1.Effects of dental implant surface treated with sandblasting large grit acid-etching and femtosecond laser on implant stability, marginal bone volume, and histological results in a rabbit model
Young-Tak SON ; KeunBaDa SON ; Hoseong CHO ; Jae-Mok LEE ; Sm Abu SALEAH ; JunHo HWANG ; JongHoon LEE ; HyunDeok KIM ; Myoung-Uk JIN ; Jeehyun KIM ; Mansik JEON ; Kyu-Bok LEE
The Journal of Advanced Prosthodontics 2025;17(2):101-114
PURPOSE:
The purpose of this study was to compare the surface characteristics and healing patterns after implantation of implants treated with SLA and those treated with both SLA and femtosecond laser.
MATERIALS AND METHODS:
A total of 10 male New Zealand white rabbits were used to compare recovery levels between implants treated with SLA (SLA group) and those treated with both SLA and femtosecond laser (SF group). The implants’ surface characteristics were determined through topographic evaluation, element analysis, surface roughness, and wettability evaluation. In total, 4 implants were placed in each rabbit (2 in each tibia), with 20 implants per treatment group. Using the implant stability quotient (ISQ), marginal bone volume, and histological analysis (bone-to-implant contact (BIC), bone volume/tissue volume (BV/TV)), and post implantation outcomes were assessed. Outcome data were analyzed using independent t-tests, Mann-Whitney U tests, Wilcoxon signed-rank tests, and one-way ANOVA (α = 0.05).
RESULTS:
No significant differences were noted between SLA and SF groups in terms of ISQ, marginal bone volume, BIC, and BV/TV (P > .05). However, significant differences in ISQ were observed within each group over time (P < .05). Furthermore, significant differences were noted in the marginal bone volume of the SF group (P < .05) and the BV/TV of the SLA group between weeks 4 and 6 (P < .05).
CONCLUSION
Surface treatment via SLA and femtosecond laser is feasible compared with SLA treatment alone in terms of ISQ, marginal bone volume, BIC, and BV/TV. However, further clinical research is warranted.
2.Comparison of interference from eccentric movements of dental crowns fabricated via dynamic jaw motion tracking and conventional methods: a double-blind clinical study
Myung Hyun PARK ; Keunbada SON ; Myoung-Uk JIN ; So-Yeun KIM ; Kyu-Bok LEE
The Journal of Advanced Prosthodontics 2025;17(1):36-46
PURPOSE:
The purpose of this clinical study was to evaluate the extent of intraoral occlusal adjustment required for zirconia crowns designed with a dynamic jaw motion tracking method compared to a conventional approach.
MATERIALS AND METHODS:
Fifteen patients needing zirconia crown restorations in the anterior or posterior regions participated in this study. Following tooth preparation, dynamic jaw motion tracking records were gathered using a tracking device. These records were imported into computer-aided design software and aligned with scanned upper and lower jaw data to design each crown's occlusal surface. Two crowns were fabricated for each patient: one using motion tracking data and another without it. Crowns were scanned pre- and post-adjustment following standard protocols. The scanned data were analyzed with 3D inspection software to calculate occlusal adjustments in the segmented occlusal area as root mean square values, with a paired t-test used for statistical analysis (α = 0.05).
RESULTS:
Crowns designed with motion tracking data required significantly less intraoral occlusal adjustment than those designed conventionally (P = .028).
CONCLUSION
Dynamic jaw motion tracking in crown design reduces the extent of intraoral occlusal adjustment, potentially enhancing clinical efficiency.
3.Low-Density Lipoprotein Cholesterol Level, the Lower the Better? Analysis of Korean Patients in the Treat Stroke to Target Trial
Hanim KWON ; Jae-Chan RYU ; Jae-Kwan CHA ; Sang Min SUNG ; Tae-Jin SONG ; Kyung Bok LEE ; Eung-Gyu KIM ; Yong-Won KIM ; Ji Hoe HEO ; Man Seok PARK ; Kyusik KANG ; Byung-Chul LEE ; Keun-Sik HONG ; Oh Young BANG ; Jei KIM ; Jong S. KIM
Journal of Stroke 2025;27(2):228-236
Background:
and Purpose The Treat Stroke to Target (TST) was a randomized clinical trial involving French and Korean patients demonstrating that a lower low-density lipoprotein cholesterol (LDL-C, <70 mg/dL) target group (LT) experienced fewer cerebro-cardiovascular events than a higher target (90–110 mg/dL) group (HT). However, whether these results can be applied to Asian patients with different ischemic stroke subtypes remains unclear.
Methods:
Patients from 14 South Korean centers were analyzed separately. Patients with ischemic stroke or transient ischemic attack with evidence of atherosclerosis were randomized into LT and HT groups. The primary endpoint was a composite of ischemic stroke, myocardial infarction, coronary or cerebral revascularization, and cardiovascular death.
Results:
Among 712 enrolled patients, the mean LDL-C level was 71.0 mg/dL in 357 LT patients and 86.1 mg/dL in 355 HT patients. The primary endpoint occurred in 24 (6.7%) of LT and in 31 (8.7%) of HT group patients (adjusted hazard ratio [HR]=0.78; 95% confidence interval [CI]=0.45–1.33, P=0.353). Cardiovascular events alone occurred significantly less frequently in the LT than in the HT group (HR 0.26, 95% CI 0.09–0.80, P=0.019), whereas there were no significant differences in ischemic stroke events (HR 1.12, 95% CI 0.60–2.10, P=0.712). The benefit of LT was less apparent in patients with small vessel disease and intracranial atherosclerosis than in those with extracranial atherosclerosis.
Conclusion
In contrast to the French TST, the outcomes in Korean patients were neutral. Although LT was more effective in preventing cardiovascular diseases, it was not so in stroke prevention, probably attributed to the differences in stroke subtypes. Further studies are needed to elucidate the efficacy of statins and appropriate LDL-C targets in Asian patients with stroke.
4.Effects of dental implant surface treated with sandblasting large grit acid-etching and femtosecond laser on implant stability, marginal bone volume, and histological results in a rabbit model
Young-Tak SON ; KeunBaDa SON ; Hoseong CHO ; Jae-Mok LEE ; Sm Abu SALEAH ; JunHo HWANG ; JongHoon LEE ; HyunDeok KIM ; Myoung-Uk JIN ; Jeehyun KIM ; Mansik JEON ; Kyu-Bok LEE
The Journal of Advanced Prosthodontics 2025;17(2):101-114
PURPOSE:
The purpose of this study was to compare the surface characteristics and healing patterns after implantation of implants treated with SLA and those treated with both SLA and femtosecond laser.
MATERIALS AND METHODS:
A total of 10 male New Zealand white rabbits were used to compare recovery levels between implants treated with SLA (SLA group) and those treated with both SLA and femtosecond laser (SF group). The implants’ surface characteristics were determined through topographic evaluation, element analysis, surface roughness, and wettability evaluation. In total, 4 implants were placed in each rabbit (2 in each tibia), with 20 implants per treatment group. Using the implant stability quotient (ISQ), marginal bone volume, and histological analysis (bone-to-implant contact (BIC), bone volume/tissue volume (BV/TV)), and post implantation outcomes were assessed. Outcome data were analyzed using independent t-tests, Mann-Whitney U tests, Wilcoxon signed-rank tests, and one-way ANOVA (α = 0.05).
RESULTS:
No significant differences were noted between SLA and SF groups in terms of ISQ, marginal bone volume, BIC, and BV/TV (P > .05). However, significant differences in ISQ were observed within each group over time (P < .05). Furthermore, significant differences were noted in the marginal bone volume of the SF group (P < .05) and the BV/TV of the SLA group between weeks 4 and 6 (P < .05).
CONCLUSION
Surface treatment via SLA and femtosecond laser is feasible compared with SLA treatment alone in terms of ISQ, marginal bone volume, BIC, and BV/TV. However, further clinical research is warranted.
5.Comparison of interference from eccentric movements of dental crowns fabricated via dynamic jaw motion tracking and conventional methods: a double-blind clinical study
Myung Hyun PARK ; Keunbada SON ; Myoung-Uk JIN ; So-Yeun KIM ; Kyu-Bok LEE
The Journal of Advanced Prosthodontics 2025;17(1):36-46
PURPOSE:
The purpose of this clinical study was to evaluate the extent of intraoral occlusal adjustment required for zirconia crowns designed with a dynamic jaw motion tracking method compared to a conventional approach.
MATERIALS AND METHODS:
Fifteen patients needing zirconia crown restorations in the anterior or posterior regions participated in this study. Following tooth preparation, dynamic jaw motion tracking records were gathered using a tracking device. These records were imported into computer-aided design software and aligned with scanned upper and lower jaw data to design each crown's occlusal surface. Two crowns were fabricated for each patient: one using motion tracking data and another without it. Crowns were scanned pre- and post-adjustment following standard protocols. The scanned data were analyzed with 3D inspection software to calculate occlusal adjustments in the segmented occlusal area as root mean square values, with a paired t-test used for statistical analysis (α = 0.05).
RESULTS:
Crowns designed with motion tracking data required significantly less intraoral occlusal adjustment than those designed conventionally (P = .028).
CONCLUSION
Dynamic jaw motion tracking in crown design reduces the extent of intraoral occlusal adjustment, potentially enhancing clinical efficiency.
6.Effects of dental implant surface treated with sandblasting large grit acid-etching and femtosecond laser on implant stability, marginal bone volume, and histological results in a rabbit model
Young-Tak SON ; KeunBaDa SON ; Hoseong CHO ; Jae-Mok LEE ; Sm Abu SALEAH ; JunHo HWANG ; JongHoon LEE ; HyunDeok KIM ; Myoung-Uk JIN ; Jeehyun KIM ; Mansik JEON ; Kyu-Bok LEE
The Journal of Advanced Prosthodontics 2025;17(2):101-114
PURPOSE:
The purpose of this study was to compare the surface characteristics and healing patterns after implantation of implants treated with SLA and those treated with both SLA and femtosecond laser.
MATERIALS AND METHODS:
A total of 10 male New Zealand white rabbits were used to compare recovery levels between implants treated with SLA (SLA group) and those treated with both SLA and femtosecond laser (SF group). The implants’ surface characteristics were determined through topographic evaluation, element analysis, surface roughness, and wettability evaluation. In total, 4 implants were placed in each rabbit (2 in each tibia), with 20 implants per treatment group. Using the implant stability quotient (ISQ), marginal bone volume, and histological analysis (bone-to-implant contact (BIC), bone volume/tissue volume (BV/TV)), and post implantation outcomes were assessed. Outcome data were analyzed using independent t-tests, Mann-Whitney U tests, Wilcoxon signed-rank tests, and one-way ANOVA (α = 0.05).
RESULTS:
No significant differences were noted between SLA and SF groups in terms of ISQ, marginal bone volume, BIC, and BV/TV (P > .05). However, significant differences in ISQ were observed within each group over time (P < .05). Furthermore, significant differences were noted in the marginal bone volume of the SF group (P < .05) and the BV/TV of the SLA group between weeks 4 and 6 (P < .05).
CONCLUSION
Surface treatment via SLA and femtosecond laser is feasible compared with SLA treatment alone in terms of ISQ, marginal bone volume, BIC, and BV/TV. However, further clinical research is warranted.
7.Comparison of interference from eccentric movements of dental crowns fabricated via dynamic jaw motion tracking and conventional methods: a double-blind clinical study
Myung Hyun PARK ; Keunbada SON ; Myoung-Uk JIN ; So-Yeun KIM ; Kyu-Bok LEE
The Journal of Advanced Prosthodontics 2025;17(1):36-46
PURPOSE:
The purpose of this clinical study was to evaluate the extent of intraoral occlusal adjustment required for zirconia crowns designed with a dynamic jaw motion tracking method compared to a conventional approach.
MATERIALS AND METHODS:
Fifteen patients needing zirconia crown restorations in the anterior or posterior regions participated in this study. Following tooth preparation, dynamic jaw motion tracking records were gathered using a tracking device. These records were imported into computer-aided design software and aligned with scanned upper and lower jaw data to design each crown's occlusal surface. Two crowns were fabricated for each patient: one using motion tracking data and another without it. Crowns were scanned pre- and post-adjustment following standard protocols. The scanned data were analyzed with 3D inspection software to calculate occlusal adjustments in the segmented occlusal area as root mean square values, with a paired t-test used for statistical analysis (α = 0.05).
RESULTS:
Crowns designed with motion tracking data required significantly less intraoral occlusal adjustment than those designed conventionally (P = .028).
CONCLUSION
Dynamic jaw motion tracking in crown design reduces the extent of intraoral occlusal adjustment, potentially enhancing clinical efficiency.
8.Effects of dental implant surface treated with sandblasting large grit acid-etching and femtosecond laser on implant stability, marginal bone volume, and histological results in a rabbit model
Young-Tak SON ; KeunBaDa SON ; Hoseong CHO ; Jae-Mok LEE ; Sm Abu SALEAH ; JunHo HWANG ; JongHoon LEE ; HyunDeok KIM ; Myoung-Uk JIN ; Jeehyun KIM ; Mansik JEON ; Kyu-Bok LEE
The Journal of Advanced Prosthodontics 2025;17(2):101-114
PURPOSE:
The purpose of this study was to compare the surface characteristics and healing patterns after implantation of implants treated with SLA and those treated with both SLA and femtosecond laser.
MATERIALS AND METHODS:
A total of 10 male New Zealand white rabbits were used to compare recovery levels between implants treated with SLA (SLA group) and those treated with both SLA and femtosecond laser (SF group). The implants’ surface characteristics were determined through topographic evaluation, element analysis, surface roughness, and wettability evaluation. In total, 4 implants were placed in each rabbit (2 in each tibia), with 20 implants per treatment group. Using the implant stability quotient (ISQ), marginal bone volume, and histological analysis (bone-to-implant contact (BIC), bone volume/tissue volume (BV/TV)), and post implantation outcomes were assessed. Outcome data were analyzed using independent t-tests, Mann-Whitney U tests, Wilcoxon signed-rank tests, and one-way ANOVA (α = 0.05).
RESULTS:
No significant differences were noted between SLA and SF groups in terms of ISQ, marginal bone volume, BIC, and BV/TV (P > .05). However, significant differences in ISQ were observed within each group over time (P < .05). Furthermore, significant differences were noted in the marginal bone volume of the SF group (P < .05) and the BV/TV of the SLA group between weeks 4 and 6 (P < .05).
CONCLUSION
Surface treatment via SLA and femtosecond laser is feasible compared with SLA treatment alone in terms of ISQ, marginal bone volume, BIC, and BV/TV. However, further clinical research is warranted.
9.Comparison of interference from eccentric movements of dental crowns fabricated via dynamic jaw motion tracking and conventional methods: a double-blind clinical study
Myung Hyun PARK ; Keunbada SON ; Myoung-Uk JIN ; So-Yeun KIM ; Kyu-Bok LEE
The Journal of Advanced Prosthodontics 2025;17(1):36-46
PURPOSE:
The purpose of this clinical study was to evaluate the extent of intraoral occlusal adjustment required for zirconia crowns designed with a dynamic jaw motion tracking method compared to a conventional approach.
MATERIALS AND METHODS:
Fifteen patients needing zirconia crown restorations in the anterior or posterior regions participated in this study. Following tooth preparation, dynamic jaw motion tracking records were gathered using a tracking device. These records were imported into computer-aided design software and aligned with scanned upper and lower jaw data to design each crown's occlusal surface. Two crowns were fabricated for each patient: one using motion tracking data and another without it. Crowns were scanned pre- and post-adjustment following standard protocols. The scanned data were analyzed with 3D inspection software to calculate occlusal adjustments in the segmented occlusal area as root mean square values, with a paired t-test used for statistical analysis (α = 0.05).
RESULTS:
Crowns designed with motion tracking data required significantly less intraoral occlusal adjustment than those designed conventionally (P = .028).
CONCLUSION
Dynamic jaw motion tracking in crown design reduces the extent of intraoral occlusal adjustment, potentially enhancing clinical efficiency.
10.Low-Density Lipoprotein Cholesterol Level, the Lower the Better? Analysis of Korean Patients in the Treat Stroke to Target Trial
Hanim KWON ; Jae-Chan RYU ; Jae-Kwan CHA ; Sang Min SUNG ; Tae-Jin SONG ; Kyung Bok LEE ; Eung-Gyu KIM ; Yong-Won KIM ; Ji Hoe HEO ; Man Seok PARK ; Kyusik KANG ; Byung-Chul LEE ; Keun-Sik HONG ; Oh Young BANG ; Jei KIM ; Jong S. KIM
Journal of Stroke 2025;27(2):228-236
Background:
and Purpose The Treat Stroke to Target (TST) was a randomized clinical trial involving French and Korean patients demonstrating that a lower low-density lipoprotein cholesterol (LDL-C, <70 mg/dL) target group (LT) experienced fewer cerebro-cardiovascular events than a higher target (90–110 mg/dL) group (HT). However, whether these results can be applied to Asian patients with different ischemic stroke subtypes remains unclear.
Methods:
Patients from 14 South Korean centers were analyzed separately. Patients with ischemic stroke or transient ischemic attack with evidence of atherosclerosis were randomized into LT and HT groups. The primary endpoint was a composite of ischemic stroke, myocardial infarction, coronary or cerebral revascularization, and cardiovascular death.
Results:
Among 712 enrolled patients, the mean LDL-C level was 71.0 mg/dL in 357 LT patients and 86.1 mg/dL in 355 HT patients. The primary endpoint occurred in 24 (6.7%) of LT and in 31 (8.7%) of HT group patients (adjusted hazard ratio [HR]=0.78; 95% confidence interval [CI]=0.45–1.33, P=0.353). Cardiovascular events alone occurred significantly less frequently in the LT than in the HT group (HR 0.26, 95% CI 0.09–0.80, P=0.019), whereas there were no significant differences in ischemic stroke events (HR 1.12, 95% CI 0.60–2.10, P=0.712). The benefit of LT was less apparent in patients with small vessel disease and intracranial atherosclerosis than in those with extracranial atherosclerosis.
Conclusion
In contrast to the French TST, the outcomes in Korean patients were neutral. Although LT was more effective in preventing cardiovascular diseases, it was not so in stroke prevention, probably attributed to the differences in stroke subtypes. Further studies are needed to elucidate the efficacy of statins and appropriate LDL-C targets in Asian patients with stroke.

Result Analysis
Print
Save
E-mail