1.Three-dimensional finite element analysis of molar distalization with clear aligners with different thicknesses and edges
Yanan CHENG ; Jiazhi YU ; Yinchang LIU ; Jie WU ; Tong YU ; Lu WANG ; Xiaoguang LI
Chinese Journal of Tissue Engineering Research 2026;30(2):310-318
BACKGROUND:One of the advantages of clear aligner treatment is molar distalization.However,tooth tilting movement and loss of anterior anchorage may occur during treatment.There are few studies on whether these problems can be improved by selecting clear aligners with different thicknesses and edges to improve the clinical treatment effect.OBJECTIVE:To analyze the control ability of clear aligners with different thickness and edges on the central incisor,lateral incisor,and second molar when pushing the maxillary second molar distally by three-dimensional finite element analysis.METHODS:Three-dimensional finite element analysis models of bilateral maxillary second molar distalization with clear aligner,maxillary dentition,periodontal ligament,and alveolar bone with different thicknesses and margins were established by Mimics,Geomagic Wrap,3-matic and SolidWorks software,respectively.There were 16 combinations of four thicknesses(0.4,0.5,0.625,and 0.75 mm)and four margins(scallop,straight,straight extension 2 mm and straight extension 4 mm).The data were imported into Ansys Workbench software for design and solution.The mean value,peak value and distribution of the periodontal ligament equivalent stress of the second molar,the equivalent stress and the maximum initial displacement of the second molar,and the control ability of each appliance on the second molar,central incisor,and lateral incisor were analyzed.RESULTS AND CONCLUSION:(1)The mean equivalent stress of periodontal ligament of the second molar,the equivalent stress of the second molar and the maximum initial displacement of the second molar increased with the extension of the appliance edge and the increase of the thickness of the appliance in the 16 groups of models.(2)When the thickness of appliances was the same,the maximum equivalent stress of the second molar in the linear appliance group was the highest,and the maximum equivalent stress of the second molar in the linear extended appliance group was greater than that in the scallop appliance group.When the edge of the appliance was the same,the periodontal ligament equivalent stress peak of the second molar increased with the increase of the thickness of the appliance.The equivalent stress distribution in the periodontal ligament of the second molar in the linear extendable appliance group was more uniform than that in the scallop appliance group and the linear appliance group.(3)When the thickness of the appliance was the same,the scallop-shaped appliance had the worst control on the second molar.When the edge of the appliance was the same,with the increase of the thickness of the appliance,the control of the second molar by the linear extender appliance was gradually stronger than that by the linear appliance.The control of the central incisor was stronger and more stable with the linear extended 2 mm appliance,while the control of the lateral incisor was stronger and more stable with the linear appliance.(4)The results showed that when using clear aligners to push molars distally,extending the edge of the appliance could improve the control of the molars and reduce the tilting movement of the teeth.The design of a straight extension margin of 2 mm for the central incisor and a straight edge for the lateral incisor can enhance the control of the anchorage incisor and reduce the labial inclination of the anterior teeth.
2.Three-dimensional finite element analysis of molar distalization with clear aligners with different thicknesses and edges
Yanan CHENG ; Jiazhi YU ; Yinchang LIU ; Jie WU ; Tong YU ; Lu WANG ; Xiaoguang LI
Chinese Journal of Tissue Engineering Research 2026;30(2):310-318
BACKGROUND:One of the advantages of clear aligner treatment is molar distalization.However,tooth tilting movement and loss of anterior anchorage may occur during treatment.There are few studies on whether these problems can be improved by selecting clear aligners with different thicknesses and edges to improve the clinical treatment effect.OBJECTIVE:To analyze the control ability of clear aligners with different thickness and edges on the central incisor,lateral incisor,and second molar when pushing the maxillary second molar distally by three-dimensional finite element analysis.METHODS:Three-dimensional finite element analysis models of bilateral maxillary second molar distalization with clear aligner,maxillary dentition,periodontal ligament,and alveolar bone with different thicknesses and margins were established by Mimics,Geomagic Wrap,3-matic and SolidWorks software,respectively.There were 16 combinations of four thicknesses(0.4,0.5,0.625,and 0.75 mm)and four margins(scallop,straight,straight extension 2 mm and straight extension 4 mm).The data were imported into Ansys Workbench software for design and solution.The mean value,peak value and distribution of the periodontal ligament equivalent stress of the second molar,the equivalent stress and the maximum initial displacement of the second molar,and the control ability of each appliance on the second molar,central incisor,and lateral incisor were analyzed.RESULTS AND CONCLUSION:(1)The mean equivalent stress of periodontal ligament of the second molar,the equivalent stress of the second molar and the maximum initial displacement of the second molar increased with the extension of the appliance edge and the increase of the thickness of the appliance in the 16 groups of models.(2)When the thickness of appliances was the same,the maximum equivalent stress of the second molar in the linear appliance group was the highest,and the maximum equivalent stress of the second molar in the linear extended appliance group was greater than that in the scallop appliance group.When the edge of the appliance was the same,the periodontal ligament equivalent stress peak of the second molar increased with the increase of the thickness of the appliance.The equivalent stress distribution in the periodontal ligament of the second molar in the linear extendable appliance group was more uniform than that in the scallop appliance group and the linear appliance group.(3)When the thickness of the appliance was the same,the scallop-shaped appliance had the worst control on the second molar.When the edge of the appliance was the same,with the increase of the thickness of the appliance,the control of the second molar by the linear extender appliance was gradually stronger than that by the linear appliance.The control of the central incisor was stronger and more stable with the linear extended 2 mm appliance,while the control of the lateral incisor was stronger and more stable with the linear appliance.(4)The results showed that when using clear aligners to push molars distally,extending the edge of the appliance could improve the control of the molars and reduce the tilting movement of the teeth.The design of a straight extension margin of 2 mm for the central incisor and a straight edge for the lateral incisor can enhance the control of the anchorage incisor and reduce the labial inclination of the anterior teeth.
3.Experimental study on the ultrasound visibility of a novel interventional catheter and delivery system: In vitro and animal experiments
Ziping LI ; Wenbin OUYANG ; Zizheng LIU ; Ning ZHOU ; Jie DONG ; Shouzheng WANG ; Xiangbin PAN
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2026;33(05):784-790
Objective To assess the echogenicity of the ultrasound-guided catheter and its associated delivery system. Methods The study consisted of in vitro characterization experiments and animal studies. In the in vitro phase, the acoustic and mechanical properties of the ultrasound-guided catheter were compared with those of the traditional MPA2 catheter, including parameters such as echo intensity, recognizability, and angle dependence. In the animal experiments, a ventricular septal defect (VSD) model was established in miniature pigs to compare the procedural performance of the ultrasound-guided delivery system versus the conventional system. Evaluation indicators included the time required for the system to cross the VSD, the detection rate of the system within the right ventricle, and the occurrence of intraoperative complications. Results The ultrasound-guided catheter demonstrated a significantly higher mean echo intensity than the MPA2 catheter [(237.3±1.8) dB vs. (190.9±13.1) dB, P<0.001] and a markedly improved recognizability rate (82.3%±5.6% vs. 26.7%±3.2%, P<0.001), along with better angle independence and image quality. In animal experiments, the ultrasound-guided delivery system significantly reduced the time required to cross the VSD [(18.5±5.7) min vs. (30.3±4.5) min, P<0.001] and substantially increased the detection rate within the right ventricle (100.0% vs. 30.0%). No severe complications occurred in any experimental animal. Conclusion The ultrasound-guided catheter and its corresponding delivery system exhibite superior ultrasound visibility and operational performance in both in vitro and animal experiments, indicating strong potential for clinical application.
4.Electroacupuncture Ameliorates NLRP3-mediated Pyroptosis in Spinal Cord Injury Rats by Reshaping The Gut Microbiota
Yin-Jie CUI ; Hong-Ru LI ; Jing-Yi LIU ; Hai-Lin DU ; Shu-Wen LIU ; Yuan YANG ; Chen-Guang ZHENG ; Jian-Qin XIANG ; Xiao-Juan SONG
Progress in Biochemistry and Biophysics 2026;53(5):1132-1153
ObjectiveSpinal cord injury (SCI) directly impairs the regulatory function of the autonomic nervous system, induces intestinal dysfunction, and significantly reduces patients’ quality of life. Preclinical studies have shown that electroacupuncture (EA) therapy can regulate the brain-gut axis and is used to treat central nervous system diseases such as major depressive disorder, Alzheimer’s disease and Parkinson’s disease. Recent research has established that fecal microbiota transplantation (FMT) from EA-treated SCI rats restored intestinal motility and colonic morphology. However, it remains unclear whether the regulation of gut microbiota by EA therapy directly contributes to neural repair after SCI. This study aims to explore whether gut microbiota mediates the neuroprotective effect of EA in the treatment of SCI and its possible mechanism. MethodsThe study employed RNA transcriptome analysis of spinal cord tissue to characterize gene expression profiles and to identify key signaling pathways following EA treatment for SCI. Hematoxylin-Eosin (HE) staining and Nissl staining were used to observe the morphological changes in spinal cord tissue. Western blot (WB) and enzyme-linked immunosorbent assay (ELISA) were applied to detect the effects of EA on the expression of proteins related to nucleotide-binding domain leucine-rich repeat and pyrin domain-containing receptor 3 (NLRP3) -dependent pyroptosis. Using 16S rDNA sequencing, the study observed alterations in gut microbiota diversity and community composition in SCI rats. Prior to establishing SCI models, rats were pretreated with an antibiotic cocktail to induce gut dysbiosis, and the effects on intestinal function and spinal cord neural repair were evaluated. FMT was performed to investigate the regulatory effects of post-EA FMT on motor function, general status, liver and spleen indices, and NLRP3-mediated pyroptosis in SCI rats. ResultsEA improved motor function and reduced regulated neuronal cell death in SCI rats. Transcriptomic analysis demonstrated the activation of immune- and inflammation-related pathways post-SCI, including NOD-like receptors, nuclear factor-kappa B(NF-κB), and Toll-like receptor (TLR) pathways. EA primarily influenced intestinal inflammation and autoimmune functions. 16S rDNA sequencing illustrated that EA did not alter the diversity of gut microbiota. However, EA altered the gut microbiota composition in SCI rats, increasing Lactobacillus and Akkermansia genera while rebalancing the Firmicutes/Bacteroidetes ratio. Furthermore, depletion of gut microbiota by antibiotics disrupted the intestinal barrier, reduced the expression of intestinal barrier proteins Zonula Occludens-1 (ZO-1) and Occludin, elevated serum lipopolysaccharide-binding protein (LBP) levels, exacerbated spinal cord tissue damage, and hindered motor function recovery in SCI rats. FMT from donors treated with EA reduced LBP levels in the intestine, blood, and spinal cord of rats, inhibited the TLR4 myeloid differentiation primary response protein 88 (MyD88)-NF‑κB pathway and NLRP3-dependent pyroptosis, and improved motor function. On the other hand, FMT treatment resulted in decreased body weight and food intake, whereas FMT using EA-treated donors effectively alleviated these alterations. ConclusionEA effectively alleviated neuroinflammatory responses in rats with SCI, primarily through regulating the gut microbiota and suppressing the NLRP3-dependent pyroptosis signaling pathway.
5.Clinical and epidemiological characteristics of human bocavirus in hospitalized children with acute lower respiratory tract infection at a hospital in Shanghai from 2021 to 2023
Shan ZHANG ; Yujuan HUANG ; Lei SHEN ; Li LIU ; Jie WANG ; Huilin ZHOU ; Leijun MENG ; Tingting CHEN
Shanghai Journal of Preventive Medicine 2026;38(3):193-198
ObjectiveTo investigate the epidemiological and clinical characteristics of human bocavirus (HBoV) in hospitalized children with acute lower respiratory tract infection (ALRTI) at a single-center children’s hospital in Shanghai, thereby providing evidence for the diagnosis, treatment, and prevention of HBoV infection. MethodsA retrospective study was conducted on 19 537 hospitalized children with ALRTI at Shanghai Children’s Hospital from January 2021 to December 2023. Multiplex polymerase chain reaction (PCR) combined with capillary electrophoresis was used to detect HBoV and 12 other common respiratory viruses /atypical pathogens. The positive detection rate, demographic characteristics (sex, age), temporal distribution (year, season) of HBoV, as well as the clinical characteristics of severe and non-severe pneumonia were analyzed. ResultsThe overall HBoV-positive rate was 2.57% (503/19 537), with 59.44% (299/503) being single infections and 40.56% (204/503) being co-infections. The positive detection rate was significantly higher in boys than that in girls (2.78% vs 2.33%, χ²=3.88, P=0.049). The highest infection rate was observed in toddlers, followed by infants (χ²=379.57, P<0.001). The positive rate peaked in 2021 and reached its lowest point in 2023 (χ²=45.49, P<0.001), with epidemics mainly prevalent in summer and autumn. The main clinical symptoms were cough (90.06%, 453/503), fever (75.94%, 382/503), and wheezing (39.96%, 201/503). Children with severe pneumonia showed a higher incidence of wheezing compared with the non-severe group (P<0.001), while underlying diseases and co-infections had no significant association with disease severity (P>0.05). ConclusionHBoV was an important pathogen of ALRTI in children, predominantly affecting infants and toddlers, with higher susceptibility in boys and seasonal peaks in autumn and summer. The main clinical manifestations included cough, fever, and wheezing, with wheezing being more prevalent in children with severe pneumonia.
6.Electroacupuncture Ameliorates NLRP3-mediated Pyroptosis in Spinal Cord Injury Rats by Reshaping The Gut Microbiota
Yin-Jie CUI ; Hong-Ru LI ; Jing-Yi LIU ; Hai-Lin DU ; Shu-Wen LIU ; Yuan YANG ; Chen-Guang ZHENG ; Jian-Qin XIANG ; Xiao-Juan SONG
Progress in Biochemistry and Biophysics 2026;53(5):1132-1153
ObjectiveSpinal cord injury (SCI) directly impairs the regulatory function of the autonomic nervous system, induces intestinal dysfunction, and significantly reduces patients’ quality of life. Preclinical studies have shown that electroacupuncture (EA) therapy can regulate the brain-gut axis and is used to treat central nervous system diseases such as major depressive disorder, Alzheimer’s disease and Parkinson’s disease. Recent research has established that fecal microbiota transplantation (FMT) from EA-treated SCI rats restored intestinal motility and colonic morphology. However, it remains unclear whether the regulation of gut microbiota by EA therapy directly contributes to neural repair after SCI. This study aims to explore whether gut microbiota mediates the neuroprotective effect of EA in the treatment of SCI and its possible mechanism. MethodsThe study employed RNA transcriptome analysis of spinal cord tissue to characterize gene expression profiles and to identify key signaling pathways following EA treatment for SCI. Hematoxylin-Eosin (HE) staining and Nissl staining were used to observe the morphological changes in spinal cord tissue. Western blot (WB) and enzyme-linked immunosorbent assay (ELISA) were applied to detect the effects of EA on the expression of proteins related to nucleotide-binding domain leucine-rich repeat and pyrin domain-containing receptor 3 (NLRP3) -dependent pyroptosis. Using 16S rDNA sequencing, the study observed alterations in gut microbiota diversity and community composition in SCI rats. Prior to establishing SCI models, rats were pretreated with an antibiotic cocktail to induce gut dysbiosis, and the effects on intestinal function and spinal cord neural repair were evaluated. FMT was performed to investigate the regulatory effects of post-EA FMT on motor function, general status, liver and spleen indices, and NLRP3-mediated pyroptosis in SCI rats. ResultsEA improved motor function and reduced regulated neuronal cell death in SCI rats. Transcriptomic analysis demonstrated the activation of immune- and inflammation-related pathways post-SCI, including NOD-like receptors, nuclear factor-kappa B(NF-κB), and Toll-like receptor (TLR) pathways. EA primarily influenced intestinal inflammation and autoimmune functions. 16S rDNA sequencing illustrated that EA did not alter the diversity of gut microbiota. However, EA altered the gut microbiota composition in SCI rats, increasing Lactobacillus and Akkermansia genera while rebalancing the Firmicutes/Bacteroidetes ratio. Furthermore, depletion of gut microbiota by antibiotics disrupted the intestinal barrier, reduced the expression of intestinal barrier proteins Zonula Occludens-1 (ZO-1) and Occludin, elevated serum lipopolysaccharide-binding protein (LBP) levels, exacerbated spinal cord tissue damage, and hindered motor function recovery in SCI rats. FMT from donors treated with EA reduced LBP levels in the intestine, blood, and spinal cord of rats, inhibited the TLR4 myeloid differentiation primary response protein 88 (MyD88)-NF‑κB pathway and NLRP3-dependent pyroptosis, and improved motor function. On the other hand, FMT treatment resulted in decreased body weight and food intake, whereas FMT using EA-treated donors effectively alleviated these alterations. ConclusionEA effectively alleviated neuroinflammatory responses in rats with SCI, primarily through regulating the gut microbiota and suppressing the NLRP3-dependent pyroptosis signaling pathway.
7.Establishment and application of the method for plasma concentration determination of lamotrigine,levetiracetam and perampanel in children with epilepsy
Wenlin SONG ; Ying ZHOU ; Haoran CHEN ; Ziyue LIN ; Yan LI ; Jie LIU ; Taiwei JIN ; Xuqiang ZHOU
China Pharmacy 2026;37(10):1313-1317
OBJECTIVE To establish a method for simultaneous determination of plasma concentration of lamotrigine(LTG), levetiracetam(LEV) and perampanel(PER) in children with epilepsy and apply this method in clinical practice. METHODS Plasma proteins were precipitated with acetonitrile. Using PER-D 5 as internal standard, ultra-high performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method was adopted. The determination was performed on ACQUITY UPLC HSS T3 C 18 column with mobile phase consisted of 0.1% formic acid with 5 mmol/L ammonium acetate-acetonitrile (gradient elution) at the flow rate of 0.3 mL/min. The column temperature was 40 ℃, and sample size was 5 μL. The analysis time was 5 min. The electrospray ionization source and multiple reaction monitoring mode were used for positive ion scanning. The ion pairs used for quantitative analysis of LTG, LEV, PER and internal standard were m / z 255.9→144.9, m / z 171.1→126.1, m / z 350.1→219.0 and m / z 354.9→220.2, respectively. The steady-state trough concentrations of the aforementioned drugs in the plasma of 14 pediatric epilepsy patients receiving combination therapy were determined using the same UPLC-MS/MS method as above. RESULTS The linear ranges of LTG, LEV and PER were 0.15-24 μg/mL ( R 2 >0.993), 0.312 5-50 μg/mL ( R 2 >0.997) and 6.25-1 000 ng/mL ( R 2 >0.997), respectively. The lower limits of quantification were 0.15 μg/mL, 0.312 5 μg/mL and 6.25 ng/mL, respectively. RSDs of intraday and interday precision tests of the three drugs were no more than 9.83%, and the accuracies (relative errors) were between -9.33% and 13.72%( n =6 or n =18); the average extraction recovery rates were 86.4%-97.9%, and the average matrix effects were 86.9%-110.0% ( n =6). The absolute values of the relative errors in the stability tests were all below 15%. The steady-state trough concentrations of LTG, LEV and PER were (5.64±4.03)μg/mL, (10.67±8.78)μg/mL and(450.20±251.27)ng/mL, respectively; the rates of achieving target trough concentrations were 71.4%, 37.5% and 84.6%, respectively. CONCLUSIONS The established UPLC-MS/MS method is specific, rapid and suitable for the plasma concentration monitoring in epileptic children receiving combination therapy.
8.Effects of subanesthetic dose of esketamine on postoperative anxiety and recovery in patients undergoing laparo-scopic cholecystectomy
Zhangzhen ZHONG ; Xian ZHENG ; Ting XU ; Jie WANG ; Hui CAO ; Xinggen ZHOU ; Hui LI ; Jiacheng ZHAO ; Hui LIU ; Chao ZHANG
China Pharmacy 2026;37(2):204-209
OBJECTIVE To investigate the effects of subanesthetic dose of esketamine on postoperative anxiety and recovery in patients undergoing laparoscopic cholecystectomy. METHODS A total of 200 patients scheduled for laparoscopic cholecystectomy at Suzhou Ninth Hospital Affiliated to Soochow University from January 2023 to December 2024 were randomly assigned to control group (n=100) and observation group (n=100). One minute before the initiation of anesthesia, patients in the control group received intravenous injections of Propofol emulsion injection, Sufentanil citrate injection, and Succinylcholine chloride injection. On this basis, patients in the observation group received an intravenous injection of Esketamine hydrochloride injection. The anxiety status of patients in both groups was compared, along with their general intraoperative conditions (including sufentanil dosage, duration of pneumoperitoneum, operative time, anesthesia time, and extubation time), postoperative recovery, incidence of adverse reactions, and the need for dezocine rescue analgesia. Heart rate and mean arterial pressure, entropy index (state entropy and response entropy), inflammatory marker levels [interleukin-6 (IL-6) and C-reactive protein (CRP)], numerical rating scale (NRS) for pain intensity were compared between the two groups at different time points. RESULTS No significant differences were found between the two groups in pneumoperitoneum duration, operative time, anesthesia time,extubation time, incidence of postoperative dry mouth, entropy index or length of stay in the post-anesthesia care unit (P>0.05). Compared with the control group, the observation group showed significantly lower postoperative STAI-S scores, reduced intraoperative sufentanil consumption, decreased incidence of postoperative nausea, vomiting, and shivering, the need for dezocine rescue analgesia, as well as lower plasma IL-6 and CRP levels at 24 h after surgery, and NRS (P<0.05). The heart rate and mean arterial pressure of patients in the observation group at the start of surgery, end of surgery, and during extubation were all significantly higher than those in the control group (P<0.05). CONCLUSIONS Subanesthetic dose of esketamine can effectively alleviate postoperative anxiety, reduce intraoperative opioid consumption, suppress postoperative inflammatory response, relieve postoperative pain, and promote recovery in patients undergoing laparoscopic cholecystectomy.
9.Expert consensus on neoadjuvant PD-1 inhibitors for locally advanced oral squamous cell carcinoma (2026)
LI Jinsong ; LIAO Guiqing ; LI Longjiang ; ZHANG Chenping ; SHANG Chenping ; ZHANG Jie ; ZHONG Laiping ; LIU Bing ; CHEN Gang ; WEI Jianhua ; JI Tong ; LI Chunjie ; LIN Lisong ; REN Guoxin ; LI Yi ; SHANG Wei ; HAN Bing ; JIANG Canhua ; ZHANG Sheng ; SONG Ming ; LIU Xuekui ; WANG Anxun ; LIU Shuguang ; CHEN Zhanhong ; WANG Youyuan ; LIN Zhaoyu ; LI Haigang ; DUAN Xiaohui ; YE Ling ; ZHENG Jun ; WANG Jun ; LV Xiaozhi ; ZHU Lijun ; CAO Haotian
Journal of Prevention and Treatment for Stomatological Diseases 2026;34(2):105-118
Oral squamous cell carcinoma (OSCC) is a common head and neck malignancy. Approximately 50% to 60% of patients with OSCC are diagnosed at a locally advanced stage (clinical staging III-IVa). Even with comprehensive and sequential treatment primarily based on surgery, the 5-year overall survival rate remains below 50%, and patients often suffer from postoperative functional impairments such as difficulties with speaking and swallowing. Programmed death receptor-1 (PD-1) inhibitors are increasingly used in the neoadjuvant treatment of locally advanced OSCC and have shown encouraging efficacy. However, clinical practice still faces key challenges, including the definition of indications, optimization of combination regimens, and standards for efficacy evaluation. Based on the latest research advances worldwide and the clinical experience of the expert group, this expert consensus systematically evaluates the application of PD-1 inhibitors in the neoadjuvant treatment of locally advanced OSCC, covering combination strategies, treatment cycles and surgical timing, efficacy assessment, use of biomarkers, management of special populations and immune related adverse events, principles for immunotherapy rechallenge, and function preservation strategies. After multiple rounds of panel discussion and through anonymous voting using the Delphi method, the following consensus statements have been formulated: 1) Neoadjuvant therapy with PD-1 inhibitors can be used preoperatively in patients with locally advanced OSCC. The preferred regimen is a PD-1 inhibitor combined with platinum based chemotherapy, administered for 2-3 cycles. 2) During the efficacy evaluation of neoadjuvant therapy, radiographic assessment should follow the dual criteria of Response Evaluation Criteria in Solid Tumors (RECIST) version 1.1 and immune RECIST (iRECIST). After surgery, systematic pathological evaluation of both the primary lesion and regional lymph nodes is required. For combination chemotherapy regimens, PD-L1 expression and combined positive score need not be used as mandatory inclusion or exclusion criteria. 3) For special populations such as the elderly (≥ 70 years), individuals with stable HIV viral load, and carriers of chronic HBV/HCV, PD-1 inhibitors may be used cautiously under the guidance of a multidisciplinary team (MDT), with close monitoring for adverse events. 4) For patients with a poor response to neoadjuvant therapy, continuation of the original treatment regimen is not recommended; the subsequent treatment plan should be adjusted promptly after MDT assessment. Organ transplant recipients and patients with active autoimmune diseases are not recommended to receive neoadjuvant PD-1 inhibitor therapy due to the high risk of immune related activation. Rechallenge is generally not advised for patients who have experienced high risk immune related adverse events such as immune mediated myocarditis, neurotoxicity, or pneumonitis. 5) For patients with a good pathological response, individualized de escalation surgery and function preservation strategies can be explored. This consensus aims to promote the standardized, safe, and precise application of neoadjuvant PD-1 inhibitor strategies in the management of locally advanced OSCC patients.
10.Expert recommendations on vision friendly built environments for myopia prevention and control in children and adolescents
Chinese Journal of School Health 2026;47(1):1-5
Abstract
The prevention and control of myopia in Chinese children and adolescents has become a major public health issue. While maintaining increased outdoor activity as a cornerstone intervention, there is an urgent need to explore new complementary approaches that can be effectively implemented in both indoor and outdoor settings. In recent years, environmental spatial frequency has gained increasing attention as one of the key environmental factors influencing the development and progression of myopia. Both animal studies and human research have confirmed that indoor environments lacking mid to high spatial frequency components, often characterized as "visually impoverished", can promote axial elongation and myopia through mechanisms such as disruption of retinal neural signaling, impaired accommodative function, and altered expression of related molecules. Based on the scientific consensus, it is recommended that "enriching of environmental spatial frequency" should be integrated into the myopia prevention and control framework. Following the principles of schoolled organization, family cooperation, community involvement, and student participation, specific measures are put forward in three areas:optimizing school visual settings, improving home spatial environments, and promoting healthy visual behavior. The aim is to create "visually friendly" indoor environments as an important supplement to outdoor activity, thereby providing a novel perspective and strategy for comprehensively advancing myopia prevention and control among children and adolescents.


Result Analysis
Print
Save
E-mail