1.Impact of suture configuration and fixation type on biomechanical strength of rotator cuff repair:A factorial design study
Yinzhe CUI ; Zheng YAN ; Jia MA ; Zhefeng JIN ; Jiawen ZHAN ; Minshan FENG ; Guangwei LIU ; Jie YU ; Xu WEI ; Jiangtao SI ; Minghui ZHUANG ; Tao HAN ; Jianguo LI ; ZHANGKAIRUI ; Liguo ZHU
Chinese Journal of Sports Medicine 2025;44(9):729-737
Objective To explore the impact of suture configuration and fixation type on the biome-chanical strength of rotator cuff repair,using a factorial design study.Methods Sixteen fresh-frozen porcine shoulder samples were randomized into an anchorless double-row suture bridge transosseous su-tures(DS)group,an anchored double-row suture bridge transosseous-equivalent(DE)group,an an-chorless X-BOX construct transosseous sutures(XS)group,and an anchored X-BOX construct transos-seous-equivalent(XE)group,each of four,according to suture configuration(double-row suture bridge,traditional X-BOX construct)and fixation type(suture anchors,transosseous sutures).Then,their fatigue resistance(first-cycle excursion,gap length difference ratio,and the percentage of ex-posed footprints)and the failure strength(the maximum failure load and the re-tear type)were mea-sured using a biomechanical material testing machine.Results Different suture configurations affected failure strength(F=39.559,P<0.001),with the double-row suture bridge groups(693.07±58.35 N,746.76±138.57 N)showing significantly higher failure strength,compared to the traditional X-BOX groups(462.90±18.91 N,421.43±90.76 N).However,the fixation type did not significantly im-pact failure strength(F=1.161,P=0.302).Moreover,the suture configuration influenced the gap differ-ence ratio(F=7.781,P=0.016),but had no significant correlation with other fatigue resistance indica-tors(P>0.05).Meanwhile,failure strength and fatigue resistance were not correlated with fixation type,and the interaction between suture and fixation type(P>0.05).The incidence of failure types for the four suture configurations was as follows:Type I tendon tear:XS>XE>DS=DE;type II tendon tear:DS>XE>XS=DE;fixing material-related failure:DE>DS=XE=XS.Conclusion The failure strength and gap formation ratio in rotator cuff repair under fatigue loading are influenced by suture configuration,whereas no significant association has been observed with respect to fixation method,whether using transosseous sutures or suture anchors.
2.Impact of suture configuration and fixation type on biomechanical strength of rotator cuff repair:A factorial design study
Yinzhe CUI ; Zheng YAN ; Jia MA ; Zhefeng JIN ; Jiawen ZHAN ; Minshan FENG ; Guangwei LIU ; Jie YU ; Xu WEI ; Jiangtao SI ; Minghui ZHUANG ; Tao HAN ; Jianguo LI ; ZHANGKAIRUI ; Liguo ZHU
Chinese Journal of Sports Medicine 2025;44(9):729-737
Objective To explore the impact of suture configuration and fixation type on the biome-chanical strength of rotator cuff repair,using a factorial design study.Methods Sixteen fresh-frozen porcine shoulder samples were randomized into an anchorless double-row suture bridge transosseous su-tures(DS)group,an anchored double-row suture bridge transosseous-equivalent(DE)group,an an-chorless X-BOX construct transosseous sutures(XS)group,and an anchored X-BOX construct transos-seous-equivalent(XE)group,each of four,according to suture configuration(double-row suture bridge,traditional X-BOX construct)and fixation type(suture anchors,transosseous sutures).Then,their fatigue resistance(first-cycle excursion,gap length difference ratio,and the percentage of ex-posed footprints)and the failure strength(the maximum failure load and the re-tear type)were mea-sured using a biomechanical material testing machine.Results Different suture configurations affected failure strength(F=39.559,P<0.001),with the double-row suture bridge groups(693.07±58.35 N,746.76±138.57 N)showing significantly higher failure strength,compared to the traditional X-BOX groups(462.90±18.91 N,421.43±90.76 N).However,the fixation type did not significantly im-pact failure strength(F=1.161,P=0.302).Moreover,the suture configuration influenced the gap differ-ence ratio(F=7.781,P=0.016),but had no significant correlation with other fatigue resistance indica-tors(P>0.05).Meanwhile,failure strength and fatigue resistance were not correlated with fixation type,and the interaction between suture and fixation type(P>0.05).The incidence of failure types for the four suture configurations was as follows:Type I tendon tear:XS>XE>DS=DE;type II tendon tear:DS>XE>XS=DE;fixing material-related failure:DE>DS=XE=XS.Conclusion The failure strength and gap formation ratio in rotator cuff repair under fatigue loading are influenced by suture configuration,whereas no significant association has been observed with respect to fixation method,whether using transosseous sutures or suture anchors.
3.The correlation between occupational burnout and sleep quality among steelworkers
Xiaolei LUO ; Xiuyun CUI ; Mingfeng DING ; Jiawen ZHANG ; Jingwen JIANG ; Gaiyun LI ; Yilun LI ; Jingyi LI ; Ziyuan MA ; Yichen MA ; Xuemei HAN
China Occupational Medicine 2023;50(5):566-570
{L-End}Objective To analyze the correlation between occupational burnout and sleep quality among steelworkers. {L-End}Methods A total of 11 491 steelworkers from a large steel enterprise in Gansu Province were selected as the research subjects using convenient sampling method. The Burnout Questionnaire and the Pittsburgh Sleep Quality Index Scale were used to investigate their occupational burnout and sleep quality. Hierarchical regression analysis was used to analyze the effects of occupational burnout on the sleep quality. {L-End}Results The detection rate of occupational burnout and sleep disorder were 50.4% and 39.0%, respectively. There was a positive correlation between the level of occupational burnout and the total score of sleep quality (Spearman correlation coefficient=0.454, P<0.05). The results of hierarchical regression analysis, adjusting for confounding factors such as gender, age, marital status, education level, alcohol consumption, exercise, weekly working hours, seniority, work shift, noise exposure, dust exposure, and high-temperature work, showed that the score of occupational burnout was positively related to the score of sleep quality(P<0.01), explaining 16.0% of the variance in the score of sleep quality among these steelworkers. {L-End}Conclusion The detection rate of occupational burnout and sleep disorders are relatively high among the steelworkers in this enterprise. Higher levels of occupational burnout are associated with poorer sleep quality. Alleviating occupational burnout among steelworkers may contribute to improving their sleep quality.
4. Advances in the research and clinical application of the third generation EGFR TKIs in the treatment of non-small cell lung cancer
Kexin ZHANG ; Wenjing JIA ; Jiawen CUI ; Luyao AO ; Fang ZHOU ; Guangji WANG ; Jiali LIU
Chinese Journal of Clinical Pharmacology and Therapeutics 2022;27(9):1016-1030
Epidermal growth factor receptor (EGFR) is one of the most common targeted oncogenes in non-small cell lung cancer (NSCLC). The third-generation EGFR tyrosine kinase inhibitors (TKIs) have become the standard treatment for metastatic or recurrent NSCLC patients harboring EGFR positive or concomitant T790M mutations. However, the inevitable emergence of acquired resistance markedly limits their prolonged clinical benefits, although the third-generation EGFR TKIs have shown potent clinical outcomes in initial several months. This paper firstly reviews the characEpidermal growth factor receptor (EGFR) is one of the most common targeted oncogenes in non-small cell lung cancer (NSCLC). The third-generation EGFR tyrosine kinase inhibitors (TKIs) have become the standard treatment for metastatic or recurrent NSCLC patients harboring EGFR positive or concomitant T790M mutations. However, the inevitable emergence of acquired resistance markedly limits their prolonged clinical benefits, although the third-generation EGFR TKIs have shown potent clinical outcomes in initial several months. This paper firstly reviews the characteristics and clinical efficacy of the third-generation EGFR TKIs in the market or in the clinical development. Then this article summarizes the detailed mechanisms behind the acquired drug resistance of third-generation EGFR TKIs,and further expounds the current treatment strategies to overcome the resistance. Collectively, this review could provide more information for the development and clinical application of drugs targeting EGFR.
5.One case of primary malignant lymphoma of the maxillary sinus.
Yingjun SHAN ; Jiawen CUI ; Jiong ZHENG
Journal of Clinical Otorhinolaryngology Head and Neck Surgery 2014;28(2):137-138
Malignant lymphoma of the maxillary sinus is very rare. A case of diffuse large B-cell lymphoma (DLBCL) of the left maxillary sinus is presented here. A 59-year-old man came to our hospital complaining of swelling under the left lower eyelid without any other symptoms. Imaging examination including CT and MRI detected a tumor in the left maxillary sinus. The tumor was invasive into left orbit. The biopsy revealed a diffuse large B-cell lymphoma. The tumor cells were positive to CD20, CD79a, CD45. In conclusion, a very rare case of DLBCL of the maxillary sinus was reported.
Humans
;
Lymphoma, Large B-Cell, Diffuse
;
Male
;
Maxillary Sinus
;
Middle Aged
;
Paranasal Sinus Neoplasms

Result Analysis
Print
Save
E-mail