1.Value of biopsy by contrast-enhanced ultrasound in diagnosis of nature of type 4 thyroid nodules by thyroid imaging reporting and data system
Hao XU ; Jiaoran LIU ; Bojian GAO ; Rongxin ZHANG ; Tianya WANG
Journal of Clinical Medicine in Practice 2025;29(7):8-12
Objective To investigate the value of contrast-enhanced ultrasound(CEUS)guided fine needle aspiration(FNA)in diagnosing the nature of type 4 thyroid nodules by thyroid imaging re-porting and data system(TI-RADS).Methods A total of 120 patients with TI-RADS type 4 thyroid nodules were selected as subjects.Sixty patients underwent CEUS-guided FNA(CEUS group),while the other 60 patients underwent conventional ultrasound-guided FNA(conventional ultrasound group).Using pathological results as the gold standard,Kappa consistency tests were used to analyze the diagnostic consistency of conventional ultrasound-guided FNA and CEUS-guided FNA for TI-RADS type 4 thyroid nodules.Results Among 120 patients with TI-RADS type 4 thyroid nodules(138 nodules),85 malignant nodules and 53 benign nodules were confirmed by pathology.In the CEUS group,there were 28 benign nodules and 42 malignant nodules(40 papillary thyroid carcino-mas and 2 medullary carcinomas).In the conventional ultrasound group,there were 25 benign nod-ules and 43 malignant nodules(39 papillary thyroid carcinomas and 4 medullary carcinomas).The false positive rate and false negative rate of conventional ultrasound-guided FNA for diagnosing malignant TI-RADS type 4 thyroid nodules were 3.62%and 5.07%,respectively.For CEUS-guided FNA,the rates were 2.17%and 2.90%,respectively.The sensitivity,specificity and accuracy of con-ventional ultrasound-guided FNA for diagnosing the nature of TI-RADS type 4 thyroid nodules were 83.72%,80.00%and 82.35%,respectively,with Kappa value of 0.627.For CEUS-guided FNA,these values were 90.48%,89.29%and 90.00%,respectively,with Kappa value of 0.793.Based on pathological examination,the diagnostic agreement rates for malignant TI-RADS type 4 thyroid nodules were 79.07%for conventional ultrasound-guided FNA and 83.33%for CEUS-guided FNA,with Kappa values of 0.719 and 0.786,respectively.Conclusion CEUS-guided FNA can provide high-resolution,real-time dynamic imaging information,thereby improving the sensitivity and specificity of diagnosing the nature of TI-RADS type 4 thyroid nodules.
2.Multiple Logistic Regression Analysis of Risk Factors for Brain Edema Detected by Ultrasound Examination in Term Infants
Fang LIU ; Jiaoran LIU ; Zhifang DU ; Zhimei GUO ; Zhaoxia LV ; Chunfeng ZHOU
Journal of Medical Research 2009;38(8):68-70
Objective To study the clinic value of brain edema detected by ultrasound examination in high risk term infants. Meth-ods The study group included 140 term infants who were found having brain edema in cranial ultrasound examinations. 152 term infants with normal ultrasound scan were selected as a control group. The risk factors of brain edema were collected, and univariate analysis and multivariate logistic regression analysis were performed. Results (1) There was no difference of incidence of brain edema between the infants with or without maternal ill historys, fetal distress or hypoalbuminemia, with P > 0.05. (2) In the univariate regression model, as-phyxia,hypoxic -ischemic encephalopathy (HIE) ,ventilation and metabolic acidosis were associated with an increased risk of brain ede-ma. In the multivariate logistic regression model, HIE was associated with a greater risk of brain edema and ventilation was possibly asso-ciated with brain edema. Conclusion Brain edema detected by ultrasound examination in high risk term infants has close relationship with HIE. It suggest that there is a consistency between ultrasound results and clinic situation. The detection of brain edema by ultrasound can assist doctor in clinic practice.

Result Analysis
Print
Save
E-mail