1.Application of wide awake local anesthesia no tourniquet technique in locking of metacarpophalangeal joint with extension lag surgery
Guo-tao YANG ; Hua-jie MAO ; Zhi-jun CHEN ; Xu ZHANG ; Huan HU ; Qi-ting JIANG
Journal of Regional Anatomy and Operative Surgery 2025;34(9):836-839
Objective To explore the application value of wide awake local anesthesia no tourniquet(WALANT)technique in outpatient surgery for locking of metacarpophalangeal joint with extension lag.Methods The clinical data of 6 patients with locking of meta-carpophalangeal joint with extension lag in Danyang People's Hospital from January 2019 to October 2023 were retrospectively analyzed.The patients were received outpatient surgery under the WALLANT technique for release,and lidocaine mixed solution containing 1∶100 000 epinephrine was injected into the proximal midpoint of the volar projection of the metacarpophalangeal joint.The joint was exposed with a volar or dorsal finger web incision to determine the unrestricted structure,and the collateral ligament and paralateral collateral ligament with high tension were cut off.The intraoperative blood loss,postoperative incision healing and complications were recorded.Visual analogue scale(VAS)was used to evaluate the intraoperative pain,and the range of motion of metacarpophalangeal joint and total active movement(TAM)of finger joint were observed during postoperative follow-up.Results The incision of patients were healed successfully in the first phase after surgery,without wound necrosis.The anesthesia effects of patients were all satisfied and the operation was successfully completed.The VAS score was less than 3 points and there was only a small amount of bleeding during the operation.The recovery of joint flexion and extension movements could be observed during the operation,and the TAM score after the operation was 20 points.No significant change was found on the range of motion of metacarpophalangeal joint or TAM of finger joint between the injured finger and the corresponding healthy finger(P>0.05).Conclusion WALANT technique for locking of metacarpophalangeal joint with extension lag surgery has good anesthesia effect,less bleeding in the incision,and clear vision of the surgery.It can avoid vascular and nerve injuries,observe the recovery of joint activities during the operation and relieve pain of patients,which is conducive to outpatient surgery and saving medical and social resources at the same time.
2.Application of remimazolam combined with nalbuphine anesthesia in painless gastroscopy
Zhi-jie LIU ; Yong-xue CHEN ; Xing ZHAO ; Yang GAO ; Si-yuan LI
Journal of Regional Anatomy and Operative Surgery 2025;34(8):698-701
Objective To explore the anesthetic effects of remimazolam combined with nalbuphine on patients undergoing painless gastroscopy.Methods A total of 120 patients who underwent painless gastroscopy in Handan Central Hospital from August 2019 to May 2021 were selected and randomly divided into the observation group(60 cases)and the control group(60 cases).Patients in the observation group anesthetized with remimazolam and nalbuphine,while patients in the control group anesthetized with propofol and alfentanil.The vital signs,sedative effect,recovery quality,cognitive function,and adverse reactions of patients were compared between the two groups.Results The heart rate(HR),respiratory rate(RR),and the level of pulse oxygen saturation(SpO2)of patients in the observation group were significantly higher than those in the control group(P<0.05).Five minutes after the examination,the Narcotrend score of patients in the observation group was significantly lower than that in the control group(P<0.05).The time from the last administration to awakening,the time from gastroscopy removal to awakening,and the time of leaving the anesthesia recovery room of patients in the observation group were significantly shorter than those in the control group(P<0.05).Five minutes after the examination,the score of the mini-mental state examination(MMSE)of patients in the observation group was significantly higher than that in the control group(P<0.05),while the incidence of adverse reactions was significantly lower than that in the control group(P<0.05).Conclusion The application of remimazolam combined with nalbuphine anesthesia in painless gastroscopy has a relatively ideal effect,which can effectively reduce the adverse reactions of patients and promote rapid postoperative recovery.
3.Expert Consensus on the Ethical Requirements for Generative AI-Assisted Academic Writing
You-Quan BU ; Yong-Fu CAO ; Zeng-Yi CHANG ; Hong-Yu CHEN ; Xiao-Wei CHEN ; Yuan-Yuan CHEN ; Zhu-Cheng CHEN ; Rui DENG ; Jie DING ; Zhong-Kai FAN ; Guo-Quan GAO ; Xu GAO ; Lan HU ; Xiao-Qing HU ; Hong-Ti JIA ; Ying KONG ; En-Min LI ; Ling LI ; Yu-Hua LI ; Jun-Rong LIU ; Zhi-Qiang LIU ; Ya-Ping LUO ; Xue-Mei LV ; Yan-Xi PEI ; Xiao-Zhong PENG ; Qi-Qun TANG ; You WAN ; Yong WANG ; Ming-Xu WANG ; Xian WANG ; Guang-Kuan XIE ; Jun XIE ; Xiao-Hua YAN ; Mei YIN ; Zhong-Shan YU ; Chun-Yan ZHOU ; Rui-Fang ZHU
Chinese Journal of Biochemistry and Molecular Biology 2025;41(6):826-832
With the rapid development of generative artificial intelligence(GAI)technologies,their widespread application in academic research and writing is continuously expanding the boundaries of sci-entific inquiry.However,this trend has also raised a series of ethical and regulatory challenges,inclu-ding issues related to authorship,content authenticity,citation accuracy,and accountability.In light of the growing involvement of AI in generating academic content,establishing an open,controllable,and trustworthy ethical governance framework has become a key task for safeguarding research integrity and maintaining trust within the academic community.This expert consensus outlines ethical requirements across key stages of AI-assisted academic writing-including topic selection,data management,citation practices,and authorship attribution.It aims to clarify the boundaries and ethical obligations surrounding AI use in academic writing,ensuring that technological tools enhance efficiency without compromising in-tegrity.The goal is to provide guidance and institutional support for building a responsible and sustainable research ecosystem.
4.Design and application of novel protective ventilator circuit component
Wei-zhou WU ; Kang LU ; Jing-jie CAO ; Zhi-hua ZHAO ; Hai-tao LAN ; Zan-chao CHEN ; Qing-feng XUE
Chinese Medical Equipment Journal 2025;46(4):113-117
Objective To develop a novel protective ventilator circuit component and to verify its performance by water seal and anti-splash experiments.Methods A novel protective ventilator circuit component had a design scheme with the multifunctional joint,and consisted of a tee connection tube,an isolation sleeve and a stop sleeve,of which,the tee connection tube was made of polyethylene polymer material and the others were made of silicone material.The tee connection tube had a T-shaped structure with two standard connection ports,which was composed of an adapter,a sealing cap,a plug and a sealing ring;the isolation sleeve was in the shape of a cylinder with a raised bottom,which was inserted into the adapter;the stop sleeve was located in the isolation sleeve,with an inverted frustum of a cone at the bottom and a rounded hole in the middle of the inverted frustum.An open ventilator circuit tube was involved in the performance verification of the circuit component developed.In the water seal experiment,sputum aspiration was simulated and the heights of the liquid level drop in the L-shaped tubes were compared after sputum aspiration.In the anti-splash experiment,the infection rates on the surfaces of the sterile hole towels and gloves were calculated.Results Water seal experiment showed after sputum aspiration the open ventilator circuit tube had the liquid level at the L-shaped tube higher significantly than that of the circuit component;the anti-splash experiment indicated sputum aspiration resulted in the occurance of the splashing out of the secretion and 77.5%infection rate by the open ventilator circuit tube,while no splashing out and 0%infection rate by the circuit component developed.Conclusion The novel protective ventilator circuit component behaves well in sealing and anti-splashing,and thus is worthy of clinical application for sputum aspiration.[Chinese Medical Equipment Journal,2025,46(4):113-117]
5.Comparison of differences in dosimetry and treatment efficiency of modified radiotherapy plans after left-sided breast-conserving surgery
Jian-hai LIN ; Jing FENG ; Zhong-hua CHEN ; Zhi-chao FU ; Jie CHEN ; Nan-bao ZHONG
Chinese Medical Equipment Journal 2025;46(4):45-51
Objective To compare the differences in dosimetry and treatment efficiency of three radiotherapy plans after left-sided breast-conserving surgery,including modified intensity-modulated radiation therapy(IMRT),cross-field volume-modulated arc therapy(VMAT)or improved VMAT,so as to provide references for clinical practice.Methods Three radiotherapy plans of modified IMRT,cross-field VMAT and improved VMAT were designed for 12 patients after left-sided-breast-conserving surgery.The modified IMRT with five irradiation fields and the improved VMAT with two arcs were modified by not setting cross-fields while determining the start and end angles with the rays passing through the least lung area.The cross-field VMAT had its start and end angles set based on the cross-fields.The doses to the target areas,peripheral organs at risk,heart and its substructures were evaluated,and dose verification was carried out.The three plans were compared in terms of treatment efficiency and gamma pass rate.SPSS 22.0 was used for statistical analysis.Results All the three plans behaved well in dose distribution.In terms of planning gross tumor volume dosimetry dosimetry,the improved VMAT and modified IMRT gained advantages than others in CI and D50,respectively,with the differences being significant(all P<0.05).In terms of planning target volume dosimetry,the modified IMRT had the V107 and D50 lower than those of the others,with the differences being significant(P<0.05).In terms of the protection of peripheral organs at risk,V5 of the left lung,Dmean of the right lung and Dmean of the healthy breast were lower in the modified IMRT plan than in the other 2 plans,with statistically significant differences(P<0.05);V20,V30,V35 and V40 of the left lung were lower in the modified VMAT plan than in the other 2 plans,with statistically significant differences(P<0.05).In terms of protection of heart and its substructures,the left ventricle V20,V30 and Dmean of the improved VMAT plan behaved better than those of other 2 plans,and the difference was statistically significant(all P<0.05).In terms of treatment efficiency,the cross-field VMAT plan had the lowest MU while highest treatment efficiency;the improved VMAT plan had the MU higher while the treatment efficiency lower than the cross-field VMAT plan;the modified IMRT plan had the highest MU while the lowest gamma pass rate,and the differences in the MUs and gamma pass rates among the three plans were statistically significant(P<0.05).Conclusion Under the same standard conditions,the cross-field VMAT and improved VMAT plans show technical advantages.Though the improved VMAT plan has the treatment efficiency lower than the cross-field VMAT,it decreases the possibility of radiocardiac injury in terms of dosimetry and thus can be used for radiotherapy after left-sided breast-conserving surgery.[Chinese Medical Equipment Journal,2025,46(4):45-51]
6.Application of pulmonary rehabilitation integrated care management mode based on internet of things platform in patients with chronic obstructive pulmonary disease
Zhi LU ; Qiyu DONG ; Da LIU ; Huamei CHEN ; Lu YANG ; Jie DONG
Chinese Journal of Practical Nursing 2025;41(24):1866-1873
Objective:This study implemented a pulmonary rehabilitation integrated care management model based on an Internet of things platform for patients with chronic obstructive pulmonary disease (COPD) and evaluated its effectiveness to provide evidence for clinical respiratory rehabilitation practices.Methods:A quasi-experimental design was adopted. Patients from the Department of Respiratory and Critical Care Medicine at Changsha Central Hospital Affiliated to University of South China between May and December 2023 were selected via purposive sampling. Sixty COPD patients from May to August 2023 were assigned to the control group, while 60 patients from September to December 2023 were assigned to the comprehensive management group. The control group adopted routine respiratory rehabilitation management, the comprehensive management group adopted a pulmonary rehabilitation integarted care management mode based on Internet of things platform respiratory rehabilitation. Before and after 6 months of intervention, patients were assessed for respiratory rehabilitation compliance, lung function (including the percentage of forced expiratory volume in the first second to the expected value (FEV 1% pred) and the ratio of forced expiratory volume in the first second to forced vital capacity (FEV 1/FVC), 6-minute walk test (6MWT) and COPD Assessment Test (CAT). Results:Finally, 55 cases were included in the control group and 59 cases were included in the comprehensive management group. The control group included 32 males and 23 females, aged (67.31 ± 7.14) years. The comprehensive management group included 39 males and 20 females, aged (68.15 ± 6.34) years. The respiratory rehabilitation compliance score, FEV 1% pred, FEV 1/FVC, 6MWT, and CAT score of the full management group after intervention were as follows: (26.45 ± 1.51) points, (59.21 ± 6.68)%, (78.35 ± 8.01)%, (479.63 ± 54.70) m, and (12.35 ± 4.01) points, which were all better than the control group′s (15.68 ± 1.56) points, (44.09 ± 6.31)%, (68.38 ± 6.43)%, (429.82 ± 60.50) m, and (17.03 ± 4.23) points. The difference between two groups were significant ( t values were 1.83-5.24, all P<0.05). Conclusions:The pulmonary rehabilitation integarted care management model based on Internet of things platform improves patient compliance, enhances pulmonary function, enhance their activity endurance, and improve their quality of life. It is worth promoting and using in clinical practice.
7.Design and application of novel protective ventilator circuit component
Wei-zhou WU ; Kang LU ; Jing-jie CAO ; Zhi-hua ZHAO ; Hai-tao LAN ; Zan-chao CHEN ; Qing-feng XUE
Chinese Medical Equipment Journal 2025;46(4):113-117
Objective To develop a novel protective ventilator circuit component and to verify its performance by water seal and anti-splash experiments.Methods A novel protective ventilator circuit component had a design scheme with the multifunctional joint,and consisted of a tee connection tube,an isolation sleeve and a stop sleeve,of which,the tee connection tube was made of polyethylene polymer material and the others were made of silicone material.The tee connection tube had a T-shaped structure with two standard connection ports,which was composed of an adapter,a sealing cap,a plug and a sealing ring;the isolation sleeve was in the shape of a cylinder with a raised bottom,which was inserted into the adapter;the stop sleeve was located in the isolation sleeve,with an inverted frustum of a cone at the bottom and a rounded hole in the middle of the inverted frustum.An open ventilator circuit tube was involved in the performance verification of the circuit component developed.In the water seal experiment,sputum aspiration was simulated and the heights of the liquid level drop in the L-shaped tubes were compared after sputum aspiration.In the anti-splash experiment,the infection rates on the surfaces of the sterile hole towels and gloves were calculated.Results Water seal experiment showed after sputum aspiration the open ventilator circuit tube had the liquid level at the L-shaped tube higher significantly than that of the circuit component;the anti-splash experiment indicated sputum aspiration resulted in the occurance of the splashing out of the secretion and 77.5%infection rate by the open ventilator circuit tube,while no splashing out and 0%infection rate by the circuit component developed.Conclusion The novel protective ventilator circuit component behaves well in sealing and anti-splashing,and thus is worthy of clinical application for sputum aspiration.[Chinese Medical Equipment Journal,2025,46(4):113-117]
8.Comparison of differences in dosimetry and treatment efficiency of modified radiotherapy plans after left-sided breast-conserving surgery
Jian-hai LIN ; Jing FENG ; Zhong-hua CHEN ; Zhi-chao FU ; Jie CHEN ; Nan-bao ZHONG
Chinese Medical Equipment Journal 2025;46(4):45-51
Objective To compare the differences in dosimetry and treatment efficiency of three radiotherapy plans after left-sided breast-conserving surgery,including modified intensity-modulated radiation therapy(IMRT),cross-field volume-modulated arc therapy(VMAT)or improved VMAT,so as to provide references for clinical practice.Methods Three radiotherapy plans of modified IMRT,cross-field VMAT and improved VMAT were designed for 12 patients after left-sided-breast-conserving surgery.The modified IMRT with five irradiation fields and the improved VMAT with two arcs were modified by not setting cross-fields while determining the start and end angles with the rays passing through the least lung area.The cross-field VMAT had its start and end angles set based on the cross-fields.The doses to the target areas,peripheral organs at risk,heart and its substructures were evaluated,and dose verification was carried out.The three plans were compared in terms of treatment efficiency and gamma pass rate.SPSS 22.0 was used for statistical analysis.Results All the three plans behaved well in dose distribution.In terms of planning gross tumor volume dosimetry dosimetry,the improved VMAT and modified IMRT gained advantages than others in CI and D50,respectively,with the differences being significant(all P<0.05).In terms of planning target volume dosimetry,the modified IMRT had the V107 and D50 lower than those of the others,with the differences being significant(P<0.05).In terms of the protection of peripheral organs at risk,V5 of the left lung,Dmean of the right lung and Dmean of the healthy breast were lower in the modified IMRT plan than in the other 2 plans,with statistically significant differences(P<0.05);V20,V30,V35 and V40 of the left lung were lower in the modified VMAT plan than in the other 2 plans,with statistically significant differences(P<0.05).In terms of protection of heart and its substructures,the left ventricle V20,V30 and Dmean of the improved VMAT plan behaved better than those of other 2 plans,and the difference was statistically significant(all P<0.05).In terms of treatment efficiency,the cross-field VMAT plan had the lowest MU while highest treatment efficiency;the improved VMAT plan had the MU higher while the treatment efficiency lower than the cross-field VMAT plan;the modified IMRT plan had the highest MU while the lowest gamma pass rate,and the differences in the MUs and gamma pass rates among the three plans were statistically significant(P<0.05).Conclusion Under the same standard conditions,the cross-field VMAT and improved VMAT plans show technical advantages.Though the improved VMAT plan has the treatment efficiency lower than the cross-field VMAT,it decreases the possibility of radiocardiac injury in terms of dosimetry and thus can be used for radiotherapy after left-sided breast-conserving surgery.[Chinese Medical Equipment Journal,2025,46(4):45-51]
9.A Pneumatic Micro-valve with Sandwich Structure Based on Micro-electro-mechanical System
Shao-Jie MA ; Wen-Bo LI ; Yu-Chen ZHU ; Zhi-Rui LI ; Bin ZHAO ; Fei FENG
Chinese Journal of Analytical Chemistry 2025;53(5):758-764
In this study,an ON/OFF type micro-valve with a sandwich(glass-silicon-glass)structure was designed and fabricated based on the micro-electro-mechanical system(MEMS)technique.The deformable membrane of this micro-valve was prepared on the silicon on insulator(SOI)substrate and sealed using Si-Si bonding and anodic bonding methods.The micro-valve had high-temperature stability and was suitable for integration with other gas chromatography components.The deformable membrane with a thickness of 10 μm was processed on the top silicon of the SOI substrate.The flow control of the micro-valve could be achieved by changing the driving pressure applied to the deformable membrane to deform it.Compared with polymer membranes,the deformable membrane prepared on the top layer silicon of SOI had better temperature stability and could be released using the deep reactive ion etching technique after silicon-silicon bonding,avoiding deformation during the preparation process.In addition,due to the small gap between the membrane and the inlet/outlet holes,the dead volume of the microvalve was very small.The test results indicated that the micro-valve achieved flow control and ON/OFF functions with good repeatability.
10.Analysis of Nitrofuran Metabolites in Meat by Solid-Phase Extraction of Porous Organic Polymer Combined with Liquid Chromatography-Tandem Mass Spectrometry
Yao CHEN ; Ying-Jiao DONG ; Jia-Yi LI ; Rui-Jie WANG ; Zhi-Kai HONG ; Guan-Hua WANG
Chinese Journal of Analytical Chemistry 2025;53(5):804-813
In this work,with tris(4-aminophenyl)amine(TAPA)and 1,3,5-tris(4-formylphenyl)benzene(TFPB)as monomers,an imine-type porous organic polymer,TAPA-TFPB,was synthesized using a simple method under the catalysis of acetic acid.The material TAPA-TFPB was used as solid-phase extraction adsorbent and combined with ultra-performance liquid chromatography/quadrupole time-of-flight-tandem mass spectrometry(UHPLC-QTOF-MS)to establish a detection method for four kinds of nitrofuran metabolites(NFMs)residues in meat samples.The parameters of the adsorbent dosage,the pH value and volume of sample,and the type and volume of washing and eluent solvents were optimized,respectively.Under the optimal extraction conditions,low detection limits(0.11-1.60 μg/kg)were achieved for four kinds of NFMs.At three different spiked levels,the intra-day and inter-day precisions(Relative standard deviations)were 2.8% -10.9% and 4.3% -16.2%,respectively,and the spiked recoveries were 72.0% -107.2%.The results showed that the method chould be used for efficient extraction and analysis of trace NFMs residues in meat samples,indicating that TAPA-TFPB was a kind of promising SPE adsorbent.

Result Analysis
Print
Save
E-mail