1.Research progress on antimicrobial peptides against methicillin-resistant Staphylococcus aureus
Yuxuan WANG ; Weichang GUO ; Cheng CHEN ; Yao LUO ; Yaxiong XIAO ; Jiangtao LI
China Pharmacy 2025;36(5):636-640
Staphylococcus aureus is a Gram-positive bacterium with strong pathogenicity. With the widespread use of antibiotics, its multi-drug resistance has gradually increased. Among them, methicillin-resistant S. aureus (MRSA) is one of the main pathogens of hospital and community infections. Antimicrobial peptides are short-chain peptides with good antibacterial effects and low drug resistance, which have been widely studied in recent years. This study summarizes the mechanism of action of antimicrobial peptides and related study on antimicrobial peptides against MRSA from different sources. It is found that the mechanisms of action of antimicrobial peptides include targeting bacterial cell membranes, bacterial cells, and bacterial cell walls, etc. Besides isolating antimicrobial peptides with anti-MRSA activity from animals, plants, and microorganisms, antimicrobial peptides can also be obtained through synthetic methods. Among them, GHa-derived peptides from animal sources, Ib-AMP4 from plant sources, Ph-SA from microbial sources, the synthetic peptide LLKLLLKLL-NH2, and so on, due to their effective antibacterial activity, rapid bactericidal speed, and low toxicity, are promising candidates for anti-MRSA drugs.
2.Feasibility of using cortical bone trajectory screws in osteoporotic thoracolumbar fixation based on evaluation of bone CT values at bone-screw interface
Haiming JIN ; Jiangtao LUO ; Jiajie LU ; Jiansen MIAO ; Weiyuan FANG ; Youjin PAN ; Sunren SHENG ; Xiangyang WANG
Chinese Journal of Orthopaedic Trauma 2023;25(1):37-42
Objective:To evaluate the feasibility of using cortical bone trajectory (CBT) screws in the osteoporotic thoracolumbar fixation by comparing the bone CT values at the bone-screw interface between traditional trajectory (TT) screws and CBT screws in patients with different bone densities.Methods:The high-resolution CT imaging data of thoracolumbar segments following thoracic or lumbar spine fractures from April 2020 to October 2022 were collected at The Second Hospital Affiliated to Wenzhou Medical University for retrospective analysis. They were divided into 3 groups: a normal bone mass group, an osteopenia group and an osteoporosis group. From each group 30 cases were chosen (90 cases in total, 36 males and 54 females). All the data were imported into Mimics 18.0 for three-dimensional bone reconstruction in which placement of TT and CBT screws was simulated on the vertebrae from T10 to L2 (non-fractured vertebrae). Regions of interest (ROI) where each simulated screw intersected the bone were segmented to measure their CT bone values. For each vertebra in each group, the relative difference percentage in average CT value of ROI between TT and CBT screws was calculated. The CT values of ROI were compared in the same group between TT and CBT screws from T10 to L2; the CT values of ROI were compared in the same screws among the 3 groups from T10 to L2; the CT values of ROI were compared between the CBT screws in the osteopenia and osteoporosis groups and the TT screws in the normal bone mass group; the relative difference percentages in average CT value of ROI between CBT and TT screws were compared between the 3 groups from T10 to L2.Results:The average CT value of ROI for CBT screws was significantly higher than that for TT screws from T10 to L2 in every group ( P< 0.001); as for the CT values of ROI for CBT and TT screws from T10 to L2, the osteoporosis group
3.Building a New Intelligent Medical Supply Chain Management Platform Based on Internet Information Technology
Rui GUO ; Yan SUN ; Jiangtao WANG ; Xiaolei WU ; Gang WANG ; Zhenyu LUO ; Bin NI ; Dan HAN ; Chunhong YU ; Bihang PAN
Chinese Journal of Modern Applied Pharmacy 2023;40(24):3445-3451
Abstract
OBJECTIVE To construct an intelligent medical supply chain management platform and explore the closed-loop management model of the entire medical supply chain process. METHODS Identify the problems in the traditional drug supply chain management model of medical institutions and propose the idea of building an intelligent medical supply chain management platform. At the same time, systematically introduce the architecture and management of this platform and evaluates its application effect. RESULT After the implementation of the platform, notable enhancements had been observed in the hospital drug supply chain regarding information and intelligence. Moreover, the work efficiency of the hospital drug supply chain had been improved, facilitated the interconnection of drug information between medical institutions, designated medical security information platforms, and pharmaceutical enterprises. Furthermore, the platform had successfully facilitated "resource sharing and technical support" among these three entities, enabling comprehensive traceability of the entire drug supply chain within the region. CONCLUSION Building an intelligent medical supply chain management platform based on internet information technology can help promote digital reform in hospitals, strengthen pharmaceutical management levels, improve medical service quality and has widespread application value within the industry.
4.Progress in surgical treatment of hepatocellular carcinoma with tumor thrombus in the inferior vena cava
Shuyou PENG ; Jiasheng CAO ; Hui LIN ; Linghua CHEN ; Peng LUO ; Jiangtao LI ; Defei HONG ; Xiao LIANG ; Bin ZHANG ; Yu LIU
Chinese Journal of Surgery 2023;61(10):821-825
Hepatocellular carcinoma(HCC) is one of the most common malignancies of the digestive system,which is prone to be associated with microvascular or macrovascular invasion. Among them,HCC with inferior vena cava tumor thrombus(IVCTT) or right atrium tumor thrombus(RATT) is rare and has a poor prognosis. However,surgical treatment of HCC with IVCTT and (or) RATT is rarely reported and summarized. The review described the classification of HCC tumor thrombus with IVCTT and (or) RATT, summarized the progress of surgical approaches and surgical operations,and introduced a case of thrombectomy after pushing from the outer surface of the atrium,rendering the RATT to the inferior vena cava under non-cardiopulmonary bypass. The review also proposed the prospective treatments for HCC with IVCTT or RATT,providing clinical guidance to hepatobiliary surgeons.
5.Progress in surgical treatment of hepatocellular carcinoma with tumor thrombus in the inferior vena cava
Shuyou PENG ; Jiasheng CAO ; Hui LIN ; Linghua CHEN ; Peng LUO ; Jiangtao LI ; Defei HONG ; Xiao LIANG ; Bin ZHANG ; Yu LIU
Chinese Journal of Surgery 2023;61(10):821-825
Hepatocellular carcinoma(HCC) is one of the most common malignancies of the digestive system,which is prone to be associated with microvascular or macrovascular invasion. Among them,HCC with inferior vena cava tumor thrombus(IVCTT) or right atrium tumor thrombus(RATT) is rare and has a poor prognosis. However,surgical treatment of HCC with IVCTT and (or) RATT is rarely reported and summarized. The review described the classification of HCC tumor thrombus with IVCTT and (or) RATT, summarized the progress of surgical approaches and surgical operations,and introduced a case of thrombectomy after pushing from the outer surface of the atrium,rendering the RATT to the inferior vena cava under non-cardiopulmonary bypass. The review also proposed the prospective treatments for HCC with IVCTT or RATT,providing clinical guidance to hepatobiliary surgeons.
6.Pediatric reference intervals for plasma and whole blood procalcitonin of in China: a multicenter research
Zhan MA ; Fangzhen WU ; Jiangtao MA ; Yunsheng CHEN ; Guixia LI ; Jinbo LIU ; Hongbing CHEN ; Huiming YE ; Xingyan BIAN ; Dapeng CHEN ; Jiangwei KE ; Haiou YANG ; Lijuan MA ; Qiuhui PAN ; Hongquan LUO ; Xushan CAI ; Yun XIE ; Wenqi SONG ; Lei ZHANG ; Hong ZHANG
Chinese Journal of Laboratory Medicine 2022;45(6):581-588
Objective:To establish the biology reference interval (RI) of peripheral blood procalcitonin (PCT) for children between 3 days and 6 years old in China.Methods:Totally 3 353 reference individuals with apparent health or no specific diseases were recruited in 18 hospitals throughout the country during October 2020 to May 2021. Reference individuals were divided into four groups: 3-28 days, 29 days - 1 year, 1-3 years and 4-6 years. Vein blood or capillary blood were collected by percutaneous puncture from every reference individual. The PCT level in serum and the capillary whole blood were assayed by Roche Cobas e601 and Norman NRM411-S7 immunoanalyzer. Outliers were deleted and 95th percentiles of every group were provided as RIs. Man-Whitney U test or Kruskal-Wallis test were used performed to assess the difference among different gender, age or method groups. Results:The difference of PCT distribution between male and female is not statistically significant, but the difference between serum and capillary whole blood is statistically significant. The differences between age groups are significant too. For Roche e601, serum PCT RI of 3-28 days group is <0.23 μg/L, 29 days - 6 years are <0.11 μg/L. For NRM411, Serum PCT RI of 3-28 days group is <0.21 μg/L, 29 days - 1 year: <0.09 μg/L, 1 - 6 years: <0.10 μg/L. For whole blood PCT, RI of 3-28 days group is <0.26 μg/L, 29 days - 6 years is <0.15 μg/L.Conclusions:Serum and capillary whole blood PCT have different RIs, however, capillary whole blood PCT testing is valuable in pediatric application. Children in 3-28 days show higher PCT levels than other age group. To establish the RIs and understand the differences among different groups are essential for the interpretation and clinical application of peripheral blood PCT testing results.
7.Status of HVPG clinical application in China in 2021
Wen ZHANG ; Fuquan LIU ; Linpeng ZHANG ; Huiguo DING ; Yuzheng ZHUGE ; Jitao WANG ; Lei LI ; Guangchuan WANG ; Hao WU ; Hui LI ; Guohong CAO ; Xuefeng LU ; Derun KONG ; Lin SUN ; Wei WU ; Junhui SUN ; Jiangtao LIU ; He ZHU ; Dongliang LI ; Wuhua GUO ; Hui XUE ; Yu WANG ; Jiancuo GENGZANG ; Tian ZHAO ; Min YUAN ; Shirong LIU ; Hui HUAN ; Meng NIU ; Xin LI ; Jun MA ; Qingliang ZHU ; Wenbo GUO ; Kunpeng ZHANG ; Xiaoliang ZHU ; Birun HUANG ; Jianan LI ; Weidong WANG ; Hongfeng YI ; Qi ZHANG ; Long GAO ; Guo ZHANG ; Zhongwei ZHAO ; Kai XIONG ; Zexin WANG ; Hong SHAN ; Mingsheng LI ; Xueqiang ZHANG ; Haibin SHI ; Xiaogang HU ; Kangshun ZHU ; Zhanguo ZHANG ; Hong JIANG ; Jianbo ZHAO ; Mingsheng HUANG ; Wenyong SHEN ; Lin ZHANG ; Feng XIE ; Zhiwei LI ; Changlong HOU ; Shengjuan HU ; Jianwei LU ; Xudong CUI ; Ting LU ; Shaoqi YANG ; Wei LIU ; Junping SHI ; Yanming LEI ; Jinlun BAO ; Tao WANG ; Weixin REN ; Xiaoli ZHU ; Yong WANG ; Lei YU ; Qiang YU ; Huiling XIANG ; Wenqiang LUO ; Xiaolong QI
Chinese Journal of Hepatology 2022;30(6):637-643
Objective:The investigation and research on the application status of Hepatic Venous Pressure Gradient (HVPG) is very important to understand the real situation and future development of this technology in China.Methods:This study comprehensively investigated the basic situation of HVPG technology in China, including hospital distribution, hospital level, annual number of cases, catheters used, average cost, indications and existing problems.Results:According to the survey, there were 70 hospitals in China carrying out HVPG technology in 2021, distributed in 28 provinces (autonomous regions and municipalities directly under the central Government). A total of 4 398 cases of HVPG were performed in all the surveyed hospitals in 2021, of which 2 291 cases (52.1%) were tested by HVPG alone. The average cost of HVPG detection was (5 617.2±2 079.4) yuan. 96.3% of the teams completed HVPG detection with balloon method, and most of the teams used thrombectomy balloon catheter (80.3%).Conclusion:Through this investigation, the status of domestic clinical application of HVPG has been clarified, and it has been confirmed that many domestic medical institutions have mastered this technology, but it still needs to continue to promote and popularize HVPG technology in the future.
8.Several suggestions on the classification management process and countermeasures of pulmonary surgery during the COVID-19
Run XIANG ; Qiang LI ; Xiaozun YANG ; Longqi CHEN ; Gang FENG ; Maoyong FU ; Jiangtao PU ; Nanbin YU ; Jiwen LUO ; Jintao HE ; Tianpeng XIE ; Xiaojun YANG ; Liangshuang JIANG ; Zhang CHEN ; Xianyi WANG ; Xiong LIU ; Xiang ZHUANG
Chinese Journal of Thoracic and Cardiovascular Surgery 2020;36(7):415-419
Since the outbreak of corona virus disease 2019(COVID 19), the epidemic has spread rapidly, which brings great challenge to the surgical diagnosis, treatment and management of lung neoplasm Sichuan International Medical Exchange &Promotion Association organized thoracic surgery experts to sum up experiences from experts in major hospital, and formulated the Guidance suggestion on surgical diagnosis, treatment and management of lung neoplasm during the outbreak of COVID-19 to provide references for thoracic surgeons.
9.Analysis on the performance of aldosterone testing and the results of EQA in China
Weiyan ZHOU ; Wenbo LUO ; Qingxiang LIU ; Jiangtao ZHANG ; Rong MA ; Cuihua HU ; Haijian ZHAO ; Chuanbao ZHANG
Chinese Journal of Laboratory Medicine 2020;43(3):267-273
Objective:To evaluate the performance of aldosterone testing in China through the External Quality Assessment (EQA) and improve the testing quality of aldosterone.Methods:Two kinds of EQA program for aldosterone were carried out in China, one of which is Routine EQA and the other is Trueness verification scheme. Lyophilized sera with 5 concentration levels were used as quality control of Routine EQA. The results were grouped according to the instrument. Target values and the coefficient of variation ( CV) were calculated in each group. Trueness verification scheme was verified by using frozen human sera of 3 concentration levels determined by the reference method, and the bias of each instrument group from the target value was calculated. Results:272 laboratories submitted the testing results, and 91.6% of laboratories used chemiluminescence method. The maximum CV was obtained by radioimmunoassay and liquid chromatography mass spectrometry, and the robust CVs were 14.6%-33.4% and 43.5%-53.9%, respectively. For chemiluminescence methods, the robust group CV was less than 10%. The results of the Trueness verification scheme showed that liquid chromatography mass spectrometry method was the most accurate method, with biases of -7.9%, 8.9% and -0.7% for the three quality controls. Diasorin system had the more accurate results deviated from the target by 58.7%, 7.9% and -2.1%, respectively. The results of other chemiluminescence methods were negatively correlated with the sample concentration, and one of them with a bias of 479%. Conclusions:The accuracy and comparability of aldosterone among laboratories in China are not satisfactory. Reagent manufacturers and laboratories should pay more attention to EQA, with the aldosterone results traceable to SI unit, and improve the test quality of aldosterone.
10.Comparison of ID-LC-MS/MS and two CLIAs in measuring plasma aldosterone
Wenbo LUO ; Weiyan ZHOU ; Xilian YI ; Qianqian LI ; Miao LI ; Haijian ZHAO ; Jiangtao ZHANG ; Tianjiao ZHANG ; Jie ZENG ; Ying YAN ; Chuanbao ZHANG
Chinese Journal of Laboratory Medicine 2019;42(7):545-551
Objective Accurate measurement of aldosterone is critical in the diagnosis of primary aldosteronism. We compared the harmonization of three assays including isotope dilution liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS) and two chemiluminescence immunoassays (CLIAs:system A and system B) for the aldosterone measurement. Methods A total of 45 plasma samples, 4 quality control materials, 5 lyophilized bovine serums, and 3 fresh frozen human serum pools were measured by three assays respectively. Based on CLSI EP15-A3 rule, the precision was assessed by coefficient of variance. Deming regression and Bland&Altman plots was performed for method comparison, and correlation coefficient was calculated for concordance (CCC). Results All three methods met the performance criteria based on desirable biological variation for precision (<7.35%). System A showed a relevantly good correlation and comparability with ID-LC/MS/MS (R2=0.985, CCC=0.967), while System B showed relevantly bad correlations and comparability with both System A (R2=0.538, CCC=0.605) and ID-LC/MS/MS (R2=0.547, CCC=0.528).. However, the average relevant bias of two CLIAs exceeded the bias requirement derived from biological variation (18.60%). Conclusion Significant differences were found in the measurement of plasma aldosterone using ID-LC-MS/MS and two CLIAs, which urges the establishment of traceability hierarchy and improvement of reagents' specificity for standardization of aldosterone measurement in clinical settings.


Result Analysis
Print
Save
E-mail