1.Effects of T2-FLAIR sequence under different imaging conditions on the appearance of ivy sign in patients with moyamoya disease
Wenxue TIAN ; Shen GAO ; Xiangyun RONG ; Zhaoxue ZHANG ; Jianming CAI ; Fugeng SHENG ; Hongtao ZHANG
Military Medical Sciences 2025;49(4):303-306
Objective To investigate the effect of T2-fluid attenuated inversion recovery(T2-FLAIR)sequence on the appearance of ivy sign in patients with moyamoya disease under different imaging conditions.Methods Coronal T2-FLAIR scans were performed in 51 consecutive adult patients with moyamoya disease who had not undergone surgery and had their first visit to this hospital between March and July of 2024.According to the scanning conditions,the patients were divided into 19 and 14 of the echo train length in two groups,and 103,144,and 195 ms of the time of echo(TE)in three groups,respectively.The left and right cerebral hemispheres and whole brains were scored according to the cerebral vascular anatomy,and scores of the ivy sign of left and right cerebral hemispheres and whole brain were compared.Results There was no statistical significance in the ivy sign scores of right and left cerebral hemispheres and whole brain between the two groups with 19 and 14 of the echo train length(P>0.05).Comparison of ivy sign scores in right and left cerebral hemispheres and whole brain was statistically significant among the three groups of TE at 144,103 and 195 ms(P<0.05).Conclusion The best appearance of ivy sign in patients with moyamoya disease is seen under the condition of TE at 195 ms,so appropriately extending the TE time is helpful for ivy sign display.
2.Tubeless subxiphoid uniportal video-assisted thoracoscopic surgery with percutaneous suspension technique via balance-shaped sternal elevation device in anterior mediastinal masses
Junmin ZHU ; Junjie WANG ; Jianming YUE ; Yixin SUN ; Yichen LIU ; Lei WANG ; Lin LIN ; Jie LI ; Jinlan ZHAO ; Xuehua TU ; Ningying DING ; Jianrong HU ; Chunmei HE ; Leilei TIAN ; Hongtao TANG ; Jiasheng ZHAO ; Cheng CHEN ; Yongxiang SONG ; Yunwei TIAN ; Yong XIAO ; Kaidi LI ; Lin MA ; Yun WANG ; Longqi CHEN ; Dong TIAN
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(11):1603-1609
Objective To assess the clinical value of a novel surgical technique—Tubeless subxiphoid uniportal video-assisted thoracoscopic surgery with percutaneous suspension technique via balance-shaped sternal elevation device in the resection of anterior mediastinal masses. Methods Patients who underwent tubeless subxiphoid uniportal video-assisted thoracoscopic surgery via balance-shaped sternal elevation device in anterior mediastinal masses process at the Department of Thoracic Surgery, West China Hospital, Sichuan University from March to April 2025 were included, and their clinical data were analyzed. Results A total of 4 patients were included, with 2 males and 2 females, aged 58-75 years. The diameter of the tumor was 2.5-3.0 cm. The operation time was 60.0-150.0 min, intraoperative blood loss was 5-10 mL, pain score on the 3rd day after surgery was 0 points, and postoperative hospital stay was 2-3 days. All patients achieved complete resection of the masses and thymus without perioperative complications. Conclusion The tubeless subxiphoid uniportal video-assisted thoracoscopic surgery with percutaneous suspension technique via balance-shaped sternal elevation device technique optimizes surgical visualization and instrument maneuverability while avoiding complications related to conventional anesthesia and tubing, thereby markedly enhancing the minimally invasive profile of anterior mediastinal masses resections. In addition to maintaining procedural safety, this approach effectively reduces postoperative pain and accelerates patient recovery, highlighting its potential for widespread clinical adoption.
3.Expert consensus on clinical application of 177Lu-prostate specific membrane antigen radio-ligand therapy in prostate cancer
Guobing LIU ; Weihai ZHUO ; Yushen GU ; Zhi YANG ; Yue CHEN ; Wei FAN ; Jianming GUO ; Jian TAN ; Xiaohua ZHU ; Li HUO ; Xiaoli LAN ; Biao LI ; Weibing MIAO ; Shaoli SONG ; Hao XU ; Rong TIAN ; Quanyong LUO ; Feng WANG ; Xuemei WANG ; Aimin YANG ; Dong DAI ; Zhiyong DENG ; Jinhua ZHAO ; Xiaoliang CHEN ; Yan FAN ; Zairong GAO ; Xingmin HAN ; Ningyi JIANG ; Anren KUANG ; Yansong LIN ; Fugeng LIU ; Cen LOU ; Xinhui SU ; Lijun TANG ; Hui WANG ; Xinlu WANG ; Fuzhou YANG ; Hui YANG ; Xinming ZHAO ; Bo YANG ; Xiaodong HUANG ; Jiliang CHEN ; Sijin LI ; Jing WANG ; Yaming LI ; Hongcheng SHI
Chinese Journal of Clinical Medicine 2024;31(5):844-850,封3
177Lu-prostate specific membrane antigen(PSMA)radio-ligand therapy has been approved abroad for advanced prostate cancer and has been in several clinical trials in China.Based on domestic clinical practice and experimental data and referred to international experience and viewpoints,the expert group forms a consensus on the clinical application of 177Lu-PSMA radio-ligand therapy in prostate cancer to guide clinical practice.
5.Clinical application of bedside X-ray photography assistor in neonates
Shuang TIAN ; Xiaole HAN ; Xiangchuang KONG ; Ziqiao LEI ; Jianming YU ; Cuiling LI
Chinese Journal of Radiological Medicine and Protection 2023;43(4):297-300
Objective:To assess the clinical application of bedside X-ray photography assistor (Patent No. 202 023 219 898.1) in neonatal bedside photography.Methods:From April 2021 to February 2022, a total of 180 pediatric patients were selected who underwent bedside chest X-ray photography in neonatal intensive care unit (NICU) of Union Hospital Affiliated to Tongji Medical College of Huazhong University of Science and Technology. These patients were divided into contrpol group, consisting of 48 males and 42 females aged at (3.3 ± 2.0) d (0-10 d), and experimental group, including 50 males and 40 females aged (3.1±2.2) d (0-12 d). For chest photography, routine workflow was followed in the control group while in experimental group bedside photography protection and body position fixing device was used. The examination time, reshoot rate and image quality were compared between the two groups.Results:The diagnostic physician score and patient comfort score in the experimental group were higher than those in the control group, with statistically significant differences ( t = 3.98, 3.82, P < 0.001). The success rate in the experimental group was higher than that in the control group, with statistically significant difference ( χ2= 7.84, P < 0.05). The average time of examination in the experimental group was not significantly different from in the control group ( P>0.05 ). Conclusions:The application of bedside X-ray photography assistor in neonatal bedside photography can significantly improve the success rate and image quality and reduce the radiation dose to pediatric patients without significantly increased examination time, which is worthy of clinical application and promotion.
6.Potential unreliability of ALK variant allele frequency in the efficacy prediction of targeted therapy in NSCLC.
Wei RAO ; Yutao LIU ; Yan LI ; Lei GUO ; Tian QIU ; Lin DONG ; Jianming YING ; Weihua LI
Frontiers of Medicine 2023;17(3):493-502
Anaplastic lymphoma kinase (ALK) is the most common fusion gene involved in non-small cell lung cancer (NSCLC), and remarkable response has been achieved with the use of ALK tyrosine kinase inhibitors (ALK-TKIs). However, the clinical efficacy is highly variable. Pre-existing intratumoral heterogeneity (ITH) has been proven to contribute to the poor treatment response and the resistance to targeted therapies. In this work, we investigated whether the variant allele frequencies (VAFs) of ALK fusions can help assess ITH and predict targeted therapy efficacy. Through the application of next-generation sequencing (NGS), 7.2% (326/4548) of patients were detected to be ALK positive. On the basis of the adjusted VAF (adjVAF, VAF normalization for tumor purity) of four different threshold values (adjVAF < 50%, 40%, 30%, or 20%), the association of ALK subclonality with crizotinib efficacy was assessed. Nonetheless, no statistical association was observed between median progression-free survival (PFS) and ALK subclonality assessed by adjVAF, and a poor correlation of adjVAF with PFS was found among the 85 patients who received first-line crizotinib. Results suggest that the ALK VAF determined by hybrid capture-based NGS is probably unreliable for ITH assessment and targeted therapy efficacy prediction in NSCLC.
Humans
;
Carcinoma, Non-Small-Cell Lung/pathology*
;
Anaplastic Lymphoma Kinase/therapeutic use*
;
Crizotinib/therapeutic use*
;
Lung Neoplasms/pathology*
;
Protein Kinase Inhibitors/pharmacology*
;
Gene Frequency
7.Clinical reliability of radiation protection of a neonatal bedside X-ray photography device
Xiaole HAN ; Cuiling LI ; Shuang TIAN ; Tian LIAO ; Ziqiao LEI ; Jianming YU ; Xiangchuang KONG
Chinese Journal of Radiological Medicine and Protection 2022;42(7):549-553
Objective:To analyze the clinical reliability of neonatal bedside photography protection and body position fixing device during neonatal bedside X-ray photography.Methods:A mobile X-ray diagnostic machine was used to project the phantom of children. The samples were divided into group A with conventional bedside photography mode, and group B using neonatal bedside X-ray photography protection device. X-ray diagnostic level dosimeters were placed at the projection and radiation sensitive sites, respectively. The three parts of the chest, pelvis and skull were used as the projection center, and the radiation dose to the projection site and the radiation sensitive site were collected and recorded, and the statistical analysis was carried out.Results:When the chest was taken as the center of the projection, the radiation doses to the lens of the eye, thyroid and gonad in the body model group B of children were 94.4%, 96.9% and 96.7% lower than those in the non-injected part of group A, respectively ( t=-152.55, -445.16, -129.07, P<0.05). When the pelvis was taken as the projection center, the radiation doses to the lens, thyroid and thymus in the body model group B were 85.5%, 87.1% and 94.9% lower than those in the non-projection part of group A, respectively ( t=-50.68, -194.18, -535.94, P<0.05). When the head was taken as the projection center, the radiation doses to thyroid, thymus and gonad in the body model group B were 99.3 %, 97.4 % and 94.3 % lower than those in the non-projection position of group A, respectively ( t=-1 859.97, -542.08, -66.26, P< 0.05). Conclusions:The use of neonatal bedside photography protection and position fixing device during neonatal bedside X-ray photography can significantly reduce the radiation dose to children in non-projected areas under the premise of ensuring image quality. At the same time, it can fix and protect the children, improve the success rate of examination, being worthy of clinical promotion.
8.Autofluorescence combined with spectral domain optical coherence tomography for diagnosis and follow-up of acute Vogt-Koyanagi-Harada disease.
Shuwei TIAN ; Jing YAO ; Jianming WANG ; Jie ZHANG ; Aiyi ZHOU
Journal of Southern Medical University 2021;41(1):135-140
OBJECTIVE:
To evaluate the value of fundus autofluorescence (FAF) imaging combined with spectral domain optical coherence tomography (SD-OCT) in diagnosis, prognostic assessment and follow-up observation of acute Vogt-KoyanagiHarada (VKH) disease.
METHODS:
Clinical data were collected from 12 patients (23 eyes) with acute VKH disease treated in our hospital from May, 2018 to November, 2019, including detailed medical history, best corrected visual acuity (BCVA), and results of slit lamp biomicroscopy, fundus photography, SD-OCT, fundus fluorescein angiography (FFA) and FAF imaging.SDOCT and FAF imaging were repeated after a course of treatment and in follow-up examination, and the results were compared with those at the time of admission.
RESULTS:
VKH disease involved both eyes in 11 patients (91.7%).Fundus photography showed optic disc edema in 16 eyes (69.6%), and multiple retinal neuroepithelial detachment was detected by SD-OCT in all the involved eyes (100%).IN all the eyes, FFA revealed small and dense fluorescein leakage in the early stage and fluorescein accumulation in advanced stages of VHK disease to form multiple dye pooling in the areas of serous detachment.Hyperauto fluorescence was a common finding in FAF imaging (100%), and the area involved was consistent with that of fluorescein accumulation shown by FAF imaging.Ten eyes (43.5%) showed patches of relative hypoautofluorescence in the hyperauto fl uorescence areas, and granular hyperauto fl uorescence was found in the lesions in 4 eyes (17.4%).During the remission period of VKH disease, FAF imaging showed normal finding in 8 eyes (34.8%) and reduced areas (by 55.2%) and intensity (by 46.5%) of hyperautofluorescence in 9 eyes (39.1%).In 6 eyes (26.1%), only a few hyperautofluorescent spots scattered in the macula were observed.SD-OCT demonstrated significantly reduced (by 69.5% on average) or even disappearance of subretinal fluid in the eyes.The fluorescence intensity in FAF imaging showed a significant positive correlation with the volume of subretinal fluid detected by SD-OCT (
CONCLUSIONS
The combination of fluorescein angiography, FAF imaging and SD-OCT can significantly improve the diagnostic accuracy of VKH disease.FAF imaging combined with SD-OCT provides an effective and noninvasive modality for evaluation of remission and monitoring the changes in VKH disease.
Acute Disease
;
Fluorescein Angiography
;
Follow-Up Studies
;
Humans
;
Retinal Detachment/diagnostic imaging*
;
Tomography, Optical Coherence
;
Uveomeningoencephalitic Syndrome/diagnostic imaging*
9.Size-specific dose estimations in children′s head CT scans
Tian LIAO ; Zilong YUAN ; Yantao NIU ; Qing FU ; Xiaoming LIU ; Ming YANG ; Hongying WU ; Ziqiao LEI ; Jianming YU ; Xiangchuang KONG
Chinese Journal of Radiological Medicine and Protection 2021;41(7):524-528
Objective:To investigate the value of the size-specific dose estimate (SSDE) on dose estimations of children's head CT scans.Methods:A retrospective study was conducted on plain head CT scans of 252 patients with the 64-row detector CT device of Discovery 750HD in the Union Hospital, Tongji Medical College, Huazhong University of Science and Technology from January to September in 2019. The volume CT dose index (CTDI vol)values were recorded. The head circumference (HC), area, and CT value were measured using a self-developed computer program, and the water equivalent diameter (WED), size-specific conversion factors ( f293 and f220), and absorbed dose (SSDE 293 and SSDE 220) were calculated according to the AAPM reports 293 and 220.The patients were divided into three groups by the quartering meth odaccording to their HC(<47.8 cm, 47.8-52.7 cm, >52.7 cm)and four groups based on their ages(0-2, 3-6, 7-10 and 11-14 years old). The difference between parameters ( f220 and f293, SSDE 220 and SSDE 293、SSDE 293 and CTDI vol) were compared for different groups, and the correlation of HC with f293 and SSDE 293 was analyzed. Results:There was an overestimation of f220 by 11.11% ( t=252.61, P<0.05) compared with f293. SSDE 220 was overestimated by 10.31% ( t=228.21, P<0.05) compared with SSDE 293, and SSDE 293 was underestimated by 9.60% ( t=-31.34, P<0.05)compared with CTDI vol. For the three HC groups, SSDE 220 was overestimated by 8.54%, 10.37%, and 11.57% ( t=73.73, 438.58, 275.52, P<0.05)compared with SSDE 293, and SSDE 293 was underestimated by 1.30%, 9.79%, and 14.61% ( t=-1.91, -60.95, -47.64, P<0.05)compared with CTDI vol. For the four age groups SSDE 220 was overestimated by 8.45%, 10.00%, 10.57%, and 11.36% ( t=63.58, 232.29, 247.84, 302.95, P< 0.05)compared with SSDE 293, and SSDE 293 was underestimated by 1.49%, 8.27%, 10.63%, and 13.78% ( t=-1.83, -28.27, -37.30, -49.80, P< 0.05)compared with CTDI vol. Furthermore, HC was highly correlated with f293 and SSDE 293 ( r2=0.88 and 0.76, respectively, P< 0.05). Conclusions:The radiation dose in children′s head CT scanning can be more accurately estimated according to the AAPM Report 293, while it can be overestimated by CTDI vol. Meanwhile, the CT radiation dose can be patently overestimated with the AAPM Report 220 compared with Report 293.HC is closely correlated with f293 and SSDE 293 and it can be used to estimatee more accurately for SSDE and the radiation dose received by children during head CT scanning.
10. A multicenter retrospective study on clinical value of lymph node dissection in the radical resection of intrahepatic cholangiocarcinoma
Lei WANG ; Ziguo LIN ; Tian YANG ; Jianying LOU ; Shuguo ZHENG ; Xinyu BI ; Jianming WANG ; Wei GUO ; Fuyu LI ; Jian WANG ; Yamin ZHENG ; Jingdong LI ; Shi CHENG ; Yongyi ZENG ; Jingfeng LIU
Chinese Journal of Digestive Surgery 2020;19(1):72-80
Objective:
To investigate the clinical value of lymph node dissection (LND) in the radical resection of intrahepatic cholangiocarcinoma (ICC).
Methods:
The propensity score matching and retrospective cohort study was conducted. The clinicopathological data of 448 patients with ICC who were admitted to 12 medical centers from December 2011 to December 2017 were collected, including 279 in the Eastern Hepatobiliary Surgery Hospital of Navy Medical University, 32 in the Mengchao Hepatobiliary Hospital of Fujian Medical University, 21 in the First Hospital Affiliated to Army Medical University, 20 in the Cancer Hospital Chinese Academy of Medical Science and Peking Union Medical College, 19 in the West China Hospital of Sichuan University, 18 in the Second Hospital Affiliated to Zhejiang University School of Medicine, 18 in the Renji Hospital Affiliated to Shanghai Jiaotong University School of Medicine, 16 in the Beijing Friendship Hospital Affiliated to Capital Medical University, 10 in the Xuanwu Hospital Affiliated to Capital Medical University, 7 in the Tongji Hospital Affiliated to Tongji Medical College of Huazhong University of Science and Technology, 5 in the Beijing Tiantan Hospital Affiliated to Capital Medical University, and 3 in the Affiliated Hospital of North Sichuan Medical College. There were 281 males and 167 females, aged from 22 to 80 years, with a median age of 57 years. Of the 448 patients, 143 with routinely intraoperative LND were divided into LND group and 305 without routinely intraoperative LND were divided into control group, respectively. Observation indicators: (1) the propensity score matching conditions and comparison of general data between the two groups after matching; (2) intraoperative and postoperative situations; (3) follow-up; (4) survival analysis. Patients were followed up by outpatient examination, telephone interview and email to detect survival of patients and tumor recurrence up to October 31, 2018 or death. Follow-up was conducted once every 3 months within postoperative 1-2 years, once every 6 months within postoperative 2-5 years, and once a year after 5 years. The propensity score matching was realized using the nearest neighbor method with 1∶1 ratio. Measurement data with normal distribution were represented as

Result Analysis
Print
Save
E-mail