1.A preliminary study on a method for detecting accelerator isocenter deviation using an optical surface monitoring system
Jianqi HU ; Shun ZHOU ; Jiangyan LUO ; Zihong LU ; Junyu LI ; Wen WANG ; Hao WU
Chinese Journal of Radiological Health 2026;35(2):263-271
Objective To detect the isocenter of a medical linear accelerator using an optical surface monitoring system (OSMS) combined with a self-made 3D-printed phantom, and compare with the conventional front pointer measurement method. Methods A phantom that could be fixed to the front pointer of the accelerator was fabricated using 3D printing technology. The front pointer method and OSMS were used to detect the rotation isocenter deviations of the accelerator. During the experiments, the collimator, gantry, and couch linear displacement readings were recorded at different angles. We also recorded the measurement time of different surveyors. Results Compared to the front pointer measurement method, the OSMS method showed lower standard deviations. The reductions in standard deviations showed statistical significance in the Lat direction for the collimator rotation isocenter as well as in the Lat and Vrt directions for the gantry rotation isocenter. The mean deviation of Mag values for the collimator rotation isocenter using the OSMS method was 0.50 mm, which was larger than the 0.42 mm using the front pointer method. However, the standard deviation was 0.06 using the OSMS method, which was smaller than the 0.18 using the front pointer method. The mean deviation and standard deviation of Sag values for the gantry rotation isocenter using the OSMS method were 1.03 mm and 0.12, respectively, which were both larger than 0.47 mm and 0.06 using the front pointer method. For the couch rotation isocenter, the mean deviation and standard deviation using the OSMS method were 0.32 mm and 0.04, respectively, which were both smaller than the 0.55 mm and 0.20 using the front pointer method. All surveyors spent less time in isocenter measurements using the OSMS method compared to the front pointer method. Conclusion Compared with the front pointer method, the OSMS method significantly reduces the standard deviation among surveyors, effectively reduces the influence of the angle deviation of the accelerator on the measurement results, reduces detection time, improves detection efficiency, and provides a powerful practical basis for the application of OSMS in detecting the mechanical accuracy of the linear accelerator.
2.A preliminary study on a method for detecting accelerator isocenter deviation using an optical surface monitoring system
Jianqi HU ; Shun ZHOU ; Jiangyan LUO ; Zihong LU ; Junyu LI ; Wen WANG ; Hao WU
Chinese Journal of Radiological Health 2026;35(2):263-271
Objective To detect the isocenter of a medical linear accelerator using an optical surface monitoring system (OSMS) combined with a self-made 3D-printed phantom, and compare with the conventional front pointer measurement method. Methods A phantom that could be fixed to the front pointer of the accelerator was fabricated using 3D printing technology. The front pointer method and OSMS were used to detect the rotation isocenter deviations of the accelerator. During the experiments, the collimator, gantry, and couch linear displacement readings were recorded at different angles. We also recorded the measurement time of different surveyors. Results Compared to the front pointer measurement method, the OSMS method showed lower standard deviations. The reductions in standard deviations showed statistical significance in the Lat direction for the collimator rotation isocenter as well as in the Lat and Vrt directions for the gantry rotation isocenter. The mean deviation of Mag values for the collimator rotation isocenter using the OSMS method was 0.50 mm, which was larger than the 0.42 mm using the front pointer method. However, the standard deviation was 0.06 using the OSMS method, which was smaller than the 0.18 using the front pointer method. The mean deviation and standard deviation of Sag values for the gantry rotation isocenter using the OSMS method were 1.03 mm and 0.12, respectively, which were both larger than 0.47 mm and 0.06 using the front pointer method. For the couch rotation isocenter, the mean deviation and standard deviation using the OSMS method were 0.32 mm and 0.04, respectively, which were both smaller than the 0.55 mm and 0.20 using the front pointer method. All surveyors spent less time in isocenter measurements using the OSMS method compared to the front pointer method. Conclusion Compared with the front pointer method, the OSMS method significantly reduces the standard deviation among surveyors, effectively reduces the influence of the angle deviation of the accelerator on the measurement results, reduces detection time, improves detection efficiency, and provides a powerful practical basis for the application of OSMS in detecting the mechanical accuracy of the linear accelerator.
3.A preliminary study on a method for detecting accelerator isocenter deviation using an optical surface monitoring system
Jianqi HU ; Shun ZHOU ; Jiangyan LUO ; Zihong LU ; Junyu LI ; Wen WANG ; Hao WU
Chinese Journal of Radiological Health 2026;35(2):263-271
Objective To detect the isocenter of a medical linear accelerator using an optical surface monitoring system (OSMS) combined with a self-made 3D-printed phantom, and compare with the conventional front pointer measurement method. Methods A phantom that could be fixed to the front pointer of the accelerator was fabricated using 3D printing technology. The front pointer method and OSMS were used to detect the rotation isocenter deviations of the accelerator. During the experiments, the collimator, gantry, and couch linear displacement readings were recorded at different angles. We also recorded the measurement time of different surveyors. Results Compared to the front pointer measurement method, the OSMS method showed lower standard deviations. The reductions in standard deviations showed statistical significance in the Lat direction for the collimator rotation isocenter as well as in the Lat and Vrt directions for the gantry rotation isocenter. The mean deviation of Mag values for the collimator rotation isocenter using the OSMS method was 0.50 mm, which was larger than the 0.42 mm using the front pointer method. However, the standard deviation was 0.06 using the OSMS method, which was smaller than the 0.18 using the front pointer method. The mean deviation and standard deviation of Sag values for the gantry rotation isocenter using the OSMS method were 1.03 mm and 0.12, respectively, which were both larger than 0.47 mm and 0.06 using the front pointer method. For the couch rotation isocenter, the mean deviation and standard deviation using the OSMS method were 0.32 mm and 0.04, respectively, which were both smaller than the 0.55 mm and 0.20 using the front pointer method. All surveyors spent less time in isocenter measurements using the OSMS method compared to the front pointer method. Conclusion Compared with the front pointer method, the OSMS method significantly reduces the standard deviation among surveyors, effectively reduces the influence of the angle deviation of the accelerator on the measurement results, reduces detection time, improves detection efficiency, and provides a powerful practical basis for the application of OSMS in detecting the mechanical accuracy of the linear accelerator.
4.A dual-targeting peptide-drug conjugate based on CXCR4 and FOLR1 inhibits triple-negative breast cancer.
Kun WANG ; Cong WANG ; Hange YANG ; Gong CHEN ; Ke WANG ; Peihong JI ; Xudong SUN ; Xuegong FAN ; Jie MA ; Zhencun CUI ; Xingkai WANG ; Hao TIAN ; Dengfu WU ; Lu WANG ; Zhimin WANG ; Jiangyan LIU ; Juan YI ; Kuan HU ; Hailong ZHANG ; Rui WANG
Acta Pharmaceutica Sinica B 2025;15(10):4995-5009
Triple-negative breast cancer is therapeutically challenging due to the low expression of tumor markers and 'cold' tumor immunosuppressive microenvironment. Here, we present a dual-targeting peptide-drug conjugate (PDC) for tumor inhibition. Our PDC efficiently and selectively delivers cytotoxic Monomethyl Auristatin E (MMAE) into tumor cells via C-X-C chemokine receptor type 4 (CXCR4) and folate receptor 1 (FOLR1) for synergistic inhibition of growth and metastasis. Our results show that the dual-targeting PDC has potent antitumor activity in cultured human cells and several murine transplanted tumor models without apparent toxicity. The combination of dual-targeting PDC and radiotherapy modulates the tumor immunosuppressive microenvironment by increasing CD8+ T cell infiltration and attenuating the proportion of myeloid-derived suppressor and regulatory T cells. Therefore, our dual-targeting PDC represents a promising new strategy for cancer therapy that rebalances the immune system and promotes tumor regression.
5.Influence of pre-radiotherapy ultrasonic monitoring of bladder filling levels on setup errors in cervical cancer patients
Jiangyan LUO ; Haizhen YUE ; Jiacheng LIU ; Yichen PU ; Zihong LU ; Jianqi HU ; Hao WU
Chinese Journal of Radiological Medicine and Protection 2025;45(4):290-295
Objective:To investigate the influence of ultrasonic monitoring of bladder filling levels on setup errors before fractionated radiotherapy for cervical cancer patients through a comparative analysis, and its effectiveness in improving clinical target volume (CTV) margins.Methods:A retrospective study was conducted on 1 284 error data of setup via cone beam CT (CBCT) and 6D setup error correction system from 172 cervical cancer patients treated in the Radiotherapy Department of Peking University Cancer Hospital from January 2019 to October 2023. These patients were classified into two groups: 87 (659 times of setup) with ultrasonic monitoring of bladder filling levels and 85 (625 times of setup) without ultrasonic monitoring. The setup errors, error distributions, and numbers of abnormal setups between the two groups were compared in the lateral (Lat), longitudinal (Lng), vertical (Vrt), pitch (Pitch), roll (Roll), and rotational (Rtn) dimensions. Moreover, the CTV to planning target volume(PTV) margin values in the three-dimensional direction were calculated for both groups to assess the clinical value of ultrasonic monitoring of bladder filling levels before fractionated radiotherapy.Results:Compared to the group without ultrasonic monitoring, the group with ultrasonic monitoring exhibited lower median values of setup errors in all six-dimensional directions and smaller upper and lower interquartile ranges ( Z = -10.86 to -6.34, P<0.05). The group with ultrasonic monitoring manifested more concentrated setup errors in various directions and statistically significantly reduced numbers of abnormal setups ( χ2=15.33, P<0.05). Moreover, CTV-PTV margins of the group with ultrasonic monitoring displayed reduced CTV-PTV margin values by 0.55, 1.52, and 1.26 mm in the Vrt, Lng, and Lat directions, respectively. Conclusions:Pre-radiotherapy ultrasonic monitoring of bladder filling levels in cervical cancer patients can significantly improve the repeatability of setup, thus notably reducing the incidence of abnormal setups. Theoretically, it can narrow the range from the CTV to the PTV, thereby minimizing radiation exposure to healthy tissues and ultimately enhancing radiotherapy precision for cervical cancer and reducing radiation damage.
6.Influence of pre-radiotherapy ultrasonic monitoring of bladder filling levels on setup errors in cervical cancer patients
Jiangyan LUO ; Haizhen YUE ; Jiacheng LIU ; Yichen PU ; Zihong LU ; Jianqi HU ; Hao WU
Chinese Journal of Radiological Medicine and Protection 2025;45(4):290-295
Objective:To investigate the influence of ultrasonic monitoring of bladder filling levels on setup errors before fractionated radiotherapy for cervical cancer patients through a comparative analysis, and its effectiveness in improving clinical target volume (CTV) margins.Methods:A retrospective study was conducted on 1 284 error data of setup via cone beam CT (CBCT) and 6D setup error correction system from 172 cervical cancer patients treated in the Radiotherapy Department of Peking University Cancer Hospital from January 2019 to October 2023. These patients were classified into two groups: 87 (659 times of setup) with ultrasonic monitoring of bladder filling levels and 85 (625 times of setup) without ultrasonic monitoring. The setup errors, error distributions, and numbers of abnormal setups between the two groups were compared in the lateral (Lat), longitudinal (Lng), vertical (Vrt), pitch (Pitch), roll (Roll), and rotational (Rtn) dimensions. Moreover, the CTV to planning target volume(PTV) margin values in the three-dimensional direction were calculated for both groups to assess the clinical value of ultrasonic monitoring of bladder filling levels before fractionated radiotherapy.Results:Compared to the group without ultrasonic monitoring, the group with ultrasonic monitoring exhibited lower median values of setup errors in all six-dimensional directions and smaller upper and lower interquartile ranges ( Z = -10.86 to -6.34, P<0.05). The group with ultrasonic monitoring manifested more concentrated setup errors in various directions and statistically significantly reduced numbers of abnormal setups ( χ2=15.33, P<0.05). Moreover, CTV-PTV margins of the group with ultrasonic monitoring displayed reduced CTV-PTV margin values by 0.55, 1.52, and 1.26 mm in the Vrt, Lng, and Lat directions, respectively. Conclusions:Pre-radiotherapy ultrasonic monitoring of bladder filling levels in cervical cancer patients can significantly improve the repeatability of setup, thus notably reducing the incidence of abnormal setups. Theoretically, it can narrow the range from the CTV to the PTV, thereby minimizing radiation exposure to healthy tissues and ultimately enhancing radiotherapy precision for cervical cancer and reducing radiation damage.
7.Comparison of Jinzhen oral liquid and ambroxol hydrochloride and clenbuterol hydrochloride oral solution in the treatment of acute bronchitis in children: A multicenter, non-inferiority, prospective, randomized controlled trial.
Qinhua FAN ; Chongming WU ; Yawei DU ; Boyang WANG ; Yanming XIE ; Zeling ZHANG ; Wenquan SU ; Zizhuo WANG ; Changchang XU ; Xueke LI ; Ying DING ; Xinjiang AN ; Jing CHEN ; Yunying XIAO ; Rong YU ; Nan LI ; Juan WANG ; Yiqun TENG ; Hongfen LV ; Nian YANG ; Yuling WEN ; Xiaoli HUANG ; Wei PAN ; Yufeng LIU ; Xueqin XI ; Qianye ZHAO ; Changshan LIU ; Jian XU ; Haitao ZHANG ; Lie ZHUO ; Qiangquan RONG ; Yu XIA ; Qin SHEN ; Shao LI ; Junhong WANG ; Shengxian WU
Acta Pharmaceutica Sinica B 2024;14(12):5186-5200
The comparison between traditional Chinese medicine Jinzhen oral liquid (JZOL) and Western medicine in treating children with acute bronchitis (AB) showed encouraging outcomes. This trial evaluated the efficacy and safety of the JZOL for improving cough and expectoration in children with AB. 480 children were randomly assigned to take JZOL or ambroxol hydrochloride and clenbuterol hydrochloride oral solution for 7 days. The primary outcome was time-to-cough resolution. The median time-to-cough resolution in both groups was 5.0 days and the antitussive onset median time was only 1 day. This randomized controlled trial showed that JZOL was not inferior to cough suppressant and phlegm resolving western medicine in treating cough and sputum and could comprehensively treat respiratory and systemic discomfort symptoms. Combined with clinical trials, the mechanism of JZOL against AB was uncovered by network target analysis, it was found that the pathways in TRP channels like IL-1β/IL1R/TRPV1/TRPA1, NGF/TrkA/TRPV1/TRPA1, and PGE2/EP/PKA/TRPV1/TRPA1 might play important roles. Animal experiments further confirmed that inflammation and the immune regulatory effect of JZOL in the treatment of AB were of vital importance and TRP channels were the key mechanism of action.
8.Study on the Effects of Atractylodes macrocephala Ethanol Extract on Life Span of Caenorhabditis elegans and Its Mechanism
Jianping ZHAO ; Limin WU ; Xiaona LU ; Hui WANG ; Pan WANG ; Zhenqiang ZHANG ; Jiangyan XU ; Zhishen XIE
China Pharmacy 2021;32(4):418-424
OBJECTIVE: To study the effects of Atractylodes macrocephala ethanol extract (AM) on life span of Caenorhabditis elegans(called N 2 nematode for short ),and to investigate its mechanism based on transcription factor SKN- 1/ nuclear factor E 2 related factor 2(Nrf2). METHODS :N2 nematode were divided into blank control group ,positive control group (100 μ mol/L curcumin,similarly hereinafter ),AM low-dose ,medium-dose and high-dose groups (100,200,300 μ g/mL, similarly hereinafter ). The effects of AM on the life span (by average survival time )of N 2 nematode under normal condition and oxidant stress condition (40 mmol/L H 2O2)as well as its effects on reproductive capability (by the number of filial generation )of N2 nematode under normal condition were investigated . 700 μmol/L H2O2 was used to establish neuroblastoma cells N 2a oxidant stress model. Effects of positive control ,low-dose,medium-dose and high-dose of AM on the survival rate of model cells were detected by MTT method. After human embryonic renalepithelial cells 293T were transfected with Nrf 2-ARE plasmid , the effects of positive control and AM on luciferase activity of Nrf2-ARE were detected by luciferase reporter gene method at low,medium and high dose for 24 h and at medium dose for 12,18 and 24 h. RT-PCR was used to detect the effects ofpositive control ,low-dose,medium-dose and high-dose of AM on the mRNA expression of downstream genes NQO- 1 and HO- 1 of Nrf 2 in N 2a cells as well as mRN A expression of en@hactcm.edu.cn downstream genes GCS- 1,GST-7,GST-10,HSP-60,HSP- 16.2 and SOD- 3 of SKN- 1 in N 2 nematode. RESULTS :Compared with blank control group ,average survival time of N 2 nematode under normal and oxidant stress condition was significantly prolonged in positive control group and AM groups ;the number of filial generation on the first day (except for AM high-dose group ),the number of filial generation on the second day (except for AM low-dose group ) and the total number of filial generation (except for AM low-dose group ) were increased significantly(P<0.05 or P<0.01). The survival rate of N 2a cells in positive control group ,AM medium-dose and high-dose groups were significantly higher than that of model group (P<0.05 or P<0.01). Compared with blank control group ,Nrf2-ARE luciferase relative activity of 293T cells in positive control group and AM groups as well as Nrf 2-ARE luciferase relative activity of 293T cells in AM medium-dose group after different time of treatment were increased significantly (P<0.01),in dose-dependent and time-dependent trend. Compared with blank control group ,mRNA relative expression of HO- 1 and NQO- 1(except for positive control group ),GCS-1(except for AM low-dose group ),GST-7(except for positive control group and AM low-dose group ), GST-10 and HSP- 60(except for AM low-dose group ),HSP-16.2(except for positive control group and AM low-dose group )and SOD-3 (except for positive control group and AM low-dose group ) were increased significantly (P<0.05 or P<0.01). CONCLUSIONS:AM can prolong the life span of N 2 nematode under normal and oxidant stress condition and improve the its reproductive capacity ,the mechanism of which may be associated with the activation of SKN- 1/Nrf2 signaling pathway.
9.Proteomics investigation on periosteum of children with tibia congenital pseudarthrosis
Yaoxi LIU ; Yan CHEN ; Yu ZHENG ; Guanghui ZHU ; Ge YANG ; Shiting XIANG ; Qian TAN ; Jiangyan WU ; Kun LIU ; Shasha MO ; Haibo MEI
Chinese Journal of Orthopaedics 2021;41(2):92-102
Objective:To identify and analyze different proteins expression in the periosteum of congenital pseudarthrosis of the tibia (CPT) using tandem mass tags (TMT) proteomics.Methods:The samples were divided into three groups, namely CPT with neurofibromatosis type 1 (NF1) group (NF1-CPT group), CPT without NF1 group (nonNF1-CPT group) and control group (patients with open tibial fracture). A fold change ≥1.5 or ≤0.66 and P-value <0.05 was regarded as the threshold to screen differentially expressed proteins (DEPs). Subsequently, bioinformatics resources such as online tools DAVID and STRING were used to conduct GO annotation, KEGG pathways enrichment and protein-protein interaction (PPI) network with DEPs. Results:A total of 347 proteins differentially expressed in NF1-CPT group, 212 of which were up-regulated and 135 down-regulated. We identified 467 DEPs in nonNF1-CPT group, including 281 up-regulated and 186 down-regulated. Among of them, NF1-CPT group and nonNF1-CPT group shared 231 DEPs, except for HLA-DRB1 which increased in NF1-CPT group but decreased in nonNF1-CPT group. The remaining 230 DEPs showed the same expression trend in the two positive groups, including 117 up-regulated and 113 down-regulated. In particular, a total of 116 proteins were altered only in NF1-CPT group, including 94 up-regulated and 22 down-regulated. However, there were 236 proteins altered only in nonNF1-CPT group, including 164 up-regulated and 72 down-regulated. The results indicated that the pathogenesis of NF1-CPT was similar as nonNF1-CPT largely with a few differences. Finally, compared with nonNF1-CPT, there were 47 proteins changed 1.5-fold and P-value <0.05 in NF1-CPT group. Conclusion:The proteins expression in the periosteum of CPT is different from that of normal tibia. The expression of periosteal protein is also different between NF1-CPT and nonNF1-CPT. The present study will deepen our understanding of the pathogenesis of CPT in the protein level.
10.Effects of recombinant human syntaxin-4(STX4) on lipopolysaccharide-induced islet β-cell INS-1 injury and underlying mechanism
Jianlin ZHAO ; Yufeng CHEN ; Suyu WU ; Jiangyan LI ; Chengyun XIONG ; Ying ZHANG ; Xiuqin GENG
Chinese Journal of Endocrinology and Metabolism 2021;37(8):738-744
Objective:To explore the effect of recombinant human syntaxin-4(STX4) on lipopolysaccharide(LPS)-induced injury in islet β-cells(INS-1).Methods:Pancreatic islet β-cells(INS-1) were divided into Control (blank control), LPS (LPS treatment), LPS+ NC (transfection of negative control vector, LPS treatment), and LPS+ STX4 (transfection of pcDNA-STX4, LPS treatment) groups. RT-qPCR and Western blot were used to detect STX4 mRNA and protein expression, flow cytometry to detect apoptosis, DCFHDA method to detect reactive oxygen species(ROS) level, xanthine oxidation method to detect superoxide orgotein dismutase(SOD) level, colorimetric method to detect glutathione peroxidase(GSH-Px) level, ammonium molybdate colorimetric method to detect catalase(CAT) level, thiobarbituric acid method to detect malonaldehyde(MDA) level, ELISA method to detect the level of interleukin-1β(IL-1β), tumor necrosis factor-α(TNF-α), and insulin secretion levels under glucose conditions secreted by cells, Western blot method to detect Cleared Caspase-3, Bcl-2 Associated X Protein(Bax), p65 protein expression. After treatment with NF-κB signaling pathway activator, STX4 up-regulated islet β-cell INS-1 was given LPS stimulation, and the same method was used to measure apoptosis, ROS, SOD, GSH-Px, CAT, MDA levels and secreted IL-1β, TNF-α, insulin levels and Cleaved Caspase-3, Bax, p65 protein levels.Results:Compared with the Control group, the expression of STX4 mRNA and protein in islet β cells of the LPS group decreased, the apoptosis rate, ROS level, and MDA levels increased, and the levels of SOD, GSH-Px, and CAT decreased, the levels of IL-1β, TNF-α increased, the level of insulin secreted by the cells decreased, and the expression levels of Cleaved Caspase-3, Bax, and p65 also increased. NF-κB pathway activator treatment reversed the effect of up-regulated STX4 on islet β-cell apoptosis, ROS, SOD, GSH-Px, CAT, MDA levels and secreted IL-1β, TNF-α levels, and Cleaved Caspase-3 , Bax and p65 protein levels.Conclusion:Up-regulation of STX4 alleviated LPS-induced islet β cell oxidative damage, apoptosis and inflammatory factor release. The underlying mechanism might be related to the inhibition of activated NF-κB signaling pathway.