1.Establishment of a"#-shaped"method of radiotherapy marking of reflecting the range of respiratory motion in radiotherapy
Chenlei GUO ; Ying CAO ; Xin FENG ; Kaixuan ZHANG ; Zhen WANG ; Mingjian SUN ; Yongli SONG ; Xing LIU ; Wenyang LIU ; Jianrong DAI
China Medical Equipment 2025;22(8):52-56
Objective:To propose a novel radiotherapy marking method-the"#"-character method,which aimed at improving the accuracy and repeatability of positioning during radiotherapy.Methods:A specially"cross-shaped"stamp was designed by this study,which consisted of a handheld square base with a"cross-shaped"protrusion.Using this stamp,the extreme positions of end-expiration and end-inspiration were marked respectively at the laser-guided regions on the directly above and bilateral sides of the patient's body,and each position was printed a"+"character.Finally,a"#-shaped"signal was formed,which represented the full range of respiratory motion of patients.The study included two parts:surface displacement caused by respiration was simulated through a three-dimensional(3D)motion platform,which was used to conduct a phantom experiment for anthropomorphic dummy,A randomized controlled study involving 40 patients,who were treated between January and June 2024 at the Department of Radiotherapy,Cancer Hospital,Chinese Academy of Medical Sciences,were conducted.The cohort included 20 patients with breast tumor(Positioning the outer contour by exposing the chest)and 20 patients with thoracic tumor(fixed position of using thermoplastic film).These patients were divided into two groups for comparison,which received respectively the"#-shaped"method and the conventional"+-shaped"method.The cone-beam computed tomography(CBCT)images before treatment were used to compare the influences of the two kinds of marking methods on the positioning errors of patients with breast tumor and patients with thoracic tumor.Then,the statistical analysis was used to assess precision and accuracy of positioning.Results:The result of phantom experiment indicated that the positioning error of the"#-shaped"method was significantly better than that of the"+-shaped"method under various parameters of respiratory movement.Under three kinds of different respiratory cycles(3,4,and 5 seconds)and amplitudes(8,12,and 15 mm),the positioning errors of the"#-shaped"method were respectively(0.15±0.04)cm,(0.19±0.05)cm and(0.35±0.14)cm,while the"+-shaped"method were respectively(0.42±0.16)cm,(0.64±0.28)cm and(0.88±0.37)cm,and the differences were statistically significant(t=8.347,3.416,2.901,P<0.05).The results of actual patients indicated the positioning error[(0.97±0.32)cm]of the"#-shaped"method was significantly lower than[(1.62±0.47)cm]of the"+-shaped"method for patients with breast tumor(Positioning the outer contour by exposing the chest),and the difference was significant(t=3.615,P<0.05).On the other hand,the positioning error[(0.69±0.24)cm]of the"#-shaped"method was significantly lower than[(0.97±0.39)cm]of the"+-shaped"method for patients with thoracic tumor(fixed position of using thermoplastic film),and the difference also was significant(t=1.934,P<0.05).Conclusion:Compared to the conventional"+-shaped"method,the"#-shaped"method appears higher accuracy and repeatability during the positioning process of radiotherapy,which especially is suitable to the treatment for breast tumor and thoracic tumor that need accurately control the influences of respiratory motion.
2.Tubeless subxiphoid uniportal video-assisted thoracoscopic surgery with percutaneous suspension technique via balance-shaped sternal elevation device in anterior mediastinal masses
Junmin ZHU ; Junjie WANG ; Jianming YUE ; Yixin SUN ; Yichen LIU ; Lei WANG ; Lin LIN ; Jie LI ; Jinlan ZHAO ; Xuehua TU ; Ningying DING ; Jianrong HU ; Chunmei HE ; Leilei TIAN ; Hongtao TANG ; Jiasheng ZHAO ; Cheng CHEN ; Yongxiang SONG ; Yunwei TIAN ; Yong XIAO ; Kaidi LI ; Lin MA ; Yun WANG ; Longqi CHEN ; Dong TIAN
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(11):1603-1609
Objective To assess the clinical value of a novel surgical technique—Tubeless subxiphoid uniportal video-assisted thoracoscopic surgery with percutaneous suspension technique via balance-shaped sternal elevation device in the resection of anterior mediastinal masses. Methods Patients who underwent tubeless subxiphoid uniportal video-assisted thoracoscopic surgery via balance-shaped sternal elevation device in anterior mediastinal masses process at the Department of Thoracic Surgery, West China Hospital, Sichuan University from March to April 2025 were included, and their clinical data were analyzed. Results A total of 4 patients were included, with 2 males and 2 females, aged 58-75 years. The diameter of the tumor was 2.5-3.0 cm. The operation time was 60.0-150.0 min, intraoperative blood loss was 5-10 mL, pain score on the 3rd day after surgery was 0 points, and postoperative hospital stay was 2-3 days. All patients achieved complete resection of the masses and thymus without perioperative complications. Conclusion The tubeless subxiphoid uniportal video-assisted thoracoscopic surgery with percutaneous suspension technique via balance-shaped sternal elevation device technique optimizes surgical visualization and instrument maneuverability while avoiding complications related to conventional anesthesia and tubing, thereby markedly enhancing the minimally invasive profile of anterior mediastinal masses resections. In addition to maintaining procedural safety, this approach effectively reduces postoperative pain and accelerates patient recovery, highlighting its potential for widespread clinical adoption.
3.Application of ArcherQA for independent dose verification of SRT plans for CyberKnife
Xuyao YU ; Yuwen WANG ; Yang DONG ; Daguang ZHANG ; Yongchun SONG ; Qiang REN ; Xi PEI ; Zhiyong YUAN ; Wei WANG ; Jianrong DAI
Chinese Journal of Radiation Oncology 2025;34(11):1139-1145
Objective:To evaluate the feasibility of using the domestic ArcherQA system for fast and simplified independent verification of CyberKnife (CK) stereotactic radiotherapy (SRT) plans.Methods:SRT plans of 57 patients treated with CK at Tianjin Medical University Cancer Institute and Hospital from August 2021 to August 2022 were retrospectively analyzed, including 15 intracranial, 30 pulmonary, and 12 abdominal tumors cases. Point-dose and planar-dose verifications were performed using an ionization chamber and radiochromic films embedded in a homogeneous phantom, and the results were compared with those calculated by the treatment planning system (TPS). The localization CT images and corresponding SRT plans were imported into the ArcherQA system for independent dose verification and analysis. The correlation between ArcherQA results and phantom measurements was analyzed, with comparisons of target mean dose differences and γ pass rates.Results:Phantom measurement results showed, the measured point-dose differences for intracranial, lung, and abdominal plans were -0.94% ± 3.22%, 1.92% ± 2.05%, and 2.12% ± 0.77%, respectively. The mean dose differences in target dose calculation between ArcherQA and TPS: intracranial in the gross tumor volume (GTV) regions were 0.34% ± 2.21%, lung tumor GTV were -2.47% ± 2.46%, and abdominal tumor GTV were 0.80% ± 2.61%, respectively. Among them, the abdominal GTV region showed the highest correlation between ArcherQA and measured results ( r=0.78). The average two-dimensional γ pass rates (2 mm/2%, threshold=10%) measured using phantom films were 95.92% ± 2.35% for intracranial, 95.70% ± 2.74% for lung, and 96.74% ± 3.41% for abdominal tumors plans, respectively. The three-dimensional ArcherQA results showed comparable γ pass rates (1 mm/2%, threshold=10%) for lung and abdominal GTV and PTV regions, with similar medians and data dispersion to film measurements. Conclusions:The ArcherQA system enables rapid and efficient independent dose verification of CK SRT plans without the need for additional hardware. The verification results show good correlation with phantom measurements, supporting its potential as an auxiliary quality assurance tool in clinical CK SRT implementation.
4.Establishment of a"#-shaped"method of radiotherapy marking of reflecting the range of respiratory motion in radiotherapy
Chenlei GUO ; Ying CAO ; Xin FENG ; Kaixuan ZHANG ; Zhen WANG ; Mingjian SUN ; Yongli SONG ; Xing LIU ; Wenyang LIU ; Jianrong DAI
China Medical Equipment 2025;22(8):52-56
Objective:To propose a novel radiotherapy marking method-the"#"-character method,which aimed at improving the accuracy and repeatability of positioning during radiotherapy.Methods:A specially"cross-shaped"stamp was designed by this study,which consisted of a handheld square base with a"cross-shaped"protrusion.Using this stamp,the extreme positions of end-expiration and end-inspiration were marked respectively at the laser-guided regions on the directly above and bilateral sides of the patient's body,and each position was printed a"+"character.Finally,a"#-shaped"signal was formed,which represented the full range of respiratory motion of patients.The study included two parts:surface displacement caused by respiration was simulated through a three-dimensional(3D)motion platform,which was used to conduct a phantom experiment for anthropomorphic dummy,A randomized controlled study involving 40 patients,who were treated between January and June 2024 at the Department of Radiotherapy,Cancer Hospital,Chinese Academy of Medical Sciences,were conducted.The cohort included 20 patients with breast tumor(Positioning the outer contour by exposing the chest)and 20 patients with thoracic tumor(fixed position of using thermoplastic film).These patients were divided into two groups for comparison,which received respectively the"#-shaped"method and the conventional"+-shaped"method.The cone-beam computed tomography(CBCT)images before treatment were used to compare the influences of the two kinds of marking methods on the positioning errors of patients with breast tumor and patients with thoracic tumor.Then,the statistical analysis was used to assess precision and accuracy of positioning.Results:The result of phantom experiment indicated that the positioning error of the"#-shaped"method was significantly better than that of the"+-shaped"method under various parameters of respiratory movement.Under three kinds of different respiratory cycles(3,4,and 5 seconds)and amplitudes(8,12,and 15 mm),the positioning errors of the"#-shaped"method were respectively(0.15±0.04)cm,(0.19±0.05)cm and(0.35±0.14)cm,while the"+-shaped"method were respectively(0.42±0.16)cm,(0.64±0.28)cm and(0.88±0.37)cm,and the differences were statistically significant(t=8.347,3.416,2.901,P<0.05).The results of actual patients indicated the positioning error[(0.97±0.32)cm]of the"#-shaped"method was significantly lower than[(1.62±0.47)cm]of the"+-shaped"method for patients with breast tumor(Positioning the outer contour by exposing the chest),and the difference was significant(t=3.615,P<0.05).On the other hand,the positioning error[(0.69±0.24)cm]of the"#-shaped"method was significantly lower than[(0.97±0.39)cm]of the"+-shaped"method for patients with thoracic tumor(fixed position of using thermoplastic film),and the difference also was significant(t=1.934,P<0.05).Conclusion:Compared to the conventional"+-shaped"method,the"#-shaped"method appears higher accuracy and repeatability during the positioning process of radiotherapy,which especially is suitable to the treatment for breast tumor and thoracic tumor that need accurately control the influences of respiratory motion.
5.Application of ArcherQA for independent dose verification of SRT plans for CyberKnife
Xuyao YU ; Yuwen WANG ; Yang DONG ; Daguang ZHANG ; Yongchun SONG ; Qiang REN ; Xi PEI ; Zhiyong YUAN ; Wei WANG ; Jianrong DAI
Chinese Journal of Radiation Oncology 2025;34(11):1139-1145
Objective:To evaluate the feasibility of using the domestic ArcherQA system for fast and simplified independent verification of CyberKnife (CK) stereotactic radiotherapy (SRT) plans.Methods:SRT plans of 57 patients treated with CK at Tianjin Medical University Cancer Institute and Hospital from August 2021 to August 2022 were retrospectively analyzed, including 15 intracranial, 30 pulmonary, and 12 abdominal tumors cases. Point-dose and planar-dose verifications were performed using an ionization chamber and radiochromic films embedded in a homogeneous phantom, and the results were compared with those calculated by the treatment planning system (TPS). The localization CT images and corresponding SRT plans were imported into the ArcherQA system for independent dose verification and analysis. The correlation between ArcherQA results and phantom measurements was analyzed, with comparisons of target mean dose differences and γ pass rates.Results:Phantom measurement results showed, the measured point-dose differences for intracranial, lung, and abdominal plans were -0.94% ± 3.22%, 1.92% ± 2.05%, and 2.12% ± 0.77%, respectively. The mean dose differences in target dose calculation between ArcherQA and TPS: intracranial in the gross tumor volume (GTV) regions were 0.34% ± 2.21%, lung tumor GTV were -2.47% ± 2.46%, and abdominal tumor GTV were 0.80% ± 2.61%, respectively. Among them, the abdominal GTV region showed the highest correlation between ArcherQA and measured results ( r=0.78). The average two-dimensional γ pass rates (2 mm/2%, threshold=10%) measured using phantom films were 95.92% ± 2.35% for intracranial, 95.70% ± 2.74% for lung, and 96.74% ± 3.41% for abdominal tumors plans, respectively. The three-dimensional ArcherQA results showed comparable γ pass rates (1 mm/2%, threshold=10%) for lung and abdominal GTV and PTV regions, with similar medians and data dispersion to film measurements. Conclusions:The ArcherQA system enables rapid and efficient independent dose verification of CK SRT plans without the need for additional hardware. The verification results show good correlation with phantom measurements, supporting its potential as an auxiliary quality assurance tool in clinical CK SRT implementation.
6.Challenge of shielding design for FLASH radiotherapy
Hongkai WANG ; Minghui LI ; Chuanmeng NIU ; Yixin SONG ; Dongsheng HAN ; Kuo MEN ; Jianrong DAI
Chinese Journal of Radiological Medicine and Protection 2023;43(8):653-656
Compared with conventional radiotherapy, FLASH radiotherapy has advantages in protecting normal tissues, while the dose rate is increased by more than 100 times. If the shielding design of the treatment room is carried out according to the existing standard, the thickness and cost of the shielding wall will be significantly increased, or even hardly to meet the requirement of the standards, resultsing in the failure of the application of FLASH radiotherapy. By investigating the domestic and foreign standards and literature, this paper analyzes the challenges brought by FLASH radiotherapy technology to the shielding design of radiotherapy treatment room in China. Dose rate control standards adopted by different countries in the shielding design are emphatically compared as well. In several countries, the average dose rate under the actual treatment conditions was considered in the shielding design. In China, the method of instantaneous dose rate taking acount of occupancy factor is adopted. However, if FLASH radiotherapy technology is applied, the requirement of instantaneous dose rate will be difficult to meet. In order to improve the high dose rate radiotherapy technology such as FLASH radiotherapy, the revision of the existing standards is advised if the authorized limits are not changed. To use the average dose rate limit within a certain period of time for control, or to raise the control standard in the case of flash radiotherapy, are also avaliable.
7.Nanopolyphenol rejuvenates microglial surveillance of multiple misfolded proteins through metabolic reprogramming.
Dayuan WANG ; Xiao GU ; Xinyi MA ; Jun CHEN ; Qizhi ZHANG ; Zhihua YU ; Juan LI ; Meng HU ; Xiaofang TAN ; Yuyun TANG ; Jianrong XU ; Minjun XU ; Qingxiang SONG ; Huahua SONG ; Gan JIANG ; Zaiming TANG ; Xiaoling GAO ; Hongzhuan CHEN
Acta Pharmaceutica Sinica B 2023;13(2):834-851
Microglial surveillance plays an essential role in clearing misfolded proteins such as amyloid-beta, tau, and α-synuclein aggregates in neurodegenerative diseases. However, due to the complex structure and ambiguous pathogenic species of the misfolded proteins, a universal approach to remove the misfolded proteins remains unavailable. Here, we found that a polyphenol, α-mangostin, reprogrammed metabolism in the disease-associated microglia through shifting glycolysis to oxidative phosphorylation, which holistically rejuvenated microglial surveillance capacity to enhance microglial phagocytosis and autophagy-mediated degradation of multiple misfolded proteins. Nanoformulation of α-mangostin efficiently delivered α-mangostin to microglia, relieved the reactive status and rejuvenated the misfolded-proteins clearance capacity of microglia, which thus impressively relieved the neuropathological changes in both Alzheimer's disease and Parkinson's disease model mice. These findings provide direct evidences for the concept of rejuvenating microglial surveillance of multiple misfolded proteins through metabolic reprogramming, and demonstrate nanoformulated α-mangostin as a potential and universal therapy against neurodegenerative diseases.
8.Correlation between physical fitness and reading ability among school aged children
XIAO Pei, ZHOU Xinhong, ZHOU Jianrong,JIANG Qi,FENG Yanan,WU Xiaoqian,XIANG Zhen,ZOU Li,SONG Ranran
Chinese Journal of School Health 2022;43(5):784-787
Objective:
To determine the association between physical health fitness with Chinese reading ability of schoolaged children, so as to provide evidence for improving children s reading ability.
Methods:
A questionnaire survey was conducted among 1 923 school aged children in grades 2-6 in a primary school in Wuhan, Hubei Province, China. The questionnaire included basic demographic information and Dyslexia Checklist for Chinese Children and the Pupil Rating Scale Revised Screening. At the same time, participants underwent physical fitness tests which included an assessment of height, weight, and lung capacity, as well as a 50 meter run, sit forward bend, one minute skipping rope task, sit ups, and a 50 × 8 round trip.
Results:
A total of 59 children were identified with dyslexia. Normal children achieved higher scores than children with dyslexia in the total physical health score, as well as the one minute skipping rope score, one minute sit up score, and sitting forward score ( P <0.05). Multiple linear regression analyses showed that the reading ability of girls was higher than that of boys ( β =-3.04, P <0.01), and the children who regularly participated in more intense physical activity and who had higher fitness scores had a higher reading ability ( β =-1.68, -0.08, P <0.01). Children s reading ability increased significantly with parental educational level( P <0.05).
Conclusion
Gender, parents education level, physical exercise intensity, and children s physical fitness were identified as influencing factors of school age children s reading ability. A positive correlation was found between children s physical health level and reading ability.
9.Targeting a cryptic allosteric site of SIRT6 with small-molecule inhibitors that inhibit the migration of pancreatic cancer cells.
Qiufen ZHANG ; Yingyi CHEN ; Duan NI ; Zhimin HUANG ; Jiacheng WEI ; Li FENG ; Jun-Cheng SU ; Yingqing WEI ; Shaobo NING ; Xiuyan YANG ; Mingzhu ZHAO ; Yuran QIU ; Kun SONG ; Zhengtian YU ; Jianrong XU ; Xinyi LI ; Houwen LIN ; Shaoyong LU ; Jian ZHANG
Acta Pharmaceutica Sinica B 2022;12(2):876-889
SIRT6 belongs to the conserved NAD+-dependent deacetylase superfamily and mediates multiple biological and pathological processes. Targeting SIRT6 by allosteric modulators represents a novel direction for therapeutics, which can overcome the selectivity problem caused by the structural similarity of orthosteric sites among deacetylases. Here, developing a reversed allosteric strategy AlloReverse, we identified a cryptic allosteric site, Pocket Z, which was only induced by the bi-directional allosteric signal triggered upon orthosteric binding of NAD+. Based on Pocket Z, we discovered an SIRT6 allosteric inhibitor named JYQ-42. JYQ-42 selectively targets SIRT6 among other histone deacetylases and effectively inhibits SIRT6 deacetylation, with an IC50 of 2.33 μmol/L. JYQ-42 significantly suppresses SIRT6-mediated cancer cell migration and pro-inflammatory cytokine production. JYQ-42, to our knowledge, is the most potent and selective allosteric SIRT6 inhibitor. This study provides a novel strategy for allosteric drug design and will help in the challenging development of therapeutic agents that can selectively bind SIRT6.
10.Application of visual feedback coaching bar in deep inspiration breath holding during left breast cancer radiotherapy
Tantan LI ; Jianghu ZHANG ; Shulian WANG ; Yongwen SONG ; Yu TANG ; Fengyu LU ; Wei ZHANG ; Zengzhou WANG ; Shirui QIN ; Ji ZHU ; Fukui HUAN ; Jianrong DAI
Chinese Journal of Radiation Oncology 2021;30(3):258-261
Objective:To evaluate the application of visual feedback coaching method, which is embedded in an optical surface monitoring system, in deep inspiration breath holding during the radiotherapy in left breast cancer patients after breast-conserving surgery.Methods:Thirty patients with left breast cancer, who were scheduled to receive the whole breast radiotherapy after breast-conserving surgery, met the requirements of deep inspiration breath holding after respiratory coaching with the visual feedback coaching module in the optical surface monitoring system. Active breathing control equipment was used to control breath-holding state and CT simulation was performed. During treatment, optical surface monitoring system was used to guide radiotherapy. All patients were randomly divided into two groups. In group A ( n=15), visual feedback respiratory training method was utilized and not employed in group B ( n=15). In group A, the visual feedback coaching bar of the optical surface monitoring system was implemented, while audio interactive method was employed to guide patients to hold their breath. Real-time data of optical body surface monitoring were used to compare the interfraction reproducibility and intrafraction stability of breath holding fraction between two groups. Besides, the number of breath holding and treatment time per fraction were also compared. GraphPad prism 6.0 software was used for data processing and mapping, and SPSS 21.0 software was used for analyzing mean value and normality testing. Results:Compared with the control group, the reproducibility in the experiment group was reduced from 1.5 mm to 0.7 mm, the stability was reduced from 1.1 mm to 0.8 mm, the mean number of breath holding required per fraction was decreased from 4.6 to 2.4, the mean beam-on time per fraction from 336 s to 235 s, and the treatment time per fraction was shortened from 847 s to 602 s (all P<0.05), respectively. Conclusions:The application of visual feedback coaching method can improve the reproducibility and stability of breath holding during radiotherapy for left breast cancer, and it can also effectively reduce the number of breath holding and shorten the treatment time per fraction.


Result Analysis
Print
Save
E-mail