1.Association of NLRP3 genetic variant rs10754555 with early-onset coronary artery disease.
Lingfeng ZHA ; Chengqi XU ; Mengqi WANG ; Shaofang NIE ; Miao YU ; Jiangtao DONG ; Qianwen CHEN ; Tian XIE ; Meilin LIU ; Fen YANG ; Zhengfeng ZHU ; Xin TU ; Qing K WANG ; Zhilei SHAN ; Xiang CHENG
Chinese Medical Journal 2025;138(21):2844-2846
4.The cutting-edge progress of novel biomedicines in ovulatory dysfunction therapy.
Xuzhi LIANG ; Shiyu ZHANG ; Dahai LI ; Hao LIANG ; Yueping YAO ; Xiuhong XIA ; Hang YU ; Mingyang JIANG ; Ying YANG ; Ming GAO ; Lin LIAO ; Jiangtao FAN
Acta Pharmaceutica Sinica B 2025;15(10):5145-5166
Ovulatory dysfunction (OD) is one of the main causes of infertility in women of childbearing age, which not only affects their reproductive ability, but also physical and mental health. Traditional treatment strategies have limited efficacies, and the emergence of biomedicines provides a promising alternative solution via the strategies of combining engineered design with modern advanced technology. This review explores the pathophysiological characteristics and related induction mechanisms of OD, and evaluates the current cutting-edge advances in its treatments. It emphasizes the potentials of biomedicines strategies such as hydrogels, nanoparticles and extracellular vesicles in improving therapeutic precision and efficacy. By mimicking natural physiological processes, and achieving controlled drug release, these advanced drug carriers are expected to address the challenges in ovarian microenvironment reprogramming, tissue repair, and metabolic and immune regulation. Despite the promising progress, there are still challenges in terms of biomedical complexity, differences between animal models and human physiology, and the demand for intelligent drug carriers in the therapy of OD. Future researches are mainly dedicated to developing precise personalized biomedicines in OD therapy through interdisciplinary collaboration, promoting the development of reproductive regenerative medicine.
5.Preliminary application of patient-derived tumor organoids in biliary tract cancers: analysis of 38 cases
Yihang WANG ; Xiaoxiao ZHANG ; Yinghao GUO ; Shuangda MIAO ; Jiawei HU ; Qi LI ; Yanzhi PAN ; Haoran DIAO ; Yun JIN ; Yuanquan YU ; Jiangtao LI
Chinese Journal of Surgery 2025;63(11):1044-1051
Objective:To explore genomic features associated with gemcitabine sensitivity, patient-derived organoid models of biliary tract cancer (BTC) were established and characterized.Methods:This is an experimental study. The tissue specimens of BTC were collected from patients who underwent surgical resection at the Department of Hepatobiliary and Pancreatic Surgery,the Second Affiliated Hospital of Zhejiang University School of Medicine between January 2020 and December 2023. The tumor organoids were cultured in vitro and histologically characterized. Drug sensitivity testing was performed using gemcitabine,cisplatin,paclitaxel,fluorouracil,and lenvatinib etc. to evaluate cell viability. The correlation between the drug sensitivity of organoids and clinical therapeutic response was analyzed.Results:Thirty-eight patient-derived organoids (PDO) models were successfully established from 43 biliary tract malignancy patients with complete follow-up data,including gallbladder cancer PDO 14 cases,distal bile duct cancer PDO 16 cases,intrahepatic cholangiocarcinoma PDO 8 cases,achieving an overall success rate of 88.4%. Drug sensitivity testing (DST) was performed on the successfully generated PDO,with 35 models successfully completing DST experiments. The overall consistency rate between drug responses in PDOs and clinical survival outcomes in corresponding patients was 8/14. Transcriptomic analysis of gemcitabine-sensitive vs. gemcitabine-resistant PDO identified 71 differentially expressed genes in the resistant group,the significantly up-regulated genes including GLDC, LINC01595, IL-27, ANGPTL3, CYP7A1,and AKR1C1;the significantly down-regulated genes including P2RY2,LIPC,and ECHDC3. Conclusion:A biobank of patient-derived organoids of BTC has been established,which demonstrates its potential as preclinical models and tools for predicting chemotherapy responses for BTC patients.
7.Impact of suture configuration and fixation type on biomechanical strength of rotator cuff repair:A factorial design study
Yinzhe CUI ; Zheng YAN ; Jia MA ; Zhefeng JIN ; Jiawen ZHAN ; Minshan FENG ; Guangwei LIU ; Jie YU ; Xu WEI ; Jiangtao SI ; Minghui ZHUANG ; Tao HAN ; Jianguo LI ; ZHANGKAIRUI ; Liguo ZHU
Chinese Journal of Sports Medicine 2025;44(9):729-737
Objective To explore the impact of suture configuration and fixation type on the biome-chanical strength of rotator cuff repair,using a factorial design study.Methods Sixteen fresh-frozen porcine shoulder samples were randomized into an anchorless double-row suture bridge transosseous su-tures(DS)group,an anchored double-row suture bridge transosseous-equivalent(DE)group,an an-chorless X-BOX construct transosseous sutures(XS)group,and an anchored X-BOX construct transos-seous-equivalent(XE)group,each of four,according to suture configuration(double-row suture bridge,traditional X-BOX construct)and fixation type(suture anchors,transosseous sutures).Then,their fatigue resistance(first-cycle excursion,gap length difference ratio,and the percentage of ex-posed footprints)and the failure strength(the maximum failure load and the re-tear type)were mea-sured using a biomechanical material testing machine.Results Different suture configurations affected failure strength(F=39.559,P<0.001),with the double-row suture bridge groups(693.07±58.35 N,746.76±138.57 N)showing significantly higher failure strength,compared to the traditional X-BOX groups(462.90±18.91 N,421.43±90.76 N).However,the fixation type did not significantly im-pact failure strength(F=1.161,P=0.302).Moreover,the suture configuration influenced the gap differ-ence ratio(F=7.781,P=0.016),but had no significant correlation with other fatigue resistance indica-tors(P>0.05).Meanwhile,failure strength and fatigue resistance were not correlated with fixation type,and the interaction between suture and fixation type(P>0.05).The incidence of failure types for the four suture configurations was as follows:Type I tendon tear:XS>XE>DS=DE;type II tendon tear:DS>XE>XS=DE;fixing material-related failure:DE>DS=XE=XS.Conclusion The failure strength and gap formation ratio in rotator cuff repair under fatigue loading are influenced by suture configuration,whereas no significant association has been observed with respect to fixation method,whether using transosseous sutures or suture anchors.
8.Impact of suture configuration and fixation type on biomechanical strength of rotator cuff repair:A factorial design study
Yinzhe CUI ; Zheng YAN ; Jia MA ; Zhefeng JIN ; Jiawen ZHAN ; Minshan FENG ; Guangwei LIU ; Jie YU ; Xu WEI ; Jiangtao SI ; Minghui ZHUANG ; Tao HAN ; Jianguo LI ; ZHANGKAIRUI ; Liguo ZHU
Chinese Journal of Sports Medicine 2025;44(9):729-737
Objective To explore the impact of suture configuration and fixation type on the biome-chanical strength of rotator cuff repair,using a factorial design study.Methods Sixteen fresh-frozen porcine shoulder samples were randomized into an anchorless double-row suture bridge transosseous su-tures(DS)group,an anchored double-row suture bridge transosseous-equivalent(DE)group,an an-chorless X-BOX construct transosseous sutures(XS)group,and an anchored X-BOX construct transos-seous-equivalent(XE)group,each of four,according to suture configuration(double-row suture bridge,traditional X-BOX construct)and fixation type(suture anchors,transosseous sutures).Then,their fatigue resistance(first-cycle excursion,gap length difference ratio,and the percentage of ex-posed footprints)and the failure strength(the maximum failure load and the re-tear type)were mea-sured using a biomechanical material testing machine.Results Different suture configurations affected failure strength(F=39.559,P<0.001),with the double-row suture bridge groups(693.07±58.35 N,746.76±138.57 N)showing significantly higher failure strength,compared to the traditional X-BOX groups(462.90±18.91 N,421.43±90.76 N).However,the fixation type did not significantly im-pact failure strength(F=1.161,P=0.302).Moreover,the suture configuration influenced the gap differ-ence ratio(F=7.781,P=0.016),but had no significant correlation with other fatigue resistance indica-tors(P>0.05).Meanwhile,failure strength and fatigue resistance were not correlated with fixation type,and the interaction between suture and fixation type(P>0.05).The incidence of failure types for the four suture configurations was as follows:Type I tendon tear:XS>XE>DS=DE;type II tendon tear:DS>XE>XS=DE;fixing material-related failure:DE>DS=XE=XS.Conclusion The failure strength and gap formation ratio in rotator cuff repair under fatigue loading are influenced by suture configuration,whereas no significant association has been observed with respect to fixation method,whether using transosseous sutures or suture anchors.
9.Preliminary application of patient-derived tumor organoids in biliary tract cancers: analysis of 38 cases
Yihang WANG ; Xiaoxiao ZHANG ; Yinghao GUO ; Shuangda MIAO ; Jiawei HU ; Qi LI ; Yanzhi PAN ; Haoran DIAO ; Yun JIN ; Yuanquan YU ; Jiangtao LI
Chinese Journal of Surgery 2025;63(11):1044-1051
Objective:To explore genomic features associated with gemcitabine sensitivity, patient-derived organoid models of biliary tract cancer (BTC) were established and characterized.Methods:This is an experimental study. The tissue specimens of BTC were collected from patients who underwent surgical resection at the Department of Hepatobiliary and Pancreatic Surgery,the Second Affiliated Hospital of Zhejiang University School of Medicine between January 2020 and December 2023. The tumor organoids were cultured in vitro and histologically characterized. Drug sensitivity testing was performed using gemcitabine,cisplatin,paclitaxel,fluorouracil,and lenvatinib etc. to evaluate cell viability. The correlation between the drug sensitivity of organoids and clinical therapeutic response was analyzed.Results:Thirty-eight patient-derived organoids (PDO) models were successfully established from 43 biliary tract malignancy patients with complete follow-up data,including gallbladder cancer PDO 14 cases,distal bile duct cancer PDO 16 cases,intrahepatic cholangiocarcinoma PDO 8 cases,achieving an overall success rate of 88.4%. Drug sensitivity testing (DST) was performed on the successfully generated PDO,with 35 models successfully completing DST experiments. The overall consistency rate between drug responses in PDOs and clinical survival outcomes in corresponding patients was 8/14. Transcriptomic analysis of gemcitabine-sensitive vs. gemcitabine-resistant PDO identified 71 differentially expressed genes in the resistant group,the significantly up-regulated genes including GLDC, LINC01595, IL-27, ANGPTL3, CYP7A1,and AKR1C1;the significantly down-regulated genes including P2RY2,LIPC,and ECHDC3. Conclusion:A biobank of patient-derived organoids of BTC has been established,which demonstrates its potential as preclinical models and tools for predicting chemotherapy responses for BTC patients.
10.Study on the prediction of echocardiography combined with diaphragmatic ultrasound on the outcome of removing machine for patients with cardiac valve replacement for mechanical ventilation
Yilan YAO ; Cheng ZHOU ; Shenglin LING ; Jiangtao HAN ; Junlong YU ; Hongqin BI
China Medical Equipment 2024;21(8):70-74,90
Objective:To analyze the predictive value of echocardiography combined with diaphragmatic ultrasound on the outcome of removing machine for patients who underwent cardiac valve replacement for mechanical ventilation.Methods:Retrospectively,a total of 57 patients who adopt mechanical ventilation after underwent cardiac valve replacement in the First People's Hospital of Yibin from January 2022 to March 2023 were selected as the study subjects.According to the results of removing machine,the patients were divided into failed group(11 cases)and successful group(46 cases).All patients underwent echocardiography combined with diaphragmatic ultrasound examination.The indicators of echocardiography,included left ventricular ejection fractions(LVEF),right ventricular fractional area change(RVFAC)and systolic myocardial velocity(Sa),between different groups were compared.The early diastolic mitral annular tissue velocity(e')was recorded to calculate the ratio of early diastolic transmitral flow velocity(E)to e'(E/e'),and the indicators of echocardiography and diaphragmatic ultrasound.Logistic regression analysis was performed to analyze the factors affecting the failure of removing machine.Receiver operating characteristic(ROC)curve was drawn to evaluate the predictive values of echocardiography and diaphragmatic ultrasound indicators for the failure of removing machine in mechanical ventilation.Results:The differences of the differences of LVEF,RVFAC and Sa between failed group and successful group were no significant(P>0.05).The E/e'value of the successful group was 10.06±1.30,which was significantly lower than 12.69±2.96 of the failed group,and the difference was statistically significant(t=2.084,P<0.05).The diaphragm thickening fraction(DTF)and diaphragm excursion(DE)values of the successful group were respectively 41.34±10.74 and 13.04±1.18,which were significantly higher than 19.67±5.37 and 11.27±0.94 of the failed group,respectively,and the differences between the two groups were statistically significant(t=2.148,2.776,P<0.05).The results of logistic regression analysis showed that low expression of DTF and DE,as well as high expression of E/e',were all influence factors for the failure of removing machine for patients adopted mechanical ventilation after underwent cardiac valve replacement.The ROC results showed that the best cut-off value of the prediction model was 0.0893,and the area under curve(AUC)values were 0.713(95%CI:0.646~0.758),0.710(95%CI:0.651~0.779),0.752(95%CI:0.657~0.805)and 0.886(95%CI:0.782~0.991).Conclusion:The combination of echocardiography and diaphragm ultrasound has better prediction for the outcome of removing machine,which high higher clinical application value.

Result Analysis
Print
Save
E-mail