1.Doxorubicin-Induced Cardiotoxicity at Non-Cumulative Dose in a Dog with Multicentric Lymphoma
Jihyeon GO ; Seha AHN ; Seongwon HEO ; Seulgi HWANG ; Hayoung RYU ; Jinyoung PARK ; Chaewon SHIN ; Dong-In JUNG ; DoHyeon YU ; Hyeona BAE
Journal of Veterinary Clinics 2025;42(4):190-195
Doxorubicin is an effective chemotherapeutic agent widely used in veterinary oncology, particularly as part of the CHOP protocol for canine lymphoma. Despite its therapeutic benefit, cardiotoxicity remains a serious dose-limiting adverse effect. Although clinically significant cardiotoxicity is typically reported at cumulative doses of 150-240 mg/m 2 in dogs, functional cardiac deterioration has been observed at lower doses, with progression to congestive heart failure rarely reported. This case report describes doxorubicin-induced cardiotoxicity below the established cumulative threshold in a dog with multicentric lymphoma, which presented with overt clinical signs of congestive heart failure, including coughing, syncope, and pleural effusion. The dog also exhibited marked echocardiographic changes, including right atrial enlargement and a reduction in fractional shortening from 33% to 21% over 2 weeks, ultimately resulting in death 53 days after symptom onset. The clinical diagnosis was supported by the temporal relationship with doxorubicin administration and serial cardiac imaging findings. This case highlights that severe cardiotoxicity can occur even below traditionally accepted cumulative thresholds, reinforcing the importance of individualized, ongoing cardiac monitoring and early intervention, regardless of dose.
2.Study of the removal difference in indoor particulate matter and volatile organic compounds through the application of plants.
Seung Han HONG ; Jiyeon HONG ; Jihyeon YU ; Youngwook LIM
Environmental Health and Toxicology 2017;32(1):e2017006-
This study was conducted to evaluate the ability of plants to purify indoor air by observing the effective reduction rate among pollutant types of particulate matter (PM) and volatile organic compounds (VOCs). PM and four types of VOCs were measured in a new building that is less than three years old and under three different conditions: before applying the plant, after applying the plant, and a room without a plant. The removal rate of each pollutant type due to the plant was also compared and analyzed. In the case of indoor PM, the removal effect was negligible because of outdoor influence. However, 9% of benzene, 75% of ethylbenzene, 72% of xylene, 75% of styrene, 50% of formaldehyde, 36% of acetaldehyde, 35% of acrolein with acetone, and 85% of toluene were reduced. The purification of indoor air by natural ventilation is meaningless because the ambient PM concentration has recently been high. However, contamination by gaseous materials such as VOCs can effectively be removed through the application of plants.
Acetaldehyde
;
Acetone
;
Acrolein
;
Benzene
;
Formaldehyde
;
Particulate Matter*
;
Plants
;
Styrene
;
Toluene
;
Ventilation
;
Volatile Organic Compounds*
;
Xylenes
3.Study of the removal difference in indoor particulate matter and volatile organic compounds through the application of plants
Seung Han HONG ; Jiyeon HONG ; Jihyeon YU ; Youngwook LIM
Environmental Health and Toxicology 2017;32(1):2017006-
This study was conducted to evaluate the ability of plants to purify indoor air by observing the effective reduction rate among pollutant types of particulate matter (PM) and volatile organic compounds (VOCs). PM and four types of VOCs were measured in a new building that is less than three years old and under three different conditions: before applying the plant, after applying the plant, and a room without a plant. The removal rate of each pollutant type due to the plant was also compared and analyzed. In the case of indoor PM, the removal effect was negligible because of outdoor influence. However, 9% of benzene, 75% of ethylbenzene, 72% of xylene, 75% of styrene, 50% of formaldehyde, 36% of acetaldehyde, 35% of acrolein with acetone, and 85% of toluene were reduced. The purification of indoor air by natural ventilation is meaningless because the ambient PM concentration has recently been high. However, contamination by gaseous materials such as VOCs can effectively be removed through the application of plants.
Acetaldehyde
;
Acetone
;
Acrolein
;
Benzene
;
Formaldehyde
;
Particulate Matter
;
Plants
;
Styrene
;
Toluene
;
Ventilation
;
Volatile Organic Compounds
;
Xylenes

Result Analysis
Print
Save
E-mail