin therapy,
hypoglycemia was low in the pre-Ramadan period.
Integration of modern technologies, advanced insulin
therapies, and structured education may support safer
fasting practices.
Risk Assessment
;
Diabetes Mellitus
;
Hospitals
;
Fasting
2.Reactive and Enzyme-activated Probe Strategies for Imaging Acute Kidney Injury
Ru-Long CHEN ; Ting-Fei XIE ; Jin-Xin ZHANG ; Jia-Ting CHEN ; Jie LI ; Peng-Fei ZHANG ; Ji-Hong CHEN ; Lin-Tao CAI
Progress in Biochemistry and Biophysics 2026;53(6):1622-1637
Acute kidney injury (AKI) is a prevalent and life-threatening clinical syndrome characterised by a rapid decline in renal function and diverse pathological etiologies. The condition has been demonstrated to be associated with elevated mortality rates and an increased risk of progression to chronic kidney disease. At present, clinicians depend heavily on conventional functional markers, such as serum creatinine and urine output, for the diagnosis and staging of the disease. It is evident that these conventional indicators characteristically manifest a considerable temporal delay and only undergo modification subsequent to considerable tissue damage. This severely restricts the timeframe for early detection and timely therapeutic intervention. Furthermore, standard markers fail to provide specific biological information regarding the underlying cellular injury mechanisms. The utilisation of advanced probe technologies in molecular imaging offers a robust alternative to overcome these inherent diagnostic limitations.This comprehensive review systematically evaluates recent progress in the design and application of two primary categories of molecular imaging tools for acute kidney disease, specifically reactive probes and enzyme-activated probes. Reactive probes are engineered to specifically interact with redox-active chemical species, including hydrogen peroxide, peroxynitrite, hypochlorous acid, and sulfur dioxide. Because oxidative stress constitutes a primary early event in acute renal tubular damage, these probes enable researchers and clinicians to visualize early cellular injury and radical accumulation well before global renal functional decline becomes evident. We discuss the application of these reactive probes across multiple imaging modalities including fluorescence imaging, magnetic resonance imaging (MRI), positron emission tomography (PET), and photoacoustic techniques. Photoacoustic imaging combines high spatial resolution with deep tissue penetration and has successfully demonstrated the ability to provide diagnostic alerts up to 12 h before any detectable rise in serum creatinine levels. Additionally, specific reactive probes have shown promising translational potential when tested by high-throughput screening in clinical human urine samples. Enzyme-activated probes target the specific catalytic activity of disease-relevant enzymes. These include well-documented renal tubular structural biomarkers such as NAG, GGT, and ALP, along with apoptosis-related caspases and specific nitroreductases. By responding only to enzymatic cleavage, these tools provide highly specific and pathology-directed imaging readouts. Recent structural design strategies in this field have advanced significantly beyond single-enzyme detection. Researchers are now focusing on sophisticated dual-target recognition to minimize background noise, multimodal integration to cross-validate imaging signals, and theranostic applications where probes simultaneously deliver diagnostic feedback and therapeutic agents to injured tissues. Nanotechnology serves as a fundamental enabler for realizing these advanced probe functions. By precisely optimizing nanoparticle parameters such as hydrodynamic size, surface charge, and targeting ligands, researchers can achieve amplified signal output, highly precise kidney delivery, and protection against premature degradation in the systemic circulation. For example, modifying surface charges can significantly enhance the active uptake of nanoprobes by damaged renal tubular epithelial cells.While preclinical probe development has progressed rapidly, moving these technologies into routine clinical practice remains a major challenge. We analyze the translational feasibility and current obstacles from biological, technological, and regulatory perspectives. Although biological targets such as KIM-1, FAP, and ALP have been validated in extensive patient cohorts, practical barriers severely limit their immediate clinical application. These obstacles involve complex changes in in vivo pharmacokinetics. During an acute injury episode, the extreme drop in the glomerular filtration rate alters probe clearance and can cause unwanted systemic accumulation or confusing background imaging signals. Other major hurdles include a lack of comprehensive long-term toxicity data and the absence of standardized manufacturing protocols to ensure batch-to-batch consistency. Future successful translation will require rigorous multi-center clinical studies to confirm the true diagnostic value of these probes over traditional markers. Researchers must also establish strict standardization of imaging procedures and comprehensive safety evaluations. Ultimately, this review provides a thorough reference framework for designing clinically translatable molecular probes and building a precision diagnostic imaging system for acute kidney injury.
3.Establishment and application of the method for plasma concentration determination of lamotrigine,levetiracetam and perampanel in children with epilepsy
Wenlin SONG ; Ying ZHOU ; Haoran CHEN ; Ziyue LIN ; Yan LI ; Jie LIU ; Taiwei JIN ; Xuqiang ZHOU
China Pharmacy 2026;37(10):1313-1317
OBJECTIVE To establish a method for simultaneous determination of plasma concentration of lamotrigine(LTG), levetiracetam(LEV) and perampanel(PER) in children with epilepsy and apply this method in clinical practice. METHODS Plasma proteins were precipitated with acetonitrile. Using PER-D 5 as internal standard, ultra-high performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method was adopted. The determination was performed on ACQUITY UPLC HSS T3 C 18 column with mobile phase consisted of 0.1% formic acid with 5 mmol/L ammonium acetate-acetonitrile (gradient elution) at the flow rate of 0.3 mL/min. The column temperature was 40 ℃, and sample size was 5 μL. The analysis time was 5 min. The electrospray ionization source and multiple reaction monitoring mode were used for positive ion scanning. The ion pairs used for quantitative analysis of LTG, LEV, PER and internal standard were m / z 255.9→144.9, m / z 171.1→126.1, m / z 350.1→219.0 and m / z 354.9→220.2, respectively. The steady-state trough concentrations of the aforementioned drugs in the plasma of 14 pediatric epilepsy patients receiving combination therapy were determined using the same UPLC-MS/MS method as above. RESULTS The linear ranges of LTG, LEV and PER were 0.15-24 μg/mL ( R 2 >0.993), 0.312 5-50 μg/mL ( R 2 >0.997) and 6.25-1 000 ng/mL ( R 2 >0.997), respectively. The lower limits of quantification were 0.15 μg/mL, 0.312 5 μg/mL and 6.25 ng/mL, respectively. RSDs of intraday and interday precision tests of the three drugs were no more than 9.83%, and the accuracies (relative errors) were between -9.33% and 13.72%( n =6 or n =18); the average extraction recovery rates were 86.4%-97.9%, and the average matrix effects were 86.9%-110.0% ( n =6). The absolute values of the relative errors in the stability tests were all below 15%. The steady-state trough concentrations of LTG, LEV and PER were (5.64±4.03)μg/mL, (10.67±8.78)μg/mL and(450.20±251.27)ng/mL, respectively; the rates of achieving target trough concentrations were 71.4%, 37.5% and 84.6%, respectively. CONCLUSIONS The established UPLC-MS/MS method is specific, rapid and suitable for the plasma concentration monitoring in epileptic children receiving combination therapy.
4.Association of insulin-like growth factor binding protein-3 gene polymorphism at the rs10225396 locus with susceptibility to hepatocellular carcinoma
Shijie LIU ; Guang JIN ; Hesong CUI ; Shuyao SUN ; Yuke LIN ; Qingsong CUI
Journal of Clinical Hepatology 2026;42(4):882-889
ObjectiveTo investigate the association of the single nucleotide polymorphism (SNP) of the insulin-like growth factor binding protein-3 (IGFBP3) gene at rs10225396 (A>G) locus with the susceptibility to hepatocellular carcinoma, as well as its potential molecular regulatory mechanisms, and to provide novel genetic biomarkers and a theoretical basis for early screening and precise targeted therapy for hepatocellular carcinoma. MethodsA total of 192 patients with hepatocellular carcinoma who were admitted to The Affiliated Hospital of Yanbian University and Yanbian Cancer Hospital from January 2009 to August 2016 were enrolled as experimental group, and 190 healthy individuals who underwent physical examination in Physical Examination Center of Yanbian Hospital during the same period of time were enrolled as control group. Peripheral blood samples were collected from all subjects, and after DNA was extracted from whole blood, the DNA samples meeting quality standards were sent to Beijing Genomics Institute Research Center Co., Ltd., for Mass ARRAY mass spectrometry, while genotyping was completed. The independent-samples t test was used for comparison of continuous data between two groups, and the chi-square test was used for comparison of categorical data between two groups. A binary Logistic regression model was used to analyze the association of the SNP of the IGFBP3 gene at rs10225396 locus with the susceptibility to hepatocellular carcinoma, and odds ratio (OR) and 95% confidence interval (CI) were calculated to assess the risk of developing hepatocellular carcinoma in individuals carrying different genotypes. ResultsThere were two alleles (G and A) at the rs10225396 locus of the IGFBP3 gene, yielding the three genotypes of AA, AG, and GG, and its genotype distribution was consistent with the Hardy-Weinberg equilibrium (χ²=0.072, P=0.789). The stratified genetic analysis showed that carriers of the IGFBP3 rs10225396 AA genotype had a significant increased risk of hepatocellular carcinoma among individuals of age <63 years, male sex, smoking history, drinking history, and the Chinese Korean population (all P<0.001). The binary Logistic regression analysis showed that after adjustment for related risk factors in the codominant model, the population with genotype AG and GG had a significant reduction in the risk of hepatocellular carcinoma compared with the population with genotype AA (P<0.001), and in the dominant model, the population with genotype AG+GG had a significant reduction in the risk of hepatocellular carcinoma compared with the population with genotype AA (P<0.001). ConclusionThrough a genotyping analysis of hepatocellular carcinoma patients and healthy individuals in Yanbian Korean Autonomous Prefecture of Jilin Province, China, this study shows that genotype AA at rs10225396 locus of the IGFBP3 gene is significantly associated with the susceptibility to hepatocellular carcinoma, and this genotype can significantly increase the risk of developing hepatocellular carcinoma with the presence of specific risk factors, which provides a potential genetic marker for early screening and precise treatment of hepatocellular carcinoma.
5.Research progress on effects, toxic mechanisms, and risk assessment of organophosphate flame retardants on blood system
Ziyuan LI ; Lin LU ; Xiaoting JIN ; Yuxin ZHENG
Journal of Environmental and Occupational Medicine 2026;43(4):509-515
Organophosphate flame retardants (OPFRs) have been widely used as the main alternatives to bromine-based flame retardants, resulting in their widespread detection in environmental media and even in human blood. The potential health risks arising therefrom, particularly the direct impacts on the blood system, have become a focus in the field of environmental health. This article systematically reviewed the latest research progress on the hematotoxicity of OPFRs, covering three core aspects: the toxic effects aspect, which systematically elaborated on the bidirectional interference of OPFRs with coagulation function, their toxic effects on the hematopoietic system, and their disruptive effects on blood biochemical metabolism; the mechanistic analysis aspect, which dissected the multi-pathway, multi-target toxic mechanism network of OPFRs, including common pathways based on oxidative stress and inflammatory responses, the direct and indirect regulation of coagulation function mediated by nuclear receptors and endocrine disruption, and the disturbance of blood cell production at the source through disruption of the hematopoietic microenvironment; and the risk assessment aspect, which, in response to the limitations of traditional methods, focused on the application prospects and core advantages of novel approaches based on structure-activity relationships in filling data gaps and achieving precise risk prediction. This review aims to systematically summarize the research progress on the mechanisms of OPFR-induced hematotoxicity, providing systematic theoretical support for subsequent in-depth mechanistic studies, targeted epidemiological investigations, and the optimization of risk assessment models.
6.Compact Fundus Imaging System Using Shack-Hartmann Wavefront Sensing for High-speed Auto-focus
Zhe-Kai LIN ; Long CHEN ; Geng-Yong ZHENG ; Jin-Tian HUANG ; Jia-Xin DONG ; Shang-Pan YANG ; Wen-Zheng DING ; Ding-An HAN ; Xue-Hua WANG ; Ya-Guang ZENG
Progress in Biochemistry and Biophysics 2026;53(4):1076-1086
ObjectiveThe widespread adoption of portable fundus cameras for primary care and community screening is hindered by limitations in current autofocus(AF) technologies. Image-based methods relying on sharpness evaluation require iterative searches, resulting in slow convergence, while projection-based techniques are susceptible to optical artifacts and calibration errors. To address these challenges, this study introduces a novel AF system based on direct wavefront sensing, designed to deliver simultaneous high speed, high precision, and operational robustness within the compact form factor essential for portable ophthalmic devices. MethodsOur approach fundamentally reimagines the AF process by directly measuring the ocular wavefront aberration. We developed a custom portable fundus camera integrating a miniaturized Shack-Hartmann wavefront sensor (SHWS) into the optical path. An 850 nm laser diode projects a point source onto the retina via oblique illumination to minimize corneal reflections. Light scattered from this spot carries the eye’s refractive error through the imaging optics and is directed to the SHWS, positioned at a plane optically conjugate to the primary color CMOS imaging sensor. A microlens array within the SHWS samples the incident wavefront, generating a pattern of focal spots on a CCD. Real-time centroid analysis of these spots provides a map of local wavefront slopes. These measurements are processed through a singular value decomposition (SVD) algorithm to fit a Zernike polynomial basis set, enabling real-time reconstruction of the wavefront phase. The defocus component (S) is extracted from the second-order Zernike coefficients, providing a direct, quantitative measure of the refractive error in diopters. This value serves as a precise error signal in a closed-loop control system, which commands a voice-coil actuated focusing lens to its null position in a single, deterministic step, eliminating the need for iterative search algorithms. ResultsComprehensive evaluation demonstrated the system’s high performance. Testing on a calibrated model eye (OEMI-7) established a highly linear relationship between the computed defocus S and the focusing lens position across a ±20 Diopter (D) compensation range, achievable within a 5 mm mechanical travel. The system achieved a focusing precision of 0.08 D, corresponding to an 18-fold improvement over a conventional projection spot-size method tested under identical conditions. The total focus acquisition time, encompassing wavefront measurement, computation, and lens actuation, averaged under 0.5 s. Clinical validation with 25 human volunteers (50 eyes, refractive range -15 D to +10 D) confirmed practical efficacy. The wavefront-sensing AF succeeded in 92% of attempts with a mean time of 0.5 s, substantially outperforming a projection-based benchmark which achieved only a 32% success rate with an average time of 4.25 s. The system provided instantaneous directional guidance and maintained stability during minor ocular movements. Objective assessment of image quality, via amplitude contrast of retinal vasculature, showed consistent and significant enhancement following AF correction across the entire tested diopter range. ConclusionThis work successfully implements and validates a direct wavefront-sensing autofocus paradigm for portable fundus cameras. By directly quantifying and compensating for the optical defocus aberration, this method bypasses the fundamental limitations of image-processing and projection-based techniques, enabling rapid, precise, and deterministic diopter compensation. The developed system delivers an exceptional combination of a wide operational range (±20 D), high accuracy (0.08 D), fast convergence (0.5 s), and a compact physical footprint. This technology provides a practical and high-performance focusing solution capable of enhancing the reliability, throughput, and diagnostic utility of portable retinal imaging in large-scale screening applications. Future efforts will be directed towards system cost optimization and performance adaptation for diverse ocular conditions.
7.Construction of hospital preparation cost item library based on the Delphi method
Shunlong OU ; Hong LIN ; Qian JIANG ; Zhaohui JIN
China Pharmacy 2026;37(9):1122-1126
OBJECTIVE To establish a hospital preparation cost item library, providing a reference for the refined accounting management of preparation costs in medical institutions. METHODS Based on literature analysis and practical work experience, a preliminary list of cost items was drafted. The Delphi method was employed to screen and optimize the items by analyzing the questionnaire recovery rate, expert authority coefficient, item importance score, coefficient of variation, and Kendall’s W of concordance. RESULTS The questionnaire recovery rates for the two rounds of expert consultation were 95.7% and 100%, respectively; the expert authority coefficients were 0.937 and 0.939, respectively; Kendall’s W of concordance were statistically significant ( P <0.001). The finally established hospital preparation cost item library included 6 first-level items (such as raw material and packaging material costs, human resource costs, and production operation costs) and 29 second-level items (including main drug raw material costs, production personnel compensation, and finished product full-item testing costs), comprehensively covering dimensions such as raw materials and packaging materials, fixed asset depreciation and equipment maintenance, human resources, production operations, energy and environment, and R & D and other costs. CONCLUSIONS This study successfully establishes a scientific and reliable cost item library for medical institution preparations, which can guide institutions to itemize actual expenditures, provide structured evidence for autonomous pricing, and support data needs for the formulation of insurance access and payment policies for innovative preparations.
8.Establishment and Preliminary Analysis of an AG6 Mouse Encephalopathy Model Induced by Vaccinia Virus Tiantan Strain Infection
Lin YANG ; Meng JIN ; Hanqing WU ; Shun LI ; Xiaohui ZHOU
Laboratory Animal and Comparative Medicine 2026;46(1):3-10
ObjectiveA mouse model of vaccinia virus Tiantan strain (VTT)-induced encephalopathy was developed using AG6 mice. MethodsVTT was amplified by infecting Vero cells at a multiplicity of infection (MOI) of 0.01, followed by concentration and titration. After 72 h of incubation, virus-containing cells were collected and subjected to concentration. The concentrated viral suspension was serially diluted (10-fold dilutions) and added to 6-well plates containing confluent Vero cell monolayers for plaque assay. The number of plaques formed in each well was counted, and the virus titer was calculated based on the dilution factor. Fourteen 5-6-week-old AG6 mice (half male and half female, housed separately by sex) were randomly divided into a control group (n=3, PBS), a low-dose group (n=6, 1×10⁵ PFU), and a high-dose group (n=5, 5×10⁵ PFU). The mice were anesthetized by isoflurane inhalation and then infected via intranasal instillation. The mental state of the mice in each group was observed daily, and the body weight and mortality were recorded. On day 13 post-infection, 2% Evans Blue (4 mL/kg body weight) was administered via tail vein injection to assess blood-brain barrier (BBB) disruption. Subsequently, brain tissue samples were collected for immunofluorescence analysis to evaluate the activation of astrocytes and microglia. ResultsThe titer of purified VTT was 1×10⁷ PFU/mL. Compared with the control group, mice in the low-dose group showed no significant change in body weight, and no lethality was observed. In contrast, mice in the high-dose group exhibited significant weight loss starting on day 5 post-infection (P<0.05), accompanied by lethality. On day 13 post-infection, no Evans Blue extravasation was detected in the brain tissues of the low-dose group, while the olfactory bulb region of the high-dose group displayed distinct blue staining, indicating disruption of the BBB. Immunofluorescence analysis revealed no significant proliferation of astrocytes and microglia in the olfactory bulb region of the low-dose group on day 13 post-infection. In contrast, marked activation of glial cells was observable in the high-dose group. ConclusionAn animal model of VTT-induced encephalopathy in AG6 mice is successfully established, characterized by BBB disruption and reactive gliosis specifically localized to the olfactory bulb region, manifested as astrocytic and microglial proliferation.
9.Research hotspots and visual analysis on the medical artificial intelligence ethics at home and abroad
Mengze LYU ; Hongji LIN ; Ya’nan BA ; Yan ZHANG ; Jin XIE ; Yun LIU
Chinese Medical Ethics 2026;39(3):287-299
To conduct a bibliometric and keyword analysis on the domestic and international literature of medical artificial intelligence (AI) ethics, explore the research frontiers, hotspots, and development trends in this field, and provide references for promoting the construction of China’s ethical governance system on medical AI. Utilizing CiteSpace software, a comparative analysis was conducted between the reviewed domestic and international literature regarding their publication volume, author and institutional collaboration networks, as well as keyword co-occurrence, clustering, timeline graph, and burst, to explore the research hotspots and development trends in the field. A total of 2 393 Chinese and English publications were included. In recent years, research topics in medical AI ethics both domestically and internationally focused on three aspects, encompassing their theoretical research, emerging domains and their ethical risks, as well as the ethical governance and regulation of medical AI. International research hotspots included federated learning, computer-aided detection, informed consent, and other aspects, whereas domestic research hotspots were smart healthcare, responsibility ethics, ethical values, and other aspects. Internationally, greater attention was placed on ethical issues concerning population health and healthcare in the public health domain, whereas domestic research topics tended to focus more on theoretical discussions and the establishment of ethical principles. The ethical governance of medical AI represents a shared global challenge, necessitating enhanced research into both the variances and commonalities in this field.
10.Efficacy Analysis of Imatinib Neoadjuvant Therapy in Patients Undergoing Surgery for Rectal Gastrointestinal Stromal Tumors
Jiayuan DAI ; Jin XU ; Min SHEN ; Yi XIAO ; Guole LIN ; Junyang LU
JOURNAL OF RARE DISEASES 2026;5(1):27-33
To investigate the clinical efficacy of neoadjuvant imatinib in the treatment of rectal gastrointestinal stromal tumor (GIST). Patients with rectal GIST who underwent surgery at Peking Union Medical College Hospital from January 2015 to January 2025 were included. Clinical data were retrospectively analyzed. Patients were divided into the neoadjuvant therapy group (received preoperative imatinib) and the control group (underwent direct surgery without preoperative imatinib). Clinical outcomes and recurrence rates were compared between the two groups. A total of 74 patients meeting the inclusion criteria were included, with 43 included in the neoadjuvant therapy group and 31 included in the control group. Baseline evaluation showed that the median tumor diameter was significantly larger in the neoadjuvant therapy group than that in the control group [5.0(2.9, 7.1)cm Neoadjuvant therapy with imatinib can effectively reduce tumor volume in patients with rectal GIST. However, its therapeutic benefit still needs to be further validated by prospective, large-sample clinical studies with long-term follow-up.


Result Analysis
Print
Save
E-mail