1.Insomnia and quality of life as chain mediators between negative life events and depression severity in adolescents with depressive disorders
Xu ZHANG ; Lewei LIU ; Jiawei WANG ; Feng GENG ; Daming MO ; Changhao CHEN ; Zhiwei LIU ; Xiangwang WEN ; Xiangfen LUO ; Huanzhong LIU
Acta Universitatis Medicinalis Anhui 2026;61(1):163-168
ObjectiveTo explore the relationship between negative life events and depression severity in adolescent patients with depressive disorder, as well as the chain mediating role of insomnia symptoms and quality of life. Methods374 outpatient patients and hospitalized patients with adolescent depressive disorders were enrolled. The Adolescent Life Event Scale (ASLEC), the Insomnia Severity Index (ISI), the World Health Organization Quality of Life Questionnaire Short Form (WHOQOL-BREF), and the Center for Epidemiology Depression Scale (CES-D) were used to evaluate the negative life event situation, insomnia symptoms, quality of life level and depression severity of the subjects, respectively. In addition, the PROCESS 4.0 macroprogram was used to analyze the chain mediating effect of insomnia symptoms and quality of life between negative life events and depression severity in patients with adolescent depressive disorder. ResultsThe results of correlation analysis showed that there was a significant correlation between negative life events and insomnia symptoms, quality of life, and depression severity (all P<0.05). In addition, the results of chain mediation showed that negative life events had a significant direct effect on depression severity, with an effect size of 0.12 (P<0.001). Insomnia symptoms and quality of life played a mediating role in the relationship between negative life events and depression severity in patients with adolescent depressive disorders, with indirect effect sizes of 0.062 (95%CI: 0.040-0.087) and 0.091 (95%CI: 0.059-0.123), respectively. It could also play a chain mediation role, and the effect size was 0.039 (95%CI: 0.024-0.057). ConclusionNegative life events experienced by patients with adolescent depressive disorder not only directly affect the severity of depressive symptoms, but may also indirectly exacerbate depression through insomnia symptoms and quality of life.
2.Time-series analysis of daily temperature, atmospheric pressure, and pre-hospital cardiovascular and cerebrovascular disease emergencies in Yantai, Shandong Province, 2016–2022
Mingshun WU ; Qing ZHANG ; Liang CHANG ; Lan LI ; Suqiu YANG ; Jiarong LI ; Xinhui YU ; Linlin LI ; Jiawei FENG ; Tieying NI
Journal of Environmental and Occupational Medicine 2026;43(4):458-466
Background Meteorological factors are among the key extrinsic triggers for the onset and exacerbation of cardiovascular and cerebrovascular diseases (CVD). Against the backdrop of sustained global warming, elucidating the impact of ambient temperature and atmospheric pressure on CVD, especially on pre-hospital CVD emergent events, has become imperative for evidence-based prevention and emergency preparedness. Objective To quantify the temporal trends of daily mean temperature and atmospheric pressure and their associations with pre-hospital CVD emergent events in Yantai, and to explore effect modification by demographic subgroups and geographic areas, thereby providing an empirical basis for the rational allocation of emergency medical resources. Methods Pre-hospital CVD emergency data from January 1, 2016 to December 31, 2022 were selected from the Yantai 120 Emergency Medical Command System. Synchronous meteorological factors and environmental pollutant data were obtained from the websites of the National Oceanic and Atmospheric Administration and the National Centers for Environmental Information of the United States. Time-series analysis combined with distributed lag non-linear model was used to analyze the association between daily temperature, atmospheric pressure, and pre-hospital CVD emergencies. Average annual percentage changes (AAPC) were calculated using Joinpoint (version 5.2.0.0) to reflect temporal trends. Spearman correlation analysis was employed to screen variables with low collinearity for inclusion in the multi-pollutant adjusted models. Results From 2016 to 2022, a total of
3.Mechanism of "olfactory three needles" in regulating microglia and promoting remyelination in vascular dementia rats.
Le LI ; Qiang WANG ; Junyang LIU ; Weijia ZHAO ; Jiawei ZENG ; Bingbing ZHANG ; Ruirui MAO ; Weixing FENG ; Jie LI
Chinese Acupuncture & Moxibustion 2025;45(4):473-481
OBJECTIVE:
To observe the effects of "olfactory three needles" on cognition, learning and memory abilities, as well as hippocampal microglia (MG) phagocytic activity in vascular dementia (VD) rats, and explore the mechanisms of acupuncture in regulating MG activation and improving remyelination, so as to ameliorate VD.
METHODS:
Among 38 SD rats meeting experimental requirements, 9 rats were randomly assigned to a sham-operation group, and the remaining rats underwent permanent bilateral common carotid artery ligation to establish VD model. Eighteen successfully modeled rats were randomly divided into a model group and an electroacupuncture (EA) group, with 9 rats in each one. In the EA group, EA was performed at "olfactory three needles" ("Yintang" [GV24+] and bilateral "Yingxiang" [LI20]), at disperse-dense wave, the frequency of 2 Hz/15 Hz and the current intensity of 1 mA, for 15 min per intervention, once daily. One course was composed of 7 days, and 2 courses were required, with the interval of 2 days. The novel object recognition test was employed to assess the cognition of rats, and the Morris water maze was adopted to observe learning and memory abilities. Luxol fast blue (LFB) staining was performed to evaluate myelin sheath loss in the hippocampus, the Western blot was used to detect the protein expression of triggering receptor expressed on myeloid cells-2 (TREM2) and proteolipid protein (PLP) in the hippocampus; and the immunofluorescence staining was used to detect the positive expression of PLP, sex determining region Y-box 10 (SOX10), ionized calcium binding adaptor molecule 1 (Iba1)+ TREM2+ and Iba1+ lysosome-associated membrane protein 1 (LAMP1)+ in the hippocampus.
RESULTS:
Compared with the sham-operation group, the rats in the model group exhibited the prolonged escape latency on day 3 and 4 (P<0.05, P<0.01), the increase of the total distance traveling (P<0.01) and the decrease of the recognition index (RI) and platform crossing frequency (P<0.01). Compared with the model group, the rats in the EA group showed the shortened escape latency on day 3 and 4 (P<0.05), the decrease of total distance traveling (P<0.01) and the increase of RI and platform crossing frequency (P<0.05, P<0.01). When compared with the sham-operation group, the rats of the model group presented uneven staining, sparse arrangement of myelin sheath fibers, unclear contours, and prominent vacuole-like changes in the hippocampal CA1 region. When compared with the model group, the EA group showed more dense staining, the increase of myelin sheath fibers with more orderly alignment, and fewer vacuolar changes in the hippocampal CA1 region. Compared with the sham-operation group, the model group exhibited the increase of TREM2 protein expression and the decrease of PLP protein expression in the hippocampus (P<0.01), whereas the EA group showed the up-regulation of TREM2 and PLP protein expression when compared with the model group (P<0.01, P<0.05). The positive expression of the hippocampal PLP, SOX10, and Iba1+LAMP1+ in the model group was reduced in comparison with the sham-operation group (P<0.05, P<0.01), and the positive expression of Iba1+ TREM2+ was elevated (P<0.05). In the EA group, the positive expression of PLP, SOX10, Iba1+TREM2+, and Iba1+ LAMP1+ was higher compared with that in the model group (P<0.05, P<0.01).
CONCLUSION
"Olfactory three needles" can improve the learning and memory, and cognitive functions of VD rats, and its mechanism may be associated with the up-regulation of TREM2 and LAMP1 to adjust MG phagocytic activity and intracellular degradation, and promote remyelination.
Animals
;
Dementia, Vascular/metabolism*
;
Rats
;
Rats, Sprague-Dawley
;
Microglia/metabolism*
;
Male
;
Acupuncture Therapy/instrumentation*
;
Acupuncture Points
;
Humans
;
Remyelination
;
Memory
;
Hippocampus/cytology*
;
Cognition
;
Electroacupuncture
;
Needles
4.Acupoint thread-embedding therapy of regulating governor vessel, dispersing lung, and suppressing reflux for gastroesophageal reflux cough: a randomized controlled trial.
Mingjie TANG ; Wen LU ; Xiaoni ZHANG ; Jiawei GAO ; Xinchang WEI ; Jin LU ; Jia ZHU ; Yulu FENG ; Lejing JIAO ; Xiaofang XIA ; Zhi ZHOU ; Zhaoming CHEN
Chinese Acupuncture & Moxibustion 2025;45(8):1047-1052
OBJECTIVE:
To observe the clinical efficacy of acupoint thread-embedding therapy of regulating governor vessel, dispersing lung, and suppressing reflux for gastroesophageal reflux cough (GERC).
METHODS:
A total of 120 GERC patients were randomly assigned to an observation group (60 cases, 1 case dropped out) and a control group (60 cases, 1 case was eliminated). The observation group received acupoint thread-embedding treatment at positive response points of governor vessel. If no such points were detected, the following acupoints were used: Dazhui (GV14), Fenghu (Extra), Shendao (GV11), Lingtai (GV10), and Zhiyang (GV9). Treatment was administered once every two weeks. The control group received oral rabeprazole enteric capsules at 20 mg twice daily. All the treatment was given for 6 weeks. Clinical outcomes were assessed using cough symptom score, reflux disease questionnaire (RDQ) score, and Leicester cough questionnaire (LCQ) score before and after treatment in the two groups. Clinical efficacy was also compared between the two groups.
RESULTS:
After treatment, both groups showed decreased cough symptom scores and the each item scores and total scores of RDQ (P<0.001), and increased LCQ scores (P<0.001) compare with those before treatment. The observation group exhibited lower cough symptom score and chest pain, reflux and total score of RDQ, and higher LCQ score compared to those in the control group (P<0.05). The total effective rate in the observation group was 94.9% (56/59), which was higher than 84.7% (50/59) in the control group (P<0.05).
CONCLUSION
Acupoint thread-embedding therapy of regulating governor vessel, dispersing lung, and suppressing reflux could effectively alleviate cough and reflux symptoms in patients with GERC and improve their quality of life.
Humans
;
Acupuncture Points
;
Gastroesophageal Reflux/physiopathology*
;
Male
;
Female
;
Cough/physiopathology*
;
Middle Aged
;
Aged
;
Acupuncture Therapy
;
Adult
;
Treatment Outcome
;
Lung/physiopathology*
;
Meridians
5.Safety of teriflunomide in Chinese adult patients with relapsing multiple sclerosis: A phase IV, 24-week multicenter study.
Chao QUAN ; Hongyu ZHOU ; Huan YANG ; Zheng JIAO ; Meini ZHANG ; Baorong ZHANG ; Guojun TAN ; Bitao BU ; Tao JIN ; Chunyang LI ; Qun XUE ; Huiqing DONG ; Fudong SHI ; Xinyue QIN ; Xinghu ZHANG ; Feng GAO ; Hua ZHANG ; Jiawei WANG ; Xueqiang HU ; Yueting CHEN ; Jue LIU ; Wei QIU
Chinese Medical Journal 2025;138(4):452-458
BACKGROUND:
Disease-modifying therapies have been approved for the treatment of relapsing multiple sclerosis (RMS). The present study aims to examine the safety of teriflunomide in Chinese patients with RMS.
METHODS:
This non-randomized, multi-center, 24-week, prospective study enrolled RMS patients with variant (c.421C>A) or wild type ABCG2 who received once-daily oral teriflunomide 14 mg. The primary endpoint was the relationship between ABCG2 polymorphisms and teriflunomide exposure over 24 weeks. Safety was assessed over the 24-week treatment with teriflunomide.
RESULTS:
Eighty-two patients were assigned to variant ( n = 42) and wild type groups ( n = 40), respectively. Geometric mean and geometric standard deviation (SD) of pre-dose concentration (variant, 54.9 [38.0] μg/mL; wild type, 49.1 [32.0] μg/mL) and area under plasma concentration-time curve over a dosing interval (AUC tau ) (variant, 1731.3 [769.0] μg∙h/mL; wild type, 1564.5 [1053.0] μg∙h/mL) values at steady state were approximately similar between the two groups. Safety profile was similar and well tolerated across variant and wild type groups in terms of rates of treatment emergent adverse events (TEAE), treatment-related TEAE, grade ≥3 TEAE, and serious adverse events (AEs). No new specific safety concerns or deaths were reported in the study.
CONCLUSION:
ABCG2 polymorphisms did not affect the steady-state exposure of teriflunomide, suggesting a similar efficacy and safety profile between variant and wild type RMS patients.
REGISTRATION
NCT04410965, https://clinicaltrials.gov .
Humans
;
Crotonates/adverse effects*
;
Toluidines/adverse effects*
;
Nitriles
;
Hydroxybutyrates
;
Female
;
Male
;
Adult
;
ATP Binding Cassette Transporter, Subfamily G, Member 2/genetics*
;
Middle Aged
;
Multiple Sclerosis, Relapsing-Remitting/genetics*
;
Prospective Studies
;
Young Adult
;
Neoplasm Proteins/genetics*
;
East Asian People
6.Research progress on resistance mechanism and evolution of carbapenem-resistant hypervirulent Klebsiella pneumoniae
Jiawei DING ; Mengying ZHANG ; Zidan HU ; Qingrong LI ; Ying ZHOU ; Jia WANG ; Lei FENG
Chinese Journal of Nosocomiology 2025;35(16):2535-2540
Klebsiella pneumoniae,as a clinically prevalent opportunistic pathogen,ranks as the second most com-monly detected pathogen in clinical isolates in China.The extensive clinical use of carbapenem antibiotics has led to a high global detection rate of carbapenem-resistant K.pneumoniae(CRKP).Characterized by complex resist-ance mechanisms and diverse evolutionary pathways,CRKP infections pose significant challenges in prevention and treatment,with high associated mortality rates,creating substantial obstacles for clinical anti-infective therapy.In recent years,the emergence and global spread of carbapenem-resistant hypervirulent K.pneumoniae(CR-hvKP)have escalated into a major public health threat.Notably,hypervirulent K.pneumoniae isolates carry-ing carbapenem resistance genes are rapidly disseminating worldwide,causing fatal infections even in immunocom-petent individuals.This article systematically reviews the latest research advances on the resistance mechanisms,evolutionary pathways,adaptive changes,and clinical management strategies of CR-hvKP,aiming to deepen un-derstanding of this"superbug"and provide a theoretical foundation for clinical prevention and control.
7.Methodological correlation and efficacy analysis of the detection of hepatitis B virus surface antigen in clinical laboratory
Haixia WANG ; Shulin ZHANG ; Yingying ZHAO ; Yangfan FENG ; Weipeng DU ; Jingyi LIANG ; Jiawei LI
Chinese Journal of Immunology 2025;41(7):1772-1776,1781
Objective:To explore the evaluation and relationship of hepatitis B virus(HBV)surface antigen(HBsAg)in clinical laboratory in different detection systems,further scientifically and reasonably to explain the test results for serving clinical practices.Methods:During the period from June 2021 to July 2022,100 425 specimens of patients with screened,suspected and confirmed HBV infections were collected from the clinical departments(mainly infectious hepatology)of Nanyang Central Hospital.Detection methodology included quantitative(electrochemiluminescence and chemiluminescence),qualitative(gold standard),semi-quantita-tive(ELISA),and highly sensitive HBV-DNA(RT-PCR)methods,and then analyzed the strengths and weaknesses and closeness be-tween each methodology.The relationship between the two Roche HBsAg detection systems was analyzed by correlation analysis.The HBsAg efficacy analysis was validated using Cut/Off value setting and detection limit,which in turn analyzed the distribution of false-positive and false-negative reporting models.Results:Detection results for low-and medium-concentration HBsAg showed a correla-tion between the electrochemical luminescence semi-quantitative method and ELISA method.ELISA method still had advantages in terms of sensitivity and specificity when detecting HBsAg,and there were no significant differences compared to domestic and interna-tional HBsAg quantitative detection systems.Performance validation conducted in accordance with the CNAS-GL038 document showed that the minimum detection limit for HBsAg calculated using the ELISA method in this laboratory was 0.1 U/ml.When the ROC curve Cut/Off value was set to 0.105,the area under the curve was the largest(AUC=0.986).Based on Roche's semi-quantitative electroche-miluminescence detection and patient medical history,in the common reporting model for hepatitis B five-item detection using ELISA method,HBsAg false positives occurred most frequently when HBsAg was positive alone,and HBsAg occurred most frequently in the false positive range when the OD value was less than 0.5.In ELISA method for detecting HBsAg,as the OD value increased from 0.01 to 0.10,the number of false-negative results also increased.Roche Elecsys HBsAg Ⅱ Quant Ⅱ and Elecsys HBsAg Ⅱ testing systems exhibited good linearity under certain conditions,with a ratio of approximately 1/0.18.In Elecsys HBsAg Ⅱ Quant Ⅱ detection sys-tem,the test results of HBsAg samples diluted 400 times were highly consistent with the original test results with a coefficient of deter-mination R2=0.993 8.Conclusion:There was a certain relationship between various detection systems of HBsAg at a suitable concen-tration.The detection of HBsAg by ELISA can meet the needs of clinical detection.
8.Expanding molecular diversity of ribosomally synthesized and post-translationally modified peptide (RiPP) natural products by radical S-adenosylmethionine (SAM) enzymes: recent advances and mechanistic insights.
Jiawei FENG ; Jiarong MO ; Xinya HEMU
Chinese Journal of Natural Medicines (English Ed.) 2025;23(3):257-268
Ribosomally synthesized and post-translationally modified peptides (RiPPs) constitute a vast and diverse family of bioactive peptides. These peptides, synthesized by ribosomes and subsequently modified by various tailoring enzymes, possess a wide chemical space. Among these modifications, radical S-adenosylmethionine (rSAM) enzymes employ unique radical chemistry to introduce a variety of novel peptide structures, which are crucial for their activity. This review examines the major types of modifications in RiPPs catalyzed by rSAM enzymes, incorporating recent advancements in protein structure analysis techniques and computational methods. Additionally, it elucidates the diverse catalytic mechanisms and substrate selectivity of these enzymes through an analysis of the latest crystal structures.
Protein Processing, Post-Translational
;
S-Adenosylmethionine/chemistry*
;
Ribosomes/metabolism*
;
Peptides/metabolism*
;
Biological Products/metabolism*
;
Humans
9.Methodological correlation and efficacy analysis of the detection of hepatitis B virus surface antigen in clinical laboratory
Haixia WANG ; Shulin ZHANG ; Yingying ZHAO ; Yangfan FENG ; Weipeng DU ; Jingyi LIANG ; Jiawei LI
Chinese Journal of Immunology 2025;41(7):1772-1776,1781
Objective:To explore the evaluation and relationship of hepatitis B virus(HBV)surface antigen(HBsAg)in clinical laboratory in different detection systems,further scientifically and reasonably to explain the test results for serving clinical practices.Methods:During the period from June 2021 to July 2022,100 425 specimens of patients with screened,suspected and confirmed HBV infections were collected from the clinical departments(mainly infectious hepatology)of Nanyang Central Hospital.Detection methodology included quantitative(electrochemiluminescence and chemiluminescence),qualitative(gold standard),semi-quantita-tive(ELISA),and highly sensitive HBV-DNA(RT-PCR)methods,and then analyzed the strengths and weaknesses and closeness be-tween each methodology.The relationship between the two Roche HBsAg detection systems was analyzed by correlation analysis.The HBsAg efficacy analysis was validated using Cut/Off value setting and detection limit,which in turn analyzed the distribution of false-positive and false-negative reporting models.Results:Detection results for low-and medium-concentration HBsAg showed a correla-tion between the electrochemical luminescence semi-quantitative method and ELISA method.ELISA method still had advantages in terms of sensitivity and specificity when detecting HBsAg,and there were no significant differences compared to domestic and interna-tional HBsAg quantitative detection systems.Performance validation conducted in accordance with the CNAS-GL038 document showed that the minimum detection limit for HBsAg calculated using the ELISA method in this laboratory was 0.1 U/ml.When the ROC curve Cut/Off value was set to 0.105,the area under the curve was the largest(AUC=0.986).Based on Roche's semi-quantitative electroche-miluminescence detection and patient medical history,in the common reporting model for hepatitis B five-item detection using ELISA method,HBsAg false positives occurred most frequently when HBsAg was positive alone,and HBsAg occurred most frequently in the false positive range when the OD value was less than 0.5.In ELISA method for detecting HBsAg,as the OD value increased from 0.01 to 0.10,the number of false-negative results also increased.Roche Elecsys HBsAg Ⅱ Quant Ⅱ and Elecsys HBsAg Ⅱ testing systems exhibited good linearity under certain conditions,with a ratio of approximately 1/0.18.In Elecsys HBsAg Ⅱ Quant Ⅱ detection sys-tem,the test results of HBsAg samples diluted 400 times were highly consistent with the original test results with a coefficient of deter-mination R2=0.993 8.Conclusion:There was a certain relationship between various detection systems of HBsAg at a suitable concen-tration.The detection of HBsAg by ELISA can meet the needs of clinical detection.
10.A phase Ⅲ clinical study to evaluate the efficacy and safety profile of antaitasvir phosphate combined with yiqibuvir in the treatment of adults with chronic hepatitis C
Lai WEI ; Jia SHANG ; Xuan AN ; Guoqiang ZHANG ; Yujuan GUAN ; Hongxin PIAO ; Jinglan JIN ; Lang BAI ; Xingxiang YANG ; Daokun YANG ; Xinhua LUO ; Shufang YUAN ; Yingren ZHAO ; Yingjie MA ; Guangming LI ; Feng LIN ; Xiaoping WU ; Jiawei GENG ; Guizhou ZOU ; Jiabao CHANG ; Zuojiong GONG ; Xiaorong MAO ; Jing ZHU ; Wentao GUO ; Qingwei HE ; Lin LUO ; Yulei ZHUANG ; Hongming XIE ; Yingjun ZHANG
Chinese Journal of Hepatology 2025;33(6):560-569
Objective:To assess the efficacy and safety profile of antaitasvir phosphate combined with yiqibuvir in the treatment of chronic hepatitis C (CHC) of various genotypes, without cirrhosis or with compensated cirrhosis.Methods:394 cases with CHC from 22 centers were collected from October 2021 to April 2023. They were randomly assigned to receive either the experimental drugs (antaitasvir phosphate 100 mg+yiqibuvir 600 mg) or placebo treatment in a 3∶1 ratio. The patients were administered drugs once a day for 12 consecutive weeks, and then followed up for 24 weeks after treatment cessation. All subjects were unblinded at the four-week follow-up following drug discontinuation, with the experimental drug group continuing to complete subsequent post-discontinuation follow-up. The placebo group was switched to receive the experimental drugs for a repeated 12-week treatment period and followed up for another 24 weeks after discontinuation of the drug (placebo delayed treatment phase).The sustained virologic response rate (SVR12) was observed for subjects in the double-blind phase and the placebo delayed-treatment phase at 12 weeks after treatment cessation.Virological resistance analysis was performed on subjects who failed treatment. The primary efficacy endpoint was SVR12. The number and percentage of subjects who achieved "HCV RNA

Result Analysis
Print
Save
E-mail