1.Effect of Xiaoqinglong Decoction (小青龙汤) on Th2 Immune Responses and Nasal Mucosal TSLP/OX40L Pathway in Allergic Rhinitis Model Rats
Yimeng CHEN ; Yuye CHEN ; Guangchun YU ; Bei CHEN ; Jianwei ZHANG ; Shanshan DING ; Xiaoting YANG ; Baifan YU ; Yating CAI ; Xuejuan LIN ; Mengting ZHANG
Journal of Traditional Chinese Medicine 2026;67(9):994-1002
ObjectiveTo explore the potential mechanism of Xiaoqinglong Decoction (小青龙汤, XD) in the treatment of allergic rhinitis. MethodsForty-five rats were randomly assigned to a control group, a model group, a loratadine group, low-, medium- and high-dose XD groups, and low-, medium- and high-dose Mahuang Decoction and Cang'erzi Powder (麻黄汤合苍耳子散, MDCP) groups. Except for the control group, rats were administered with ovalbumin (OVA) and aluminum hydroxide via intraperitoneal injection for 14 days to establish an allergic rhinitis model. After the 14th-day injection, nasal stimulation was continued with 20 μl of 10% OVA solution to maintain the model. Rats in the control group and the model group received 10 ml/(kg·d) of saline, whereas those in the loratadine group were administered with 0.9 mg/(kg·d) of loratadine. The low-, medium- and high-dose XD groups were administered XD at the dose of 2.7, 5.4, and 10.8 g/(kg·d), respectively. The low-, medium- and high-dose MDCP groups were administered MDCP at the dose of 2.43, 4.86, and 9.72 g/(kg·d), respectively. All treatments were administered by gavage once daily for 7 consecutive days. One hour after the final gavage, nasal symptom scores were recorded for all group of rats. The next day, serum levels of immunoglobulin E (IgE), interleukin-4 (IL-4), and interleukin-13 (IL-13) were measured. HE staining was used to observe the pathological morphology of the nasal mucosal tissue. Quantitative reverse transcription PCR (RT-qPCR) and Western Blot were performed to assess mRNA and protein expression of thymic stromal lymphopoietin (TSLP) and OX40 ligand (OX40L) in the nasal mucosa. ResultsCompared to the control group, total nasal symptom score in the model group significantly increased (P<0.01). HE staining revealed disrupted and adhered cilia, thickened basement membranes, and extensive inflammatory cell infiltration in the nasal mucosa. Serum levels of total IgE, IL-4, and IL-13, as well as TSLP and OX40L mRNA and protein expression in the nasal mucosa, were significantly elevated in the model group (P<0.05 or P<0.01). Compared to the model group, the total nasal symptom scores in all drug intervention groups were significantly reduced; the serum total IgE levels in the loratadine group, the low- and medium-dose XD groups, and the low- and high-dose MDCP groups were significantly reduced; and the serum levels of IL-4 and IL-13 in the high-dose XD group and the high-dose MDCP group decreased (P<0.05 or P<0.01). Nasal mucosal structure was improved. Except for the low-dose MDCP group, all other intervention groups showed a significant reduction in TSLP and OX40L mRNA expression in the nasal mucosa (P<0.01). All doses of XD and the medium- and high-dose MDCP groups significantly decreased the protein levels of TSLP and OX40L (P<0.05). The medium-dose XD group exhibited more improvement of nasal symptom scores and greater suppression of expression of TSLP and OX40L mRNA, and TSLP protein levels compared to the loratadine group (P<0.05). ConclusionXD may protect nasal mucosa of rats and alleviate allergic rhinitis by suppressing the TSLP/OX40L pathway, thereby attenuating Th2-mediated immune responses.
2.Effect of Xiaoqinglong Decoction (小青龙汤) on Th2 Immune Responses and Nasal Mucosal TSLP/OX40L Pathway in Allergic Rhinitis Model Rats
Yimeng CHEN ; Yuye CHEN ; Guangchun YU ; Bei CHEN ; Jianwei ZHANG ; Shanshan DING ; Xiaoting YANG ; Baifan YU ; Yating CAI ; Xuejuan LIN ; Mengting ZHANG
Journal of Traditional Chinese Medicine 2026;67(9):994-1002
ObjectiveTo explore the potential mechanism of Xiaoqinglong Decoction (小青龙汤, XD) in the treatment of allergic rhinitis. MethodsForty-five rats were randomly assigned to a control group, a model group, a loratadine group, low-, medium- and high-dose XD groups, and low-, medium- and high-dose Mahuang Decoction and Cang'erzi Powder (麻黄汤合苍耳子散, MDCP) groups. Except for the control group, rats were administered with ovalbumin (OVA) and aluminum hydroxide via intraperitoneal injection for 14 days to establish an allergic rhinitis model. After the 14th-day injection, nasal stimulation was continued with 20 μl of 10% OVA solution to maintain the model. Rats in the control group and the model group received 10 ml/(kg·d) of saline, whereas those in the loratadine group were administered with 0.9 mg/(kg·d) of loratadine. The low-, medium- and high-dose XD groups were administered XD at the dose of 2.7, 5.4, and 10.8 g/(kg·d), respectively. The low-, medium- and high-dose MDCP groups were administered MDCP at the dose of 2.43, 4.86, and 9.72 g/(kg·d), respectively. All treatments were administered by gavage once daily for 7 consecutive days. One hour after the final gavage, nasal symptom scores were recorded for all group of rats. The next day, serum levels of immunoglobulin E (IgE), interleukin-4 (IL-4), and interleukin-13 (IL-13) were measured. HE staining was used to observe the pathological morphology of the nasal mucosal tissue. Quantitative reverse transcription PCR (RT-qPCR) and Western Blot were performed to assess mRNA and protein expression of thymic stromal lymphopoietin (TSLP) and OX40 ligand (OX40L) in the nasal mucosa. ResultsCompared to the control group, total nasal symptom score in the model group significantly increased (P<0.01). HE staining revealed disrupted and adhered cilia, thickened basement membranes, and extensive inflammatory cell infiltration in the nasal mucosa. Serum levels of total IgE, IL-4, and IL-13, as well as TSLP and OX40L mRNA and protein expression in the nasal mucosa, were significantly elevated in the model group (P<0.05 or P<0.01). Compared to the model group, the total nasal symptom scores in all drug intervention groups were significantly reduced; the serum total IgE levels in the loratadine group, the low- and medium-dose XD groups, and the low- and high-dose MDCP groups were significantly reduced; and the serum levels of IL-4 and IL-13 in the high-dose XD group and the high-dose MDCP group decreased (P<0.05 or P<0.01). Nasal mucosal structure was improved. Except for the low-dose MDCP group, all other intervention groups showed a significant reduction in TSLP and OX40L mRNA expression in the nasal mucosa (P<0.01). All doses of XD and the medium- and high-dose MDCP groups significantly decreased the protein levels of TSLP and OX40L (P<0.05). The medium-dose XD group exhibited more improvement of nasal symptom scores and greater suppression of expression of TSLP and OX40L mRNA, and TSLP protein levels compared to the loratadine group (P<0.05). ConclusionXD may protect nasal mucosa of rats and alleviate allergic rhinitis by suppressing the TSLP/OX40L pathway, thereby attenuating Th2-mediated immune responses.
3.Comparative Analysis of Clinical Efficacy of Traditional Chinese Medicine Manipulative Reduction Combined with Small Splint Fixation Versus Surgical Treatment for Type A Distal Radius Fracture
Yang SHAO ; Zihan WANG ; Jianwei WANG ; Guoda DAI ; Hengyan CUI ; Zhen HUA ; Tingchen ZHU ; Shaoshuo LI ; Jun MAO ; Fenghua CHEN ; Shuai TAO ; Mao WU
Journal of Traditional Chinese Medicine 2026;67(10):1078-1085
ObjectiveTo compare the clinical efficacy of traditional Chinese medicine (TCM) manipulative reduction combined with small splint fixation versus surgical treatment for type A distal radius fracture (DRF) and to explore the factors influencing the choice of treatment. MethodsA multi-center retrospective study was conducted, collecting data from 1237 type A DRF patients treated in 11 hospitals in Jiangsu province from September, 2023 to April, 2025. Among them, 851 patients in the TCM group received manipulative reduction combined with small splint fixation, and 386 patients in the surgical group underwent open reduction and internal fixation. Visual analog scale (VAS) scores for pain and radiographic indicators including palmar tilt, ulnar deviation, and radial height were compared before treatment, 5-7 days after treatment, and 4-6 weeks after treatment. The wrist joint function scores including Dienst and Gartland-Werley scores at 12 weeks after treatment were recorded. Subgroup analysis was conducted for the excellent rate of Dienst and Gartland-Werley scores, stratified by age (<50, 50-59, 60-69, ≥70 years old) and AO subtypes (A1, A2, A3). A multivariate logistic regression model was used to identify independent factors influencing treatment choice. ResultsOn 5-7 days after treatment, the surgical group had lower VAS scores than the TCM group, while 4-6 weeks after treatment, the TCM group showed lower VAS scores than the surgical group (P<0.01). In terms of radiographic indicators, except for the palmar tilt before treatment being higher in the surgical group than in the TCM group (P<0.01), there were no significant differences in palmar tilt, ulnar deviation, and radial height at other timepoints (P>0.05). Twelve weeks after treatment, the surgical group had a higher average Gartland-Werley score and the excellent rate than the TCM group (P<0.01). Subgroup analysis showed that in patients with A2 type DRF aged 50-59 and 60-69 years old, the excellent rates of Dienst and Gartland-Werley scores in the TCM group were higher than those in the surgical group (P<0.05). Multivariate logistic regression analysis revealed that age, palmar tilt, ulnar deviation, and the degree of swelling on the affected side were independent factors influencing the choice of treatment (P<0.05). ConclusionBoth TCM manipulative reduction combined with small splint fixation and surgical treatment for type A DRF can achieve good therapeutic effects. TCM manipulative reduction combined with small splint fixation has certain advantages in medium- and long-term pain relief, especially in elderly patients, where wrist joint function recovery is more stable. Age, palmar tilt, ulnar deviation, and swelling degree are the main factors influencing the treatment choice.
4.Finite element analysis comparing lumbar fusion and artificial intervertebral disc replacement
Jingang ZHAO ; Liping LIU ; Jianwei CHEN
Chinese Journal of Tissue Engineering Research 2026;30(3):553-560
BACKGROUND:Lumbar degenerative disease is a disease of the musculoskeletal system that primarily affects the intervertebral structures,and the disease is treated with lumbar fusion and disc replacement.OBJECTIVE:To conduct comparative analysis of the differences between lumbar fusion,mechanical lumbar disc prosthesis replacement,and viscoelastic lumbar disc prosthesis replacement.METHODS:The computerized tomography images of a healthy adult were used to construct a finite element model of the L2-L5 normal lumbar spine with Mimic,Geomagic,and Ansys software.The equipment required for lumbar fusion and lumbar spine replacement was constructed using modeling software,and the L3-L4 segment of the lumbar spine was processed according to the surgical requirements for lumbar fusion and intervertebral disc replacement,creating the corresponding finite element model.Specific boundary conditions were applied to extract the mobility of each lumbar spine segment,the stresses on the neighboring intervertebral discs,and the stresses on the prosthesis lining.RESULTS AND CONCLUSION:(1)Compared with the preoperative period,the maximum stress in the upper neighboring discs increased by 64.09%and 39.79%in the forward flexion and lateral bending states if the original mobility was maintained after lumbar fusion surgery.The maximum stress in the lower neighboring discs increased by 24.39%and 20.98%in forward flexion and lateral bending.This suggested that the upper adjacent discs would suffer greater stress changes than the lower adjacent discs during heavy physical labor.(2)Disc replacement did not show significant changes in adjacent disc stress,with mechanical prosthesis replacement slightly reducing adjacent disc stress,while viscoelastic prosthesis replacement was more in line with the biological properties of the disc,with maximum adjacent disc stress similar to that of the preoperative period.(3)In terms of stability,the mechanical prosthesis replacement segment showed a 51.67%increase in range of motion in the lateral bending state and a 53.27%increase in range of motion in the posterior extension state,whereas the viscoelastic prosthesis was better able to maintain mobility in the replacement segment.(4)In addition,the stresses in the liner of the mechanical prosthesis were mainly concentrated in the edge region,and this stress distribution may lead to edge wear and thus affect the service life of the prosthesis.
5.Finite element analysis comparing lumbar fusion and artificial intervertebral disc replacement
Jingang ZHAO ; Liping LIU ; Jianwei CHEN
Chinese Journal of Tissue Engineering Research 2026;30(3):553-560
BACKGROUND:Lumbar degenerative disease is a disease of the musculoskeletal system that primarily affects the intervertebral structures,and the disease is treated with lumbar fusion and disc replacement.OBJECTIVE:To conduct comparative analysis of the differences between lumbar fusion,mechanical lumbar disc prosthesis replacement,and viscoelastic lumbar disc prosthesis replacement.METHODS:The computerized tomography images of a healthy adult were used to construct a finite element model of the L2-L5 normal lumbar spine with Mimic,Geomagic,and Ansys software.The equipment required for lumbar fusion and lumbar spine replacement was constructed using modeling software,and the L3-L4 segment of the lumbar spine was processed according to the surgical requirements for lumbar fusion and intervertebral disc replacement,creating the corresponding finite element model.Specific boundary conditions were applied to extract the mobility of each lumbar spine segment,the stresses on the neighboring intervertebral discs,and the stresses on the prosthesis lining.RESULTS AND CONCLUSION:(1)Compared with the preoperative period,the maximum stress in the upper neighboring discs increased by 64.09%and 39.79%in the forward flexion and lateral bending states if the original mobility was maintained after lumbar fusion surgery.The maximum stress in the lower neighboring discs increased by 24.39%and 20.98%in forward flexion and lateral bending.This suggested that the upper adjacent discs would suffer greater stress changes than the lower adjacent discs during heavy physical labor.(2)Disc replacement did not show significant changes in adjacent disc stress,with mechanical prosthesis replacement slightly reducing adjacent disc stress,while viscoelastic prosthesis replacement was more in line with the biological properties of the disc,with maximum adjacent disc stress similar to that of the preoperative period.(3)In terms of stability,the mechanical prosthesis replacement segment showed a 51.67%increase in range of motion in the lateral bending state and a 53.27%increase in range of motion in the posterior extension state,whereas the viscoelastic prosthesis was better able to maintain mobility in the replacement segment.(4)In addition,the stresses in the liner of the mechanical prosthesis were mainly concentrated in the edge region,and this stress distribution may lead to edge wear and thus affect the service life of the prosthesis.
6.Comparison of super-mini and standard percutaneous nephrolithotomy in treating 2-4 cm renal calculi
Jianwei LI ; Zixiong CAI ; Yuanwei CHEN ; Jianjun LIU
Journal of Modern Urology 2026;31(3):224-229
Objective To evaluate the efficacy and safety of super-mini percutaneous nephrolithotomy(SMP)and standard percutaneous nephrolithotomy(sPCNL)in the treatment of 2-4 cm renal calculi, so as to provide reference for the management of medium-sized renal calculi. Methods A retrospective analysis was conducted on 168 patients with 2-4 cm renal calculi who underwent either SMP or sPCNL at our hospital during Sep. 2020 and Mar. 2025. The patients were divided into the SMP group(n=85)and sPCNL group(n=83). The baseline characteristics, stone features, operation time, perioperative complications, transfusion rate, postoperative hemoglobin drop, pain score, hospital stay, and stone-free rate(SFR)were compared between the two groups. Results There were no significant differences in baseline characteristics, stone features, and SFR between the two groups(P>0.05). Compared to the sPCNL group, the SMP group had a longer operation time [(71.76±22.49)vs.(64.22±15.01)min, P=0.034]. However, it had lower postoperative pain score [(2.51 ±0.85)vs.(4.11±0.47), P<0.001], shorter hospital stay [(3.16±1.45)vs.(4.30±1.06)days, P<0.001], lower hospitalization costs [(19982.67±4267.80)vs.(21688.53±4575.74)RMB, P=0.004], a slighter decrease in hemoglobin [(6.64±10.56)vs.(12.22±11.50)g/L, P=0.032], and a significantly higher tubeless rate(83.53% vs. 0%, P<0.001). There was no statistically significant difference in the overall complication rate between the two groups(P>0.05). Conclusion For 2—4 cm renal calculi, SMP achieves a comparable SFR as sPCNL. Although the operation time with SMP is slightly longer, it offers significant advantages, including reduced postoperative pain, shorter hospitalization, lower costs, less bleeding, and a higher tubeless rate. SMP is a valuable technique worthy of broader clinical application.
7.USP20 as a super-enhancer-regulated gene drives T-ALL progression via HIF1A deubiquitination.
Ling XU ; Zimu ZHANG ; Juanjuan YU ; Tongting JI ; Jia CHENG ; Xiaodong FEI ; Xinran CHU ; Yanfang TAO ; Yan XU ; Pengju YANG ; Wenyuan LIU ; Gen LI ; Yongping ZHANG ; Yan LI ; Fenli ZHANG ; Ying YANG ; Bi ZHOU ; Yumeng WU ; Zhongling WEI ; Yanling CHEN ; Jianwei WANG ; Di WU ; Xiaolu LI ; Yang YANG ; Guanghui QIAN ; Hongli YIN ; Shuiyan WU ; Shuqi ZHANG ; Dan LIU ; Jun-Jie FAN ; Lei SHI ; Xiaodong WANG ; Shaoyan HU ; Jun LU ; Jian PAN
Acta Pharmaceutica Sinica B 2025;15(9):4751-4771
T-cell acute lymphoblastic leukemia (T-ALL) is a highly aggressive hematologic malignancy with a poor prognosis, despite advancements in treatment. Many patients struggle with relapse or refractory disease. Investigating the role of the super-enhancer (SE) regulated gene ubiquitin-specific protease 20 (USP20) in T-ALL could enhance targeted therapies and improve clinical outcomes. Analysis of histone H3 lysine 27 acetylation (H3K27ac) chromatin immunoprecipitation sequencing (ChIP-seq) data from six T-ALL cell lines and seven pediatric samples identified USP20 as an SE-regulated driver gene. Utilizing the Cancer Cell Line Encyclopedia (CCLE) and BloodSpot databases, it was found that USP20 is specifically highly expressed in T-ALL. Knocking down USP20 with short hairpin RNA (shRNA) increased apoptosis and inhibited proliferation in T-ALL cells. In vivo studies showed that USP20 knockdown reduced tumor growth and improved survival. The USP20 inhibitor GSK2643943A demonstrated similar anti-tumor effects. Mass spectrometry, RNA-Seq, and immunoprecipitation revealed that USP20 interacted with hypoxia-inducible factor 1 subunit alpha (HIF1A) and stabilized it by deubiquitination. Cleavage under targets and tagmentation (CUT&Tag) results indicated that USP20 co-localized with HIF1A, jointly modulating target genes in T-ALL. This study identifies USP20 as a therapeutic target in T-ALL and suggests GSK2643943A as a potential treatment strategy.
8.Design and application of a height measuring instrument for ventricular drainage catheter.
Qingchen ZHAI ; Guanjie CHEN ; Jianwei LI ; Junping LI ; Lu MA
Chinese Critical Care Medicine 2025;37(3):294-296
Ventriculostomy drainage is one of the commonly used surgical techniques in neurocritical care, which can relieve intracranial hypertension and facilitate postoperative cerebrospinal fluid and intracranial pressure monitoring. By placing a drainage tube in the ventricle, blood and fluid accumulation within the ventricle are drained out of the brain, reducing intracranial pressure and preventing brain tissue damage. Clinically, the speed of ventriculostomy drainage is often controlled by measuring the height difference between the drainage opening and the plane of the ventricle, ensuring the safe and effective reduction of intracranial pressure, facilitating the implementation of clinical management plans, and preventing complications. However, how to easily, safely, and effectively measure the height difference between the drainage opening and the ventricular plane remains a challenge in nursing management. Currently, clinical practice often uses a tape measure to measure the height of the ventriculostomy drainage, a process that is cumbersome and time-consuming and susceptible to human error, leading to inaccurate measurements. However, the challenge of easily, safely, and effectively detecting the height difference between the drainage opening and the ventricular plane remains a difficult problem in nursing management. To address this issue, the medical and nursing staff of the intensive care unit (ICU) at Zhongda Hospital, Southeast University, jointly designed a novel ventriculostomy drainage height measurement device, which has been granted a national utility model patent (patent number: ZL 2022 2 1400920.9). This device can be easily and securely fixed to an infusion stand. Using a level within the horizontal measuring part and a rotational structure, the vertical measuring part of the device is adjusted to be perpendicular to the ground. After opening the limit clip, the horizontal part is manually guided down to the appropriate height. The front end of the horizontal measuring part is then extended towards the patient's head, and after confirming the position, the limit clip is closed. At this point, the horizontal height difference between the drainage opening and the ventricular plane can be accurately measured. When temporarily finishing the height measurement of the drainage tube, the device can be folded and stored by retracting the horizontal measuring part and rotating components. This measuring device has a simple operation process, which can improve the accuracy and reliability of the drainage height measurement, enhance treatment outcomes and patient safety, reduce the workload of nursing staff, and has certain clinical promotion and practical value.
Humans
;
Ventriculostomy/methods*
;
Drainage/instrumentation*
;
Equipment Design
;
Cerebral Ventricles
9.Comparative study on accuracy of three imaging methods in diagnosis of subacromial impingement syndrome.
Linfeng ZI ; Hongfu JIN ; Jianwei ZHU ; Guoxu ZHANG ; Yao TONG ; Sijie CHEN ; Wenze SHAO ; Xin TANG
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(10):1290-1295
OBJECTIVE:
To compare the diagnostic accuracy of supraspinatus muscle outlet X-ray film, oblique sagittal multislice helical CT (MSCT), and oblique sagittal MRI in the diagnosis of subacromial impingement syndrome (SIS).
METHODS:
A retrospective analysis was conducted on the imaging data of 106 patients diagnosed with SIS between January 2023 and December 2024. The cohort consisted of 32 males and 74 females, with ages ranging from 43 to 70 years (mean, 60.19 years). All patients underwent supraspinatus muscle outlet X-ray film, MSCT, and MRI scans, with MSCT further subjected to three-dimensional reconstruction. Two experienced radiologists independently evaluated the acromion morphology in each imaging modality using the Bigliani classification system. Inter-observer reliability was assessed via Kappa statistics. The CT three-dimensional reconstructions were used as the "gold standard". The overall consistency, Kappa values, sensitivity, and specificity of the three imaging modalities were calculated. Receiver operating characteristic (ROC) curves were plotted, and the area under the curve (AUC) was computed.
RESULTS:
The inter-observer reliability for supraspinatus muscle outlet X-ray film, oblique sagittal MSCT, and oblique sagittal MRI was moderate, with Kappa values of 0.62, 0.63, and 0.55, respectively. When compared to the CT three-dimensional reconstructions as the "gold standard", the overall consistency was 88.7% (94/106), 62.3% (66/106), and 58.5% (62/106), respectively. The supraspinatus muscle outlet X-ray film showed excellent consistency (Kappa=0.77), whereas the consistency of MSCT and MRI was lower (Kappa=0.34 and 0.29, respectively). In terms of diagnostic sensitivity and specificity, the supraspinatus muscle outlet X-ray film outperformed oblique sagittal MSCT and oblique sagittal MRI in distinguishing various acromion types. ROC analysis demonstrated that the AUC for the supraspinatus muscle outlet X-ray film was consistently higher than for oblique sagittal MSCT and oblique sagittal MRI, with the highest diagnostic performance observed for type Ⅲ hooked acromion (AUC=0.939).
CONCLUSION
Supraspinatus muscle outlet X-ray film provides the highest diagnostic accuracy for acromion classification in SIS patients, particularly in identifying type Ⅲ hooked acromion, which is strongly associated with SIS. Given its superior sensitivity and consistency, it should be considered the primary screening tool. MSCT and MRI serve as valuable supplementary modalities for complex cases and preoperative evaluation.
Humans
;
Middle Aged
;
Male
;
Female
;
Shoulder Impingement Syndrome/diagnostic imaging*
;
Magnetic Resonance Imaging/methods*
;
Retrospective Studies
;
Aged
;
Adult
;
Imaging, Three-Dimensional
;
Sensitivity and Specificity
;
Tomography, Spiral Computed/methods*
;
Multidetector Computed Tomography/methods*
;
Reproducibility of Results
10.Analysis of the long-term efficacy of surgical treatment and endoscopic resection for early gastric carcinoma based on the SEER database
Jie HE ; Xinyang LIU ; Hua GAO ; Peng LÜ ; Qi JIANG ; Weifeng CHEN ; Jianwei HU
Chinese Journal of Clinical Medicine 2025;32(5):761-767
Objective To compare the long-term prognosis differences between surgical radical resection and endoscopic resection for early gastric cancer patients based on the SEER database. Methods A total of 1 437 patients with stage Tis to T1b gastric adenocarcinoma were selected from the SEER database from January 1, 2004 to December 31, 2013. They were divided into a surgery group (n=1 257) and an endoscope group (n=180) according to the treatment method. Kaplan-Meier survival curve and Cox regression model were used to analyze survival outcomes. Results The patients in the surgery group were younger than those in the endoscope group ([67.63±12.97] years old vs [71.29±10.82] years old), with higher rates of T1 stage (97.45% vs 87.78%) and lymph node metastasis (19.73% vs 5.00%, all P<0.001). The median follow-up time for all patients was 37 (15, 66) months, and the mortality rate of gastric cancer in the endoscope group was lower than that in the surgery group (23.33% vs 27.13%, P<0.001). Univariate Cox analysis showed that treatment modality, age, sex, T stage, lymph node metastasis were all associated with early gastric cancer mortality (all P<0.05), and the risk of death in the endoscope group was 43% of that in the surgery group (HR=0.43, P=0.015). After adjusting for multiple factors, there was no statistically significant difference in mortality risk between the two groups (P=0.067), but after excluding lymph node positive patients, the mortality risk in the endoscope group was 46% of that in the surgery group (HR=0.46, P=0.048). Conclusions For early gastric cancer patients with negative lymph nodes, endoscopic resection may provide better survival benefits than surgical procedures, suggesting that it can be the preferred treatment strategy for patients with low risk of lymph node metastasis.

Result Analysis
Print
Save
E-mail