1.Three-dimensional finite element analysis of molar distalization with clear aligners with different thicknesses and edges
Yanan CHENG ; Jiazhi YU ; Yinchang LIU ; Jie WU ; Tong YU ; Lu WANG ; Xiaoguang LI
Chinese Journal of Tissue Engineering Research 2026;30(2):310-318
BACKGROUND:One of the advantages of clear aligner treatment is molar distalization.However,tooth tilting movement and loss of anterior anchorage may occur during treatment.There are few studies on whether these problems can be improved by selecting clear aligners with different thicknesses and edges to improve the clinical treatment effect.OBJECTIVE:To analyze the control ability of clear aligners with different thickness and edges on the central incisor,lateral incisor,and second molar when pushing the maxillary second molar distally by three-dimensional finite element analysis.METHODS:Three-dimensional finite element analysis models of bilateral maxillary second molar distalization with clear aligner,maxillary dentition,periodontal ligament,and alveolar bone with different thicknesses and margins were established by Mimics,Geomagic Wrap,3-matic and SolidWorks software,respectively.There were 16 combinations of four thicknesses(0.4,0.5,0.625,and 0.75 mm)and four margins(scallop,straight,straight extension 2 mm and straight extension 4 mm).The data were imported into Ansys Workbench software for design and solution.The mean value,peak value and distribution of the periodontal ligament equivalent stress of the second molar,the equivalent stress and the maximum initial displacement of the second molar,and the control ability of each appliance on the second molar,central incisor,and lateral incisor were analyzed.RESULTS AND CONCLUSION:(1)The mean equivalent stress of periodontal ligament of the second molar,the equivalent stress of the second molar and the maximum initial displacement of the second molar increased with the extension of the appliance edge and the increase of the thickness of the appliance in the 16 groups of models.(2)When the thickness of appliances was the same,the maximum equivalent stress of the second molar in the linear appliance group was the highest,and the maximum equivalent stress of the second molar in the linear extended appliance group was greater than that in the scallop appliance group.When the edge of the appliance was the same,the periodontal ligament equivalent stress peak of the second molar increased with the increase of the thickness of the appliance.The equivalent stress distribution in the periodontal ligament of the second molar in the linear extendable appliance group was more uniform than that in the scallop appliance group and the linear appliance group.(3)When the thickness of the appliance was the same,the scallop-shaped appliance had the worst control on the second molar.When the edge of the appliance was the same,with the increase of the thickness of the appliance,the control of the second molar by the linear extender appliance was gradually stronger than that by the linear appliance.The control of the central incisor was stronger and more stable with the linear extended 2 mm appliance,while the control of the lateral incisor was stronger and more stable with the linear appliance.(4)The results showed that when using clear aligners to push molars distally,extending the edge of the appliance could improve the control of the molars and reduce the tilting movement of the teeth.The design of a straight extension margin of 2 mm for the central incisor and a straight edge for the lateral incisor can enhance the control of the anchorage incisor and reduce the labial inclination of the anterior teeth.
2.Three-dimensional finite element analysis of molar distalization with clear aligners with different thicknesses and edges
Yanan CHENG ; Jiazhi YU ; Yinchang LIU ; Jie WU ; Tong YU ; Lu WANG ; Xiaoguang LI
Chinese Journal of Tissue Engineering Research 2026;30(2):310-318
BACKGROUND:One of the advantages of clear aligner treatment is molar distalization.However,tooth tilting movement and loss of anterior anchorage may occur during treatment.There are few studies on whether these problems can be improved by selecting clear aligners with different thicknesses and edges to improve the clinical treatment effect.OBJECTIVE:To analyze the control ability of clear aligners with different thickness and edges on the central incisor,lateral incisor,and second molar when pushing the maxillary second molar distally by three-dimensional finite element analysis.METHODS:Three-dimensional finite element analysis models of bilateral maxillary second molar distalization with clear aligner,maxillary dentition,periodontal ligament,and alveolar bone with different thicknesses and margins were established by Mimics,Geomagic Wrap,3-matic and SolidWorks software,respectively.There were 16 combinations of four thicknesses(0.4,0.5,0.625,and 0.75 mm)and four margins(scallop,straight,straight extension 2 mm and straight extension 4 mm).The data were imported into Ansys Workbench software for design and solution.The mean value,peak value and distribution of the periodontal ligament equivalent stress of the second molar,the equivalent stress and the maximum initial displacement of the second molar,and the control ability of each appliance on the second molar,central incisor,and lateral incisor were analyzed.RESULTS AND CONCLUSION:(1)The mean equivalent stress of periodontal ligament of the second molar,the equivalent stress of the second molar and the maximum initial displacement of the second molar increased with the extension of the appliance edge and the increase of the thickness of the appliance in the 16 groups of models.(2)When the thickness of appliances was the same,the maximum equivalent stress of the second molar in the linear appliance group was the highest,and the maximum equivalent stress of the second molar in the linear extended appliance group was greater than that in the scallop appliance group.When the edge of the appliance was the same,the periodontal ligament equivalent stress peak of the second molar increased with the increase of the thickness of the appliance.The equivalent stress distribution in the periodontal ligament of the second molar in the linear extendable appliance group was more uniform than that in the scallop appliance group and the linear appliance group.(3)When the thickness of the appliance was the same,the scallop-shaped appliance had the worst control on the second molar.When the edge of the appliance was the same,with the increase of the thickness of the appliance,the control of the second molar by the linear extender appliance was gradually stronger than that by the linear appliance.The control of the central incisor was stronger and more stable with the linear extended 2 mm appliance,while the control of the lateral incisor was stronger and more stable with the linear appliance.(4)The results showed that when using clear aligners to push molars distally,extending the edge of the appliance could improve the control of the molars and reduce the tilting movement of the teeth.The design of a straight extension margin of 2 mm for the central incisor and a straight edge for the lateral incisor can enhance the control of the anchorage incisor and reduce the labial inclination of the anterior teeth.
3.Development and Validation of a High-Performance Liquid Chromatography-Tandem Mass Spectrometry Method for Detecting Adrenocortical Hormones and Establishment of Age-Stratified Reference Intervals in Reproductive-Aged Women from Guangxi, China
Yixuan LIU ; Tingwei JIN ; Yushuang WEI ; Xuelian QIN ; Siyu DENG ; Jie ZHENG ; Boteng YAN ; Yuanyuan NONG ; Yu YE ; Shengzhu HUANG ; Yu LONG ; Jianmin LI ; Ganqin WANG ; Pei HUANG ; Jinghang JIANG ; Fan WU ; Zengnan MO ; Yonghua JIANG
Annals of Laboratory Medicine 2026;46(2):146-154
Background:
Adrenocortical hormones, particularly 11-oxygenated androgens, are pivotal in female reproductive health and fertility. Standardized detection kits and population-specific reference intervals are lacking in China, hindering related clinical applications.
Methods:
A HPLC-tandem mass spectrometry (HPLC-MS/MS) pipeline was developed, rigorously validated, and applied to simultaneously quantify corticosterone, cortisone, cortisol, 18-OH cortisol, androstenedione (A4), 11β-hydroxyandrostenedione (11-OH A4), dehydroepiandrosterone, and dehydroepiandrosterone sulfate in serum samples from 455 reproductive-aged women (18–45 yrs) in Guangxi, China. Age-dependent concentration trends were analyzed, and reference intervals stratified by age (2.5th to 97.5th percentiles) were established. Correlations with body-composition metrics, ethnicity, and the menstrual cycle were investigated.
Results:
The HPLC-MS/MS method demonstrated high precision (intra- and inter-assay CVs < 15%), accuracy, and sensitivity. All eight hormones exhibited significant age-related declines (P < 0.001 for seven hormones; P = 0.001 for 11-OH A4). Notably, 11-OH A4 levels were significantly lower in the 35–45-yr (3.05 nmol/L) and 25–34-yr (3.09 nmol/L) age groups than in the 18–24-yr (3.57 nmol/L) age group, whereas no significant difference was observed between the 35–45-yr and 25–34-yr age groups. Weak negative correlations were observed between the body mass index and corticosterone and cortisone levels, whereas ethnicity and the menstrual cycle showed no significant associations with hormone levels.
Conclusions
We developed an HPLC-MS/MS-based method for simultaneously quantifying eight adrenocortical hormones, including 11-OH A4, and defined age-specific reference intervals for reproductive-aged Chinese women. These findings advance the clinical utility of adrenocortical hormones in diagnosing and managing reproductive disorders.
4.Dynamic Interactions Between Hemispheres Reveal a Compensatory Pathway for Motor Recovery in Moderate-to-Severe Subcortical Stroke
Huaxin FAN ; Hewei WANG ; Zhengxu LIAN ; Qiurong YU ; Xinran WU ; Nanyu KUANG ; Benjamin BECKER ; Jianfeng FENG ; Mingxia FAN ; Lili SONG ; Limin SUN ; Jie ZHANG ; Craig S. ANDERSON
Journal of Stroke 2026;28(1):97-114
Background:
and Purpose Therapeutic target selection in noninvasive brain stimulation for poststroke motor recovery typically relies on the interhemispheric inhibition model, which is effective for mildly affected patients but offers limited benefits for severely affected individuals. The mechanisms governing recovery from moderate-to-severe stroke remain poorly understood, which hinders the development of targeted interventions.
Methods:
We analyzed resting-state functional magnetic resonance imaging data from patients with unilateral subcortical stroke and moderate-to-severe upper limb deficits, both pre- and postintervention, along with data from healthy controls. We developed a novel dynamic lag analysis method for identifying recovery-related homotopic sensorimotor regions with altered interhemispheric interactions. To further uncover the global reorganization pathway, we developed dynamic lateralization approaches to detect large-scale functional connectivity (FC) alterations associated with the identified regions in transient lateralization states.
Results:
Dynamic time-lag analysis revealed significantly reduced synchronized states in the homotopic dorsal premotor cortex (PMd) post-intervention compared with pre-intervention, which correlated with motor recovery. Further dynamic lateralization analysis revealed a prolonged segregation state in patients, characterized by weakened interhemispheric and strengthened intrahemispheric interactions. In this state, patients showed decreased FC in the ipsilesional PMd and increased FC in the contralesional PMd with bilateral subcortical networks. These recoveryrelated alterations were absent in the traditional static analysis.
Conclusions
Dynamic analyses targeting interhemispheric interactions are valuable for understanding neural reorganization after stroke. The diminished interactions between the homotopic PMd indicate a compensatory mechanism. Importantly, a state-dependent compensatory pathway was identified, wherein the contralesional PMd assumes the functions of the ipsilesional PMd through enhanced interactions with subcortical structures, potentially guiding more effective interventions.
5.Analysis of changes and influencing factors of activation rate of peripheral blood monocytes after liver transplantation
Yu GONG ; Hui WU ; Jie ZHU ; Ting WANG ; Xiaowu HUANG
Chinese Journal of Clinical Medicine 2025;32(1):101-107
Objective To analyze the effect of the activation rate of peripheral blood monocytes on the recovery of patients after liver transplantation and to initially explore the possible influencing factors for differences in monocyte activation rates. Methods A total of 139 patients who underwent orthotopic liver transplantation from September 2020 to June 2023 at Department of Liver Surgery and Transplantation of Zhongshan Hospital, Fudan University were selected. The proportion of CD14+HLA-DR+ monocytes in peripheral blood was defined as the monocyte activation rate. The difference in monocyte activation rates between postoperative day 7 (POD7) and postoperative day 1 (POD1) was calculated as Δ, and patients were divided into Δ>0 group (n=73) and Δ<0 group (n=66). The two groups were compared in terms of complete blood count, liver and kidney function, coagulation indicators, infection indicators, ICU length of stay, total length of hospitalization, and 90-day mortality. Changes in the proportions of different monocytes subsets (Mo0, Mo1, Mo2, and Mo3) and HLA-DR expression in peripheral blood on POD1 and POD7 were detected using flow cytometry. Results The ICU length of stay in the Δ<0 group was significantly longer than that in the Δ>0 group (18[12, 26] days vs 14[10, 20.5] days, P=0.018). On POD1, the proportion of Mo0 in the Δ>0 group was significantly lower than that in the Δ<0 group (P<0.05); on POD7, the proportion of Mo0 in the Δ>0 group was significantly lower than that in the Δ<0 group (P<0.001), while the proportions of Mo1, Mo2, and Mo3 were significantly higher than those in the Δ<0 group (P<0.001). Compared to POD1, the HLA-DR expression level of Mo0 in peripheral blood of patients with liver transplantation significantly decreased on POD7 (P<0.01), while there was no significant difference in HLA-DR expression levels of Mo1, Mo2, and Mo3. Conclusions Increased proportion of Mo0 (CD14lowCD16−HLA-DRlow) among peripheral blood monocyte subsets may be one of the influencing factors for the differences in monocyte activation rates in patients with liver transplantation. The difference in monocyte activation rate can serve as a new clinical indicator for assessing changes in the immune status and postoperative recovery of patients with liver transplantation.
6.Current situation and influencing factors of blood pressure measurement cognition and behavior in community patients
Jie YU ; Yawei ZOU ; Xi CHEN ; Junfeng ZHAO ; Yejing WANG
Journal of Public Health and Preventive Medicine 2025;36(1):83-87
Objective To investigate the cognition level and behavior compliance of blood pressure measurement in community residents and analyze the related influencing factors, and to provide evidence for community health management and blood pressure control. Methods A questionnaire survey was conducted to investigate 4470 community patients. Questionnaires included basic personal information,blood pressure measurement cognition, and blood pressure measurement behavior related issues. SPSS 19.0 was used to analyze the basic information, blood pressure measurement cognition, and pressure measurement behavior of the survey subjects. Logistic regression was performed to analyze relevant factors affecting blood pressure measurement cognition and behavior compliance. Results The overall cognitive compliance rate for blood pressure measurement among the visiting community patients was 31.52%. Age, education level, and chronic disease had a statistically significant impact on the cognitive knowledge (P<0.05). The overall behavior compliance rate of blood pressure measurement among the community patients was 23.69%. The cognition, age and education had a statistically significant impact on the overall behavior compliance rate of blood pressure measurement (P<0.05). Conclusion The cognitive level and standardized behavior of blood pressure measurement of community patients need to be improved. More attention should be paid to the elderly, low education level residents and community residents without chronic diseases, to promote community residents to form correct and standardized behavior of blood pressure measurement through health education.
7.Modified Ditan Tang Regulates Biorhythm-related Genes in Rat Model of Non-alcoholic Fatty Liver Disease
Zhiwen PANG ; Yu LIU ; Nan SONG ; Jie WANG ; Jingxuan ZHU ; Zhen HUA ; Yupeng PEI ; Qun WANG
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(6):115-124
ObjectiveTo investigate the effects of modified Ditan tang on genes related to the transcription-translation feedback loop (TTFL) of biorhythm in the rat model of non-alcoholic fatty liver disease (NAFLD) and its mechanism for prevention and treatment of NAFLD. MethodsSixty-five healthy SPF male SD rats were randomly assigned into blank (n=20), model (n=15), and low-, medium-, and high-dose (2.68, 5.36, and 10.72 g·kg-1·d-1, respectively) modified Ditan tang (n=10) groups. Other groups except the blank group were fed a high-fat diet for 12 weeks. The modified Ditan tang groups were treated with the decoction at corresponding doses by gavage, and the blank and model groups were treated with an equal volume of normal saline from the 9th week for 4 weeks. The levels of triglyceride (TG), total cholesterol (TC), low-density lipoprotein cholesterol (LDL-C), high-density lipoprotein cholesterol (HDL-C), aspartate aminotransferase (AST), and alanine aminotransferase (ALT) in the serum were measured by an automatic biochemical analyzer. TG and non-esterified fatty acid (NEFA) assay kits were used to measure the levels of TG and NEFA in the liver. The pathological changes in the hypothalamus and liver were observed by hematoxylin-eosin staining, and the lipid deposition in the liver was observed by oil red O staining. The levels of brain-muscle ARNT-like protein 1 (BMAL1/ARNTL) in the hypothalamus and liver were determined by immunohistochemical staining. The mRNA and protein levels of BMAL1, circadian locomotor output cycles kaput (CLOCK), period circadian clock 2 (PER2), and cryptochrome1 (Cry1) in the hypothalamus and liver were determined by Real-time PCR and Western blot, respectively. ResultsCompared with the blank group, the model group showed elevated levels of TG, TC, LDL-C, AST, and ALT (P<0.01) and a lowered level of HDL-C (P<0.05) in the serum, elevated levels of TG and NEFA in the liver (P<0.01), pyknosis and deep staining of hypothalamic neuron cells, and a large number of vacuoles in the brain area. In addition, the model group showed lipid deposition in the liver, up-regulated mRNA and protein levels of CLOCK and BMAL1 (P<0.01), and down-regulated mRNA and protein levels of Cry1 and PER2 (P<0.01) in the hypothalamus and liver. Compared with the model group, all the three modified Ditan tang groups showed lowered levels of TG, TC, LDL-C, ALT, and AST (P<0.05, P<0.01) and an elevated level of HDL-C (P<0.05) in the serum, and lowered levels of TG and NEFA (P<0.05, P<0.01) in the liver. Furthermore, the three groups showed alleviated pyknosis and deep staining of hypothalamic neuron cells, reduced lipid deposition in the liver, down-regulated mRNA and protein levels of CLOCK and BMAL1 (P<0.05, P<0.01), and up-regulated mRNA and protein levels of Cry1 and PER2 (P<0.05, P<0.01) in the hypothalamus and liver. ConclusionModified Ditan tang can reduce lipid deposition in the liver and regulate the expression of CLOCK, BMAL1, Cry1, and PER2 in the TTFL of NAFLD rats.
8.Does 10-Year Atherosclerotic Cardiovascular Disease Risk Predict Incident Diabetic Nephropathy and Retinopathy in Patients with Type 2 Diabetes Mellitus? Results from Two Prospective Cohort Studies in Southern China
Jiaheng CHEN ; Yu Ting LI ; Zimin NIU ; Zhanpeng HE ; Yao Jie XIE ; Jose HERNANDEZ ; Wenyong HUANG ; Harry H.X. WANG ;
Diabetes & Metabolism Journal 2025;49(2):298-310
Background:
Diabetic macrovascular and microvascular complications often coexist and may share similar risk factors and pathological pathways. We aimed to investigate whether 10-year atherosclerotic cardiovascular disease (ASCVD) risk, which is commonly assessed in diabetes management, can predict incident diabetic nephropathy (DN) and retinopathy (DR) in patients with type 2 diabetes mellitus (T2DM).
Methods:
This prospective cohort study enrolled 2,891 patients with clinically diagnosed T2DM who were free of ASCVD, nephropathy, or retinopathy at baseline in the Guangzhou (2017–2022) and Shaoguan (2019–2021) Diabetic Eye Study in southern China. The 10-year ASCVD risk was calculated by the Prediction for ASCVD Risk in China (China-PAR) equations. Multivariable- adjusted Cox proportional hazard models were developed to estimate hazard ratios (HRs) with 95% confidence intervals (CIs). The area under the receiver operating characteristic curve (AUC) was used to evaluate predictive capability.
Results:
During follow-up, a total of 171 cases of DN and 532 cases of DR were documented. Each 1% increment in 10-year ASCVD risk was associated with increased risk of DN (pooled HR, 1.122; 95% CI, 1.094 to 1.150) but not DR (pooled HR, 0.996; 95% CI, 0.979 to 1.013). The model demonstrated acceptable performance in predicting new-onset DN (pooled AUC, 0.670; 95% CI, 0.628 to 0.715). These results were consistent across cohorts and subgroups, with the association appearing to be more pronounced in women.
Conclusion
Ten-year ASCVD risk predicts incident DN but not DR in our study population with T2DM. Regular monitoring of ASCVD risk in routine diabetes practice may add to the ability to enhance population-based prevention for both macrovascular and microvascular diseases, particularly among women.
9.A new classification of atlas fracture based on computed tomography: reliability, reproducibility, and preliminary clinical significance
Yun-lin CHEN ; Wei-yu JIANG ; Wen-jie LU ; Xu-dong HU ; Yang WANG ; Wei-hu MA
Asian Spine Journal 2025;19(1):3-9
Methods:
Seventy-five patients with atlas fracture were included from January 2015 to December 2020. Based on the anatomy of the fracture line, atlas fractures were divided into three types. Each type was divided into two subtypes according to the fracture displacement. Unweighted Cohen kappa coefficients were applied to evaluate the reliability and reproducibility.
Results:
According to the new classification, 17 cases of type A1, 12 of type A2, seven of type B1, 13 of type B2, 12 of type C1, and 14 of type C2 were identified. The K-values of the interobserver and intraobserver reliability were 0.846 and 0.912, respectively, for the new classification. The K-values of interobserver reliability for types A, B, and C were 0.843, 0.799, and 0.898, respectively. The K-values of intraobserver reliability for types A, B, and C were 0.888, 0.910, and 0.935, respectively. The mean K-values of the interobserver and intraobserver reliability for subtypes were 0.687 and 0.829, respectively.
Conclusions
The new classification of atlas fractures can cover nearly all atlas fractures. This system is the first to evaluate the severity of fractures based on the C1 articular facet and fracture displacement and strengthen the anatomy ring of the atlas. It is concise, easy to remember, reliable, and reproducible.
10.Study on Brain Functional Network Characteristics of Parkinson’s Disease Patients Based on Beta Burst Period
Yu-Jie HAO ; Shuo YANG ; Shuo LIU ; Xu LOU ; Lei WANG
Progress in Biochemistry and Biophysics 2025;52(5):1279-1289
ObjectiveThe central symptom of Parkinson’s disease (PD) is impaired motor function. Beta-band electrical activity in the motor network of the basal ganglia is closely related to motor function. In this study, we combined scalp electroencephalography (EEG), brain functional network, and clinical scales to investigate the effects of beta burst-period neural electrical activity on brain functional network characteristics, which may serve as a reference for clinical diagnosis and treatment. MethodsThirteen PD patients were included in the PD group, and 13 healthy subjects were included in the healthy control group. Resting-state EEG data were collected from both groups, and beta burst and non-burst periods were extracted. A phase synchronization network was constructed using weighted phase lag indices, and the topological feature parameters of phase synchronization network were compared between the two groups across different periods and four frequency bands. Additionally, the correlation between changes in network characteristics and clinical symptoms was analyzed. ResultsDuring the beta burst period, the topological characteristic parameters of phase synchronization network in all four frequency bands were significantly higher in PD patients compared to healthy controls. The average clustering coefficient of the phase synchronization network in the beta band during the beta burst period was negatively correlated with UPDRS-III scores. In the low gamma band during the non-burst period, the average clustering coefficient of phase synchronization network was positively correlated with UPDRS and UPDRS-III scores, while UPDRS-III scores were positively correlated with global efficiency and average degree. ConclusionThe brain functional network features of PD patients were significantly enhanced during the beta burst period. Moreover, the beta-band brain functional network characteristics during the beta burst period were negatively correlated with clinical scale scores, whereas low gamma-band functional network features during the non-burst period were positively correlated with clinical scale scores. These findings indicate that motor function impairment in PD patients is associated with the beta burst period. This study provides valuable insights for the diagnosis of PD.


Result Analysis
Print