1.Comparison on prognosis of hepatocellular carcinoma patients with hepatitis B and hepatitis C after microwave ablation
Luo WANG ; Jie YU ; Yanchun LUO ; Xiaoling YU ; Jing ZHANG ; Zhigang CHENG ; Zhiyu HAN ; Fangyi LIU ; Ping LIANG
Chinese Journal of Interventional Imaging and Therapy 2024;21(5):262-267
Objective To comparatively explore the prognosis of hepatocellular carcinoma(HCC)patients with hepatitis B(HB)and hepatitis C(HC)after microwave ablation(MWA).Methods Data of 159 HCC patients with HB(HB-HCC)and 159 HCC patients with HC(HC-HCC)who received MWA treatment were retrospectively collected.The oncologic outcomes were compared between groups,the causes of death were analyzed,and the risk factors of overall survival(OS)in HCC patients after MWA were observed.Results The OS rate in HC-HCC group was lower than that in HB-HCC group(P=0.045),while no significant difference of disease free survival rate(P=0.095)nor cancer specific survival rate(P=0.180)was found between groups.Compared with HB-HCC group,HC-HCC group had higher risk of death due to complications related to liver cirrhosis(HR=2.339,P=0.043).Child-Pugh class B(HR=3.082,P<0.001),hepatitis viral load>500 IU/ml(HR=1.654,P=0.006)and the maximum diameter of lesion≥3.0 cm(HR=1.541,P=0.017)were all independent risk factors of OS in HCC patients after MWA.Conclusion Compared with HB-HCC patients,HC-HCC patients had shorter OS after MWA.
2.Comparison of scope of nurse practice in different countries
Yu ZHANG ; Jie CHEN ; Xiaojie WANG ; Jialu ZHANG ; Meng ZHANG ; Xiaoying LIANG ; Tianyi WANG ; Haixin BO
Chinese Journal of Modern Nursing 2024;30(16):2212-2217
Objective:To compare the policies and literature on scope of nurse practice in various countries, so as to provide reference for optimizing the expansion of scope of nurse practice in China.Methods:Literature on nurse practice was systematically searched on PubMed, Web of Science, China National Knowledge Infrastructure, WanFang Data, and nursing policy organization websites in various countries. The search period was from database establishment to June 2023.Results:A total of 19 articles from six countries were included. There were elements such as registration types and requirements, practice methods, prescription authority, supervision departments, and relevant laws. The inspiration for the hierarchical management of nurses in China mainly included four aspects: improving the hierarchical registration and management system, clarifying the job responsibilities of nurses; guiding the reasonable flow of nursing talents, encouraging multi-site practice in nurses; cultivating nurses' prescription ability and granting them prescription authority; improving supervision and legal protection to ensure that nurses practiced in accordance with the law.Conclusions:It is urgent to expand the practice scope of the nursing team in our country, supplement grassroots medical and health talents, undertake the functions of case management for chronic patients, improve the quality of life of patients, and meet the important task of community and family nursing needs.
3.Experimental study on evaluating renal redox metabolism in renal ischemia-reperfusion injury using GluCEST imaging with 3.0 T MRI
Wenxia MI ; Zhaoyu XING ; Liang PAN ; Xintian YU ; Jie CHEN ; Wei XING
Chinese Journal of Internal Medicine 2024;63(6):593-599
Objective:To investigate the feasibility of 3.0 T glutamate chemical exchange saturation transfer (GluCEST) imaging in evaluating renal redox metabolism in renal ischemia-reperfusion injury (IRI).Methods:Rabbits in the IRI group ( n=56) underwent surgery by clamping the left renal artery for 45 min and then releasing to establish IRI. Rabbits in the sham group ( n=8) underwent the same operation without clamping the left renal artery. GluCEST MRI was performed before and at 1 h, 12 h, 1 day, 3 days, 7 days, and 14 days after the operations, with eight rabbits in the IRI group sacrificed immediately after each scanning and eight in the sham group sacrificed at 14 days after scanning. The left kidneys were removed for histopathological examination and reactive oxygen species (ROS) fluorescence staining. Differences in the magnetic resonance ratio asymmetry (MTR asym) of the renal cortex and outer medulla among different groups were compared. Correlations between the MTR asym and ROS were analyzed. Results:The MTR asym of the renal cortex in the sham and IRI subgroups were higher than that of the outer medulla ( t=8.16, P<0.001; t=4.78, P=0.002; t=4.94, P=0.002; t=5.76, P=0.001, t=6.68, P<0.001; t=6.40, P<0.001; t=5.16, P=0.001; t=3.30, P=0.013). The MTR asym of the renal cortex and outer medulla in the IRI-1h, IRI-12h, IRI-1d, IRI-3d, IRI-7d, and IRI-14d groups were lower than in the sham and IRI-pre groups (all P<0.05). The MTR asym of the renal cortex and outer medulla in the IRI-1h group were lower than in the IRI-12h, IRI-1d, IRI-3d, IRI-7d, and IRI-14d groups (all P<0.05). The MTR asym of the renal cortex in the IRI-12h group was lower than in the IRI-7d and IRI-14d groups (1.84%±0.09% vs.2.42%±0.19%, 2.41%±0.31%, all P<0.05). The MTR asym of the renal cortex in the IRI-1d group was lower than in the IRI-7d group (1.99%±0.17% vs. 2.42%±0.19%, P=0.008). The MTR asym of the outer medulla in the IRI-12h group was lower than in the IRI-3d, IRI-7d, and IRI-14d groups (1.32%±0.27% vs. 1.79%±0.31%, 1.98%±0.18%, 1.66%±0.40%, respectively, all P<0.05]. The MTR asym of the outer medulla in the IRI-7d group was higher than in the IRI-1d and IRI-14d groups (1.98%±0.18% vs. 1.52%±0.31%, 1.66%±0.40%, all P<0.05). The MTR asym of the renal cortex and outer medulla had a strong negative correlation with the mean fluorescence intensity of ROS ( ρ=-0.889, P<0.001; ρ=-0.784, P<0.001). Conclusion:3.0 T GluCEST imaging can indirectly reflect the changes of renal redox metabolism in renal IRI.
4.Effects of Shenxiao Jiedu Tongluo Recipe on AIM2-mediated pyroptosis of renal cells in a golden hamster model of diabetic nephropathy
Yu-Peng XIAO ; Ying-Jun DING ; Bao-Zhu DING ; Shu-Jie HOU ; Si-Yang LIU ; Zi-Wei ZHANG ; Xiao-Xia LI ; Wen-Jie LIANG ; Nan ZHANG
Chinese Traditional Patent Medicine 2024;46(11):3603-3612
AIM To investigate the effects and mechanism of Shenxiao Jiedu Tongluo Recipe on renal AIM 2-mediated pyroptosis of a golden hamster model of diabetic nephropathy(DN).METHODS Fifty male golden hamsters of SPF grade were randomly divided into the control group and the model group.The golden hamsters of the model group successfully developed into DN models by feeding of high glucose and high fat diet and intraperitoneal injection of STZ were further randomly assigned into the model group,the enagliflozin group(10 mg/kg),and the low-dose and the high-dose Shenxiao Jiedu Tongluo Recipe groups(12.8,25.6 g/kg)for 8 weeks gavage of the corresponding administration.The golden hamsters had their levels of fasting blood glucose,24 h-UTP,serum TC,LDL-C,Scr,and Sur detected by automatic biochemical analyzer;their serum SOD activity and MDA level detected by biochemical method;their serum levels of IL-1β,IL-18,and TNF-α detected by ELISA method;their pathomorphological changes of kidney tissue observed by HE and PAS staining;their protein expressions of ROS and γH2AX detected by immunofluorescence or immunohistochemistry;and their renal protein expressions of AIM 2,caspase-1 and GSDMD detected by Western blot and immunohistochemistry.RESULTS Compared with the control group,the model group showed atrophic glomeruli;enlarged glomerular capsule cavity;mesangial expansion;edema and necrosis in the dilated renal tubules;increased levels of fasting blood glucose,24 h-UTP,serum TC,LDL-C,Scr,Sur,IL-1β,IL-18,TNF-α,MDA and renal protein expressions of ROS,γH2AX,AIM2,caspase-1,GSDMD(P<0.01);and decreased serum SOD activity(P<0.01).Compared with the model group,the high-dose Shenxiao Jiedu Tongluo Recipe group and the enagliflozin group displayed improved renal histopathology,decreased levels of 24 h-UTP,serum TC,LDL-C,Scr,Sur,IL-1β,IL-18,TNF-α,MDA and renal protein expressions of ROS,γH2AX,AIM2,caspase-1,GSDMD(P<0.05,P<0.01);and increased serum SOD activity(P<0.01).CONCLUSION Shenxiao Jiedu Tongluo Recipe can inhibit AIM 2-mediated cell death and alleviate renal inflammatory damage in golden hamsters by inhibiting their expression of ROS-dsDNA-AIM 2 signal pathway to attain reduction of their renal ROS level,DNA damage of renal intrinsic cells,and synthesis of AIM 2 inflammatory corpuscles as well.
5.Effect of lining restoration in reconstruction of nasal defects
Huichuan DUAN ; Xiaoping ZHOU ; Dong LI ; Sizheng ZHOU ; Liang XU ; Zheyuan YU ; Min WEI ; Jie YUAN
Chinese Journal of Medical Aesthetics and Cosmetology 2024;30(4):316-319
Objective:To investigate the clinical outcomes of lining repair during the reconstruction of nasal defects.Methods:From January 2010 to December 2022, our team treated 15 nasal defect patients aged between 18 and 62 years with an average age of 38, including 8 males and 7 females. The range of the defect was more than one subunit in all cases. And forehead pedicled flaps were chosen for repair. For nasal reconstruction, expander was implanted to expand the central forehead flap. The choice of support depended on the range of the defect, including rib-rib cartilage composite grafts, rib cartilage grafts and ear cartilage grafts. The repair of the lining was selected with the original skin, local nasolabial flapor forehead pedicled flap to repair the mucosal defect of the nose. Postoperative follow-up was conducted to observe the effects.Results:Among the 15 patients, 8 cases underwent rib-rib cartilage composite grafts. 3 cases had rib cartilage grafts, and 4 cases had ear cartilage grafts. All the flaps survived with 1 case experiencing infection. Postoperative follow-up for 0.5 to 2 years showed that the appearance of nasal defects in all 15 cases was significantly improved, with satisfactory results.Conclusions:The repair of nasal defect lining requires a comprehensive analysis based on the specific location, range of the defect, and the selection of the donor area in order to ultimately determine the surgical approach.
6.Current status and prospects of exoskeletons applied in medical service support
Yao-Rui YU ; Xue-Jun HU ; Kun-Peng WU ; Jing-Guang PAN ; Huo-Liang CHEN ; Jie REN ; Wei JIANG
Chinese Medical Equipment Journal 2024;45(3):71-75
The current status of exoskeletons was introduced in enhancing individual soldier's battlefield rescue capabilities,promoting the integrated use of battlefield rescue equipment,protecting medical personnel on the battlefield and assisting injured soldiers in rehabilitation training.The challenges of exoskeletons faced in human-machine interaction,power supply endurance,heavy overall structure,restricted movement and high cost were analyzed when applied to medical service support,and some suggestions were proposed accordingly including enhancing technology research and development,integrated application,communication and cooperation and personnel training.References were provided for the application of exoskeletons in China's medical service support.[Chinese Medical Equipment Journal,2024,45(3):71-75]
7.Design of dilation incision device for neurosurgical procedures
Yu-Wei HAN ; Li-Gang CHEN ; Xin-Yu YANG ; Shun GONG ; Guo-Biao LIANG ; Hai JIN ; Jie-Yu LAI
Chinese Medical Equipment Journal 2024;45(10):37-40
Objective To design and evaluate a dilation incision device capable of facilitating stable support and flexible adjustment during neurosurgical procedures.Methods The dilation incision device was composed of a support plate,an adjustment assembly,a brain support ring,a rotation assembly,an electric motor,an expansion assembly and a neck support ring.The support plate was made of high-strength stainless steel;the adjustment assembly was made up of a first screw,a lifting groove,a slide bar and a nut;the brain support ring was fixed to the adjustment assembly through a support rod,with an outer layer of medical-grade silicone and an inner layer of stainless steel skeleton;the rotation assembly connected the brain support ring with the expansion assembly and consisted of a rotating shaft,a connecting rod and a rotating lug;a high-precision direct current servo motor was selected for the device;the expansion assembly included a spring,an expansion plate and a moving plate,which realized auto expansion or contraction through spring pressure;the neck support ring had its outer layer made of flexible polyurethane foam and inner layer being a stainless steel skeleton.The device had its stability and safety evaluated by static and dynamic tests at different heights(50,100,150 mm)and angles(0°,30°,60°),which was compared with the traditional fixation device to verify its application effect.Results Static and dynamic tests indicated the device showed high stability and safety in different heights and angles,and gained advantages over the traditional device in stability,convenient operation and surgical field visualization.Conclusion The device developed meets the requirements of neurosurgical procedures,and enhances the safety and portability of neurosurgical procedures.[Chinese Medical Equipment Journal,2024,45(10):37-40]
8.Spatial distribution pattern of local tumor progression analysis after microwave ablation of hepatocellular carcinoma based on three-dimensional magnetic resonance imaging
Fangying FAN ; Wenzhen DING ; Fangyi LIU ; Zhigang CHENG ; Zhiyu HAN ; Xiaoling YU ; Ping LIANG ; Jie YU
Chinese Journal of Hepatology 2024;32(3):208-213
Objective:To investigate the spatial distribution pattern of local tumor progression (LTP) for hepatocellular carcinoma (HCC) ≤5 cm after microwave ablation.Methods:A retrospective analysis was performed on 169 HCCs with matched MRI before and after ablation from December 2009 to December 2019. A tumor MRI was reconstructed using three-dimensional visualization technology. LTP was classified as contact or non-contact, early or late stage, according to whether LTP was in contact with the edge of the ablation zone and the occurrence time (24 months). The tumor-surrounded area was divided into eight quadrants by using the eight-quadrant map method. An analysis was conducted on the spatial correlation between the quadrant where the ablative margin (AM) safety boundary was located and the quadrant where different types of LTP occurred. The t-test, or rank-sum test, was used for the measurement data. 2-test for count data was used to compare the difference between the two groups.Results:The AM quadrant had a distribution of 54.4% LTP, 64.2% early LTP stage, and 69.1% contact LTP, suggesting this quadrant was much more concentrated than the other quadrants ( P ?0.001). Additionally, the AM quadrant had only 15.2% of non-contact type LTP and 17.1% of late LTP, which was not significantly different from the average distribution probability of 12.5% (100/8%) among the eight quadrants ( P = 0.667, 0.743). 46.6% of early contact type LTP was located at the ablation needle tip, 25.2% at the body, and 28.1% at the caudal, while the location distribution probabilities of non-early contact LTP were 34.8%, 31.8%, and 33.3%, respectively. Conclusion:LTP mostly occurs in areas where the ablation safety boundary is the shortest. However, non-contact LTP and late LTP stages exhibit the feature of uniform distribution. Thus, this type of LPT may result from an inadequate non-ablation safety boundary.
9.Curative effect of percutaneous microwave ablation therapy on hepatocellular carcinoma survival: a 15-year real-world study
Yanchun LUO ; Manlin LANG ; Wenjia CAI ; Zhiyu HAN ; Fangyi LIU ; Zhigang CHENG ; Xiaoling YU ; Jianping DOU ; Xin LI ; Shuilian TAN ; Xuejuan DONG ; Ping LIANG ; Jie YU
Chinese Journal of Hepatology 2024;32(4):332-339
Objective:To evaluate the long-term efficacy of percutaneous microwave ablation (MWA) therapy for hepatocellular carcinoma.Methods:2054 cases with Barcelona Clinic Liver Cancer (BCLC) stage 0~B at the Fifth Medical Center of the Chinese People's Liberation Army General Hospital from January 2006 to September 2020 were retrospectively collected. All patients were followed up for at least 2 years. The primary endpoint of overall survival and secondary endpoints (tumor-related survival, disease-free survival, and postoperative complications) of patients treated with ultrasound-guided percutaneous MWA were analyzed. Kaplan-Meier method was used for stratified survival rate analysis. Fine-and-Gray competing risk model was used to analyze overall survival.Results:A total of 5 503 HCC nodules [mean tumor diameter (2.6±1.6) cm] underwent 3 908 MWAs between January 2006 and September 2020, with a median follow-up time of 45.6 (24.0 -79.2) months.The technical effectiveness rate of 5 375 tumor nodules was 97.5%. The overall survival rates at 5, 10, and 15-years were 61.6%, 38.8%, and 27.0%, respectively. The tumor-specific survival rates were 67.1%, 47.2%, and 37.7%, respectively. The free tumor survival rates were 25.8%, 15.7%, and 9.9%, respectively. The incidence rate of severe complications was 2.8% (108/3 908). Further analysis showed that the technical effectiveness and survival rate over the passing three time periods from January 2006-2010, 2011-2015, and 2016-September 2020 were significantly increased, with P ?0.001, especially for liver cancer 3.1~5.0 cm ( P ?0.001). Conclusion:Microwave ablation therapy is a safe and effective method for BCLC stage 0-B, with significantly enhanced technical efficacy and survival rate over time.
10.Comparison on image quality of 5.0T and 3.0T time of flight MR angiography for displaying anterior choroidal arteries
Zhangzhu LI ; Liang YIN ; Mingyan SHANG ; Zhensong WANG ; Dan YU ; Jie GAN
Chinese Journal of Medical Imaging Technology 2024;40(5):653-656
Objective To compare image quality of 5.0T and 3.0T time of flight MR angiography(TOF-MRA)and displaying choroidal anterior arteries(AChA).Methods Data of 80 patients who underwent head 5.0T(5.0T group,n=40)and/or 3.0T TOF-MRA(3.0T group,n=42)were retrospectively analyzed,among them 2 patients underwent both 5.0T and 3.0T TOF-MRA.The subjective scoring and objective evaluation of image quality were performed,and the results were compared between groups.AChA was divided into proximal,intermediate and distal segments(A1,A2,A3 segment),the quantity of left and right AChA shown on 5.0T and 3.0T TOF-MRA were recorded,and the length and diameter of left and right AChA dispalyed on MRA were comparatively observed.Results The subjective scores of image quality of 5.0T group were higher than that of 3.0T group(5.0[4.0,5.0]vs.5.0[3.0,5.0],Z=6.417,P=0.029).The signal-to-noise ratio(91.01±5.04)and contrast-to-noise ratio(72.47±5.14)of 5.0T group were both larger than those of 3.0T group([62.11±4.16],[48.92±4.62],t=28.339,19.681,both P<0.001).There were 80 segments of AChA-A1,80 of AChA-A2 and 60 segments of AChA-A3 displayed on 5.0T TOF-MRA,while 60 segments of AChA-A1,36 of AChA-A2 and 12 segments of AChA-A3 displayed on 3.0T TOF-MRA,respectively.In 5.0T group,the length of the left and right AChA was(24.01±7.41)mm and(22.72±9.36)mm,with diameter of(1.16±0.12)mm and(1.19±0.14)mm,respectively,whereas in 3.0T group,the relative values were(18.35±8.67)mm,(16.80±6.94)mm,(0.99±0.25)mm and(0.95±0.29)mm,respectively,all in 5.0T group were greater than in 3.0T group(t=3.242,3.183,4.595,3.846,all P<0.001).Conclusion Compared with 3.0T TOF-MRA,5.0T TOF-MRA of AChA might provide better image quality and clearer vessel depiction,being helpful to clinical diagnosis and treatment of ACHA-related cerebral vascular diseases.

Result Analysis
Print
Save
E-mail