1.Mosquito monitoring and influence of meteorological factors on mosquito density around Beijing Capital International Airport, 2016-2022
Ran FENG ; Tie-zheng MA ; Si-jie ZHU ; Bo TIAN ; Fei QUAN ; Zhi-lin WU ; Xiao-tao LIU ; Fu-yuan ZHANG ; Song-jian ZHANG
Acta Parasitologica et Medica Entomologica Sinica 2026;33(1):40-48
Objective To understand mosquito density, species composition, and seasonal variations around the Beijing Capital International Airport(BCIA)and provide scientific evidence for mosquito-borne disease prevention and control. Methods Meteorological data were collected from 2016 to 2022, and mosquito density was monitored at seven surveillance sites around the BCIA from May to October each year using CO2-baited mosquito traps to analyze the relationship between mosquito density and meteorological factors. Results In total,68 518 female mosquitoes were captured, with a mosquito density of 10.20 per light · hour. The dominant species was Culex pipiens pallens(73.90%), followed by Aedes albopictus(9.71%)and Ae. vexans(9.29%);the mosquito density was highest in 2016(14.8 per light·hour)and lowest in 2022(4.46 per light·hour). Significant statistical differences were observed in mosquito density among different species(F=18.118, P<0.05). The density of Cx. pipiens pallens and other mosquito species showed a mutually exclusive trend; the peak of mosquito density varied based on years and habitats, with significant statistical differences in mosquito density among different habitats(F=8.504, P<0.05). The highest mosquito density was observed near the Wenyu River(21.50 per light·hour), whereas the lowest was recorded at the BCIA construction site(2.44 per light· hour). The monthly average temperature(r=0.595), monthly average highest temperature(r=0.575), and monthly average lowest temperature(r=0.624)showed moderate positive correlations, whereas the monthly average air pressure(r=-0.484)showed a moderate negative correlation. The monthly average minimum temperature was included in the regression model(F=25.575, P<0.000), and the equation Y=1.029X4-8.181 was used. The monthly average air pressure 2 months prior(b=-2.418, β=-1.619, P<0.05)and the monthly average relative humidity(b=-0.739, β=-1.201, P<0.05)significantly negatively predicted the mosquito density. Notably, the regression equation used was y=2526.170+(-2.418)X9+(-0.739)X13. The exposure-response analysis revealed that the density of mosquitoes was not linearly related to the average monthly air pressure, rainfall, and duration of sunshine. Conclusions The dominant mosquito species around the BCIA was Cx. pipiens pallens, Ae. albopictus, and Ae. vexans. During the control of Cx. pipiens pallens, the impact on other mosquito species must also be considered. Environmental management, breeding sites, and scientific use of pesticides should be prioritized based on the activity periods of mosquitoes. Further studies on mosquitoes and meteorological factors should be conducted to provide references and novel avenues for mosquito control.
2.Discriminating Tumor Deposits From Metastatic Lymph Nodes in Rectal Cancer: A Pilot Study Utilizing Dynamic Contrast-Enhanced MRI
Xue-han WU ; Yu-tao QUE ; Xin-yue YANG ; Zi-qiang WEN ; Yu-ru MA ; Zhi-wen ZHANG ; Quan-meng LIU ; Wen-jie FAN ; Li DING ; Yue-jiao LANG ; Yun-zhu WU ; Jian-peng YUAN ; Shen-ping YU ; Yi-yan LIU ; Yan CHEN
Korean Journal of Radiology 2025;26(5):400-410
Objective:
To evaluate the feasibility of dynamic contrast-enhanced MRI (DCE-MRI) in differentiating tumor deposits (TDs) from metastatic lymph nodes (MLNs) in rectal cancer.
Materials and Methods:
A retrospective analysis was conducted on 70 patients with rectal cancer, including 168 lesions (70 TDs and 98 MLNs confirmed by histopathology), who underwent pretreatment MRI and subsequent surgery between March 2019 and December 2022. The morphological characteristics of TDs and MLNs, along with quantitative parameters derived from DCE-MRI (K trans , kep, and v e) and DWI (ADCmin, ADCmax, and ADCmean), were analyzed and compared between the two groups.Multivariable binary logistic regression and receiver operating characteristic (ROC) curve analyses were performed to assess the diagnostic performance of significant individual quantitative parameters and combined parameters in distinguishing TDs from MLNs.
Results:
All morphological features, including size, shape, border, and signal intensity, as well as all DCE-MRI parameters showed significant differences between TDs and MLNs (all P < 0.05). However, ADC values did not demonstrate significant differences (all P > 0.05). Among the single quantitative parameters, v e had the highest diagnostic accuracy, with an area under the ROC curve (AUC) of 0.772 for distinguishing TDs from MLNs. A multivariable logistic regression model incorporating short axis, border, v e, and ADC mean improved diagnostic performance, achieving an AUC of 0.833 (P = 0.027).
Conclusion
The combination of morphological features, DCE-MRI parameters, and ADC values can effectively aid in the preoperative differentiation of TDs from MLNs in rectal cancer.
3.Discriminating Tumor Deposits From Metastatic Lymph Nodes in Rectal Cancer: A Pilot Study Utilizing Dynamic Contrast-Enhanced MRI
Xue-han WU ; Yu-tao QUE ; Xin-yue YANG ; Zi-qiang WEN ; Yu-ru MA ; Zhi-wen ZHANG ; Quan-meng LIU ; Wen-jie FAN ; Li DING ; Yue-jiao LANG ; Yun-zhu WU ; Jian-peng YUAN ; Shen-ping YU ; Yi-yan LIU ; Yan CHEN
Korean Journal of Radiology 2025;26(5):400-410
Objective:
To evaluate the feasibility of dynamic contrast-enhanced MRI (DCE-MRI) in differentiating tumor deposits (TDs) from metastatic lymph nodes (MLNs) in rectal cancer.
Materials and Methods:
A retrospective analysis was conducted on 70 patients with rectal cancer, including 168 lesions (70 TDs and 98 MLNs confirmed by histopathology), who underwent pretreatment MRI and subsequent surgery between March 2019 and December 2022. The morphological characteristics of TDs and MLNs, along with quantitative parameters derived from DCE-MRI (K trans , kep, and v e) and DWI (ADCmin, ADCmax, and ADCmean), were analyzed and compared between the two groups.Multivariable binary logistic regression and receiver operating characteristic (ROC) curve analyses were performed to assess the diagnostic performance of significant individual quantitative parameters and combined parameters in distinguishing TDs from MLNs.
Results:
All morphological features, including size, shape, border, and signal intensity, as well as all DCE-MRI parameters showed significant differences between TDs and MLNs (all P < 0.05). However, ADC values did not demonstrate significant differences (all P > 0.05). Among the single quantitative parameters, v e had the highest diagnostic accuracy, with an area under the ROC curve (AUC) of 0.772 for distinguishing TDs from MLNs. A multivariable logistic regression model incorporating short axis, border, v e, and ADC mean improved diagnostic performance, achieving an AUC of 0.833 (P = 0.027).
Conclusion
The combination of morphological features, DCE-MRI parameters, and ADC values can effectively aid in the preoperative differentiation of TDs from MLNs in rectal cancer.
4.Discriminating Tumor Deposits From Metastatic Lymph Nodes in Rectal Cancer: A Pilot Study Utilizing Dynamic Contrast-Enhanced MRI
Xue-han WU ; Yu-tao QUE ; Xin-yue YANG ; Zi-qiang WEN ; Yu-ru MA ; Zhi-wen ZHANG ; Quan-meng LIU ; Wen-jie FAN ; Li DING ; Yue-jiao LANG ; Yun-zhu WU ; Jian-peng YUAN ; Shen-ping YU ; Yi-yan LIU ; Yan CHEN
Korean Journal of Radiology 2025;26(5):400-410
Objective:
To evaluate the feasibility of dynamic contrast-enhanced MRI (DCE-MRI) in differentiating tumor deposits (TDs) from metastatic lymph nodes (MLNs) in rectal cancer.
Materials and Methods:
A retrospective analysis was conducted on 70 patients with rectal cancer, including 168 lesions (70 TDs and 98 MLNs confirmed by histopathology), who underwent pretreatment MRI and subsequent surgery between March 2019 and December 2022. The morphological characteristics of TDs and MLNs, along with quantitative parameters derived from DCE-MRI (K trans , kep, and v e) and DWI (ADCmin, ADCmax, and ADCmean), were analyzed and compared between the two groups.Multivariable binary logistic regression and receiver operating characteristic (ROC) curve analyses were performed to assess the diagnostic performance of significant individual quantitative parameters and combined parameters in distinguishing TDs from MLNs.
Results:
All morphological features, including size, shape, border, and signal intensity, as well as all DCE-MRI parameters showed significant differences between TDs and MLNs (all P < 0.05). However, ADC values did not demonstrate significant differences (all P > 0.05). Among the single quantitative parameters, v e had the highest diagnostic accuracy, with an area under the ROC curve (AUC) of 0.772 for distinguishing TDs from MLNs. A multivariable logistic regression model incorporating short axis, border, v e, and ADC mean improved diagnostic performance, achieving an AUC of 0.833 (P = 0.027).
Conclusion
The combination of morphological features, DCE-MRI parameters, and ADC values can effectively aid in the preoperative differentiation of TDs from MLNs in rectal cancer.
5.A Pneumatic Micro-valve with Sandwich Structure Based on Micro-electro-mechanical System
Shao-Jie MA ; Wen-Bo LI ; Yu-Chen ZHU ; Zhi-Rui LI ; Bin ZHAO ; Fei FENG
Chinese Journal of Analytical Chemistry 2025;53(5):758-764
In this study,an ON/OFF type micro-valve with a sandwich(glass-silicon-glass)structure was designed and fabricated based on the micro-electro-mechanical system(MEMS)technique.The deformable membrane of this micro-valve was prepared on the silicon on insulator(SOI)substrate and sealed using Si-Si bonding and anodic bonding methods.The micro-valve had high-temperature stability and was suitable for integration with other gas chromatography components.The deformable membrane with a thickness of 10 μm was processed on the top silicon of the SOI substrate.The flow control of the micro-valve could be achieved by changing the driving pressure applied to the deformable membrane to deform it.Compared with polymer membranes,the deformable membrane prepared on the top layer silicon of SOI had better temperature stability and could be released using the deep reactive ion etching technique after silicon-silicon bonding,avoiding deformation during the preparation process.In addition,due to the small gap between the membrane and the inlet/outlet holes,the dead volume of the microvalve was very small.The test results indicated that the micro-valve achieved flow control and ON/OFF functions with good repeatability.
6.A Monolithic Integrated Gas Chromatography Chip with Gas Chromatographic Column and Helium Discharge Ionization Detector
Yu-Chen ZHU ; Shao-Jie MA ; Wen-Bo LI ; Zhi-Rui LI ; Bin ZHAO ; Fei FENG
Chinese Journal of Analytical Chemistry 2025;53(7):1064-1071
A monolithic integrated gas chromatography chip,consisting of a micro gas chromatography column(μGCC)and a micro helium discharge ionization detector(μHDID)was proposed.The chip was fabricated using micro electromechanical system(MEMS)technique,and its sensitivity was improved from two aspects.On one hand,open tubular column was selected as the separation device,and the auxiliary helium channel width of μHDID was modulated based on the microchannel width of the μGCC to match the flow rates of μHDID and μGCC.On the other hand,the electrode structure inside the μHDID collection zone was optimized,a bias electrode group around the collection electrode was constructed,and the ion collection efficiency was improved.After coating HKUST-1 as the stationary phase,the monolithic integrated gas chromatography chip could achieve baseline separation and detection of light hydrocarbon gas mixture(methane,ethane,propane,andn-butane),with a detection limit for propane as low as 25 pg.The chip could carried out test under temperature-programmed conditions,with a resolution of 9.24 for ethane and propane.
7.A Micro Gas Chromatographic Column with Large Surface Area Based on Anodization
Shao-Jie MA ; Wen-Bo LI ; Yu-Chen ZHU ; Bo-Xin CHEN ; Zhi-Rui LI ; Bin ZHAO ; Fei FENG
Chinese Journal of Analytical Chemistry 2025;53(10):1607-1614
A micro gas chromatographic column with mesoporous surface micro column array prepared by anodization method was proposed.A porous support layer with a characteristic pore size of about 30 nm inside the chromatographic column was prepared in situ using anodization method,and a uniform alumina stationary phase was deposited on the mesoporous support layer using atom layer deposition(ALD)technique.The existence of a mesoporous support layer increased surface area of the chromatographic column,thereby increasing the total amount of stationary phase loading and enhancing column capacity,which facilitated chromatographic separation.The test results showed that the porous support layer significantly reduced the longitudinal molecular diffusion and mass transfer resistance of the micro gas chromatographic column,and significantly increased the number of theoretical plates(n-nonane increased by 290.2%).Furthermore,column efficiency of the chromatographic column was less affected by flow rate,which was conducive to rapid separation of heavy hydrocarbon mixtures.
8.Creation and Exploration of the"Organized Fill-in-the-Blank Format"Disci-pline Construction Model for Forensic Medicine in the New Era
Zhi-Wen WEI ; Hong-Xing WANG ; Jun-Hong SUN ; Hao-Liang FAN ; Hong-Liang SU ; Le-Le WANG ; Wen-Ting HE ; Zhe CHEN ; Jie ZHANG ; Xiang-Jie GUO ; Ji LI ; Geng-Qian ZHANG ; Xin-Hua LIANG ; Jiang-Wei YAN ; Qiang-Qiang ZHANG ; Cai-Rong GAO ; Ying-Yuan WANG ; Hong-Wei WANG ; Jun XIE ; Bo-Feng ZHU ; Ke-Ming YUN
Journal of Forensic Medicine 2025;41(1):25-29
Forensic medicine has been designated as a first-level discipline,presenting new opportunities and challenges for the development of forensic medicine.Since the 1980s,the establishment of foren-sic medicine discipline and the cultivation of high-level forensic talents have become hot topics in the development of forensic medicine in China.Since the 13th Five-Year Plan,the forensic team of Shanxi Medical University has been aiming at the forefront,proposing the development goals of"Five First-class"and the discipline development path"Six Major Achievements".It has selected benchmark disci-plines,identified gaps in disciplinary development,unified thoughts,formulated completion timelines,concentrated superior resources,assigned tasks to individuals,and created an"Organized Fill-in-the-Blank Format"forensic medicine discipline construction model with the characteristics of the new era.The construction model of forensic medicine has achieved good results in the goals,discipline frame-work,scientific research,talent cultivation,discipline team and platform construction,forming a rela-tively complete discipline construction and management system,and accumulating valuable experience for the construction of first-level discipline and high-level talent cultivation of forensic medicine.
9.Mechanism by which sanguis draconis flavones regulating ROS/TXNIP pathway-mediated pyroptosis to ameliorate cerebral ischemia-reperfusion injury in rats
Chao-Xia ZHU ; Zhi-Ying LI ; Xiao-Fei LÜ ; Qian ZHAO ; Bao-Cang CHENG ; Hui-Jie YANG ; Li-Ping ZHOU ; Li-Min ZENG
Acta Anatomica Sinica 2025;56(6):673-680
Objective To explore the mechanism by which the sanguis draconis flavones(SDF)regulates the reactive oxygen species(ROS)/thioredoxin-interacting protein(TXNIP)pathway to mediate cell pyroptosis and improve cerebral ischemia-reperfusion injury(CIRI)in rats.Methods The experimental rats were randomly divided into the control group(Ctrl),the CIRI group,the low-dose SDF group(SDF-L),the high-dose SDF group(SDF-H),and the SDF-H+ROS/TXNIP pathway activator,trimethylamine oxide(TMAO)group(SDF-H+TMAO).Among them,except for the control group,the remaining rats all needed to establish the CIRI rat model by the modified suture method.Zea Longa scoring was performed on rats from each group.ELISA was used to detect the levels of serum inflammatory factors interleukin(IL)-1β,IL-18 and oxidative stress-related factors superoxide dismutase(SOD),malondialdehyde(MDA),glutathione peroxidase(GSH-Px).Flow cytometry was used to measure the ROS levels.Cerebral edema was detected.Cerebral infarction was detected by 2,3,5-triphenyl tetrazolium chloride(TTC)staining.HE staining was used to detect the pathological changes of brain tissue.Immunohistochemistry was used to detect the expression of pyrolytic effector protein dermolin D(GSDMD).Western blotting was used to detect the expression of proteins related to the ROS/TXNIP pathway.Results Compared with the control group,a large area of cerebral infarctions were observed in the brain tissue of the CIRI group,accompanied by mild hemorrhage and obvious infiltration of inflammatory cells.Neuronal cells underwent degeneration and necrosis,with sparse and disordered arrangement.The phenomena of nuclear condensation and nucleolus lysis were obvious.The Zea Longa score,cerebral infarction volume,brain tissue water content,levels of IL-1β,IL-18,ROS,MDA,and the expressions of GSDMD,TXNIP,nucleotide-binding oligomerization domain-like receptor protein 3(NLRP3),apoptosis-related punctate protein(ASC),and Caspase-1 increased,while the activities of SOD and GSH-Px decreased(P<0.05).Compared with the CIRI group,the pathological damage of brain tissues in the SDF-L group and the SDF-H group was significantly improved.The Zea Longa score,cerebral infarction volume,brain tissue water content,levels of IL-1β,IL-18,ROS,MDA,and the expressions of GSDMD,TXNIP,NLRP3,ASC,and Caspase-1 decreased.The activities of SOD and GSH-Px increased(P<0.05);TMAO treatment partially reversed the improvement effect of SDF on CIRI in rats.Conclusion SDF ameliorates cerebral CIRI in rats by inhibiting ROS/TXNIP pathway-mediated pyroptosis.
10.Discriminating Tumor Deposits From Metastatic Lymph Nodes in Rectal Cancer: A Pilot Study Utilizing Dynamic Contrast-Enhanced MRI
Xue-han WU ; Yu-tao QUE ; Xin-yue YANG ; Zi-qiang WEN ; Yu-ru MA ; Zhi-wen ZHANG ; Quan-meng LIU ; Wen-jie FAN ; Li DING ; Yue-jiao LANG ; Yun-zhu WU ; Jian-peng YUAN ; Shen-ping YU ; Yi-yan LIU ; Yan CHEN
Korean Journal of Radiology 2025;26(5):400-410
Objective:
To evaluate the feasibility of dynamic contrast-enhanced MRI (DCE-MRI) in differentiating tumor deposits (TDs) from metastatic lymph nodes (MLNs) in rectal cancer.
Materials and Methods:
A retrospective analysis was conducted on 70 patients with rectal cancer, including 168 lesions (70 TDs and 98 MLNs confirmed by histopathology), who underwent pretreatment MRI and subsequent surgery between March 2019 and December 2022. The morphological characteristics of TDs and MLNs, along with quantitative parameters derived from DCE-MRI (K trans , kep, and v e) and DWI (ADCmin, ADCmax, and ADCmean), were analyzed and compared between the two groups.Multivariable binary logistic regression and receiver operating characteristic (ROC) curve analyses were performed to assess the diagnostic performance of significant individual quantitative parameters and combined parameters in distinguishing TDs from MLNs.
Results:
All morphological features, including size, shape, border, and signal intensity, as well as all DCE-MRI parameters showed significant differences between TDs and MLNs (all P < 0.05). However, ADC values did not demonstrate significant differences (all P > 0.05). Among the single quantitative parameters, v e had the highest diagnostic accuracy, with an area under the ROC curve (AUC) of 0.772 for distinguishing TDs from MLNs. A multivariable logistic regression model incorporating short axis, border, v e, and ADC mean improved diagnostic performance, achieving an AUC of 0.833 (P = 0.027).
Conclusion
The combination of morphological features, DCE-MRI parameters, and ADC values can effectively aid in the preoperative differentiation of TDs from MLNs in rectal cancer.


Result Analysis
Print
Save
E-mail