1.Roles and mechanisms of TRIM family proteins in the regulation of bone metabolism.
Jing YANG ; Rui-Qi HUANG ; Ke XU ; Mian-Mian YANG ; Xue-Jie YI ; Bo CHANG ; Ting-Ting YAO
Acta Physiologica Sinica 2025;77(3):472-482
Tripartite motif-containing (TRIM) family proteins are crucial E3 ubiquitin ligases that have garnered significant attention for their regulatory roles in bone metabolism in recent years. This article reviews the function and regulatory mechanisms of TRIM family proteins in bone metabolism, focusing on their dual roles in bone formation and resorption. It also provides a detailed analysis of signaling pathways and molecular mechanisms by which TRIM family members regulate the activities of osteoblasts and osteoclasts. Research findings suggest that modulating the expression or activity of TRIM family proteins could be beneficial for treating bone diseases such as osteoporosis. This review highlights the molecular mechanisms of TRIM family members in bone physiology and pathology, aiming to provide theoretical basis and scientific guidance for developing novel therapeutic strategies for bone diseases.
Humans
;
Ubiquitin-Protein Ligases/physiology*
;
Bone and Bones/metabolism*
;
Animals
;
Tripartite Motif Proteins/physiology*
;
Osteoclasts/metabolism*
;
Osteoblasts/metabolism*
;
Signal Transduction/physiology*
;
Osteogenesis/physiology*
2.A convenient research strategy for functional verification of epigenetic regulators during spermatogenesis.
Shan LI ; Ying YUAN ; Ke-Yu ZHANG ; Yi-Dan GUO ; Lu-Tong WANG ; Xiao-Yuan ZHANG ; Shu ZHANG ; Qi YAN ; Rong ZHANG ; Jie CHEN ; Feng-Tang YANG ; Jing-Rui LI
Asian Journal of Andrology 2025;27(2):261-267
Spermatogenesis is a fundamental process that requires a tightly controlled epigenetic event in spermatogonial stem cells (SSCs). The mechanisms underlying the transition from SSCs to sperm are largely unknown. Most studies utilize gene knockout mice to explain the mechanisms. However, the production of genetically engineered mice is costly and time-consuming. In this study, we presented a convenient research strategy using an RNA interference (RNAi) and testicular transplantation approach. Histone H3 lysine 9 (H3K9) methylation was dynamically regulated during spermatogenesis. As Jumonji domain-containing protein 1A (JMJD1A) and Jumonji domain-containing protein 2C (JMJD2C) demethylases catalyze histone H3 lysine 9 dimethylation (H3K9me2), we firstly analyzed the expression profile of the two demethylases and then investigated their function. Using the convenient research strategy, we showed that normal spermatogenesis is disrupted due to the downregulated expression of both demethylases. These results suggest that this strategy might be a simple and alternative approach for analyzing spermatogenesis relative to the gene knockout mice strategy.
Spermatogenesis/physiology*
;
Animals
;
Male
;
Mice
;
Epigenesis, Genetic
;
Jumonji Domain-Containing Histone Demethylases/metabolism*
;
Histones/metabolism*
;
RNA Interference
;
Testis/metabolism*
;
Methylation
;
Mice, Knockout
;
Histone Demethylases
3.SAE1 promotes tumor cell malignancy via SUMOylation and liquid-liquid phase separation facilitated nuclear export of p27.
Ling WANG ; Jie MIN ; Jinjun QIAN ; Xiaofang HUANG ; Xichao YU ; Yuhao CAO ; Shanliang SUN ; Mengying KE ; Xinyu LV ; Wenfeng SU ; Mengjie GUO ; Nianguang LI ; Shiqian QI ; Hongming HUANG ; Chunyan GU ; Ye YANG
Acta Pharmaceutica Sinica B 2025;15(4):1991-2007
Most cancers are currently incurable, partly due to abnormal post-translational modifications (PTMs). In this study, we initially used multiple myeloma (MM) as a working model and found that SUMOylation activating enzyme subunit 1 (SAE1) promotes the malignancy of MM. Through proteome microarray analysis, SAE1 was identified as a potential target for bioactive colcemid or its derivative colchicine. Elevated levels of SAE1 were associated with poor clinical survival and increased MM proliferation in vitro and in vivo. Additionally, SAE1 directly SUMOylated and upregulated the total protein expression of p27, leading to LLPS-mediated nuclear export of p27. Our study also demonstrated the involvement of SAE1 in other types of cancer cells, and provided the first monomer crystal structure of SAE1 and its key binding model with colchicine. Colchicine also showed promising results in the Patient-Derived Tumor Xenograft (PDX) model. Furthermore, a controlled clinical trial with 56 MM patients demonstrated the clinical efficacy of colchicine. Our findings reveal a novel mechanism by which tumor cells evade p27-induced cellular growth arrest through p27 SUMOylation-mediated nuclear export. SAE1 may serve as a promising therapeutic target, and colchicine may be a potential treatment option for multiple types of cancer in clinical settings.
4.Photon-counting detector CT with virtual monoenergetic imaging in enabling a quadruple low-dose aortic CT angiography protocol: a feasibility study
Ke QI ; Kehui NIE ; Dian YUAN ; Yicun ZHANG ; Mengyuan ZHANG ; Weiting ZHANG ; Yanbo GU ; Yan CHEN ; Jianbo GAO ; Jie LIU
Chinese Journal of Radiology 2025;59(10):1133-1141
Objective:To assess the viability of reducing radiation dose, contrast media volume, injection flow rate and contrast medium concentration (quadruple low-dose protocol) by utilizing virtual monoenergetic images (VMI) in photon-counting detector CT (PCD-CT) for aortic CT angiography (CTA), while maintaining image quality in comparison to images obtained from energy-integrating detector CT (EID-CT).Methods:From April 2024 to June 2024, a total of 40 participants who underwent aortic CTA on PCD-CT were prospectively enrolled in the experimental group (PCD-CT group), while 40 patients with similar baseline characteristics who had previously undergone aortic CTA using EID-CT were retrospectively selected for the conventional group (EID-CT group). The EID-CT group used a tube voltage of 90 kVp, a contrast media volume of 60 ml of contrast, an injection flow rate of 3 ml/s, and a contrast concentration of 350 mgI/ml; the PCD-CT group used the QuantumPlus mode, with a tube voltage of 140 kVp, a total amount of iodine in the contrast media of 140 mgI/kg, and an injection flow rate=contrast media volume/(delay time+scan time), and a contrast media concentration of 320 mgI/ml. VMIs in PCD-CT group were reconstructed in 5-keV intervals ranging from 45 to 65 keV. The effective radiation dose and contrast injection protocols were recorded and compared between two groups. Objective image quality assessment was performed for each group. CT attenuation, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were measured at five anatomical locations (ascending aorta, aortic arch, descending aorta, abdominal aorta, and right common iliac artery), and image noise was recorded. Subjective image quality was independently evaluated by two readers using a 5-point Likert scale in a blinded manner. Based on data normality, the one-way ANOVA or Kruskal-Wallis test was used for image quality assessment, with Bonferroni-corrected post-hoc analysis for multiple comparisons.Results:There were no significant differences in the baseline characteristics between two groups (all P0.05). The PCD-CT group demonstrated significantly lower effective radiation dose [(3.88±0.65) mSv vs. (5.97±1.15)mSv], contrast media volume [(29.25±4.56) ml vs. 60 ml], and injection rate [(2.65±0.42) ml/s vs. 3 ml/s] than the EID-CT group, with reductions of 35%, 51%, and 12%, respectively (all P0.001). For objective image quality, except for the ascending aortic CT attenuation, the CT attenuation, SNR, and CNR of other vessels in the 55 keV PCD-CT group were comparable to those in the EID-CT group. Additionally, the difference in image noise between these two groups was not statistically significant ( P0.05). Concerning subjective image quality, at 55 keV, the PCD-CT group had similar image noise scores and vessel attenuation scores (both P0.05) and better visualization of renal artery branching ( P=0.001) compared to the EID-CT group. Conclusion:In comparison to EID-CT, the use of a 55 keV image in PCD-CT for aortic CTA has demonstrated reductions in radiation dose, contrast media volume, injection flow rate and contrast medium concentration, while maintaining image quality.
5.Feasibility study of photon counting CT combined with “quadruple lows” technology in head and neck vascular imaging
Mengyuan ZHANG ; Kehui NIE ; Dian YUAN ; Yicun ZHANG ; Ke QI ; Weiting ZHANG ; Yanbo GU ; Yan CHEN ; Jianbo GAO ; Jie LIU
Chinese Journal of Radiology 2025;59(8):942-948
Objective:To evaluate the feasibility of head and neck vascular imaging using photon-counting detector computed tomography (PCD-CT) combined with a “quadruple lows” protocol—characterized by low contrast media volume, low iodine concentration, low injection rate, and low radiation dose—and to compare the image quality with that obtained by energy-integrating detector CT (EID-CT).Methods:A total of 105 patients with suspected cerebrovascular disease were prospectively enrolled at the First Affiliated Hospital of Zhengzhou University between April and June 2024. Patients were randomly assigned to three groups ( n=35). Group A underwent conventional head and neck CTA using EID-CT. Group B underwent PCD-CT with a protocol involving ultra-low contrast media volume, low iodine concentration, and low injection rate. Group C underwent PCD-CT with the full “quadruple low” protocol. Objective image quality parameters—including CT attenuation, image noise (standard deviation, SD), signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR)—were measured at the ascending aorta, common carotid artery, internal carotid artery, vertebral artery, basilar artery, posterior cerebral artery, and middle cerebral artery. Two radiologists independently rated subjective image quality using a 5-point Likert scale. Differences among groups were analyzed using one-way ANOVA and the Kruskal-Wallis test. Results:Compared to Group A [contrast volume: (42.78±6.64)ml], contrast agent volume was significantly reduced in Groups B and C[ (26.26±4.45) ml and (26.54±3.83)ml, respectively], demonstrating reductions of 39% and 38% (both P<0.01). The iodine concentration was 320 mg/ml in Groups B and C, lower than 350 mg/ml in Group A (8.5%). The injection rate was also reduced in Groups B and C [(3.39±0.61) and (3.55±0.51)ml/s, respectively] compared to Group A [(4.28±0.66) ml/s], with reductions of 21% and 17% (both P<0.01). The effective dose (ED) was similar between Groups A and B [(1.40±0.15) vs. (1.40±0.19)mSv, P>0.05], while Group C demonstrated a significantly lower ED [(0.99±0.09) mSv], with a reduction of 30% compared to Group A and 29% compared to Group B (both P<0.01).In terms of objective image quality, significant differences in image noise (SD) were observed among the three groups at the vertebral artery, internal carotid artery, posterior cerebral artery, and middle cerebral artery (all P<0.05). Groups B and C showed significantly lower SD compared to Group A ( P<0.05), with no significant difference between B and C ( P>0.05). SNR was significantly higher in Groups B and C than in Group A at multiple vascular segments (all P<0.05). CNR differed only at the internal carotid artery, where Groups B and C demonstrated superior performance compared to Group A ( P<0.05).Subjective image quality scores showed no significant difference between Groups A and C ( P>0.05), while Group B had significantly higher scores than both A and C ( P<0.05). All images were deemed diagnostically acceptable. Conclusion:Compared with conventional EID-CT, PCD-CT combined with a “quadruple lows” protocol enables substantial reductions in contrast media and radiation dose while further improving image quality in head and neck CTA.
6.Photon-counting detector-CT combined with"four-lows"protocol for coronary CT angiography
Weiting ZHANG ; Kehui NIE ; Dian YUAN ; Yicun ZHANG ; Ke QI ; Mengyuan ZHANG ; Yanbo GU ; Yan CHEN ; Jianbo GAO ; Yonggao ZHANG ; Jie LIU
Chinese Journal of Medical Imaging Technology 2025;41(6):976-980
Objective To observe the feasibility of photon-counting detector(PCD)-CT combined with"four-lows"protocol(low contrast agent concentration,low contrast dose,low contrast agent flow rate,low radiation dose)for coronary CT angiography(CCTA).Methods Totally 106 patients with suspected coronary artery disease were prospectively enrolled and randomized into energy-integrating detector(EID)-CCTA(group A,using conventional scanning protocol,n=52)or PCD-CCTA(group B,using"four-lows"scanning protocol,n=54)groups and underwent relative examinations.The radiation dose,subjective and objective evaluation results of imaging quality were compared between groups.Results The contrast agent dose and flow rate,volume CT dose index,dose length product and effective dose in group B were all lower than those in group A(all P<0.001).The subjective scores in group B were higher than in group A(5[4,5]vs.4[4,5],Z=-2.310,P=0.021).Compared with group A,CT value,signal-to-noise ratio and contrast-to-noise ratio of aortic root and most of the main branches of coronary arteries increased in group B,while standard deviation of CT value decreased(all P<0.05).Conclusion PCD-CT combined with"four-lows"protocol could be used for CCTA,which could improve imaging quality and reduce contrast agent usage and radiation dose.
7.The Role of NEAT1 in Bone and Cartilage Metabolism and Bone Diseases
Rui-Ming WEN ; Rui-Qi HUANG ; Yi-Xing CHANG ; Ke XU ; Xue-Jie YI
Progress in Biochemistry and Biophysics 2025;52(4):930-945
In the process of maintaining the steady state of bone tissue, the transcription network and signal pathway of the body play a vital role. These complex regulatory mechanisms need precise coordination to ensure the balance between bone formation and bone absorption. Once this balance is broken, it may lead to pathological changes of bone and cartilage, and then lead to various bone diseases. Therefore, it is of great significance to understand these regulatory mechanisms for the prevention and treatment of bone diseases. In recent years, with the deepening of research, more and more lncRNA has been found to be closely related to bone health. Among them, nuclear paraspeckle assembly transcript 1 (NEAT1), as an extremely abundant RNA molecule in mammalian nuclei, has attracted extensive attention. NEAT1 is mainly transcribed from a specific site in human chromosome 11 by RNA polymerase II (RNaseP), which can form two different subtypes NEAT1_1 and NEAT1_2. These two subtypes are different in intracellular distribution and function, but they participate in many biological processes together. Studies have shown that NEAT1 plays a specific role in the process of cell growth and stress response. For example, it can regulate the development of osteoblasts (OB), osteoclasts (OC) and chondrocytes by balancing the differentiation of bone marrow mesenchymal stem cells (BMSCs), thus maintaining the steady state of bone metabolism. This discovery reveals the important role of NEAT1 in bone development and remodeling. In addition, NEAT1 is closely related to a variety of bone diseases. In patients with bone diseases such as osteoporosis (OP), osteoarthritis (OA) and osteosarcoma (OS), the expression level of NEAT1 is different. These differential expressions may be closely related to the pathogenesis and progression of bone diseases. By regulating the level of NEAT1, it can affect a variety of signal transduction pathways, and then affect the development of bone diseases. For example, some studies show that by regulating the expression level of NEAT1, the activity of osteoclasts can be inhibited, and the proliferation and differentiation of osteoblasts can be promoted, thus improving the symptoms of osteoporosis. It is worth noting that NEAT1 can also be used as a key sensor for the prevention and treatment of bone diseases. When exercising or receiving some natural products, the expression level of NEAT1 will change, thus reflecting the response of bones to external stimuli. This feature makes NEAT1 an important target for studying the prevention and treatment strategies of bone diseases. However, although the role of NEAT1 in bone biology and bone diseases has been initially recognized, its specific mechanism and regulatory relationship are still controversial. For example, the expression level, mode of action and interaction with other molecules of NEAT1 in different bone diseases still need further in-depth study. This paper reviews the role of NEAT1 in maintaining bone and cartilage metabolism, and discusses its expression and function in various bone diseases. By combing the existing research results and controversial points, this paper aims to provide new perspectives and ideas for the prevention and treatment of bone diseases, and provide useful reference and enlightenment for future research.
8.Exploring behavioral patterns and hippocampal neurogenesis in autism spectrum disorder mice
Xiao-Jie NIU ; Jiao LIU ; Xin-Wei ZHANG ; Ze-Tao WANG ; Ke-Qi YAN ; Qi-Yuan LIU ; Wan-Yun HAO ; Pei-Jun ZHANG
Acta Anatomica Sinica 2025;56(2):171-179
Objective To explore the behavioral patterns and hippocampal neurogenesis of CHD8+mice,and to provide behavioral and morphological basis for improving autism like behavior and neurogenesis.Methods Genotype of wild type(WT)and CHD8+/-mice was identified.Weight measurement was conducted on both male and female mice of the WT and CHD8+/-strains.Subsequently,a battery of behavioral tests was administered,which included three-chamber test,self-grooming test,nesting test,Y-maze spontaneous alternation test,food burial test,open-field test and light-dark transition test.Afterwards,the mice were administered 2%pentobarbital sodium(2 ml/kg)to induce anesthesia.Their brains were frozen with 4%paraformaldehyde,removed for photography and analysis to identify any alterations in brain size.Western blotting and immunofluorescent labeling were used to detect changes in the process of hippocampus neurogenesis.Results Western blotting analysis demonstrated a decrease in the amounts of chromodomain helicase DNA binding protein 8(CHD8)protein in both male and female mice with CHD8+genotype,as compared to WT mice.There were no notable disparities in body weight between male and female WT and CHD8+mice,as well as in brain size.The three-chamber social behavior test revealed that both male and female CHD8+/-mice had social deficiencies(P<0.05).During the open field test,there was no significant difference in the total distance moved by male and female WT and CHD8+/-mice.However,the amount of time spent in the central region was considerably lower in CHD8+/-mice compared to the WT mice(P<0.01).Furthermore,the light-dark transition test revealed that both male and female CHD8+/-mice spent considerably less time investigating the white box compared to the WT mice(P<0.05).Nevertheless,there were no notable alterations found in self-grooming,nesting,spontaneous alternation of Y-maze,and food burial experiments.In addition,Western blotting result demonstrated a significant drop in doublecortin(DCX)expression(P<0.001),and immunofluorescent staining revealed a notable reduction in the number of DCX+cells(P<0.01)in the hippocampus of CHD8+/-mice.Conclusion CHD8+/-mice exhibit social disorders and anxiety-like behaviors,with a decrease in the number of newly generated neurons in the hippocampus and neurogenesis disorders.
9.Effect of Renshen-Huangjing combination on post-traumatic stress disorder based on bioinformatics and animal experiments and its mechanism
Ke-ke DING ; Dao-kang CHEN ; Jing-ji WANG ; Xun-cui WANG ; Zheng-rong ZHANG ; Shao-jie YANG ; Guo-qi ZHU
Chinese Pharmacological Bulletin 2025;41(6):1099-1107
Aim To evaluate the ameliorative effects of different ratios of Renshen-Huangjing(RH) on SPS-induced PTSD-like behaviors in mice,and to investi-gate the action mechanism using bioinformatics analysis and experimental studies.Methods The aqueous ex-tract was extracted in four ratios of RH in a total weight of 60 g,i.e.1∶0(RH1),2∶1(RH2),1∶2(RH3),and 0∶1(RH4).The extraction rates of Rg1,Rb1,and polysaccharides from different ratios of RH were then detected using UPLC-UV method.The SPS model was established,and RH1,RH2,RH3 and RH4(400 mg·kg-1)were administered by intragas-tric gavage for 14 day,followed by behavioral tests to e-valuate the PTSD-like behaviors.The serum CORT,IL-1β and IL-10 were determined by ELISA.The possible targets of action were analyzed using bioinformatics.The expression levels of Calpain-1,PSD95,BDNF and GluN2B in the hippocampus were detected by Western blot.Results The SPS model induced PTSD-like be-haviors in mice.Serum levels of CORT and IL-1β in-creased and level of IL-10 decreased in SPS model.After treatment with different ratios of RHs,RH2 showed the best therapeutic effect,which was manifes-ted in the suppression of PTSD-like behaviors,the re-duction of CORT and IL-1β levels,and the promotion of IL-10 levels;160 overlapping targets might explain the therapeutic effects of RH on PTSD,and these tar-gets were enriched in inhibiting synaptic damage,exer-ting antioxidant properties and suppressing neuroin-flammation,respectively.RH2 prevented the SPS-in-duced decrease in the expression of Calpain-1,PSD95,BDNF and the elevation of GluN2B.Molecular docking showed strong binding of Rg1 and Rb1 to Calpain-1,PSD95,and BDNF,respectively.Conclusions The a-queous extract of RH in a 2∶1 ratio can more effec-tively prevent SPS-induced PTSD-like behaviors,and its effect may be related to targets such as Calpain-1,PSD95,BDNF and GluN2B.
10.Deep learning image reconstruction algorithm in brain CT perfusion imaging with low tube voltage and reduced contrast agent dosage
Mengyuan ZHANG ; Luotong WANG ; Dian YUAN ; Yicun ZHANG ; Ke QI ; Weiting ZHANG ; Jiong ZHANG ; Songwei YUE ; Jianbo GAO ; Jie LIU
Chinese Journal of Medical Imaging Technology 2025;41(5):799-805
Objective To observe the value of deep learning image reconstruction(DLIR)algorithm in brain CT perfusion(CTP)using a protocol of 70 kVp and 40 ml contrast agent dose.Methods Totally 105 patients with suspected acute ischemic stroke(AIS)were prospectively enrolled and randomly divided into 3 groups,who underwent standard dose CTP scanning with 80 kVp and 150 mA combined with reconstruction as adaptive statistic iterative reconstruction V(ASIR-V)at 50%level(CN group,n=35),low dose(LD)scanning with 70 kVp and 100 mA combined with DLIR reconstruction at the highest level(DLIR-H)(LD group,n=35),or ultra-low dose(ULD)scanning with 70 kVp and 70 mA combined with DLIR-H reconstruction(ULD group,n=35).Radiation doses were compared among 3 groups.CT values and standard deviations(SDCT)of ROI of gray matter and white matter in the frontal,parietal and temporal lobes were measured.Signal-to-noise ratio(SNR)and contrast-to-noise ratio(CNR)between gray and white matter were calculated and compared among groups.Then pseudo-color images of cerebral blood volume(CBV),cerebral blood flow(CBF),mean transit time(MTT)and time to maximum of the tissue residual function(Tmax)were generated.The imaging quality of CTP pseudo-color images was evaluated,and the compatibility of the subjective scores within every kind of CTP pseudo-color images were assessed using Kappa test.Quantitative perfusion parameters were measured and compared among groups.Results Compared with CN group,both LD and ULD groups demonstrated significantly reduced volume CT dose index(CTDIvol),dose-length product(DLP)and effective dose(ED)(all adjusted P<0.05).In ULD group,SDCT of white matter in frontal,parietal and temporal lobes were higher than those in CN group,and SDCT of white matter in parietal lobe was also higher than that in LD group(all adjusted P<0.05).No significant difference of SDCT of gray matter was observed among groups(all P>0.05).SNR of white matter in parietal and temporal lobes in both LD and ULD groups were lower than those in CN group(all P<0.05),while no significant difference of SNR of white matter in frontal lobe,nor of gray matter in frontal,parietal and temporal lobes was found among groups(all P>0.05).CNR of gray and white matter in the frontal,parietal and temporal lobes were not significantly different among groups(all P>0.05).High consistency of inter-observer subjective scores of CBV maps,CBF maps and Tmax maps(Kappa of 0.623,0.644 and 0.638,respectively)were noticed,which of MTT maps had moderate consistency(Kappa=0.560).No significant difference of intra-obsever subjective scores of CTP pseudo-color images was found among groups(all P>0.05).CBV,CBF,MTT and Tmax values of gray and white matter in frontal,parietal and temporal lobes were not significantly different among groups(all P>0.05).Conclusion DLIR algorithm applicated in low radiation dose and reduced contrast agent dosage might ensure imaging quality.

Result Analysis
Print
Save
E-mail