1.Introduction and enlightenment of the Recommendations and Expert Consensus for Plasm a and Platelet Transfusion Practice in Critically ill Children: from the Transfusion and Anemia Expertise Initiative-Control/Avoidance of Bleeding (TAXI-CAB)
Lu LU ; Jiaohui ZENG ; Hao TANG ; Lan GU ; Junhua ZHANG ; Zhi LIN ; Dan WANG ; Mingyi ZHAO ; Minghua YANG ; Rong HUANG ; Rong GUI
Chinese Journal of Blood Transfusion 2025;38(4):585-594
To guide transfusion practice in critically ill children who often need plasma and platelet transfusions, the Transfusion and Anemia Expertise Initiative-Control/Avoidance of Bleeding (TAXI-CAB) developed Recommendations and Expert Consensus for Plasma and Platelet Transfusion Practice in Critically Ill Children. This guideline addresses 53 recommendations related to plasma and platelet transfusion in critically ill children with 8 kinds of diseases, laboratory testing, selection/treatment of plasma and platelet components, and research priorities. This paper introduces the specific methods and results of the recommendation formation of the guideline.
2.Research and Discussion on the Whole Lifecycle Supervision of Typical Class Ⅱ Wound Dressing Products.
Lan ZHANG ; Ye ZENG ; Xin XIE ; Jiaohui BAO ; Xiaohe YANG ; Weiming QI
Chinese Journal of Medical Instrumentation 2025;49(3):344-349
In this study, the pre-market regulatory requirements for typical Class Ⅱ wound dressings, as well as the status of testing and post-market adverse events monitoring, were reviewed from the perspective of the whole lifecycle of medical devices. Additionally, the regulatory requirements for wound dressings in China, the United States, and the European Union were compared. Supplementary research was also conducted on Class Ⅰ and Ⅱ liquid and paste dressing products. Furthermore, this study analyzed the issues in the registration and application of typical Class Ⅱ wound dressings and provided regulatory recommendations, aiming to offer technical references for the review and approval, inspection and testing, and post-market supervision of wound dressing products.
Bandages/standards*
;
United States
;
China
;
Humans
;
European Union
3.Introduction and enlightenment of the Recommendations and Expert Consensus for What Laboratory Tests and Physiologic Triggers Should Guide the Decision to Administer a Platelet or Plasma Transfusion in Critically ill Children and What Product Attributes Are Optimal to Guide Specific Product Selection? From the Transfusion and Anemia Expertise Initiative-Control/Avoidance of Bleeding
Xionghui ZHOU ; Jiaohui ZENG ; Hao TANG ; Lan GU ; Zhi LIN ; Dan WANG ; Mingyi ZHAO ; Minghua YANG ; Rong GUI ; Rong HUANG ; Junhua ZHANG
Chinese Journal of Blood Transfusion 2025;38(11):1641-1649
Based on systematic review and consensus meetings of international multidisciplinary experts, the Transfusion and Anemia Expert Initiative—Control/Avoidance of Bleeding (TAXI-CAB) project team developed management strategies for platelet and plasma transfusion in critically ill children. This consensus presents five expert consensus statements and two recommendations addressing two key questions: 1) What Laboratory Tests and Physiologic Triggers Should Guide the Decision to Administer a Platelet or Plasma Transfusion in Critically ill Children? 2) What Product Attributes Are Optimal to Guide Specific Product Selection? This consensus provides guidance for decision-making regarding plasma and platelet transfusion in critically ill children in two aspects: relevant laboratory testing indicators and additional special properties of blood components. This article explains the rationale behind the recommendations in this part of the guideline, aiming to emphasize the need for clinicians to develop transfusion strategies based on multidimensional assessment, while calling for enhanced interdisciplinary collaboration and evidence-based research to optimize blood management in critically ill children, reducing the risk of over-transfusion and improving treatment outcomes. Furthermore, there remains an urgent need for further research to explore laboratory indicators associated with bleeding risk to guide transfusion therapy.
4.Comparative analysis between HP-083/4 and rational used instrument on results of six items
Rong HUANG ; Meng GAO ; Yunfeng FU ; Jiaohui ZENG ; Guosheng ZHAO ; Mengqing YI ; Jing LIU ; Xinrui CHEN
International Journal of Laboratory Medicine 2015;(19):2789-2791,2793
Objective To compare the performance of HP-083/4 and rational used instrument on detecting six items.Methods The rational instruments were used as contrast instrument,HP-083/4 was the verified instrument.A total of 100 blood specimens and 100 urine specimens were collected,and the levels of antistreptolysin O(ASO),hypersensitive C reactive protein (hsCRP),D-di-mer(D-D),glycosylated hemoglobin(HbA1c),rheumatoid factor(RF)and urine microalbumin(mAlb)were detected.The regression equation and correlation coefficient(r)of the two methods were calculated,and the Kappa values(κ)were analyzed to evaluate the performance of HP-083/4.Results There was a good linear correlation (r >0.950)for the two methods in detecting the serum ASO,hsCRP,D-D,HbA1c,RF and mAlb,r were 0.991,0.995,0.970,0.957,0.980 and 0.967 respectively.Besides,they had good concordance(κ>0.6),theκ values were 0.830,0.957,0.601,0.720,0.920 and 0.694 respectively.Conclusion HP-083/4 is effec-tive in detecting ASO,hsCRP,D-D,HbA1c,RF and mAlb,which should be suitable for clinical application.

Result Analysis
Print
Save
E-mail