1.Epidemiological characteristics of tick-borne encephalitis in Heilongjiang province from 2006 to 2020
Zhaodan SUN ; Mingjia BAO ; Xiaoyu WANG ; Jianing SUO ; Xin CHEN ; Shiting ZHANG ; Xue WANG ; Shirui GAO ; Yang JIAO ; Zibo YAN
Chinese Journal of Experimental and Clinical Virology 2025;39(3):361-365
Objective:To analyze the epidemiological characteristics of tick-borne encephalitis (TBE) in Heilongjiang province, to provide a scientific basis for the prevention and control of TBE.Methods:The epidemiological characteristics of TBE were systematically analyzed by the data of TBE cases reported in Disease Surveillance Information Reporting System.Results:A total of 1 127 TBE cases were reported from 2006 to 2020. The average age was 45.8 year, and the case fatality rate was 1.2%. Most TBE cases occurred from April to August, with a peak in June.Conclusions:This research elucidated the epidemiological characteristics of TBE in Heilongjiang province, and provides important basic data for the disease prevention and control.
2.Epidemiological characteristics of tick-borne encephalitis in Heilongjiang province from 2006 to 2020
Zhaodan SUN ; Mingjia BAO ; Xiaoyu WANG ; Jianing SUO ; Xin CHEN ; Shiting ZHANG ; Xue WANG ; Shirui GAO ; Yang JIAO ; Zibo YAN
Chinese Journal of Experimental and Clinical Virology 2025;39(3):361-365
Objective:To analyze the epidemiological characteristics of tick-borne encephalitis (TBE) in Heilongjiang province, to provide a scientific basis for the prevention and control of TBE.Methods:The epidemiological characteristics of TBE were systematically analyzed by the data of TBE cases reported in Disease Surveillance Information Reporting System.Results:A total of 1 127 TBE cases were reported from 2006 to 2020. The average age was 45.8 year, and the case fatality rate was 1.2%. Most TBE cases occurred from April to August, with a peak in June.Conclusions:This research elucidated the epidemiological characteristics of TBE in Heilongjiang province, and provides important basic data for the disease prevention and control.
3.Analysis of Incidence Rate and Related Factors of Thyroid Nodules
Zhenyu YANG ; Jianing SUO ; Yanbo LI
Journal of Medical Research 2017;46(10):47-52
Objective To investigate and analysis the incidence rate and related factors of thyroid nodules in urban and rural health population in Heilongjiang Province.Methods A cross-sectional survey was conducted using stratified cluster random sampling.Carried on the random questionnaire survey,general physical examination and thyroid ultrasonography,collected blood and urine samples;The incidence of thyroid nodules was determined by ultrasound.Results The incidence of thyroid nodules in urban and rural of Heilongjiang Province was 27.77% and 18.18%,(x2 =33.991,P < 0.01).women were higher than men.The incidence of thyroid nodules was significantly increased with the increase of age,(P < 0.01).In addition,urinary iodine,TSH level,TPOAb,TgAb,systolic blood pressure,fasting blood glucose,triglyceride,cholesterol,low density lipoprotein and high density lipoprotein were significantly higher in patients with thyroid nodules than normal population(P < 0.05).Logistic multivariate analysis showed that geographical distribution,gender,age,cholesterol levels and glycosylated hemoglobin were independent risk factors for the incidence of thyroid nodules (P < 0.05),among which the influence of geographical distribution was found for the first time in Heilongjiang region.Conclusion The incidence of thyroid nodules in the urban was significantly higher than that of the rural in Heilongjiang Province,women were higher than men.The incidence of thyroid nodules was significantly higher with age.Geographical distribution gender,age,cholesterol and glycosylated hemoglobin level are independent risk factors for the incidence of thyroid nodules.
4.CT pulmonary angiography using low tube voltage combination with different noise index, low concentration contrast agent: image quality and radiation dose
Yongxia ZHAO ; Ziwei ZUO ; Yanmin WU ; Hongna SUO ; Jianing WANG
Chinese Journal of Radiology 2017;51(6):451-455
Objective To investigate the image quality,radiation dose and iodine intake of CT pulmonary angiography (CTPA) in patients using low tube voltage (100 kVp) combination of different noise indexes (NI) and low concentration contrast agent.Methods A total of 80 patients with suspected pulmonary embolism (PE) and other pulmonary diseases who had undergone CTPA were divided into four groups (A,B,C and D),with 20 patients in each group.Group A underwent 120 kVp CT scan protocol in combination with NI=25 and 370 mg iodine/ml contrast agent,while groups B,C and D underwent 100 kVp CT scan protocol in combination with NI=30,35,40,and 320 mg iodine/ml contrast agent,respectively.All images were restructured using 60% adaptive statistical iterative algorithm 2.0.Objective image quality evaluation included CT values of pulmonary artery,noise values of pulmonary artery,signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR).Subjective image evaluation used a 5-point scoring method and was conducted by two independent radiologists.The CT dose index of volume (CTDIvol),dose-length product (DLP) and iodine intake was recorded,and the mean value was calculated.The DLP was converted to the effective dose (ED).Analysis of Variance or Kruskal-Wallis test was used to evaluate the differences among the four groups in terms of image quality,radiation dose and iodine intake.Results There was a significant difference in CT values of pulmonary artery among the groups A,B,C and D (P<0.05),and the CT values of pulmonary artery of group A was the lowest.There was no significant differences in noises of pulmonary artery,SNR,CNR and subjective indexes scores among the groups A,B,C and D (P>0.05).There was a significant difference in iodine intake among the groups A,B,C and D,iodine intake of the group A was the highest,iodine intake of the group D was the lowest.The iodine intake of groups B,C and D decreased by 12.4% (42/340),13.2% (45/340) and 15.0% (51/340) relative to group A,respectively.There was a significant difference in radiation dose among the groups A,B,C and D,The CTDIvol,DLP and ED of group D decreased by 45.3% (3.9/8.6),48.6% (120/247) and 48.3% (2.02/4.18) relative to group A,respectively (P<0.01).Conclusion Low tube voltage combination with high NI value and low concentration contrast agent can more effectively reduce the radiation dose and iodine intake for CTPA while maintaining diagnostic image quality.
5.Colloidal gold and dot-ELISA rapid tests for screening influenza A virus.
Ning JIA ; Zhong-qiang YAN ; Gang LIU ; Ding-xia SHEN ; Ji-jiang SUO ; Yu-bin XING ; Yan GAO ; Yun-xi LIU
Journal of Southern Medical University 2010;30(10):2267-2269
OBJECTIVETo evaluate the diagnostic efficiency of colloidal gold and dot ELISA rapid tests in clinical screening of influenza A virus.
METHODSThe pharyngeal swabs were collected from 297 outpatients suspected of influenza between June and October, 2009 for detection with colloid gold and dot ELISA rapid test, with real-time PCR as the golden methods. The discrepant results of colloid gold and dot ELISA methods were confirmed by sequencing, and the diagnostic efficiency of the two methods was evaluated.
RESULTSAmong the 166 samples with influenza A virus infection as confirmed by real-time PCR and sequencing, the diagnostic sensitivity of dot ELISA and colloid gold methods was 54.82% (91/166) and 4.22% (7/166), respectively. The total concordance rate with PCR was 66.67% (Kappa value of 0.35). Among the 133 samples negative for influenza A virus, the specificity of dot ELISA and colloid gold methods was 81.68% (107/131) and 98.47% (129/131), respectively, with a total concordance rate with PCR of 45.79% (Kappa value 0.02). Of the 99 H1N1 influenza samples confirmed by real-time PCR, the detection rate of dot ELISA was 67.3%, whereas that of colloid gold was 5.1%. Out of the 107 dot ELISA-positive but colloid gold-negative samples, 84 were confirmed to be influenza A virus-positive by real-time PCR and sequencing. One sample negative for dot ELISA but positive for colloid gold test was confirmed to be influenza A virus-negative. The detection rate and diagnostic concordance rate for influenza A virus by dot ELISA were significantly higher than those of colloid gold (P<0.05).
CONCLUSIONDot ELISA is better than colloid gold in influenza A virus detection and shows great prospect in clinical screening.
Enzyme-Linked Immunosorbent Assay ; Gold Colloid ; Humans ; Influenza A Virus, H1N1 Subtype ; Influenza, Human ; diagnosis ; virology ; Real-Time Polymerase Chain Reaction ; Sensitivity and Specificity

Result Analysis
Print
Save
E-mail