1.Comparative Analysis of Clinical Efficacy of Traditional Chinese Medicine Manipulative Reduction Combined with Small Splint Fixation Versus Surgical Treatment for Type A Distal Radius Fracture
Yang SHAO ; Zihan WANG ; Jianwei WANG ; Guoda DAI ; Hengyan CUI ; Zhen HUA ; Tingchen ZHU ; Shaoshuo LI ; Jun MAO ; Fenghua CHEN ; Shuai TAO ; Mao WU
Journal of Traditional Chinese Medicine 2026;67(10):1078-1085
ObjectiveTo compare the clinical efficacy of traditional Chinese medicine (TCM) manipulative reduction combined with small splint fixation versus surgical treatment for type A distal radius fracture (DRF) and to explore the factors influencing the choice of treatment. MethodsA multi-center retrospective study was conducted, collecting data from 1237 type A DRF patients treated in 11 hospitals in Jiangsu province from September, 2023 to April, 2025. Among them, 851 patients in the TCM group received manipulative reduction combined with small splint fixation, and 386 patients in the surgical group underwent open reduction and internal fixation. Visual analog scale (VAS) scores for pain and radiographic indicators including palmar tilt, ulnar deviation, and radial height were compared before treatment, 5-7 days after treatment, and 4-6 weeks after treatment. The wrist joint function scores including Dienst and Gartland-Werley scores at 12 weeks after treatment were recorded. Subgroup analysis was conducted for the excellent rate of Dienst and Gartland-Werley scores, stratified by age (<50, 50-59, 60-69, ≥70 years old) and AO subtypes (A1, A2, A3). A multivariate logistic regression model was used to identify independent factors influencing treatment choice. ResultsOn 5-7 days after treatment, the surgical group had lower VAS scores than the TCM group, while 4-6 weeks after treatment, the TCM group showed lower VAS scores than the surgical group (P<0.01). In terms of radiographic indicators, except for the palmar tilt before treatment being higher in the surgical group than in the TCM group (P<0.01), there were no significant differences in palmar tilt, ulnar deviation, and radial height at other timepoints (P>0.05). Twelve weeks after treatment, the surgical group had a higher average Gartland-Werley score and the excellent rate than the TCM group (P<0.01). Subgroup analysis showed that in patients with A2 type DRF aged 50-59 and 60-69 years old, the excellent rates of Dienst and Gartland-Werley scores in the TCM group were higher than those in the surgical group (P<0.05). Multivariate logistic regression analysis revealed that age, palmar tilt, ulnar deviation, and the degree of swelling on the affected side were independent factors influencing the choice of treatment (P<0.05). ConclusionBoth TCM manipulative reduction combined with small splint fixation and surgical treatment for type A DRF can achieve good therapeutic effects. TCM manipulative reduction combined with small splint fixation has certain advantages in medium- and long-term pain relief, especially in elderly patients, where wrist joint function recovery is more stable. Age, palmar tilt, ulnar deviation, and swelling degree are the main factors influencing the treatment choice.
2.Clinical Efficacy and Radiographic Outcomes of Manipulative Reduction Combined with Small Splint Fixation for Distal Radius Fractures:A Retrospective Multicenter Study with Propensity Score Matching
Mao WU ; Guoda DAI ; Yang SHAO ; Shaoshuo LI ; Zhen HUA ; Hengyan CUI ; Tingchen ZHU ; Dipeng LI ; Jintao LIU ; Ming ZHOU ; Peimin WANG ; Liyong ZHANG ; Jianwei WANG
Journal of Traditional Chinese Medicine 2026;67(10):1086-1092
ObjectiveTo observe the clinical efficacy and radiographic outcomes of manipulative reduction combined with small splint fixation in the treatment of distal radius fractures. MethodsThe clinical data of 1051 patients with distal radius fractures were retrospectively collected from five hospitals included in the Jiangsu Diagnosis and Treatment Data Platform for Traditional Chinese Medicine(TCM) Dominant Diseases. Propensity score matching at a 1∶4 ratio was applied, resulting in 580 cases selected for final analysis, which comprised 448 patients in the TCM group(manipulative reduction plus small splint fixation) and 132 in the surgical treatment group(open reduction and internal fixation). Each group was further stratified into type A, B, and C subgroups based on AO fracture classification. Radiographic indicators including palmar tilt, radial inclination, and radial height were compared between groups before treatment and 1 day, 1 week, and 4-6 weeks after treatment, and pain visual analog scale(VAS) scores before treatment and 1 week and 4-6 weeks after treatment were also compared. Wrist joint function was assessed 12 weeks after treatment, using the Dienst wrist function score and the Gartland and Werley(G-W) wrist function score. Additionally, the radiographic indicators at different timepoints and the 12-week wrist function levels were compared between groups across different fracture types. ResultsNo statistically significant difference was observed in radiographic indicators and VAS scores at all timepoints before and after treatment, as well as wrist joint function grades assessed by the Dienst score and the G-W score at 12 weeks after treatment (P>0.05). Compared to those before treatment, both groups showed increased palmar tilt, radial inclination, and radial height 1 week and 4-6 weeks after treatment, and decreased VAS scores (P<0.05). Compared to those 1 week after treatment, both groups showed a decrease in palmar tilt, an increase in radial inclination and radial height, and a reduction in VAS score 4-6 weeks after treatment(P<0.05). In type A and B subgroups, the surgical treatment group had a higher radial inclination than the TCM group 4-6 weeks after treatment, while in the type C subgroup, a higher radial height was shown in the surgical treatment group than in the TCM group 4-6 weeks after treatment(P<0.05). In type C subgroup, there was significant difference between groups in the wrist joint function by G-W scores 12 weeks after treatment(P<0.05). ConclusionManipulative reduction combined with small splint fixation can maintain fracture alignment and alleviate pain in treating distal radius fractures, which achieves therapeutic outcomes comparable to surgical treatment. It is particularly suitable for type A and B fractures and can be considered an effective treatment option for distal radius fractures.
3.Construction and Clinical Validation of a Deep Learning-Based Automatic Measurement Model for Palmar Tilt and Radial Inclination in Distal Radius Fractures
Guoda DAI ; Jianwei WANG ; Mao WU ; Bin KANG ; Yang SHAO ; Hengyan CUI ; Shaoshuo LI ; Tingchen ZHU ; Zhen HUA ; Zhongming SHEN ; Jintao LIU ; Ming ZHOU
Journal of Traditional Chinese Medicine 2026;67(10):1093-1100
ObjectiveTo construct an automatic measurement model for palmar tilt and radial inclination suitable for traditional Chinese medicine (TCM) clinical scenarios, and to validate its accuracy and efficiency in TCM manipulative reduction settings. MethodsData on anteroposterior (AP) and lateral X-rays of distal radius fractures were collected from patients admitted to 18 TCM/ integrated TCM and western medicine hospitals in Jiangsu province between September 1st, 2023, and September 1st, 2024, via the Jiangsu Diagnosis and Treatment Big Data Platform for TCM Dominant Diseases. A medical image segmentation framework based on multi-scale feature fusion and edge-awareness was employed, combined with anatomical knowledge specific to TCM orthopedics, to optimize the feature extraction strategy of an artificial intelligence (AI) model. This framework enabled automatic segmentation of fracture regions and measurement of distal radius palmar tilt and radial inclination. The accuracy of the AI model in measuring radial inclination and volar tilt was validated, and the measurement time and average time gain rate of the AI model were compared to those of manual measurement. ResultsA total of 15,444 AP and lateral X-ray images of distal radius fractures were collected, and were divided into a training set (11,144 images, 5066 AP and 6078 lateral), a validation set (3700 images, 1840 AP and 1860 lateral), and an independent test set (600 images, 300 AP and 300 lateral) after preprocessing. In the measurement of 300 AP X-rays in the independent test set for radial inclination, when the degree error between AI measurement and manual measurement was <3° and <5°, AI measurement accuracy was 83% and 93%, respectively. In 300 lateral X-rays in the test set for palmar tilt, when AI measurements had an error of <3° and <5° compared to manual measurements, corresponding accuracy rate was 78% and 90%, respectively. For 50 X-ray images, AI measurement time was (1.37±0.05) min for radial inclination while manual measurement time was (22.57±2.52) min (P<0.001); in terms of palmar tilt, the AI measurement time was (1.33±0.14) min, shorter than (23.70±2.80) min for manual measurement time (P<0.001). Average time gain rates for manual and AI measurements were 93.93% and 94.39% respectively. ConclusionAn automatic measurement model for palmar tilt and radial inclination in distal radius fractures has been established, enabling more accurate and efficient assessment as well as providing a tool to support the quantitative evaluation of the efficacy of TCM manipulative reduction and large-sample clinical research.
4.Research on the safety management for risk identification model based on DBN in precision medical research equipment of central laboratory
Qinhan ZHU ; Qin WANG ; Jianwei ZHANG ; Fang WANG
China Medical Equipment 2025;22(3):132-137
Objective:To construct a risk identification model based on the Dynamic Bayesian Network(DBN)and explore its safety management effect in the precision medical research equipment of the central laboratory.Methods:Based on the DBN model,a risk identification model was constructed after various risk factors in the management for precision medical research equipment of central laboratory were identified,and a risk index evaluation set was constructed to provide early warning and effective prevention of potential risks during the operation stage of the equipment.A total of using 51 precision medical research equipment in central laboratory of Shuguang Hospital of Shanghai University of Traditional Chinese Medicine from February 2023 to February 2024 were selected.According to different management modes,26 of them were managed by the conventional management mode,and 25 were managed by the DBN risk identification model management mode(DBN management mode).A self-made questionnaire on equipment management recognition was used to conduct a survey among 15 engineers,15 equipment operators and 10 doctors involved in equipment use.The equipment target achievement degree,clinical service quality,equipment risk incidence rate and the recognition scores of personnel related to equipment use for equipment management under the two management modes were compared.Results:The scores of equipment operation standardization,disinfection and cleaning completion and emergency management timeliness under the DBN management mode were(91.58±3.36),(90.58±3.69)and(93.69±4.25)points respectively,all of which were higher than those under the conventional management mode,and the differences were statistically significant(t=19.466,15.704,15.549,P<0.05).The average values of equipment execution rate,quality inspection qualification rate and fault handling rate were(92.69±3.69)%,(93.27±3.01)%and(94.57±3.65)%respectively,all of which were higher than those under the conventional management mode,and the differences were statistically significant(t=13.811,18.401,20.374,P<0.05).The equipment failure rate,component damage rate and unqualified rate of cleaning and disinfection were 4%(1/25),8%(2/25)and 4%(1/25)respectively,all of which were lower than those under the conventional management mode,and the differences were statistically significant(x2=10.395,12.829 and 13.542,P<0.05).The average recognition scores of engineers,operators and doctors involved in equipment use for the DBN management mode were(90.26±4.65),(91.54±4.62)and(93.25±3.65)points respectively,all of which were higher than those under the conventional management mode,and the differences were statistically significant(t=12.910,12.379,18.328,P<0.05).Conclusion:The application of the DBN-based risk identification model in the management for precision medical research equipment of central laboratory of hospitals can enhance the operation quality and efficiency of equipment,reduce the risk of equipment use,and improve the equipment service level.
5.Impact of Bias Plan dose superposition on postoperative radiotherapy planning for left breast cancer
Pan LIU ; Jianwei DONG ; Wenlong ZHAO ; Jing LIU ; Tong ZHU
Chongqing Medicine 2025;54(3):620-624
Objective To investigate the dosimetry effect of Sum Plan and Bias Plan in the Monaco planning system for the addition of compensatory agents after left breast cancer surgery.Methods Twenty-nine patients with radical left mastectomy who received radiotherapy in this hospital from March 2023 to Feb-ruary 2024 were selected as the study objects.Based on the Monaco planning system and under the same opti-mal conditions,Sum Plan and Bias Plan were used to design the second-course plan based on the first-course plan.Sum Plan C1 and Bias Plan C2 were generated to compare the dosimetry differences of intensity modula-ted radiotherapy(IMRT)plans under the two dosimetric superposition methods.Results Compared with Sum Plan C1,the conformability index(CI)in the planned target area(PTV)of Bias Plan C2 was worse,the homogeneity index(HI)was better,and the mean cardiac dose(Dmean),V5,V10,V30,V40 in the organs at risk were better than that of Sum Plan C1.The Dmean,V5,V20 and contralateral V5 in the affected lung were lower,while the V5,V10,V15,V20,V25,V30 in the normal tissue were lower,while V35 was higher,and the number of subfields and machine hops were more,the difference was statistically significant(P<0.05).Conclusion Bias Plan dose overlay method was proposed in the design of segmental radiotherapy with compensator after left breast cancer surgery.
6.Correlation analysis of WT1,BCR-ABL genes with IL-6,VEGF,PC and PS in myeloproliferative neoplasms
Jianwei DENG ; Qingren LUO ; Huiwen ZHU ; Yuping LIN
Chongqing Medicine 2025;54(6):1319-1322,1328
Objective To investigate the correlation between WT1,BCR-ABL genes and interleukin-6(IL-6),vascular endothelial growth factor(VEGF),plasma protein C(PC),plasma protein S(PS)in patients with myeloproliferative neoplasms(MPN).Methods A total of 54 MPN patients treated in this hospital from January 2021 to January 2024 were selected as the MPN group,and 54 healthy subjects undergoing physical examination during the same period were selected as the control group.The gene relative expression levels of WT1,BCR-ABL and levels of IL-6,VEGF,PC,and PS were detected and compared between the two groups.The correlations between WT1,BCR-ABL gene relative expression levels and IL-6,VEGF,PC,PS levels were analyzed,and the diagnostic efficacy of WT1 and BCR-ABL genes for MPN was evaluated by receiver operat-ing characteristic(ROC)curve.Results Compared with the control group,the gene relative expression levels of WT1,BCR-ABL and the levels of IL-6 and VEGF in the MPN group were higher,while the levels of PC and PS were lower,with statistically significant differences(P<0.05).Pearson correlation analysis showed that WT1 and BCR-ABL gene relative expression levels were positively correlated with IL-6 and VEGF levels,and negatively correlated with PC and PS levels(P<0.05).The combined use of WT1 and BCR-ABL genes has higher diagnostic efficacy for MPN than single indicators,with an area under the curve(AUC)of 0.833 and a sensitivity of 88.69%.Conclusion The relative expression levels of WT1 and BCR-ABL genes are correlated with IL-6,VEGF,PC,and PS levels in MPN patients.The combination of WT1 and BCR-ABL genes can effec-tively diagnose MPN.
7.Establishment of a nomogram model for predicting pelvic lymph node metastasis in prostate cancer based on systemic immune-infiltration inflammation index
Junzhi LIU ; Lei QIU ; Kun XU ; Jianwei LIU ; Dehua HU ; Hua ZHU ; Cheng SHEN ; Ming LU ; Jiangang CHEN
The Journal of Practical Medicine 2025;41(15):2349-2354
Objective To develop and validate a nomogram model that integrates systemic inflammatory markers to predict the likelihood of pelvic lymph node metastasis(PLNM)in prostate cancer patients prior to surgery.Methods This study retrospectively analyzed the clinical data and preoperative inflammatory markers—including neutrophil-to-lymphocyte ratio(NLR),platelet-to-lymphocyte ratio(PLR),systemic immune-inflammation index(SII),and monocyte-to-lymphocyte ratio(MLR)—of patients diagnosed with prostate cancer.Univariate and multi-variate logistic regression analyses were conducted to identify markers that were significantly associated with PLNM.Based on the results of the multivariate analysis,a nomogram was developed and its predictive accuracy was assessed using receiver operating characteristic curves(ROC)and calibration plots.Results Among the 334 enrolled patients with prostate cancer,107 were identified with PLNM.Univariate analysis revealed statistically significant differences in free prostate-specific antigen(fPSA),Gleason score,NLR,PLR,MLR,and SII between the PLNM and non-pelvic lymph node metastasis(NPLNM)groups(P<0.05).Multivariate analysis confirmed that fPSA,Gleason score,and SII were independent predictors of PLNM(P<0.05).A nomogram incorporating these predic-tors exhibited strong discriminative ability,with an area under the ROC curve(AUC)of 0.79(95%CI:0.73~0.84).Calibration analysis further demonstrated good consistency between the predicted and observed probabilities of PLNM.Conclusions This study successfully developed a nomogram model based on systemic inflammatory markers for preoperative prediction of pelvic lymph node metastasis in prostate cancer.Owing to its user-friendly design and high predictive accuracy,this tool may serve as a valuable complementary method to conventional imaging techniques,thereby supporting personalized treatment decision-making.
8.Increasing trends of hyperglycemia and diabetes in treatment-naive people living with HIV in Shenzhen from 2013 to 2019: An emerging health concern.
Liqin SUN ; Haipeng ZHU ; Man RAO ; Fang ZHAO ; Yang ZHOU ; Lukun ZHANG ; Xia SHI ; Jianwei WU ; Yun HE ; Hongzhou LU ; Jiaye LIU
Chinese Medical Journal 2025;138(16):2043-2045
9.Comparative study on accuracy of three imaging methods in diagnosis of subacromial impingement syndrome.
Linfeng ZI ; Hongfu JIN ; Jianwei ZHU ; Guoxu ZHANG ; Yao TONG ; Sijie CHEN ; Wenze SHAO ; Xin TANG
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(10):1290-1295
OBJECTIVE:
To compare the diagnostic accuracy of supraspinatus muscle outlet X-ray film, oblique sagittal multislice helical CT (MSCT), and oblique sagittal MRI in the diagnosis of subacromial impingement syndrome (SIS).
METHODS:
A retrospective analysis was conducted on the imaging data of 106 patients diagnosed with SIS between January 2023 and December 2024. The cohort consisted of 32 males and 74 females, with ages ranging from 43 to 70 years (mean, 60.19 years). All patients underwent supraspinatus muscle outlet X-ray film, MSCT, and MRI scans, with MSCT further subjected to three-dimensional reconstruction. Two experienced radiologists independently evaluated the acromion morphology in each imaging modality using the Bigliani classification system. Inter-observer reliability was assessed via Kappa statistics. The CT three-dimensional reconstructions were used as the "gold standard". The overall consistency, Kappa values, sensitivity, and specificity of the three imaging modalities were calculated. Receiver operating characteristic (ROC) curves were plotted, and the area under the curve (AUC) was computed.
RESULTS:
The inter-observer reliability for supraspinatus muscle outlet X-ray film, oblique sagittal MSCT, and oblique sagittal MRI was moderate, with Kappa values of 0.62, 0.63, and 0.55, respectively. When compared to the CT three-dimensional reconstructions as the "gold standard", the overall consistency was 88.7% (94/106), 62.3% (66/106), and 58.5% (62/106), respectively. The supraspinatus muscle outlet X-ray film showed excellent consistency (Kappa=0.77), whereas the consistency of MSCT and MRI was lower (Kappa=0.34 and 0.29, respectively). In terms of diagnostic sensitivity and specificity, the supraspinatus muscle outlet X-ray film outperformed oblique sagittal MSCT and oblique sagittal MRI in distinguishing various acromion types. ROC analysis demonstrated that the AUC for the supraspinatus muscle outlet X-ray film was consistently higher than for oblique sagittal MSCT and oblique sagittal MRI, with the highest diagnostic performance observed for type Ⅲ hooked acromion (AUC=0.939).
CONCLUSION
Supraspinatus muscle outlet X-ray film provides the highest diagnostic accuracy for acromion classification in SIS patients, particularly in identifying type Ⅲ hooked acromion, which is strongly associated with SIS. Given its superior sensitivity and consistency, it should be considered the primary screening tool. MSCT and MRI serve as valuable supplementary modalities for complex cases and preoperative evaluation.
Humans
;
Middle Aged
;
Male
;
Female
;
Shoulder Impingement Syndrome/diagnostic imaging*
;
Magnetic Resonance Imaging/methods*
;
Retrospective Studies
;
Aged
;
Adult
;
Imaging, Three-Dimensional
;
Sensitivity and Specificity
;
Tomography, Spiral Computed/methods*
;
Multidetector Computed Tomography/methods*
;
Reproducibility of Results
10.Research progress of decellularized extracellular matrix in the field of tissue engineering in thoracic and cardiac surgery
Hao CHEN ; Jianwei ZHU ; Hongcan SHI
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(06):863-868
The extracellular matrix provides a unique tissue-specific microenvironment for resident cells, supporting the essential functions required for tissue architecture and biochemical signaling. Decellularized extracellular matrix (dECM) is designed to eliminate cells that mediate immunological rejection while preserving the native tissue structure and matrix functionality. dECM has attracted significant attention in tissue engineering applications and has evolved into a novel and increasingly sophisticated biomaterial. This article summarizes representative protocols for decellularization methods, explores the latest applications of decellularized tissue-derived materials and bioinks in the field of cardiothoracic surgery, analyzes the current challenges and issues confronting dECM, and discusses future perspectives for its development.

Result Analysis
Print
Save
E-mail