1.Guidelines for the Management of Adult Subglottic and Tracheal Stenosis From the Korean Bronchoesophagological Society
Jung-Hae CHO ; Gene HUH ; Jae-Keun CHO ; Jae Won CHANG ; Jun-Ook PARK ; Young Chan LEE ; Jae Hyun JEON ; Jeon Yeob JANG ; Byeong-Ho JEONG ; Yeon Soo KIM ; Inn-Chul NAM ; Gil Joon LEE ; Woo Sik YU ; Heejin KIM ; Minhyung LEE ; Ji Won KIM ; Seung Hoon WOO ; Il-Seok PARK ; Jin Pyeong KIM ;
Clinical and Experimental Otorhinolaryngology 2026;19(1):1-20
Subglottic stenosis (SGS) and tracheal stenosis (TS) are rare conditions that can cause significant breathing difficulties and, if not properly managed, may lead to life-threatening complications. Despite their clinical importance, debate continues regarding the optimal management of adult SGS and TS, and no comprehensive guidelines have been established to date. The Korean Bronchoesophagological Society appointed a task force to develop clinical practice guidelines with the goal of providing evidence-based recommendations for managing SGS and TS in adults. The task force conducted a systematic review of the relevant literature by searching PubMed, Embase, and the Cochrane Library using predefined search terms aligned with key clinical questions. The quality of evidence was assessed using the Grading of Recommendations, Assessment, Development, and Evaluation (GRADE) approach, which also informed the formulation and reporting of the recommendations. The strength of each recommendation reflects the guideline panel’s confidence that the benefits of an intervention outweigh its risks for eligible patients. After drafting the guidelines, feedback was obtained through Delphi questionnaires completed by members of the Korean Bronchoesophagological Society. Ultimately, the committee developed 17 evidence-based recommendations across four categories: initial evaluation, medical management, surgical treatment, and postoperative management and rehabilitation. These guidelines aim to support clinicians in delivering optimal care to adult patients with SGS and TS.
2.Prosthetic rehabilitation of traumatized maxillary anterior teeth using a digital workflow: a case report
Jong-Hyun SHIN ; Sang-Ah LEE ; Lee-Ra CHO ; Chan-Jin PARK ; Kyung-Ho KO ; Yoon-Hyuk HUH
The Journal of Korean Academy of Prosthodontics 2026;64(1):84-94
The maxillary anterior region is critical for esthetics and function, requiring precise analysis and restoration when damaged by trauma. This case report presents the restorative process using a digital workflow for a patient with anterior trauma. A 22-year-old female exhibited fractures and extrusive luxation of maxillary central incisors, diagnosed with pulp necrosis. After endodontic treatment, intraoral and facial scans were performed, and provisional and definitive restorations were digitally designed. Various shade-matching techniques were employed to achieve natural esthetics. The definitive prosthesis improved harmony between the incisal edge and lower lip, as well as tooth axis, length, and zenith position, fulfilling the patient’s esthetic demands. This case suggests that combining digital technology and gingivectomy with a minimally invasive approach enables esthetic and functional restoration of the maxillary anterior region.
3.Effect of Occlusal and Margin Design on the Fracture Load of Zirconia-Lithium Disilicate Bi-layered Posterior Crowns: An in Vitro Study
Sung-Hoon KIM ; Kyung-Ho KO ; Chan-Jin PARK ; Lee-Ra CHO ; Yoon-Hyuk HUH
Journal of Korean Dental Science 2025;18(1):1-11
Purpose:
The opacity of zirconia sometimes requires a veneering material; thus lithium disilicate, a veneer material with excellent strength, can be used. This study investigated the fracture resistance of zirconia–lithium disilicate (Zr-LS2) bi-layered crowns according to the design of the substructure.
Materials and Methods:
Five groups of posterior Zr-LS2 restorations (Zirtooth and Amber LiSi-POZ) were fabricated with different zirconia substructure coverage (control group, groups half occlusal zirconia coverage; 1/2OZ, and three-quarter occlusal zirconia coverage; 3/4OZ) and margin designs (control group, groups collar margin; C-M, and collarless margin; Cl-M). All restorations were cemented with self-adhesive resin cement followed by 24-h water storage and thermocycling (10,000 cycles, 5°C and 55°C). The fracture load was measured, and failure mode analysis, fractography, and elemental analysis were performed. The one-way analysis of variance and Fisher’s exact test were performed for statistical analyses (α=.05).
Results:
A significant difference was found in the fracture load of Zr-LS2 restorations according to the zirconia coverage of the occlusal area and margin design (P<.05). Group 3/4OZ was significantly larger than the control group C and 1/2OZ (P<.05). The C-M group had greater fracture loads based on margin design than the control group C and Cl-M (P<.05).
Conclusion
The fracture resistance of posterior Zr-LS2 restorations increased with the zirconia coverage, occlusal thickness, and collar margin.
4.Prospective clinical comparative evaluation of implant-supported zirconia-lithium disilicate bilayered ceramic and metalceramic posterior prostheses: a 3-year follow-up
Hye-Seon LEE ; Kyung-Ho KO ; Chan-Jin PARK ; Lee-Ra CHO ; Yoon-Hyuk HUH
The Journal of Advanced Prosthodontics 2025;17(2):59-69
PURPOSE:
The aim of this study was to evaluate the clinical performance and survival rate of implant-supported zirconia-lithium disilicate (Zr-LiSi) bilayered ceramic prostheses over 3 years.
MATERIALS AND METHODS:
This study included 71 patients, including 34 with implant-supported metal-ceramic prostheses (control group) and 37 with implant-supported Zr-LiSi bilayered ceramic prostheses (test group). The implant survival rate and incidence of prosthetic and biological complications (veneer fractures, dislodgement of screw-access hole filling material, screw loosening, peri-implant mucositis and peri-implantitis, and marginal bone loss) were investigated. The survival rate was analyzed using Kaplan-Meier survival curves, and the identity between two groups was confirmed by the log-rank test.
RESULTS:
Both groups showed a 100% survival rate, whereas the prosthetic survival rates were 77% and 73% for the metal-ceramic and Zr-LiSi groups, respectively. Biological complications did not appear in the metal-ceramic group, and 16.2% of peri-implant mucositis occurred in the Zr-LiSi group, which was significant (P < .05). Prosthetic complications occurred in 5.8% of the metal-ceramic group with veneer fractures and did not occur in the Zr-LiSi bilayered ceramic group.
CONCLUSION
This study revealed that posterior Zr-LiSi bilayered ceramic implant prostheses showed high survival rates and similar survival rates to metal-ceramic implant prostheses; however, additional consideration should be given to avoid overcontouring. Zr-LiSi bilayered ceramic implant prostheses may be an option for posterior implant-supported prosthetic treatment.
5.Prospective clinical comparative evaluation of implant-supported zirconia-lithium disilicate bilayered ceramic and metalceramic posterior prostheses: a 3-year follow-up
Hye-Seon LEE ; Kyung-Ho KO ; Chan-Jin PARK ; Lee-Ra CHO ; Yoon-Hyuk HUH
The Journal of Advanced Prosthodontics 2025;17(2):59-69
PURPOSE:
The aim of this study was to evaluate the clinical performance and survival rate of implant-supported zirconia-lithium disilicate (Zr-LiSi) bilayered ceramic prostheses over 3 years.
MATERIALS AND METHODS:
This study included 71 patients, including 34 with implant-supported metal-ceramic prostheses (control group) and 37 with implant-supported Zr-LiSi bilayered ceramic prostheses (test group). The implant survival rate and incidence of prosthetic and biological complications (veneer fractures, dislodgement of screw-access hole filling material, screw loosening, peri-implant mucositis and peri-implantitis, and marginal bone loss) were investigated. The survival rate was analyzed using Kaplan-Meier survival curves, and the identity between two groups was confirmed by the log-rank test.
RESULTS:
Both groups showed a 100% survival rate, whereas the prosthetic survival rates were 77% and 73% for the metal-ceramic and Zr-LiSi groups, respectively. Biological complications did not appear in the metal-ceramic group, and 16.2% of peri-implant mucositis occurred in the Zr-LiSi group, which was significant (P < .05). Prosthetic complications occurred in 5.8% of the metal-ceramic group with veneer fractures and did not occur in the Zr-LiSi bilayered ceramic group.
CONCLUSION
This study revealed that posterior Zr-LiSi bilayered ceramic implant prostheses showed high survival rates and similar survival rates to metal-ceramic implant prostheses; however, additional consideration should be given to avoid overcontouring. Zr-LiSi bilayered ceramic implant prostheses may be an option for posterior implant-supported prosthetic treatment.
6.Prospective clinical comparative evaluation of implant-supported zirconia-lithium disilicate bilayered ceramic and metalceramic posterior prostheses: a 3-year follow-up
Hye-Seon LEE ; Kyung-Ho KO ; Chan-Jin PARK ; Lee-Ra CHO ; Yoon-Hyuk HUH
The Journal of Advanced Prosthodontics 2025;17(2):59-69
PURPOSE:
The aim of this study was to evaluate the clinical performance and survival rate of implant-supported zirconia-lithium disilicate (Zr-LiSi) bilayered ceramic prostheses over 3 years.
MATERIALS AND METHODS:
This study included 71 patients, including 34 with implant-supported metal-ceramic prostheses (control group) and 37 with implant-supported Zr-LiSi bilayered ceramic prostheses (test group). The implant survival rate and incidence of prosthetic and biological complications (veneer fractures, dislodgement of screw-access hole filling material, screw loosening, peri-implant mucositis and peri-implantitis, and marginal bone loss) were investigated. The survival rate was analyzed using Kaplan-Meier survival curves, and the identity between two groups was confirmed by the log-rank test.
RESULTS:
Both groups showed a 100% survival rate, whereas the prosthetic survival rates were 77% and 73% for the metal-ceramic and Zr-LiSi groups, respectively. Biological complications did not appear in the metal-ceramic group, and 16.2% of peri-implant mucositis occurred in the Zr-LiSi group, which was significant (P < .05). Prosthetic complications occurred in 5.8% of the metal-ceramic group with veneer fractures and did not occur in the Zr-LiSi bilayered ceramic group.
CONCLUSION
This study revealed that posterior Zr-LiSi bilayered ceramic implant prostheses showed high survival rates and similar survival rates to metal-ceramic implant prostheses; however, additional consideration should be given to avoid overcontouring. Zr-LiSi bilayered ceramic implant prostheses may be an option for posterior implant-supported prosthetic treatment.
7.Prospective clinical comparative evaluation of implant-supported zirconia-lithium disilicate bilayered ceramic and metalceramic posterior prostheses: a 3-year follow-up
Hye-Seon LEE ; Kyung-Ho KO ; Chan-Jin PARK ; Lee-Ra CHO ; Yoon-Hyuk HUH
The Journal of Advanced Prosthodontics 2025;17(2):59-69
PURPOSE:
The aim of this study was to evaluate the clinical performance and survival rate of implant-supported zirconia-lithium disilicate (Zr-LiSi) bilayered ceramic prostheses over 3 years.
MATERIALS AND METHODS:
This study included 71 patients, including 34 with implant-supported metal-ceramic prostheses (control group) and 37 with implant-supported Zr-LiSi bilayered ceramic prostheses (test group). The implant survival rate and incidence of prosthetic and biological complications (veneer fractures, dislodgement of screw-access hole filling material, screw loosening, peri-implant mucositis and peri-implantitis, and marginal bone loss) were investigated. The survival rate was analyzed using Kaplan-Meier survival curves, and the identity between two groups was confirmed by the log-rank test.
RESULTS:
Both groups showed a 100% survival rate, whereas the prosthetic survival rates were 77% and 73% for the metal-ceramic and Zr-LiSi groups, respectively. Biological complications did not appear in the metal-ceramic group, and 16.2% of peri-implant mucositis occurred in the Zr-LiSi group, which was significant (P < .05). Prosthetic complications occurred in 5.8% of the metal-ceramic group with veneer fractures and did not occur in the Zr-LiSi bilayered ceramic group.
CONCLUSION
This study revealed that posterior Zr-LiSi bilayered ceramic implant prostheses showed high survival rates and similar survival rates to metal-ceramic implant prostheses; however, additional consideration should be given to avoid overcontouring. Zr-LiSi bilayered ceramic implant prostheses may be an option for posterior implant-supported prosthetic treatment.
8.Clinicopathological Correlations of Neurodegenerative Diseases in the National Brain Biobank of Korea
Young Hee JUNG ; Jun Pyo KIM ; Hee Jin KIM ; Hyemin JANG ; Hyun Jeong HAN ; Young Ho KOH ; Duk L. NA ; Yeon-Lim SUH ; Gi Yeong HUH ; Jae-Kyung WON ; Seong-Ik KIM ; Ji-Young CHOI ; Sang Won SEO ; Sung-Hye PARK ; Eun-Joo KIM
Journal of Clinical Neurology 2025;21(3):190-200
Background:
and Purpose The National Brain Biobank of Korea (NBBK) is a brain bank consortium supported by the Korea Disease Control and Prevention Agency and the Korea National Institute of Health, and was launched in 2015 to support research into neurodegenerative disease dementia (NDD). This study aimed to introduce the NBBK and describes clinicopathological correlations based on analyses of data collected from the NBBK.
Methods:
Four hospital-based brain banks have been established in South Korea: Samsung Medical Center Brain Bank (SMCBB), Seoul National University Hospital Brain Bank (SNUHBB), Pusan National University Hospital Brain Bank (PNUHBB), and Myongji Hospital Brain Bank (MJHBB). Clinical and pathological data were collected from these brain banks using standardized protocols. The prevalence rates of clinical and pathological diagnoses were analyzed in order to characterize the clinicopathological correlations.
Results:
Between August 2016 and December 2023, 185 brain specimens were collected and pathologically evaluated (SNUHBB: 117; PNUHBB: 27; SMCBB: 34; MJHBB: 7). The age at consent was 70.8±12.6 years, and the age at autopsy was 71.7±12.4 years. The four-most-common clinical diagnoses were Alzheimer’s disease (AD) dementia (20.0%), idiopathic Parkinson’s disease (15.1%), unspecified dementia (11.9%), and cognitively unimpaired (CU) (11.4%).Most cases of unspecified dementia had a pathological diagnosis of central nervous system (CNS) vasculopathy (31.8%) or AD (31.8%). Remarkably, only 14.2% of CU cases had normal pathological findings. The three-most-common pathological diagnoses were AD (26.5%), CNS vasculopathy (14.1%), and Lewy body disease (13.5%).
Conclusions
These clinical and neuropathological findings provide a deeper understanding of the mechanisms underlying NDD in South Korea.
9.Effect of Occlusal and Margin Design on the Fracture Load of Zirconia-Lithium Disilicate Bi-layered Posterior Crowns: An in Vitro Study
Sung-Hoon KIM ; Kyung-Ho KO ; Chan-Jin PARK ; Lee-Ra CHO ; Yoon-Hyuk HUH
Journal of Korean Dental Science 2025;18(1):1-11
Purpose:
The opacity of zirconia sometimes requires a veneering material; thus lithium disilicate, a veneer material with excellent strength, can be used. This study investigated the fracture resistance of zirconia–lithium disilicate (Zr-LS2) bi-layered crowns according to the design of the substructure.
Materials and Methods:
Five groups of posterior Zr-LS2 restorations (Zirtooth and Amber LiSi-POZ) were fabricated with different zirconia substructure coverage (control group, groups half occlusal zirconia coverage; 1/2OZ, and three-quarter occlusal zirconia coverage; 3/4OZ) and margin designs (control group, groups collar margin; C-M, and collarless margin; Cl-M). All restorations were cemented with self-adhesive resin cement followed by 24-h water storage and thermocycling (10,000 cycles, 5°C and 55°C). The fracture load was measured, and failure mode analysis, fractography, and elemental analysis were performed. The one-way analysis of variance and Fisher’s exact test were performed for statistical analyses (α=.05).
Results:
A significant difference was found in the fracture load of Zr-LS2 restorations according to the zirconia coverage of the occlusal area and margin design (P<.05). Group 3/4OZ was significantly larger than the control group C and 1/2OZ (P<.05). The C-M group had greater fracture loads based on margin design than the control group C and Cl-M (P<.05).
Conclusion
The fracture resistance of posterior Zr-LS2 restorations increased with the zirconia coverage, occlusal thickness, and collar margin.
10.Prospective clinical comparative evaluation of implant-supported zirconia-lithium disilicate bilayered ceramic and metalceramic posterior prostheses: a 3-year follow-up
Hye-Seon LEE ; Kyung-Ho KO ; Chan-Jin PARK ; Lee-Ra CHO ; Yoon-Hyuk HUH
The Journal of Advanced Prosthodontics 2025;17(2):59-69
PURPOSE:
The aim of this study was to evaluate the clinical performance and survival rate of implant-supported zirconia-lithium disilicate (Zr-LiSi) bilayered ceramic prostheses over 3 years.
MATERIALS AND METHODS:
This study included 71 patients, including 34 with implant-supported metal-ceramic prostheses (control group) and 37 with implant-supported Zr-LiSi bilayered ceramic prostheses (test group). The implant survival rate and incidence of prosthetic and biological complications (veneer fractures, dislodgement of screw-access hole filling material, screw loosening, peri-implant mucositis and peri-implantitis, and marginal bone loss) were investigated. The survival rate was analyzed using Kaplan-Meier survival curves, and the identity between two groups was confirmed by the log-rank test.
RESULTS:
Both groups showed a 100% survival rate, whereas the prosthetic survival rates were 77% and 73% for the metal-ceramic and Zr-LiSi groups, respectively. Biological complications did not appear in the metal-ceramic group, and 16.2% of peri-implant mucositis occurred in the Zr-LiSi group, which was significant (P < .05). Prosthetic complications occurred in 5.8% of the metal-ceramic group with veneer fractures and did not occur in the Zr-LiSi bilayered ceramic group.
CONCLUSION
This study revealed that posterior Zr-LiSi bilayered ceramic implant prostheses showed high survival rates and similar survival rates to metal-ceramic implant prostheses; however, additional consideration should be given to avoid overcontouring. Zr-LiSi bilayered ceramic implant prostheses may be an option for posterior implant-supported prosthetic treatment.

Result Analysis
Print
Save
E-mail