1.Impact of digital fitting of orthokeratology on decentration and corneal aberration
Jun CAI ; Wenjia CAO ; Haoxi CHEN ; Jiaqian ZHANG ; Juanjuan WU ; Di SHEN ; Wei WEI
International Eye Science 2025;25(11):1893-1898
AIM: To investigate the decentration of the treatment zone(TZ)and the early impact on corneal higher-order aberrations(HOAs)induced by orthokeratology(OK)lenses fitted with digital corneal topography.METHODS: A retrospective longitudinal clinical study was conducted on 28 patients(28 right eyes)who were digitally fitted with OK lenses at the Laser Vision Center of Xi'an No.1 Hospital since 2023. Longitudinal measurements were taken at baseline, 1 wk, 1 and 3 mo post-treatment to assess changes in TZ diameter, decentration magnitude and direction. Furthermore, changes in corneal HOAs were observed, and correlations of decentration with each HOAs were also analyzed.RESULTS: The mean age of patients was 10.29±2.00 years, with 15 males and 13 females, and the average baseline spherical equivalent was -2.92±0.94 D. The average TZ diameters at 1 wk, 1, and 3 mo were 3.64±0.58, 3.83±0.57, and 3.69±0.55 mm, respectively, with no statistically significant differences between 1 wk and 3 mo. Horizontal decentration values were -0.43±0.28, -0.38±0.33, and -0.31±0.37 mm after wearing lenses for 1 wk, 1 and 3 mo, respectively, while vertical decentration values were -0.33±0.20, -0.33±0.23, and -0.36±0.23 mm across the same time points. The TZ consistently decentered inferotemporally, and changes in both horizontal and vertical decentration over time were not statistically significant(Fhorizontal=1.416, Phorizontal=0.252; Fvertical=0.126, Pvertical=0.882). Significant increases in total corneal HOAs, coma, and spherical aberration were observed at 5 mm optical zone post-wear(F=45.695, 33.401, and 45.091, all P<0.001). Vertical decentration at 1 wk and 1 mo was negatively correlated with total HOAs and coma(all P<0.05), while horizontal decentration at 3 mo showed a weak negative correlation with spherical aberration(P=0.037).CONCLUSION: Digitally-fitted OK lenses achieved stable TZ diameter by 1 wk post-wear, with minor inferotemporal decentration. Early post-wear corneal total HOAs, coma and sphercal aberration increased significantly, and vertical downward decentration was associated with elevated total HOAs and coma. However, correlations between decentration and HOAs weakened by 3 mo.
2.Heart rate changes in patients during small incision lenticule extraction surgery
Yan ZHAO ; Kun ZHOU ; Jun CAI ; Caiyuan XIE ; Di SHEN ; Jiaqian ZHANG ; Wei WEI
International Eye Science 2025;25(4):685-688
AIM: To explore the factors influencing heart rate(HR)changes during small incision lenticule extraction(SMILE)surgery by monitoring HR trends at different time points of the procedure.METHODS: Prospective cohort study. A total of 69 patients who underwent SMILE surgery at the Laser Vision Correction Center of Xi'an No.1 Hospital from April to May 2024 were enrolled. Before the surgery, patients completed the State Anxiety Inventory(S-AI, questions 1-20)to assess their preoperative anxiety scores related to the next day's surgery. Baseline HR was recorded using medical pulse oximeter, and real-time HR was recorded during patient positioning, lenticule scanning, lenticule separation and extraction, and the application of postoperative eye drops.RESULTS: The HR during patient positioning was 83.61±13.87 bpm, which was significantly different from the baseline HR(77.52±10.88 bpm), HR during lenticule separation and extraction(75.54±12.52 bpm), and HR during postoperative eye drop application(76.65±10.54 bpm; all P<0.001). When stratified by median age, older patients(>26 years)had the HR during lenticule separation and extraction 76.27±9.93 bpm, which differed from the HR at positioning(84.82±14.10 bpm)and at lens scanning(82.76±13.72 bpm; all P<0.005). Stratified by gender, the HR of male patients at positioning was the highest(85.31±16.61 bpm), which differed significantly from the baseline HR(78.26±12.63 bpm), HR during lenticule separation and extraction(77.14±14.59 bpm), and HR during postoperative eye drop application(77.11±12.49 bpm; all P<0.005). There was no correlation between HR during positioning and preoperative anxiety scores(r=0.124, P=0.418).CONCLUSION: HR changes during SMILE surgery vary with different procedural stages, peaking during patient positioning and reaching the lowest point during lenticule separation and extraction. Older patients showed higher HR during positioning, and male patients exhibited higher HR during positioning.
3.Clinical and genetic investigation of 4 children with microdeletion KBG syndrome
Miaomiao LI ; Zixia ZHANG ; Shiqi WANG ; Xi WANG ; Jiaqian HU ; Mengqin WANG ; Haiyan WEI ; Yongxing CHEN
Chinese Journal of Pediatrics 2025;63(7):794-797
Objective:To analyze the genetic characteristics of clinical manifestations in children with KBG syndrome due to microdeletions.Methods:A retrospective case summary was conducted. Four children diagnosed with KBG syndrome due to 16q24.3 microdeletion at Children′s Hospital of Zhengzhou University from July 2021 to April 2024 were enrolled.Their clinical manifestations, biochemical parameters, imaging data, whole-exome sequencing results, treatments and follow-up outcomes were reviewed.Results:The cohort included two males and two females (diagnosed at 81, 18, 26, and 56 months of age, respectively), from four unrelated families. All patients exhibited peculiar facial features (Cupid′s bowed-shaped lips, prominent ears, thick eyebrows), skeletal abnormalities (brachydactyly, abnormal ribs, short stature, etc.), ocular anomalies (astigmatism, strabismus, amblyopia, etc.), intrauterine growth restriction, and developmental retardation. Case 2, 3, 4 had cranial imaging abnormalities, including thin anterior pituitary lobes with pineal cyst, left ventricular cyst, and abnormal pituitary stalk or lateral ventricles with sinusitis, respectively. Two children had intellectual disability, two had congenital heart disease, and one had delayed bone age and hair abnormalities. Whole exome genomic sequencing confirmed 16q24.3 microdeletions encompassing ANKRD11 gene in all four cases. Two children treated with recombinant human growth hormone achieved height increments of 1.5 s and 0.4 s, respectively. Conclusions:Typical features of 16q24.3 microdeletion-induced KBG syndrome include peculiar facial features, macrodontia, skeletal anomalies, neurological abnormalities, and ocular defects. Genetic testing is essential for definitive diagnosis. The treatment of KBG syndrome requires early diagnosis and multidisciplinary collaboration to implement individualized treatment for multisystem symptoms.
4.Imaging findings of contrast-enhanced ultrasound in diagnosis of solid pseudopapillary tumor of pancreas compared with contrast-enhanced computed tomography
Zebang YANG ; Wenxin WU ; Xiaoer ZHANG ; Tongyi HUANG ; Lin JIANG ; Jiaqian YAO ; Xiaoyan XIE ; Ming XU
Chinese Journal of Ultrasonography 2025;34(3):216-224
Objective:To investigate the diagnostic value of contrast-enhanced ultrasound(CEUS)in solid pseudopapillary tumor of pancreas(SPTP),summarize the CEUS characteristics of SPTP,and to compare its CEUS enhancement with contrast-enhanced computed tomography(CECT).Methods:In this retrospective study,baseline characteristics,basic ultrasound and CEUS images,CECT images of 70 patients diagnosed as SPTP from January 2009 to August 2023 were collected. Images were analyzed for extraction of key features and diagnostic accuracies of both CEUS and CECT were calculated. The relationships between ultrasound features and lesion size of SPTP were analyzed by Point-Biserial correlation analysis and Student t test. The diagnostic accuracy was compared by Mann-Whitney U test. Results:Iso-enhancement(55.7%,39/70)was commonly appeared in the early phase of CEUS for SPTP,while hypo-enhancement(74.3%,52/70)was the most common in the late phase. And the most common enhancement pattern was iso-hypo enhancement(41.4%,29/70). Lesion membrane enhancement(47.1%,33/70),intralesional compartmentalization(28.6%,20/70),and intralesional vessels(25.7%,18/70)were the 3 typical signs found in CEUS for SPTP,which were correlated with lesion size( P<0.001). Differences were found between the enhancement pattern of SPTP in CEUS and CECT,in which the most common enhancement patterns were hypo-hypo enhancement(41.4%,24/58)and iso-iso enhancement(29.3%,17/58)along with progressive enhancement. The diagnostic accuracies of CEUS and CECT were 71.4% and 74.1% respectively without statistically significant difference( P=0.733). Conclusions:CEUS shows high application value in the diagnosis of SPTP,and the accuracy of CEUS is comparable to that of CECT.
5.Study on the influence of field angle on the results of EPID dose verification in vivo
Jia FANG ; Wanli ZHU ; Chunyan DAI ; Yi ZHANG ; Yingjie MEI ; Jiaqian DAI ; Hongzhi ZHANG ; Fei ZHAO ; Shubo DING
Chongqing Medicine 2025;54(4):898-902
Objective To investigate the effect of field angle on the results of in vivo dose validation of electronic portal imaging device(EPID)in patients.Methods Design the mold test and analyze the influence of different mold thicknesses and different frame angles on the 2D γ pass rate.Twenty-three patients who un-derwent radiotherapy in the Department of Radiotherapy of Jinhua Municipal Central Hospital from January to June 2023 were selected as the research object.In vivo dose verification was carried out during treatment to obtain 2D γ pass rate using same-day sector beam CT(FBCT)of planned CT and executive image guided(IG-RT)as reference images,and the influence of field angle on pass rate was analyzed.Results When the frame angle was unchanged,the area of the shooting field was larger than 17 cm×17 cm,and the 2D γ passing rate decreased with the increase of the thickness.The frame angle had no effect on the 2D γ pass rate when the mold thickness was constant.In clinical treatment data,the passage rate of 2D γ near 0°/180° was higher than that near 90°/270°(P<0.05),and the passage rate near 90°/270° in the FBCT group was higher than that in the IGRT group(P<0.05).The median passing rate of 3 mm 2D γ was 97.97%in 3%of the 23 patients.The non-IGRT group was 96.81%,the IGRT group was 97.89%,the FBCT group was 98.94%.There was a statistically significant difference in 2D γ passing rate between the non-IGRT group and the IGRT group(Z=-5.083,P<0.05),and there was a statistically significant difference in 2D γ passing rate between the IGRT group and the FBCT group(Z=-10.657,P<0.05).Conclusion Clinically,the difference of pass rate in vi-vo dose verification at different rack angles is mainly due to the difference of images within and between ses-sions.Using same-day FBCT as the reference image for in-vivo dose verification can improve the accuracy of pass rate and eliminate the influence of image difference between sessions.
6.Studies on the Chemical Epigenetic Modification of Fungus Samsoniella Hepiali CDB9-31
Jinli ZHAO ; Hongyan YANG ; Jiaqian YANG ; Xinyi CHEN ; Qing ZHAO ; Xiaomei ZHANG
Journal of Kunming Medical University 2025;46(8):10-19
Objective To analyze the effects of the histone deacetylase inhibitor suberoylanilide hydroxamic acid(SAHA)on the secondary metabolites of the entomopathogenic fungus Samsoniella hepiali CDB9-31 using thin-layer chromatography(TLC)and high-performance liquid chromatography(HPLC).Methods The fermentation products of Samsoniella hepiali CDB9-31 treated with epigenetic modifiers were separated and purified using methods such as silica gel column chromatography,Sephadex column chromatography and reversed-phase column chromatography.The structures of the compounds were elucidated using modern spectroscopic analysis methods.The antimicrobial activity of the obtained monomeric compounds was determined using the filter paper disc diffusion method.Results The TLC and HPLC analyses of its fermentation extracts revealed that SAHA could induce the strain to produce more diverse array of secondary metabolites,and 11 monomeric compounds were isolated and identified as follows:N'-phenyloctanediamide(1),5-Phenylcarbamoyl-pentanoic(2),ergosterol(3),5,8-Epidioxy-5α,8α-ergosta-6,22E-diene-3β-ol(4),1-monolinolein(5),(4E,8E)-2-N-(2-Hydro-xypalmitoyl)-1-O-(β-D-glucopyranosyl)-9-methyl-4,8-sphingadienine(6),Ergosterol peroxide 3-O-β-D-glucopyranoside(7),(22E,24R)-7,22-diene-3β,5α,6β-ergostatriol(8),(2S,2'R,3R,4E,8E)-N-2'-Hydroxyhexadecanoyl-2-amion-9-methyl-4,8-octadecadiene-1,3-diol(9),Adenosine(10),D-Glulopyranose(11).Compounds 1 and 2 were derivatives of SAHA,and it was speculated that the special metabolic environment of CDB9-31 caused the biotransformation of SAHA.Except for compound 3,all other compounds were isolated from this genus for the first time.The antibacterial activity results showed that six of these compounds exhibited varying degrees of inhibitory effects against at least one pathogenic bacterium.Conclusion This study has enriched the chemical diversity of secondary metabolites from the entomopathogenic fungus Samsoniella hepiali.
7.A scoping review of functional prognosis prediction models for stroke patients
Jiaqian KUANG ; Chun CHEN ; Qian ZHANG
Chinese Journal of Nursing 2025;60(3):364-372
Objective To conduct a comprehensive review of functional prognosis prediction models for stroke patients,offering insights for clinical nursing practice and research.Methods A search was conducted across various databases including PubMed,Web of Science,Embase,CINAHL,Cochrane Library,China National Knowledge Infrastructure,Wanfang Database,VIP Database,and China Biomedical Literature Database from their inception to April 1,2024.There were 2 researchers who independently screened the literature,extracted data,and assessed the quality of the studies.Results The review included 19 studies on the development of functional prognosis prediction models for stroke patients,resulting in a total of 57 models.The area under the receiver operating characteristic curve ranged from 0.730 to 0.974.External validation was performed for 3 of the models.Age,gender,NIHSS,and history of stroke emerged as the principal predictors in the functional prognosis prediction models for stroke patients.Conclusion Research on functional prognosis prediction models for stroke patients is still in its early stages,with models demonstrating reasonable predictive power but carrying a high risk of bias.Future studies should standardize model development and validation.The aim should be to create user-friendly models with strong predictive capabilities,thereby providing healthcare professionals with solid foundations for clinical decision-making.
8.A scoping review of functional prognosis prediction models for stroke patients
Jiaqian KUANG ; Chun CHEN ; Qian ZHANG
Chinese Journal of Nursing 2025;60(3):364-372
Objective To conduct a comprehensive review of functional prognosis prediction models for stroke patients,offering insights for clinical nursing practice and research.Methods A search was conducted across various databases including PubMed,Web of Science,Embase,CINAHL,Cochrane Library,China National Knowledge Infrastructure,Wanfang Database,VIP Database,and China Biomedical Literature Database from their inception to April 1,2024.There were 2 researchers who independently screened the literature,extracted data,and assessed the quality of the studies.Results The review included 19 studies on the development of functional prognosis prediction models for stroke patients,resulting in a total of 57 models.The area under the receiver operating characteristic curve ranged from 0.730 to 0.974.External validation was performed for 3 of the models.Age,gender,NIHSS,and history of stroke emerged as the principal predictors in the functional prognosis prediction models for stroke patients.Conclusion Research on functional prognosis prediction models for stroke patients is still in its early stages,with models demonstrating reasonable predictive power but carrying a high risk of bias.Future studies should standardize model development and validation.The aim should be to create user-friendly models with strong predictive capabilities,thereby providing healthcare professionals with solid foundations for clinical decision-making.
9.Clinical and genetic investigation of 4 children with microdeletion KBG syndrome
Miaomiao LI ; Zixia ZHANG ; Shiqi WANG ; Xi WANG ; Jiaqian HU ; Mengqin WANG ; Haiyan WEI ; Yongxing CHEN
Chinese Journal of Pediatrics 2025;63(7):794-797
Objective:To analyze the genetic characteristics of clinical manifestations in children with KBG syndrome due to microdeletions.Methods:A retrospective case summary was conducted. Four children diagnosed with KBG syndrome due to 16q24.3 microdeletion at Children′s Hospital of Zhengzhou University from July 2021 to April 2024 were enrolled.Their clinical manifestations, biochemical parameters, imaging data, whole-exome sequencing results, treatments and follow-up outcomes were reviewed.Results:The cohort included two males and two females (diagnosed at 81, 18, 26, and 56 months of age, respectively), from four unrelated families. All patients exhibited peculiar facial features (Cupid′s bowed-shaped lips, prominent ears, thick eyebrows), skeletal abnormalities (brachydactyly, abnormal ribs, short stature, etc.), ocular anomalies (astigmatism, strabismus, amblyopia, etc.), intrauterine growth restriction, and developmental retardation. Case 2, 3, 4 had cranial imaging abnormalities, including thin anterior pituitary lobes with pineal cyst, left ventricular cyst, and abnormal pituitary stalk or lateral ventricles with sinusitis, respectively. Two children had intellectual disability, two had congenital heart disease, and one had delayed bone age and hair abnormalities. Whole exome genomic sequencing confirmed 16q24.3 microdeletions encompassing ANKRD11 gene in all four cases. Two children treated with recombinant human growth hormone achieved height increments of 1.5 s and 0.4 s, respectively. Conclusions:Typical features of 16q24.3 microdeletion-induced KBG syndrome include peculiar facial features, macrodontia, skeletal anomalies, neurological abnormalities, and ocular defects. Genetic testing is essential for definitive diagnosis. The treatment of KBG syndrome requires early diagnosis and multidisciplinary collaboration to implement individualized treatment for multisystem symptoms.
10.Imaging findings of contrast-enhanced ultrasound in diagnosis of solid pseudopapillary tumor of pancreas compared with contrast-enhanced computed tomography
Zebang YANG ; Wenxin WU ; Xiaoer ZHANG ; Tongyi HUANG ; Lin JIANG ; Jiaqian YAO ; Xiaoyan XIE ; Ming XU
Chinese Journal of Ultrasonography 2025;34(3):216-224
Objective:To investigate the diagnostic value of contrast-enhanced ultrasound(CEUS)in solid pseudopapillary tumor of pancreas(SPTP),summarize the CEUS characteristics of SPTP,and to compare its CEUS enhancement with contrast-enhanced computed tomography(CECT).Methods:In this retrospective study,baseline characteristics,basic ultrasound and CEUS images,CECT images of 70 patients diagnosed as SPTP from January 2009 to August 2023 were collected. Images were analyzed for extraction of key features and diagnostic accuracies of both CEUS and CECT were calculated. The relationships between ultrasound features and lesion size of SPTP were analyzed by Point-Biserial correlation analysis and Student t test. The diagnostic accuracy was compared by Mann-Whitney U test. Results:Iso-enhancement(55.7%,39/70)was commonly appeared in the early phase of CEUS for SPTP,while hypo-enhancement(74.3%,52/70)was the most common in the late phase. And the most common enhancement pattern was iso-hypo enhancement(41.4%,29/70). Lesion membrane enhancement(47.1%,33/70),intralesional compartmentalization(28.6%,20/70),and intralesional vessels(25.7%,18/70)were the 3 typical signs found in CEUS for SPTP,which were correlated with lesion size( P<0.001). Differences were found between the enhancement pattern of SPTP in CEUS and CECT,in which the most common enhancement patterns were hypo-hypo enhancement(41.4%,24/58)and iso-iso enhancement(29.3%,17/58)along with progressive enhancement. The diagnostic accuracies of CEUS and CECT were 71.4% and 74.1% respectively without statistically significant difference( P=0.733). Conclusions:CEUS shows high application value in the diagnosis of SPTP,and the accuracy of CEUS is comparable to that of CECT.

Result Analysis
Print
Save
E-mail