1.Environmental contamination status of norovirus outbreaks in schools and nurseries in Linhai City
ZHENG Jianjun, WANG Xi,HONG Danyang, LI Yaling, XU Qiumeng, ZHANG Huili, HAN Qian, LU Da, ZHENG Qiao
Chinese Journal of School Health 2025;46(4):601-603
Objective:
To investigate the environmental contamination of norovirus in nurseries and primary/secondary schools, so as to provide a scientific basis for effective prevention and control measures.
Methods:
A total of 483 external environmental samples were collected from 34 cluster outbreaks of norovirus gastroenteritis in kindergartens and primary/secondary schools in Linhai City from 2021 to 2024. Pathogen detection was conducted using a rapid nucleic acid extraction kit and realtime fluorescence RT-PCR, and the results were analyzed using the χ2 test or Fishers exact test.
Results:
Among the collected external environmental samples, the total positive rate of surface contamination was 13.66%. The positive rates in kindergartens and primary/secondary schools were 12.20% and 15.82%, respectively. In kindergartens, the five surfaces with the highest detection rates were desks/chairs (23.33%), toilet stool troughs (20.69%), urinal troughs (12.00%), washbasins/sinks (11.11%), and toilet mops (9.38%). In primary/secondary schools, the top five were toilet stool troughs (38.30%), urinal troughs (23.53%), toilet door handles (13.04%), toilet mops (12.50%), and drinking cups (11.11%). The difference in positive detection rates among different external environments in primary/secondary schools was statistically significant (Fishers exact probability test, P<0.01). The positive detection rate in sanitary toilets was higher than that in classroom environments (χ2=17.38), while the positive detection rate in classroom environments of kindergartens was higher than that in primary/secondary schools (χ2=5.42)(P<0.05).
Conclusions
Norovirus exhibits a high contamination rate in nurseries and schools, particularly in restroom areas. Strengthening sanitation and disinfection in highrisk environments, and improving hygiene awareness among children and staff, are essential for the effective prevent and control of norovirus.
2.Effect of 3% diquafosol sodium eye drops on the tear film homeostasis of patients wearing orthokeratology lenses
Jiahong HAN ; Jianjun LIU ; Qinbin BAO ; Xu YANG
International Eye Science 2025;25(10):1667-1671
AIM:To investigate the effect of 3% diquafosol sodium eye drops on tear film homeostasis in patients wearing overnight orthokeratology lenses.METHODS:Retrospective study. A total of 340 patients(564 eyes)fitted with night-worn orthokeratology lenses from June to December 2022 were respectively divided into a diquafosol sodium group(200 cases, 323 eyes, treated with 3% diquafosol sodium eye drops)and a sodium hyaluronate group(140 cases, 241 eyes, treated with sodium hyaluronate eye drops). The uncorrected visual acuity(LogMAR), ocular surface disease index(OSDI), non-invasive tear film break-up time(NIBUT), meibomian gland infrared imaging score, and corneal epithelial fluorescein staining were analyzed and compared between the two groups.RESULTS:Compared to baseline, both groups showed significant improvements in uncorrected visual acuity(LogMAR)at 1 wk, 1, and 3 mo after lens wear(all P<0.01). However, no statistically significant difference in uncorrected visual acuity(LogMAR)was observed between the two groups at any time point(all P>0.05). No significant differences in NIBUT or OSDI scores were found between the groups before and at 1 wk after lens wear(all P>0.05). At the 1- and 3 mo follow-ups, the 3% diquafosol sodium group demonstrated significantly longer NIBUT(all P<0.001)and lower OSDI scores(all P<0.001)compared to the sodium hyaluronate group. After wearing lens for 3 mo, the meibomian gland infrared imaging scores were significantly better in the diquafosol sodium group(P<0.001), whereas no significant intergroup difference was observed in corneal fluorescein staining(P>0.05). Furthermore, the incidence of adverse events during the study period did not differ significantly between the two groups(P>0.05).CONCLUSION:Compared with sodium hyaluronate, 3% diquafosol sodium eye drops were more effective in maintaining tear film homeostasis in patients wearing overnight orthokeratology lenses.
3.Diagnosis and treatment of colorectal liver metastases: Chinese expert consensus-based multidisciplinary team (2024 edition).
Wen ZHANG ; Xinyu BI ; Yongkun SUN ; Yuan TANG ; Haizhen LU ; Jun JIANG ; Haitao ZHOU ; Yue HAN ; Min YANG ; Xiao CHEN ; Zhen HUANG ; Weihua LI ; Zhiyu LI ; Yufei LU ; Kun WANG ; Xiaobo YANG ; Jianguo ZHOU ; Wenyu ZHANG ; Muxing LI ; Yefan ZHANG ; Jianjun ZHAO ; Aiping ZHOU ; Jianqiang CAI
Chinese Medical Journal 2025;138(15):1765-1768
4.Significance of precise classification of sacral meningeal cysts by multiple dimensions radiographic reconstruction MRI in guiding operative strategy and rehabilitation.
Jianjun SUN ; Qianquan MA ; Xiaoliang YIN ; Chenlong YANG ; Jia ZHANG ; Suhua CHEN ; Chao WU ; Jingcheng XIE ; Yunfeng HAN ; Guozhong LIN ; Yu SI ; Jun YANG ; Haibo WU ; Qiang ZHAO
Journal of Peking University(Health Sciences) 2025;57(2):303-308
OBJECTIVE:
To precise classify sacral meningeal cysts, effective guide minimally invasive neurosurgery and postoperative personalized rehabilitation by multiple dimensions radiographic reconstruction MRI.
METHODS:
From March to December 2021, based on the original 3D-fast imaging employing steadystate acquisition (FIESTA) scanning sequence, 92 patients with sacral meningeal cysts were pre-operatively evaluated by multiple dimensional reconstruction MRI. The shape of nerve root and the leakage of cyst were reconstructed according to the direction of nerve root or leakage track showed on original MRI scans. Sacral canal cysts were accurately classified as including nerve root and without nerve root, so as to accurately design the incision of skin and formulate corresponding open range of the posterior wall of the sacral canal. Under the microscope intraoperation, the shape of the nerve roots inside cysts or leakage track of the cysts without nerve roots were verified and explored. After the reinforcement and shaping operation, several reexaminations of multiple dimensional reconstruction MRI were performed to understand the deformation of the nerve root and hydrops in the operation cavity, so as to formulate a persona-lized rehabilitation plan for the patients.
RESULTS:
Among the 92 patients with sacral mengingeal cyst, 58 (63.0%) cysts with nerve root cyst, 29 (31.5%) cysts without nerve root cyst, and 5 (5.4%) cysts with mixed sacral canal cyst. In 58 patients with nerve root cysts, the accuracy of preoperative clinical classification on MRI image reached 96.6% (56/58) through confirmation by operating microscope. Only 2 cases of large single cyst with nerve root on the head of cyst were mistaken for without nerve root type. In 29 patients with sacral cyst without nerve root, the accuracy of preoperative image reached 100% through confirmation by operating microscope. The accuracy of judging the internal nerve root and leakage of 12 cases with recurrent sacral cyst was also 100%. Two cases of delayed postoperative hydrops were found one month after operation. After rehabilitation treatment by moxibustion and bathing, the hydrops disappeared 4-6 months after operation.
CONCLUSION
Multiple dimensional reconstruction MRI can precisely make clinical classification of sacral meningeal cysts before operation, guide minimally invasive neurosurgery effectively, and improve the rehabilitation effect.
Humans
;
Magnetic Resonance Imaging/methods*
;
Male
;
Female
;
Sacrum/surgery*
;
Adult
;
Middle Aged
;
Imaging, Three-Dimensional/methods*
;
Cysts/rehabilitation*
;
Aged
;
Adolescent
;
Young Adult
;
Spinal Nerve Roots/diagnostic imaging*
;
Minimally Invasive Surgical Procedures
;
Neurosurgical Procedures/methods*
5.Acquired hemophilia A secondary to cholangiocarcinoma: A case report and literature review.
Xiaoting HAN ; Lei FU ; Liang LI ; Jianjun BIAN ; Mei ZHAO ; Guobin BI
Journal of Central South University(Medical Sciences) 2025;50(2):275-280
Acquired hemophilia A (AHA) is a rare autoimmune bleeding disorder. Its occurrence secondary to hepatobiliary malignancies is even rarer, and without timely diagnosis and treatment, the mortality rate is extremely high. There is a need to raise awareness of this disease. This report describes a case of a 70-year-old female patient diagnosed with AHA 2 months after surgery for cholangiocarcinoma, admitted to the Second Affiliated Hospital of Bengbu Medical College in October 2022. The patient presented with subcutaneous hematoma in both lower limbs. Coagulation function tests showed a markedly prolonged activated partial thromboplastin time (APTT) of 74.5 seconds, with no correction in the APTT mixing test. Coagulation factor assays revealed a severely reduced coagulation factor VIII activity (FVIII:C) of 0.3%, and an inhibitor titer of 25.6 BU/mL was detected. After ruling out other potential causes, the patient was diagnosed with cholangiocarcinoma-associated AHA. With chemotherapy to control the primary tumor, alongside hemostatic and immunosuppressive therapy for inhibitor eradication, AHA was brought under control. The patient had no further coagulation abnormalities or bleeding, enabling timely and full-course chemotherapy for cholangiocarcinoma and significantly improving survival and quality of life. Therefore, in patients with malignancies who present with spontaneous bleeding or unusual bleeding following surgery, trauma, or invasive procedures, clinicians should be alert to the possibility of secondary AHA. Timely diagnosis and treatment can significantly improve prognosis.
Humans
;
Cholangiocarcinoma/surgery*
;
Female
;
Hemophilia A/drug therapy*
;
Aged
;
Bile Duct Neoplasms/surgery*
;
Factor VIII
6.Application of visualized thermosensitive color-changing bolus in postmastectomy radiotherapy for breast cancer
Yong WANG ; Yanze SUN ; Wenmin HAN ; Jianjun QIAN ; Peifeng ZHAO ; Liesong CHEN ; Yaqun ZHU ; Ye TIAN
Chinese Journal of Radiological Medicine and Protection 2025;45(5):431-437
Objective:To explore the feasibility and advantages of applying visualized thermosensitive color-changing bolus in postmastectomy radiotherapy (PMRT) for breast cancer.Methods:Forty patients with breast cancer treated with PMRT in the Second Affiliated Hospital of Soochow University from June 2023 to June 2024 were prospectively selected. They were randomly divided into test and control groups (also referred to as groups A and B, respectively), with 20 patients in each group. Group A, underwent two CT scans: the first scan without bolus (image A1) and the second scan with visualized thermosensitive color-changing bolus (image A2). They were treated with visualized thermosensitive color-changing bolus. Group B also underwent two CT scans: the first scan without bolus (image B1) and the second scan with conventional commercial bolus (image B2), and then were treated with conventional commercial bolus. In the radiotherapy planning, images A1 and A2 were designed as A1-Plan and A2-Plan, and A3-Plan was created by transferring the A1-Plan onto image A2. Images B1 and B2 were designed as B1-Plan and B2-Plan, and B3-Plan was created by transferring the B1-Plan onto image B2. The radiation fields and target optimization functions were identical. The dosimetric differences and skin toxicity reactions between different plans were compared.Results:In Group A, A1-Plan and A2-Plan manifested no statistically significant differences ( P > 0.05) in the doses to organs at risk (OARs), including the ipsilateral lung ( V5 Gy, V10 Gy, V20 Gy), heart ( Dmean), contralateral breast ( Dmean), and skin ( Dmax and Dmean), target homogeneity index (HI), conformity index (CI), prescription dose volume ( V50 Gy), depth of maximum dose ( Dmax), and monitor unit (MU). In Group B, B3-Plan compared to B1-Plan showed reduced V50 Gy (89.9% vs. 95%), HI (0.153 vs. 0.136), and CI (0.817 vs. 0.810), while the two plans displayed no statistically significant differences in doses to OARs. In contrast, A3-Plan and B3-Plan exhibited statistically significant differences ( t = 2.78, 2.29, -0.47, 0.51, 3.13, P < 0.05) in V50 Gy (94.05% vs. 89.90%), Dmax (5 665.4 cGy vs. 5 632.7 cGy), HI (0.148 vs. 0.163), CI (0.83 vs. 0.82), and skin Dmean (5 153.6 cGy vs. 5 048.2 cGy). Compared to the conventional commercial bolus of the same thickness, the visualized thermosensitive color-changing bolus yielded a significantly reduced air cavity volume (3 833 mm 3vs. 21 498 mm 3,t = -9.65, P < 0.05). Both groups experienced only grade I skin toxicity reactions. Conclusions:Compared to the conventional commercial bolus of the same thickness, the visualized thermosensitive color-changing bolus shows a more effective dosimetric distribution in terms of target coverage, HI, and CI, a higher fit to the skin, highly visualized air cavity, and higher positional repeatability in fractionated radiotherapy, demonstrating high practicality and safety.
7.Clinical value of renin-angiotensin-aldosterone system indexes in the diagnosis of essential hypertension
Jianjun SHEN ; He MENG ; Min HAN ; Zengyue WANG
Journal of Chinese Physician 2025;27(6):832-836
Objective:To explore the application value of renin-angiotensin-aldosterone system (RAAS) indexes in the clinical diagnosis of essential hypertension.Methods:Eighty-eight patients with essential hypertension treated in the 962nd Hospital of the PLA Joint Logistics Support Force from April 2023 to May 2024 were enrolled as the observation group, and 80 normotensive healthy subjects undergoing physical examination in the same hospital during the same period were selected as the control group. RAAS-related indexes [angiotensin Ⅱ (ATⅡ), plasma renin activity (PRA), and aldosterone (ALD)] were detected in both groups. The levels of ATⅡ, PRA, ALD, and the ratio of plasma ALD to PRA (ARR) were compared between the two groups and among subgroups with different hypertension severities in the observation group. The diagnostic efficacy of each index for essential hypertension was analyzed by receiver operating characteristic (ROC) curve.Results:The levels of ALD, ATⅡ, and ARR in the observation group were significantly higher than those in the control group, while the PRA level was significantly lower (all P<0.05). Among the three subgroups in the observation group, the levels of ATⅡ, ALD, and ARR showed a significant increasing trend in grade 1, grade 2, and grade 3 hypertension subgroups, while the PRA level showed a significant decreasing trend (all P<0.05). ROC curve analysis showed that the areas under the curve (AUC) of plasma PRA, ATⅡ, ALD, and ARR for the diagnosis of essential hypertension were 0.814, 0.703, 0.687, and 0.879, respectively. The combined detection of the four indexes had an AUC of 0.918, with the highest sensitivity and accuracy. Conclusions:Changes in RAAS indexes are closely related to the occurrence and severity of essential hypertension. PRA and ARR are effective indexes for the diagnosis of essential hypertension. The combined detection of the four indexes can achieve more ideal diagnostic efficacy and improve the diagnostic satisfaction of patients.
8.Effects of Moving Pattern on Dipping Thickness Distributions in Polymer Heart Valve
Haiyang WEI ; Zheng LI ; Qianwen HOU ; Yana MENG ; Liangwei ZHU ; Enhui HAN ; Jianjun HU ; Jianye ZHOU
Journal of Medical Biomechanics 2025;40(4):1012-1019
Objective To explore the impact of different moving patterns during the dip-coating process on thickness distributions of polymer heart valves.Methods Based on the volume of fluid(VOF)multiphase flow model,the Eulerian wall-film(EWF)model,and dynamic mesh technology,the dip-coating manufacturing process of polymer heart valves were numerically simulated.The effects of vertical,horizontal,and circular moving patterns on flow characteristics of the surface impregnation liquid and liquid film distributions under self-rotation conditions of the models were mainly studied.Subsequently,seven identical test points were set on each valve leaflet to collect thickness data,and the coefficient of variation(CV)was calculated to evaluate the uniformity of the liquid film thickness.Given that the vertical and horizontal patterns had fewer moving planes,limiting the optimization space,the circular pattern(45°)with richer moving planes was selected as the basis for optimization,and comparative analysis of numerical simulation was conducted.Results In the vertical pattern,the peak CV was 0.461 3;in the horizontal pattern,the CV was 0.060 8;and in the circular pattern,the CV at 30°,45° and 60° were 0.457 5,0.272 8,and 0.255 6,respectively.After optimization,the CV for the circular pattern(45°)decreased to 0.052 5,representing an 80.7%reduction compared to the pre-optimization value.Conclusions The moving patterns significantly affect the uniformity of dip-coating thickness distributions.The horizontal pattern demonstrates the best uniformity,while the vertical pattern shows the poorest uniformity.The CV for the circular pattern decreases as the angle increases,with its uniformity between that of the vertical and horizontal patterns.Optimization of moving pattern parameters based on simulation results has improved the uniformity of thickness distributions.
9.Effects of Moving Pattern on Dipping Thickness Distributions in Polymer Heart Valve
Haiyang WEI ; Zheng LI ; Qianwen HOU ; Yana MENG ; Liangwei ZHU ; Enhui HAN ; Jianjun HU ; Jianye ZHOU
Journal of Medical Biomechanics 2025;40(4):1012-1019
Objective To explore the impact of different moving patterns during the dip-coating process on thickness distributions of polymer heart valves.Methods Based on the volume of fluid(VOF)multiphase flow model,the Eulerian wall-film(EWF)model,and dynamic mesh technology,the dip-coating manufacturing process of polymer heart valves were numerically simulated.The effects of vertical,horizontal,and circular moving patterns on flow characteristics of the surface impregnation liquid and liquid film distributions under self-rotation conditions of the models were mainly studied.Subsequently,seven identical test points were set on each valve leaflet to collect thickness data,and the coefficient of variation(CV)was calculated to evaluate the uniformity of the liquid film thickness.Given that the vertical and horizontal patterns had fewer moving planes,limiting the optimization space,the circular pattern(45°)with richer moving planes was selected as the basis for optimization,and comparative analysis of numerical simulation was conducted.Results In the vertical pattern,the peak CV was 0.461 3;in the horizontal pattern,the CV was 0.060 8;and in the circular pattern,the CV at 30°,45° and 60° were 0.457 5,0.272 8,and 0.255 6,respectively.After optimization,the CV for the circular pattern(45°)decreased to 0.052 5,representing an 80.7%reduction compared to the pre-optimization value.Conclusions The moving patterns significantly affect the uniformity of dip-coating thickness distributions.The horizontal pattern demonstrates the best uniformity,while the vertical pattern shows the poorest uniformity.The CV for the circular pattern decreases as the angle increases,with its uniformity between that of the vertical and horizontal patterns.Optimization of moving pattern parameters based on simulation results has improved the uniformity of thickness distributions.
10.Clinical value of renin-angiotensin-aldosterone system indexes in the diagnosis of essential hypertension
Jianjun SHEN ; He MENG ; Min HAN ; Zengyue WANG
Journal of Chinese Physician 2025;27(6):832-836
Objective:To explore the application value of renin-angiotensin-aldosterone system (RAAS) indexes in the clinical diagnosis of essential hypertension.Methods:Eighty-eight patients with essential hypertension treated in the 962nd Hospital of the PLA Joint Logistics Support Force from April 2023 to May 2024 were enrolled as the observation group, and 80 normotensive healthy subjects undergoing physical examination in the same hospital during the same period were selected as the control group. RAAS-related indexes [angiotensin Ⅱ (ATⅡ), plasma renin activity (PRA), and aldosterone (ALD)] were detected in both groups. The levels of ATⅡ, PRA, ALD, and the ratio of plasma ALD to PRA (ARR) were compared between the two groups and among subgroups with different hypertension severities in the observation group. The diagnostic efficacy of each index for essential hypertension was analyzed by receiver operating characteristic (ROC) curve.Results:The levels of ALD, ATⅡ, and ARR in the observation group were significantly higher than those in the control group, while the PRA level was significantly lower (all P<0.05). Among the three subgroups in the observation group, the levels of ATⅡ, ALD, and ARR showed a significant increasing trend in grade 1, grade 2, and grade 3 hypertension subgroups, while the PRA level showed a significant decreasing trend (all P<0.05). ROC curve analysis showed that the areas under the curve (AUC) of plasma PRA, ATⅡ, ALD, and ARR for the diagnosis of essential hypertension were 0.814, 0.703, 0.687, and 0.879, respectively. The combined detection of the four indexes had an AUC of 0.918, with the highest sensitivity and accuracy. Conclusions:Changes in RAAS indexes are closely related to the occurrence and severity of essential hypertension. PRA and ARR are effective indexes for the diagnosis of essential hypertension. The combined detection of the four indexes can achieve more ideal diagnostic efficacy and improve the diagnostic satisfaction of patients.


Result Analysis
Print
Save