1.Analysis of the Influence of Different Scanning Conditions of Medical Linear Accelerator CBCT on Image Quality.
Li LIU ; Chengwei YE ; Jianjun YUAN ; Yingui LUO ; Zhiyao LUO ; Wei ZENG ; Ling LI ; Huan LIU ; Yan LIU
Chinese Journal of Medical Instrumentation 2025;49(2):176-180
OBJECTIVE:
To investigate the influence of different scanning conditions on the image quality of medical electron accelerator cone-beam computed tomography (CBCT) and provide a reference for the selection of scanning conditions for different body parts. Methods Set different scanning conditions, the Catphan 503 phantom was scanned using CBCT parameters to analyze the influence of spatial resolution, noise, uniformity, spatial geometric accuracy, and low-contrast resolution on the image quality of CBCT.
RESULTS:
For the head, chest, and abdomen, with the increase in scanning parameter values, the noise value decreased by 47.4%, 26.1%, and 51.3% respectively, and the uniformity values decreased by 30.2%, 26.6%, and 47.9% respectively. The low-contrast resolution values decreased by 50.6%, 34.2%, and 12.0%. The influence of different scanning conditions on spatial geometric accuracy and spatial resolution is not significant.
CONCLUSION
Different scanning parameters have a certain influence on the image quality of medical electron accelerator CBCT. Lower scanning parameters can be selected based on individual patients to reduce the additional radiation dose, providing a reference for the safe application of CBCT image guidance in radiotherapy.
Cone-Beam Computed Tomography/instrumentation*
;
Phantoms, Imaging
;
Particle Accelerators
2.Successful in situ 5-aminolevulinic acid photodynamic therapy in a 53-year-old female with cutaneous squamous cell carcinoma.
Limin LUO ; Xiaoling JIANG ; Jianjun QIAO ; Hong FANG ; Jun LI
Journal of Zhejiang University. Science. B 2025;26(9):915-922
Basal cell carcinoma (BCC) and cutaneous squamous cell carcinoma (cSCC), as certain forms of non-melanoma skin cancer (NMSC) or keratinocyte carcinoma, are the most common forms of malignant neoplasms worldwide (Sharp et al., 2024). BCC and cSCC have been identified as two major components of NMSC, comprising one-third of all malignancies (Burton et al., 2016). Generally speaking, patients with NMSC tend to have relatively favorable survival outcomes, while different histopathological subtypes of NMSC exhibit distinct biological behaviors (Stătescu et al., 2023). Keratinocyte carcinoma, although not considered as deadly as melanoma, tends to metastasize if left untreated (Civantos et al., 2023; Nanz et al., 2024). cSCC can evolve locally, then aggressively metastasize, invade, and even lead to fatal consequences in a subset of patients (Winge et al., 2023). A solid, pigmented, smooth plaque or a hyperkeratotic papule with or without central ulceration and hemorrhage appears to be characteristic of cSCC (Thompson et al., 2016; Zhou et al., 2023). Of note, a rare type of intraepidermal cSCC in situ often appears as a velvety, demarcated, slightly raised erythematous plaque on the genitalia of men (Yamaguchi et al., 2016). Accounting for approximately 16.0% of scalp tumors and with a rising incidence, cSCC is now the second most common NMSC in humans (Verdaguer-Faja et al., 2024). According to the latest statistics, up to 2%‒5% of cSCCs in situ may gradually progress into invasive cSCCs in the final step (Rentroia-Pacheco et al., 2023). Several risk factors for the carcinogenesis and development of cSCC have been identified, including age, accumulative exposure to ultraviolet light radiation A and B, human papillomavirus infection, arsenic ingestion, chronic scarring, xeroderma pigmentosa, a relevant history of ionizing radiation, androgenetic alopecia in males, and immunosuppression therapy (Martinez and Otley, 2001; Welsch et al., 2012; Mortaja and Demehri, 2023).
Humans
;
Aminolevulinic Acid/therapeutic use*
;
Skin Neoplasms/pathology*
;
Photochemotherapy/methods*
;
Female
;
Carcinoma, Squamous Cell/pathology*
;
Middle Aged
;
Photosensitizing Agents/therapeutic use*
;
Carcinoma, Basal Cell/drug therapy*
3.Chinese expert consensus on the evaluation of allergen-specific immunotherapy outcomes(Wuhan, 2025).
Yuqin DENG ; Xi LUO ; Zhuofu LIU ; Shuguang SUN ; Jing YE ; Tiansheng WANG ; Jianjun CHEN ; Meiping LU ; Yin YAO ; Ying WANG ; Wei ZHOU ; Bei LIU ; Qingxiang ZENG ; Yuanteng XU ; Qintai YANG ; Yucheng YANG ; Feng LIU ; Chengli XU ; Yanan SUN ; Haiyu HONG ; Haibo YE ; Liqiang ZHANG ; Fenghong CHEN ; Huabin LI ; Hongtian WANG ; Yuncheng LI ; Wenlong LIU ; Yu XU ; Hongfei LOU
Journal of Clinical Otorhinolaryngology Head and Neck Surgery 2025;39(11):1075-1085
Allergen-specific immunotherapy(AIT) remains the only therapeutic approach with the potential to modify the natural course of allergic rhinitis(AR). Nevertheless, considerable inter-individual variability exists in patients'responses to AIT. To facilitate more reliable assessment of treatment efficacy, the China Rhinopathy Research Cooperation Group(CRRCG) convened young and middle-aged nasal experts in China to formulate the present consensus. The recommended subjective outcome measures for AIT comprise symptom scores, medication scores, combined symptom and medication scores, quality-of-life assessments, evaluation of disease control, and assessment of comorbidities. Objective indicators may supplement these measures. Currently available objective approaches include skin prick testing, nasal provocation testing, and allergen exposure chambers. However, these methods remain constrained by practical limitations and are not yet appropriate for routine implementation in clinical efficacy evaluation. In addition, several biomarkers, including sIgE and the sIgE/tIgE ratio, sIgG4, serum IgE-blocking activity, IgA, cytokines and chemokines, as well as immune cell surface molecules and their functional activity, have been shown to have associations with AIT outcomes. While these biomarkers may complement subjective assessments, they are subject to significant limitations. Consequently, large-scale multicenter trials and real-world evidence are required to strengthen the evidence base. The present consensus underscores the necessity of integrating patients'subjective experiences with objective testing throughout the treatment process, thereby providing a more comprehensive and accurate framework for efficacy evaluation. Looking forward, future investigations should prioritize the incorporation of multi-omics data and artificial intelligence methodologies, which hold promise for overcoming current limitations in assessment strategies and for advancing both the standardization and personalization of AIT.
Humans
;
Allergens/immunology*
;
China
;
Consensus
;
Desensitization, Immunologic
;
Immunoglobulin E
;
Quality of Life
;
Rhinitis, Allergic/therapy*
;
Treatment Outcome
;
East Asian People
4.Comparative study of different image-guided systems in positioning error and placement outside the target area of radiotherapy for cervical cancer
Li LIU ; Chengwei YE ; Jianjun YUAN ; Yingui LUO ; Zhiyao LUO ; Wei ZENG ; Ling LI ; Huan LIU ; Yan LIU ; Miao HE
China Medical Equipment 2025;22(4):18-22
Objective:To compare and analyze the differences in positioning errors and placement outside the target area between two different image-guided systems(Halcyon and Synergy)in radiotherapy for cervical cancer.Methods:The data of 40 patients with cervical cancer who received treatment in Dezhou People's Hospital from March 2023 to June 2023 were retrospectively selected.Each patient was treated respectively with Halcyon linear accelerator and Synergy linear accelerator,with 20 cases for each treatment method.All patients underwent cone beam computed tomography(CBCT)at kV level to conduct image scanning before radiotherapy,and the obtained CBCT images were matched with the positioned CT images by online.The registration results of left and right(x),head and foot(y)and front and back(z)of three translation direction,and pitch(Rx),rotation(Ry)and deflection(Rz)directions of rotation direction were respectively obtained.The margin of planning target volume(MPTV)was calculated according to positioning expansion formula.The differences of positioning errors and target area expansion between Halcyon and Synergy image-guided systems were compared and analyzed.Results:Halcyon and Synergy image-guided systems obtained respectively 479 and 447 sets of CBCT images.The translational errors of Halcyon image-guided system on x,y,and z directions were respectively(-0.03±0.21),(0.12±0.63)and(0.02±0.15)cm,and the rotational errors of that on Rx,Ry and Rz directions were respectively(0.38±1.26)°,(-0.40±1.02)°,and(0.07±1.07)°.The translational errors of Synergy image-guided system were respectively(-0.07±0.18),(0.08±0.49)and(0.11±0.22)cm on the three directions,and the rotational errors of that were respectively(0.28±1.29)°,(-0.29±1.29)° and(-0.16±1.20)°.The translational error values on the y direction of both image-guided system were larger than that on x and z directions,and the absolute values of the range of translational errors of them were basically within 5 mm.There were no statistically significant difference in the positioning errors of rotation on Rx and Ry directions between Halcyon and Synergy image-guided systems(P>0.05),while there was a statistically significant difference in the positioning error of rotation on Rz direction between them(t=-3.06,P<0.05).The MPTV values of Halcyon image-guided system on x,y and z directions were respectively 0.4,1.4 and 0.3 cm,and those of Synergy image-guided system were respectively 0.4,0.9 and 0.5 cm.The expansion boundary of target area of Halcyon image-guided system on the y direction was larger than that of Synergy image-guided system,and that on other directions were all less or equal to 0.5 cm.Conclusion:The MPTV values of Halcyon and Synergy image-guided systems can meet clinical requirements in radiotherapy.The positioning errors and the tube current of the scan of Halcyon image-guided system were larger than those of Synergy image-guided system,but the scanning time and treatment time of that were significantly lower than those of Synergy image-guided system.Different treatment systems can be selected individually for patients according to their different conditions.
5.Establishment and preliminary study of four patient-derived primary breast cancer cell lines
Yubei LUO ; Jianjun HUANG ; Wenxiu YANG ; Junhong ZHANG ; Jing LI ; Chunhua-Robert ZHAO ; Xiaowei DOU
Basic & Clinical Medicine 2025;45(2):183-188
Objective To establish primary breast cancer cell lines from patient tissues and offer a new cancer cell model for basic research.Methods Breast cancer biopsy tissues were digested with typeⅡcollagenase and cultured in BCMI medium.When the cells proliferated rapidly,the medium was switched to DMEM.STR genotyping was per-formed to identify specific genetic markers of the four primary breast cancer cell lines.Colony expansion assays and sphere formation assays were conducted to analyze its tumorigenicity.Real-time PCR and Western blot experiments were used to analyze the expression of the epithelial-mesenchymal transition(EMT)molecule markers.Migration and invasion assays were performed to assess the metastatic potential of the primary breast cancer cells.Results We es?tablished four primary breast cancer cell lines:BC25#,BC51#,BC56#,and BC57#.These cell lines were cultured in DMEM medium,passaged multiple times and tagged with details about their clinical past.STR genotyping identified specific genetic markers for each of the four primary breast cancer cell lines.Clonogenic and sphere formation assays revealed that the four lines have a stronger tumor?forming capability compared to the classic breast cancer cell line T?47D.Real?time PCR and Western blot experiments showed that,compared to T?47D,the four primary breast cancer cell lines have decreased E?cadherin expression and increased vimentin expression.Migration and invasion assays indicated that BC25#had a higher metastatic potential than the traditional breast cancer cell line T?47D.Conclusions Four primary breast cancer cell lines,BC25#,BC51#,BC56#and BC57#are successfully estab?lished,which may act as new cancer cell model for laboratory research of breast cancer.
6.Comparative study of different image-guided systems in positioning error and placement outside the target area of radiotherapy for cervical cancer
Li LIU ; Chengwei YE ; Jianjun YUAN ; Yingui LUO ; Zhiyao LUO ; Wei ZENG ; Ling LI ; Huan LIU ; Yan LIU ; Miao HE
China Medical Equipment 2025;22(4):18-22
Objective:To compare and analyze the differences in positioning errors and placement outside the target area between two different image-guided systems(Halcyon and Synergy)in radiotherapy for cervical cancer.Methods:The data of 40 patients with cervical cancer who received treatment in Dezhou People's Hospital from March 2023 to June 2023 were retrospectively selected.Each patient was treated respectively with Halcyon linear accelerator and Synergy linear accelerator,with 20 cases for each treatment method.All patients underwent cone beam computed tomography(CBCT)at kV level to conduct image scanning before radiotherapy,and the obtained CBCT images were matched with the positioned CT images by online.The registration results of left and right(x),head and foot(y)and front and back(z)of three translation direction,and pitch(Rx),rotation(Ry)and deflection(Rz)directions of rotation direction were respectively obtained.The margin of planning target volume(MPTV)was calculated according to positioning expansion formula.The differences of positioning errors and target area expansion between Halcyon and Synergy image-guided systems were compared and analyzed.Results:Halcyon and Synergy image-guided systems obtained respectively 479 and 447 sets of CBCT images.The translational errors of Halcyon image-guided system on x,y,and z directions were respectively(-0.03±0.21),(0.12±0.63)and(0.02±0.15)cm,and the rotational errors of that on Rx,Ry and Rz directions were respectively(0.38±1.26)°,(-0.40±1.02)°,and(0.07±1.07)°.The translational errors of Synergy image-guided system were respectively(-0.07±0.18),(0.08±0.49)and(0.11±0.22)cm on the three directions,and the rotational errors of that were respectively(0.28±1.29)°,(-0.29±1.29)° and(-0.16±1.20)°.The translational error values on the y direction of both image-guided system were larger than that on x and z directions,and the absolute values of the range of translational errors of them were basically within 5 mm.There were no statistically significant difference in the positioning errors of rotation on Rx and Ry directions between Halcyon and Synergy image-guided systems(P>0.05),while there was a statistically significant difference in the positioning error of rotation on Rz direction between them(t=-3.06,P<0.05).The MPTV values of Halcyon image-guided system on x,y and z directions were respectively 0.4,1.4 and 0.3 cm,and those of Synergy image-guided system were respectively 0.4,0.9 and 0.5 cm.The expansion boundary of target area of Halcyon image-guided system on the y direction was larger than that of Synergy image-guided system,and that on other directions were all less or equal to 0.5 cm.Conclusion:The MPTV values of Halcyon and Synergy image-guided systems can meet clinical requirements in radiotherapy.The positioning errors and the tube current of the scan of Halcyon image-guided system were larger than those of Synergy image-guided system,but the scanning time and treatment time of that were significantly lower than those of Synergy image-guided system.Different treatment systems can be selected individually for patients according to their different conditions.
7.Effects of preoperative ureteroscopy on the prognosis of patients with upper tract urothelial carcinoma after radical nephroureterectomy
Xingxing LUO ; Jianjun YE ; Qihao WANG ; Lei ZHENG ; Yige BAO
Journal of Modern Urology 2024;29(12):1074-1080
[Objective] To evaluate the effects of preoperative ureteroscopy (URS) on the prognosis of patients with upper tract urothelial carcinoma (UTUC) after radical nephroureterectomy (RNU). [Methods] Data of 712 UTUC patients who received RNU in West China Hospital during May 2003 and Jun.2019 were retrospectively analyzed. Patients were divided into URS group (n=187) and non-URS group (n=525) according to whether URS was performed before RNU. Kaplan-Meier curves were used to analyze the overall survival (OS), cancer-specific survival (CSS), and intravesical recurrence-free survival (IVRFS). Cox proportional risk model was used for risk assessment. Subgroup analysis and interaction test were used to further verify the results. [Results] Significant differences were observed between the two groups in terms of body mass index (BMI), diabetes mellitus, surgical method, hydronephrosis, tumor location, tumor grade, lymph node metastasis, lymphovascular invasion and tumor diameter (P<0.05). Kaplan-Meier survival analysis showed that IVRFS was significantly lower in the URS group than in the non-URS group (P<0.001), and the difference was more pronounced in renal pelvis carcinoma (P<0.001); there were no differences in OS and CSS between the two groups (P>0.05). Cox multivariate regression showed that URS was an independent risk factor for intravesical recurrence (HR=2.12, 95%CI: 1.34-3.36, P<0.001). [Conclusion] Preoperative URS can increase the recurrence rate of UTUC, but it has no effect on the OS and CSS.
8.Research Progress on the Role of HMGB1 in Regulating the Function of Osteoarthritis Chondrocytes
Xin QI ; Xiaogang ZHANG ; Haiyang YU ; Xin CHEN ; Wenbo AN ; Zhipeng WANG ; Duoxian WANG ; Pengfei LUO ; Yixin CHEN ; Jiaojiao MA ; Wei QI ; Ziyang HU ; Jianjun LIU
Medical Journal of Peking Union Medical College Hospital 2024;15(1):141-146
Osteoarthritis (OA) is a chronic degenerative joint disease whose main characteristic is the destruction of articular cartilage, causing pain and disability in patients and seriously affecting their quality of life. OA can be induced by a variety of causes, and pathological changes in articular cartilage are considered to be one of the key driving factors for the occurrence of OA. High mobility group box-1 protein (HMGB1), as a non-histone protein in eukaryotic cells, can participate in regulating the inflammation and apoptosis process of OA chondrocytes, thus leading to the occurrence of OA. This article reviews the research on the mechanism of HMGB1 in OA chondrocytes, with a view to providing new ideas for the clinical prevention and treatment of OA.
9.Interventional precision shunting for portal hypertension
Jingqin MA ; Jianjun LUO ; Zhiping YAN
Journal of Interventional Radiology 2024;33(10):1045-1048
Portal hypertension is a pathological elevation of portal pressure gradient(PPG),often leading to severe complications.Interventional shunting such as transjugular intrahepatic portosystemic shunt(TIPS)has gradually become an important means of treatment,but the postoperative hemodynamic changes are uncertain,therefore,individualized treatment scheme with precision shunting is needed.The purpose of precision shunting is to balance the amount of shunting blood with the amount of blood perfusion in the liver tissue,which can minimize the incidence of complications while relieving symptoms.The determination of hemodynamic goals after interventional shunting is influenced by various factors,and the procedural differences and individual variances should be taken into consideration when making reasonable postoperative hemodynamic targets(optimal PPG).The preliminary results of clinical practice of precision shunting indicates that accurate measurement of preoperative portal pressure and effective monitoring of postoperative hemodynamic status should be emphasized.Future studies should further improve the interventional shunting technique to achieve a more individualized precision treatment.
10.Clinical study of the effect of different CBCT scanning parameters on image quality and positioning error of cervical cancer
Li LIU ; Chengwei YE ; Jianjun YUAN ; Yingui LUO ; Zhiyao LUO ; Wei ZENG ; Ling LI ; Jiang LIU
China Medical Equipment 2024;21(11):18-24
Objective:To assess the effects of the scanning parameters of cone beam computed tomography(CBCT)on image quality,positioning error and additional radiation dose for patients with cervical cancer after tube voltage was reduced,so as to explore scanning conditions that was suitable to patients with cervical cancer.Methods:Seventy-two patients with cervical cancer who received radiotherapy in Deyang People's Hospital from January 2020 to August 2022 were selected.According to different scanning parameters,they were divided into low-dose group A(120 kV,154.4 mAs),low-dose group B(120 kV,228.8 mAs)and conventional group[adopted business-supplied scan sequences(120 kV,675.8 mAs)].The CBCT scan image was obtained by decreasing the tube voltage and tube current,and reducing scanning angle.The registration results of positioning error of low-dose group A,B and conventional group on three directions included left and right(x-axis),head and foot(y-axis)and abdominal and back(z-axis)were respectively obtained,and the results were analyzed by variance analysis.The Catphan503 phantom of X-ray volumetric imaging(XVI)was used to measure the image quality of the corresponding 3 groups,and the further comparison was conducted.Results:There were no significant differences between the three groups in the scanning parameters on x,y and z axis directions for positioning error of patients with cervical cancer(P>0.05).The scanning times of low-dose group A and B were approximately 1 minute,and the scanning time of conventional group was approximately 2 minutes.The noises of low-dose group A and B,and conventional group were respectively 36.51%,26.09%and 18.37%,and the radiation dose that was generated by CBCT image scanning in group A was correspondingly reduced.Conclusion:The reductions of scanning speed and collimator size of CBCT scanning parameters do not affect the positioning error and image quality,and it can decrease the scanning time and additional radiation dose of patients in undergoing radiotherapy.

Result Analysis